962 resultados para Blood samples


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Blood samples from 159 birds of the New-world family Tyrannidae (the flycatchers) from the eastern plains of Colombia, were examined for haematozoa parasites, in 1999-2000. Haematozoa were detected in six of 20 species. The overall prevalence was 10.1%. The most common parasites detected were microfilariae, followed by Trypanosoma and Plasmodium. The highest prevalence (9.6%) was found in the Ochre-bellied Flycatcher (Mionectes oleaginea). Mixed infections with more than one genus of blood parasite were rare and most infections encountered were of low intensity. The results of this study suggest an important role of ecologically diverse conditions determining composition, transmission, and prevalence of a blood parasite fauna, presumably through host interaction population density. Some new host parasite relationship records are presented.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Since the 1990's, cheating athletes have abused substances to increase their oxygen transport capabilities; among these substances, recombinant EPO is the most well known. Currently, other investigational pharmaceutical products are able to produce an effect similar to EPO but without having chemical structures related to EPO; these are the synthetic erythropoiesis stimulating agents (ESAs). Peginesatide (also known as Hematide?) is being developed by Affymax and Takeda and, if approved by regulatory authorities, could soon be released on the international market. To detect potential athletic abuse of this product and deter athletes who consider cheating, we initiated a collaboration to implement a detection test for anti-doping purposes. Peginesatide is a synthetic, PEGylated, investigational, peptide-based erythropoiesis-stimulating agent that is designed and engineered to stimulate specifically the erythropoietin receptor dimer that governs erythropoiesis. It is undetectable using current anti-doping tests due to its lack of sequence homology to EPO. To detect and deter potential abuse of peginesatide, we initiated an industry/antidoping laboratory collaboration to develop and validate screening and confirmation assays so that they would be available before peginesatide reaches the market. We describe a screening ELISA and a confirmation assay consisting of immune-purification followed by separation with SDS-PAGE and revelation with Western double blotting. Both assays can detect 0.5 ng/mL concentrations of peginesatide in blood samples, enabling detection for several days after administration of a physiologically relevant dose. This initial report describes experimental characterization of these assays, including testing with a blinded set of samples from a clinical study conducted in healthy volunteers.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Transfusion-transmitted malaria is rare, but it may produce severe problem in the safety of blood transfusion due to the lack of reliable procedure to evaluate donors potentially exposed to malaria. Here, we evaluated a new enzyme-linked immunosorbent assay malaria antibody test (ELISA malaria antibody test, DiaMed, Switzerland) to detect antibodies to Plasmodium vivax (the indigenous malaria) in the blood samples in the Republic of Korea (ROK). Blood samples of four groups were obtained and analyzed; 100 samples from P.vivax infected patients, 35 from recovery patients, 366 from normal healthy individuals, and 325 from domestic travelers of non-endemic areas residents to risky areas of ROK. P.vivax antibody levels by ELISA were then compared to the results from microscopic examination and polymerase chain reaction (PCR) test. As a result, the ELISA malaria antibody test had a clinical sensitivity of 53.0% and a clinical specificity of 94.0% for P.vivax. Twenty out of 325 domestic travelers (6.2%) were reactive and 28 cases (8.6%) were doubtful. Of the reactive and doubtful cases, only two were confirmed as acute malaria by both microscopy and PCR test. Thus we found that the ELISA malaria antibody test was insufficiently sensitive for blood screening of P.vivax in ROK.