993 resultados para Background measurements


Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Acute mesenteric ischemia (AMI) is an emergency with a mortality rate up to 50 %. Detecting AMI continues to be a major challenge. This study assed the correlation of repeated preoperative serum lactate with bowel necrosis and to identify risk factors for a lethal outcome in patients with AMI. METHODS A retrospective study of 91 patients with clinically and pathologically confirmed AMI from January 2006 to December 2012 was performed. RESULTS In-hospital mortality rate was 42.9 %. Two hundred nine preoperative lactate measurements were analyzed (2.3 ± 1.1 values per patient). Less than or equal to six hours prior to surgery, the mean serum lactate level was significantly higher (4.97 ± 4.21 vs. 3.24 ± 3.05 mmol/L, p = 0.006) and the mean pH significantly lower (7.28 ± 0.12 vs. 7.37 ± 0.08, p = 0.001) compared to >6 h before surgery. Thirty-four patients had at least two lactate measurements within 24 h prior to surgery. In this subgroup, 17 patients (50 %) exhibited an increase, 17 patients (50 %) a decrease in lactate levels. Forward logistic regression analysis showed that length of necrotic bowel and the highest lactate value 24 h prior to surgery were independent risk factors for mortality (r (2)  = 0.329). CONCLUSION The value of serial lactate and pH measurements to predict the length of necrotic bowel is very limited. Length of necrotic bowel and lactate values are independent risk factors for mortality.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND The aim of this study was to evaluate the accuracy of linear measurements on three imaging modalities: lateral cephalograms from a cephalometric machine with a 3 m source-to-mid-sagittal-plane distance (SMD), from a machine with 1.5 m SMD and 3D models from cone-beam computed tomography (CBCT) data. METHODS Twenty-one dry human skulls were used. Lateral cephalograms were taken, using two cephalometric devices: one with a 3 m SMD and one with a 1.5 m SMD. CBCT scans were taken by 3D Accuitomo® 170, and 3D surface models were created in Maxilim® software. Thirteen linear measurements were completed twice by two observers with a 4 week interval. Direct physical measurements by a digital calliper were defined as the gold standard. Statistical analysis was performed. RESULTS Nasion-Point A was significantly different from the gold standard in all methods. More statistically significant differences were found on the measurements of the 3 m SMD cephalograms in comparison to the other methods. Intra- and inter-observer agreement based on 3D measurements was slightly better than others. LIMITATIONS Dry human skulls without soft tissues were used. Therefore, the results have to be interpreted with caution, as they do not fully represent clinical conditions. CONCLUSIONS 3D measurements resulted in a better observer agreement. The accuracy of the measurements based on CBCT and 1.5 m SMD cephalogram was better than a 3 m SMD cephalogram. These findings demonstrated the linear measurements accuracy and reliability of 3D measurements based on CBCT data when compared to 2D techniques. Future studies should focus on the implementation of 3D cephalometry in clinical practice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Measurements of the natural background radiation have been made at numerous places throughout the world. Very little work in this field has been done in developing countries. In Mexico the natural radiation to which the population is exposed has not been assessed. This dissertation represents a pioneer study in this environmental area. The radiation exposure which occupants within buildings receive as a result of naturally occurring radionuclides present in construction materials is the principal focus.^ Data were collected between August 1979 and November 1980. Continuous monitoring was done with TLDs placed on site for periods of 3 to 6 months. The instrumentation used for "real-time" measurements was a portable NaI (Tl) scintillation detector. In addition, radiometric measurements were performed on construction materials commonly used in Mexican homes.^ Based on TLD readings taken within 75 dwellings, the typical indoor exposure for a resident of the study area is 9.2 (mu)Rh('-1). The average reading of the 152 indoor scintillometer surveys was 9.5 (mu)Rh('-1), the outdoor reading 7.5 (mu)Rh('-1). Results of one-way and multi-way analyses of the exposure data to determine the effect due to building materials type, geologic subsoil, age of dwelling, and elevation are also presented. The results of 152 indoor scintillometer surveys are described. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Impact and monitoring of dredge spoils are an important environmental issue. This investigation aims to map two dredge-spoil dispersals in the Bay of Seine by using an innovative application of well-established environmental magnetic proxies. Low-field magnetic susceptibility measurements were performed on discrete samples from dredge sediments and from the Bay of Seine seafloor before & after dumping. The fingerprinting of the dispersion of dredge-dumped sediments is efficient due to the higher susceptibility of the dredge sediments with respect to the background. Besides, terrestrial input is also monitored in our susceptibility maps. Dilution of the susceptibility signal allows an estimation of the resilience of the sedimentary environment on a six-month survey. This susceptibility signal is controlled by the ferromagnetic fraction of the sediment. A constant magnetic mineralogy carried by magnetite is observed in the study area, thus a qualitative parameter for magnetic grain size was selected that shows an in-progress resilience pattern over the survey.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

On 20 March 2015, a total solar eclipse occurred over Ny-Ålesund (78.9° N, 11.9° E), Svalbard, in the high Arctic. It was the first time that the surface radiation components during the totality of a solar eclipse were measured by a Baseline Surface Radiation Network (BSRN) station. With the Ny-Ålesund long-term radiation data set as background (available at doi:10.1594/PANGAEA.150000), we present here the peculiarities of the radiation components and basic meteorology observed during the eclipse event. The supplementary data set contains the basic BSRN radiation and surface meteorological data in 1 min resolution for March 2015, and is available at doi:10.1594/PANGAEA.854326. The eclipse radiation data will be a useful auxiliary data set for further studies on micrometeorological surface-atmosphere exchange processes in the Svalbard environment, and may serve as a test case for radiative transfer studies.