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The aim of our study was to provide an innovative headspace-gas chromatography-mass spectrometry (HS-GC-MS) method applicable for the routine determination of blood CO concentration in forensic toxicology laboratories. The main drawback of the GC/MS methods discussed in literature for CO measurement is the absence of a specific CO internal standard necessary for performing quantification. Even if stable isotope of CO is commercially available in the gaseous state, it is essential to develop a safer method to limit the manipulation of gaseous CO and to precisely control the injected amount of CO for spiking and calibration. To avoid the manipulation of a stable isotope-labeled gas, we have chosen to generate in a vial in situ, an internal labeled standard gas ((13)CO) formed by the reaction of labeled formic acid formic acid (H(13)COOH) with sulfuric acid. As sulfuric acid can also be employed to liberate the CO reagent from whole blood, the procedure allows for the liberation of CO simultaneously with the generation of (13)CO. This method allows for precise measurement of blood CO concentrations from a small amount of blood (10 μL). Finally, this method was applied to measure the CO concentration of intoxicated human blood samples from autopsies.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Given the scarcity of epidemiological information on hepatitis C virus (HCV) infection in Northern Brazil, we determined the prevalence and genotypic frequency in blood donors in the state of Pará (PA). Blood samples from all of the blood donors at the Fundação HEMOPA (blood bank of PA) from 2004-2006 were screened for the presence of antibodies to anti-HCV and samples seroreactive to anti-HCV were further tested for HCV RNA using real-time PCR. In total, 116 HCV-RNA samples were genotyped, based on maximum likelihood phylogenetic analyses, using BioEdit, Modelgenerator, PHYML and FigTree software. The population consisted of 242,726 volunteers who donated blood from 2004-2006; the most common subgroup was males between the ages of 18-29 years old (37.30%). Within the whole group, 1,112 blood donors (0.46%) had indeterminate or positive serology; among these, 28.78% were males whose ages ranged from 18-29 years. A diagnosis of chronic HCV infection was confirmed for 304 donors (60.20% males; 66.45% were 30-49 years old), resulting in a prevalence of HCV RNA in 0.13% of the samples (304 of 242,726). HCV genotyping revealed a high frequency of genotype 1 (108/116) followed by genotype 3 (8/116). This study found HCV infection to be relatively infrequent in PA; genotype 1 was most commonly isolated. This information can help guide prevention and control policies aimed at efficient diagnosis and control measures.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The diagnosis of visceral leishmaniasis (VL) generally requires the use of invasive tests for the collection of infected tissue (aspirates of bone marrow, spleen, liver or lymph nodes). This difficulty has led to the search for safer and less painful techniques to confirm the occurrence of the disease in children. Polymerase chain reaction (PCR) is a method that is advantageous in that it allows the use of peripheral blood samples for diagnosis. This paper reports the utilisation of PCR on peripheral blood samples to diagnose VL in 45 children in Mato Grosso do Sul, Brazil. This technique is compared with methods carried out using tissue collected by invasive procedures, including direct microscopy, culture and detection of Leishmania DNA by PCR in bone marrow aspirates. The results show that PCR of peripheral blood provides great sensitivity (95.6%) that is similar to that from the PCR of bone marrow aspirates (91.1%) and higher than that achieved with microscopy (80%) or culture (26.7%) methods. PCR of peripheral blood proved to be a suitable tool for the diagnosis of VL in children because it is highly sensitive and safe, with tissue collection being less invasive than in traditional tests.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVE: Off-pump coronary artery bypass grafting has stimulated the development of micro-pumps designed to prevent the hemodynamic instability induced by heart luxation for the exposure of target vessels of the posterior wall. Impella (Aachen, Germany) developed micro-pumps with a miniaturized propeller system for both sides of the heart. The aim of this study was to analyze the impact of both pumps working together on blood cell integrity. MATERIALS AND METHODS: Both right and left-sided micro-pumps were implanted in 5 calves (body weight, 72_4 Kg) during 3 h. Blood samples for hematology and hemolysis parameters were drawn hourly. RESULTS: Both pumps performed well with a flow of 3.6 L +/- 0.3 L during the 3 h of the experiment with stable hemodynamic conditions. Mixed venous oxygen saturation was 63.4 +/- 15.2% at baseline and 63.8 +/- 16.3% at the end of the experiment (P = ns). Red cell count, LDH and free plasma hemoglobin were 6.7 +/- 2.1 x 10(12)/L, 1807 +/- 437 IU/L, and 32 +/- 9 mg/L at baseline vs. 6.1 +/- 2.1 x 10(12)/L, 1871 +/- 410 IU/L, and 52 +/- 9 mg/L at the end of the experiment (P = ns for all comparisons). Platelet count exhibited a non-significant drop (872 +/- 126 vs. 715 +/- 22 x 10(9)/L). CONCLUSIONS: This double pump system based on the Archimed screw principle is hematologically well tolerated under conditions of prolonged cardiac assist.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Preoperative chemoradiation significantly improves oncological outcome in locally advanced rectal cancer. However there is no effective method of predicting tumor response to chemoradiation in these patients. Peripheral blood mononuclear cells have emerged recently as pathology markers of cancer and other diseases, making possible their use as therapy predictors. Furthermore, the importance of the immune response in radiosensivity of solid organs led us to hypothesized that microarray gene expression profiling of peripheral blood mononuclear cells could identify patients with response to chemoradiation in rectal cancer. Thirty five 35 patients with locally advanced rectal cancer were recruited initially to perform the study. Peripheral blood samples were obtained before neaodjuvant treatment. RNA was extracted and purified to obtain cDNA and cRNA for hybridization of microarrays included in Human WG CodeLink bioarrays. Quantitative real time PCR was used to validate microarray experiment data. Results were correlated with pathological response, according to Mandard´s criteria and final UICC Stage (patients with tumor regression grade 1-2 and downstaging being defined as responders and patients with grade 3-5 and no downstaging as non-responders). Twenty seven out of 35 patients were finally included in the study. We performed a multiple t-test using Significance Analysis of Microarrays, to find those genes differing significantly in expression, between responders (n = 11) and non-responders (n = 16) to CRT. The differently expressed genes were: BC 035656.1, CIR, PRDM2, CAPG, FALZ, HLA-DPB2, NUPL2, and ZFP36. The measurement of FALZ (p = 0.029) gene expression level determined by qRT-PCR, showed statistically significant differences between the two groups. Gene expression profiling reveals novel genes in peripheral blood samples of mononuclear cells that could predict responders and non-responders to chemoradiation in patients with locally advanced rectal cancer. Moreover, our investigation added further evidence to the importance of mononuclear cells' mediated response in the neoadjuvant treatment of rectal cancer.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Résumé : Un nombre croissant de cas de malaria chez les voyageurs et migrants a été rapporté. Bien que l'analyse microscopique des frottis sanguins reste traditionnellement l'outil diagnostic de référence, sa fiabilité dépend considérablement de l'expertise de l'examinateur, pouvant elle-même faire défaut sous nos latitudes. Une PCR multiplex en temps réel a donc été développée en vue d'une standardisation du diagnostic. Un ensemble d'amorces génériques ciblant une région hautement conservée du gène d'ARN ribosomial 18S du genre Plasmodium a tout d'abord été conçu, dont le polymorphisme du produit d'amplification semblait suffisant pour créer quatre sondes spécifiques à l'espèce P. falciparum, P. malariae, P. vivax et P. ovale. Ces sondes utilisées en PCR en temps réel se sont révélées capables de détecter une seule copie de plasmide de P. falciparum, P. malariae, P. vivax et P. ovale spécifiquement. La même sensibilité a été obtenue avec une sonde de screening pouvant détecter les quatre espèces. Quatre-vingt-dix-sept échantillons de sang ont ensuite été testés, dont on a comparé la microscopie et la PCR en temps réel pour 66 (60 patients) d'entre eux. Ces deux méthodes ont montré une concordance globale de 86% pour la détection de plasmodia. Les résultats discordants ont été réévalués grâce à des données cliniques, une deuxième expertise microscopique et moléculaire (laboratoire de Genève et de l'Institut Suisse Tropical de Bâle), ainsi qu'à l'aide du séquençage. Cette nouvelle analyse s'est prononcé en faveur de la méthode moléculaire pour tous les neuf résultats discordants. Sur les 31 résultats positifs par les deux méthodes, la même réévaluation a pu donner raison 8 fois sur 9 à la PCR en temps réel sur le plan de l'identification de l'espèce plasmodiale. Les 31 autres échantillons ont été analysés pour le suivi de sept patients sous traitement antimalarique. Il a été observé une baisse rapide du nombre de parasites mesurée par la PCR en temps réel chez six des sept patients, baisse correspondant à la parasitémie déterminée microscopiquement. Ceci suggère ainsi le rôle potentiel de la PCR en temps réel dans le suivi thérapeutique des patients traités par antipaludéens. Abstract : There have been reports of increasing numbers of cases of malaria among migrants and travelers. Although microscopic examination of blood smears remains the "gold standard" in diagnosis, this method suffers from insufficient sensitivity and requires considerable expertise. To improve diagnosis, a multiplex real-time PCR was developed. One set of generic primers targeting a highly conserved region of the 18S rRNA gene of the genus Plasmodium was designed; the primer set was polymorphic enough internally to design four species-specific probes for P. falciparum, P. vivax, P. malarie, and P. ovale. Real-time PCR with species-specific probes detected one plasmid copy of P. falciparum, P. vivax, P. malariae, and P. ovale specifically. The same sensitivity was achieved for all species with real-time PCR with the 18S screening probe. Ninety-seven blood samples were investigated. For 66 of them (60 patients), microscopy and real-time PCR results were compared and had a crude agreement of 86% for the detection of plasmodia. Discordant results were reevaluated with clinical, molecular, and sequencing data to resolve them. All nine discordances between 18S screening PCR and microscopy were resolved in favor of the molecular method, as were eight of nine discordances at the species level for the species-specific PCR among the 31 samples positive by both methods. The other 31 blood samples were tested to monitor the antimalaria treatment in seven patients. The number of parasites measured by real-time PCR fell rapidly for six out of seven patients in parallel to parasitemia determined microscopically. This suggests a role of quantitative PCR for the monitoring of patients receiving antimalaria therapy.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Introduction: Blood doping (BD) is the use of Erythropoietic Stimulating Agents (ESAs) and/or transfusion to increase aerobic performance in athletes. Direct toxicologic techniques are insufficient to unmask sophisticated doping protocols. The Hematological module of the ABP (World Anti-Doping Agency), associates decision support technology and expert assessment to indirectly detect BD hematological effects. Methods: The ABP module is based on blood parameters, under strict pre-analytical and analytical rules for collection, storage and transport at 2-12°C, internal and external QC. Accuracy, reproducibility and interlaboratory harmonization fulfill forensic standard. Blood samples are collected in competition and out-ofcompetition. Primary parameters for longitudinal monitoring are: - hemoglobin (HGB); - reticulocyte percentage (RET); - OFF score, indicator of suppressed erythropoiesis, calculated as [HGB(g/L) * 60-√RET%]. Statistical calculation predicts individual expected limits by probabilistic inference. Secondary parameters are RBC, HCT, MCHC-MCH-MCV-RDW-IFR. ABP profiles flagged as atypical are review by experts in hematology, pharmacology, sports medicine or physiology, and classified as: - normal - suspect (to target) - likely due to BD - likely due to pathology. Results: Thousands of athletes worldwide are currently monitored. Since 2010, at least 35 athletes have been sanctioned and others are prosecuted on the sole basis of abnormal ABP, with a 240% increase of positivity to direct tests for ESA, thanks to improved targeting of suspicious athletes (WADA data). Specific doping scenarios have been identified by the Experts (Table and Figure). Figure. Typical HGB and RET profiles in two highly suspicious athletes. A. Sample 2: simultaneous increases in HGB and RET (likely ESA stimulation) in a male. B. Samples 3, 6 and 7: "OFF" picture, with high HGB and low RET in a female. Sample 10: normal HGB and increased RET (ESA or blood withdrawal). Conclusions: ABP is a powerful tool for indirect doping detection, based on the recognition of specific, unphysiological changes triggered by blood doping. The effect of factors of heterogeneity, such as sex and altitude, must also be considered. Schumacher YO, et al. Drug Test Anal 2012, 4:846-853. Sottas PE, et al. Clin Chem 2011, 57:969-976.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Although gravity drainage has been the standard technique for cardiopulmonary bypass (CPB), the development of min imally invasive techniques for cardiac surgery has renewed interest in using vacuum assisted venous drainage (VAVD) Dideco (Mirandola, Italy) has modified the D903 Avant oxygenator to apply a vacuum to its venous reservoir. The impact of VAVD on blood damage with this device is analyzed. Six calves (mean body weight, 71.3 +/- 4.1 kg) were con nected to CPB by jugular venous and carotid arterial cannu lation, with a flow rate of 4-4.51 L/min for 6 h. They were assigned to gravity drainage (standard D903 Avant oxygen ator, n = 3) or VAVD (modified D903 Avant oxygenator, n = 3). The animals were allowed to survive for 7 days. A standard battery of blood samples was taken before bypass, throughout bypass, and 24 h, 48 h, and 7 days after bypass. Analysis of variance was used for repeated measurements. Thrombocyte and white blood cell counts, corrected by hematocrit and normalized by prebypass values, were not significantly different between groups throughout all study periods. The same holds true for hemolytic parameters (lactate dehydrogenase [LDH] and plasma hemoglobin). Both peaked at 24 hr in the standard and VAVD groups: LDH, 2,845 +/- 974 IU/L vs. 2,537 +/- 476 IU/L (p = 0.65), respectively; and plasma hemoglobin, 115 +/- 31 mg/L vs. 89 +/- 455 mg/L (p = 0.45), respectively. In this experimental setup with prolonged perfusion time, VAVD does not increase trauma to blood cells in comparison with standard gravity drainage.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background: Colorectal cancer (CRC) can be cured when diagnosed in its early or precancerous (adenoma) stages. Mostly due to poor compliance towards invasive screening procedures, detection rates for adenoma and early CRCs are still low. Available non-invasive screening tests have unfortunately low sensitivity and specificity performances. Therefore, there is a large unmet need calling for a cost-effective, reliable and non-invasive test to screen for early neoplastic and pre-neoplastic lesions. Objective: To develop a routine screening test based on a nucleic acids multi-gene assay performed on peripheral blood mononuclear cells (PBMCs) that can detect early CRCs and adenomas. Methods: 116 patients (mean age: 55 years; range: 18 to 74 years; female/male ration 0.98) were included in this pilot, nonblinded, colonoscopy-controlled study. Colonoscopy revealed 21 patients with CRC, 30 patients with adenoma bigger than 1 cm, 24 patients with inflammatory bowel disease (IBD) and 41 patients had no neoplastic or inflammatory lesions. Blood samples were taken from each patient the day of the colonoscopy and PBMCs were purified. Total RNA was extracted following standard procedures. Multiplex RT-qPCR was applied on 92 different candidate biomarkers. Different univariate and multivariate statistical methods were applied on these candidates, and among them, 57 biomarkers with significant p values (<0.01, Wilcoxon test) were selected, including ADAMTS1, MMP9, CXCL10, CXCR4, VEGFA and CDH1. Two distinct biomarker signatures are used to separate patients without neoplastic lesion from those with cancer (named COLOX 1 test), respectively from those with adenoma (named COLOX 2 test). Result: COLOX 1 and 2 tests have successfully separated patients without neoplastic lesion from those with CRC (sensitivity 70%, specificity 90%, AUC 0.88), respectively from those with adenoma bigger than 1cm (sensitivity 61%, specificity 80%, AUC 0.80). 6/24 patients in the IBD group have a positive COLOX 1 test. Conclusion: These two COLOX tests demonstrated an acceptable sensitivity and a high specificity to detect the presence of CRCs and adenomas bigger than 1 cm. The false positives COLOX 1 test in IBD patients could possibly be due to the chronic inflammatory state. A prospective, multicenter, pivotal study is underway in order to confirm these promising results in a larger cohort.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Résumé Fondement : le développement de solutions d'hydroxy-éthyl-amidons (HEAS) avec peu d'impact sur la coagulation sanguine, mais un effet supérieur sur la volémie, par comparaison aux HEAS couramment utilisés, est d'un grand intérêt clinique. Nous posons l'hypothèse que des solutions de haut poids moléculaire et de bas degré de substitution possèdent ces caractéristiques. Méthode : trente porcs ont été perfusés avec trois HEAS différents (20 ml/kg) de même degré de substitution (0.42) mais de poids moléculaire différent (130, 500 et 900 kDa). Une série de prélèvements sanguins ont été effectués sur 24 heures, sur lesquels des analyses de coagulation sanguine étaient effectuées par thromboélastographie et dosages plasmatiques. De plus, la concentration plasmatique ainsi que le poids moléculaire in vivo ont été déterminés, ainsi que des paramètres de pharmacocinétiques, ceci en se basant sur un modèle bi-compartimental. Résultats : les analyses de thromboélastographie et les tests de coagulation plasmatique n'ont pas démontré d'altération plus marquée de la coagulation sanguine après l'utilisation des solutions des HAES 500 et HAES 900, par comparaison avec celle de HAES 130. Par contre, les HAES 500 et HAES 900 ont présenté une plus grande aire sous la courbe (area under the curve), dans la relation concentration en fonction du temps [1542 (142) g min litre-1, p<0.001, 1701 (321) g min litre-1, p<0.001] par rapport au HAES 130 [1156 (223) g min litre-1]. La demi-vie alpha (t ½α) était plus longue pour les HAES 500 [53.8 (8.6) min, p<0.01] et HAES 900 [57.1 (12.3) min, p<0.01 ]que pour le HAES 130 [39.9 (10.7) min]. La demi-vie beta (t½β) était par contre similaire pour les trois types de HAES [de 332 (100) à 381 (63) min]. Conclusions : pour les HAES de bas degré de substitution, le poids moléculaire n'est pas un facteur clé en ce qui concerne l'altération de la coagulation. La persistance intravasculaire initialement plus longue des HAES de haut poids moléculaire et bas degré de substitution pourrait résulter dans un plus long effet volémique de ces substances. Abstract Background: The development of hydroxyethyl starches (HES) with low impact on blood coagulation but higher volume effect compared with the currently used HES solutions is of clinical interest. We hypothesized that high molecular weight, low-substituted HES might possess these properties. Methods: Thirty pigs were infused with three different HES solutions (20 ml kg-1) with the same degree of molar substitution (0.42) but different molecular weights (130, 500 and 900 kDa). Serial blood samples were taken over 24 h and blood coagulation was assessed by Thromboelastograph® analysis and analysis of plasma coagulation. In addition, plasma concentration and in vivo molecular weight were determined and pharmacokinetic data were computed based on a two-compartment model. Results: Thromboelastograph analysis and plasma coagulation tests did not reveal a more pronounced alteration of blood coagulation with HES 500 and HES 900 compared with HES 130. In contrast, HES 500 and HES 900 had a greater area under the plasma concentration-time curve [1542 (142) g min litre-1, P<0.001, 1701 (321) g min litre-1, P<0.001] than HES 130 [I 156 (223) g min litre-1] and alpha half life (t ½α) was longer for HES 500 [53.8 (8.6) min, P<0.01 ] and HES 900 [57. I (I 2.3) min, P<0.01 ] than for HES 130 [39.9 (I 0.7) min]. Beta half life (t½β), however, was similar for all three types of HES [from 332 (100) to 381 (63) min]. Conclusions. In low-substituted HES, molecular weight is not a key factor in compromising blood coagulation. The longer initial intravascular persistence of high molecular weight lowsubstituted HES might result in a longer lasting volume effect.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The in vivo effects of Diaspirin Crosslinked Hemoglobin (DCLHb, Baxter Healthcare Corp.) on hematology and biochemistry are unknown. This study includes 6 calves (71.2+/-1.3 kg). In each animal a total of 2 litres of blood was exchanged for the same amount of hydroxylethyl starch (Haes, Fresenius) (n=3) or DCLHb (n=3), which is equivalent to 28cc/kg of blood substitute, over a period of 5 hours. The animals were allowed to survive 7 days. Blood samples were taken hourly during the perfusion protocol, at postoperative day (POD) 1, 2 and 7. ANOVA test was used for repeated measurements. Blood cell profiles were similar in both groups. Peak methemoglobinemia was 4.2% in the DCLHb group. Osmolarity was significantly higher in the DCLHb group with the greatest difference at POD 1 and 2. Postmortem analysis of the major organs did not show any sign of hemoglobin deposit in the DCLHb group. In the given setup DCLHb can be administered in a large quantity with good hematological tolerance and without any deposits in major organs. A prolonged plasma expander effect was observed.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND: The objective is to develop a cost-effective, reliable and non invasive screening test able to detect early CRCs and adenomas. This is done on a nucleic acids multigene assay performed on peripheral blood mononuclear cells (PBMCs). METHODS: A colonoscopy-controlled study was conducted on 179 subjects. 92 subjects (21 CRC, 30 adenoma >1 cm and 41 controls) were used as training set to generate a signature. Other 48 subjects kept blinded (controls, CRC and polyps) were used as a test set. To determine organ and disease specificity 38 subjects were used: 24 with inflammatory bowel disease (IBD),14 with other cancers (OC). Blood samples were taken and PBMCs were purified. After the RNA extraction, multiplex RT-qPCR was applied on 92 different candidate biomarkers. After different univariate and multivariate analysis 60 biomarkers with significant p-values (<0.01) were selected. 2 distinct biomarker signatures are used to separate patients without lesion from those with CRC or with adenoma, named COLOX CRC and COLOX POL. COLOX performances were validated using random resampling method, bootstrap. RESULTS: COLOX CRC and POL tests successfully separate patients without lesions from those with CRC (Se 67%, Sp 93%, AUC 0.87), and from those with adenoma > 1cm (Se 63%, Sp 83%, AUC 0.77). 6/24 patients in the IBD group and 1/14 patients in the OC group have a positive COLOX CRC. CONCLUSION: The two COLOX tests demonstrated a high Se and Sp to detect the presence of CRCs and adenomas > 1 cm. A prospective, multicenter, pivotal study is underway in order to confirm these promising results in a larger cohort.