869 resultados para BALTIC-GAS
Resumo:
Data on contents and compositions of hydrocarbons (HCs)-aliphatic (AHCs) and polycyclic aromatic (PAHs) are provided in comparison with contents of total organic carbon (Corg), lipids in suspended matter, and Corg in bottom sediments. Particular attention is paid to distribution of HCs in the area of the Kravtsov oil field. It is established that concentrations of AHCs in water are governed by concentrations of suspended matter and elevated AHC concentrations are confined to coastal areas. In the area of D-6 platform sandy bottom sediments are notable for great variability of HC concentrations, both laterally and from year to year. In summer of 2010 average content of AHCs was 40 ppm (19% of Corg) and that of PAHs was 0.023 ppm. Natural seepage from sediment mass is considered to be a source of HCs along with oil contamination.
Resumo:
The estimation of the carbon dioxide (CO2) fluxes above the open ocean plays an important role for the determination of the global carbon cycle. A frequently used method therefore is the eddy-covariance technique, which is based on the theory of the Prandl-layer with height-constant fluxes in the atmospheric boundary layer. To test the assumption of the constant flux layer, in 2008 measurements of turbulent heat and CO2 fluxes were started within the project Surface Ocean Processes in the Anthropocene (SOPRAN) at the research platform FINO2. The FINO2 platform is situated in the South-west of the Baltic Sea, in the tri-border region between Germany, Denmark, and Sweden. In the frame of the Research project SOPRAN, the platform was equipped with additional sensors in June 2008. A combination of 3-component sonic anemometers (USA-1) and open-path infrared gas analyzers for absolute humidity (H2O) and CO2 (LICOR 7500) were installed at a 9m long boom directed southward of the platform in two heights, at 6.8 and 13.8m above sea surface. Additionally slow temperature and humidity sensors were installed at each height. The gas analyzer systems were calibrated before the installation and worked permanently without any calibration during the first measurement period of one and a half years. The comparison with the measurements of the slow sensors showed for both instruments no significant long-term drift in H2O and CO2. Drifts on smaller time scales (in the order of days) due to the contamination with sea salt, were cleaned naturally by rain. The drift of both quantities had no influence on the fluctuation, which, in contrast to the mean values, are important for the flux estimation. All data were filtered due to spikes, rain, and the influence of the mast. The data set includes the measurements of all sensors as average over 30 minutes each for one and a half years, June 2008 to December 2009, and 10 month from November 2011 to August 2012. Additionally derived quantities for 30 minutes intervals each, like the variances for the fast-sensor variables, as well as the momentum, sensible and latent heat, and CO2 flux are presented.
Resumo:
A miniaturised gas analyser is described and evaluated based on the use of a substrate-integrated hollow waveguide (iHWG) coupled to a microsized near-infrared spectrophotometer comprising a linear variable filter and an array of InGaAs detectors. This gas sensing system was applied to analyse surrogate samples of natural fuel gas containing methane, ethane, propane and butane, quantified by using multivariate regression models based on partial least square (PLS) algorithms and Savitzky-Golay 1(st) derivative data preprocessing. The external validation of the obtained models reveals root mean square errors of prediction of 0.37, 0.36, 0.67 and 0.37% (v/v), for methane, ethane, propane and butane, respectively. The developed sensing system provides particularly rapid response times upon composition changes of the gaseous sample (approximately 2 s) due the minute volume of the iHWG-based measurement cell. The sensing system developed in this study is fully portable with a hand-held sized analyser footprint, and thus ideally suited for field analysis. Last but not least, the obtained results corroborate the potential of NIR-iHWG analysers for monitoring the quality of natural gas and petrochemical gaseous products.
Resumo:
Plackett-Burman experimental design was applied for the robustness assessment of GC×GC-qMS (Comprehensive Two-Dimensional Gas Chromatography with Fast Quadrupolar Mass Spectrometric Detection) in quantitative and qualitative analysis of volatiles compounds from chocolate samples isolated by headspace solid-phase microextraction (HS-SPME). The influence of small changes around the nominal level of six factors deemed as important on peak areas (carrier gas flow rate, modulation period, temperature of ionic source, MS photomultiplier power, injector temperature and interface temperature) and of four factors considered as potentially influential on spectral quality (minimum and maximum limits of the scanned mass ranges, ions source temperature and photomultiplier power). The analytes selected for the study were 2,3,5-trimethylpyrazine, 2-octanone, octanal, 2-pentyl-furan, 2,3,5,6-tetramethylpyrazine, and 2-nonanone e nonanal. The factors pointed out as important on the robustness of the system were photomultiplier power for quantitative analysis and lower limit of mass scanning range for qualitative analysis.
Resumo:
Traveling wave ion mobility mass spectrometry (TWIM-MS) is shown to be able to separate and characterize several isomeric forms of diterpene glycosides stevioside (Stv) and rebaudioside A (RebA) that are cationized by Na(+) and K(+) at different sites. Determination and characterization of these coexisting isomeric species, herein termed catiomers, arising from cationization at different and highly competitive coordinating sites, is particularly challenging for glycosides. To achieve this goal, the advantage of using CO2 as a more massive and polarizable drift gas, over N2 , was demonstrated. Post-TWIM-MS/MS experiments were used to confirm the separation. Optimization of the possible geometries and cross-sectional calculations for mobility peak assignments were also performed. Copyright © 2015 John Wiley & Sons, Ltd.
Resumo:
In this work, we discuss the use of multi-way principal component analysis combined with comprehensive two-dimensional gas chromatography to study the volatile metabolites of the saprophytic fungus Memnoniella sp. isolated in vivo by headspace solid-phase microextraction. This fungus has been identified as having the ability to induce plant resistance against pathogens, possibly through its volatile metabolites. Adequate culture media was inoculated, and its headspace was then sampled with a solid-phase microextraction fiber and chromatographed every 24 h over seven days. The raw chromatogram processing using multi-way principal component analysis allowed the determination of the inoculation period, during which the concentration of volatile metabolites was maximized, as well as the discrimination of the appropriate peaks from the complex culture media background. Several volatile metabolites not previously described in the literature on biocontrol fungi were observed, as well as sesquiterpenes and aliphatic alcohols. These results stress that, due to the complexity of multidimensional chromatographic data, multivariate tools might be mandatory even for apparently trivial tasks, such as the determination of the temporal profile of metabolite production and extinction. However, when compared with conventional gas chromatography, the complex data processing yields a considerable improvement in the information obtained from the samples. This article is protected by copyright. All rights reserved.
Resumo:
In this communication we describe the application of a conductive polymer gas sensor as an air pressure sensor. The device consists of a thin doped poly(4'-hexyloxy-2,5-biphenylene ethylene) (PHBPE) film deposited on an interdigitated metallic electrode. The sensor is cheap, easy to fabricate, lasts for several months, and is suitable for measuring air pressures in the range between 100 and 700 mmHg.
Resumo:
Gas-phase SiCl3+ ions undergo sequential solvolysis type reactions with water, methanol, ammonia, methylamine and propylene. Studies carried out in a Fourier Transform mass spectrometer reveal that these reactions are facile at 10-8 Torr and give rise to substituted chlorosilyl cations. Ab initio and DFT calculations reveal that these reactions proceed by addition of the silyl cation to the oxygen or nitrogen lone pair followed by a 1,3-H migration in the transition state. These transition states are calculated to lie below the energy of the reactants. By comparison, hydrolysis of gaseous CCl3+ is calculated to involve a substantial positive energy barrier.
Resumo:
The aggregation of interacting Brownian particles in sheared concentrated suspensions is an important issue in colloid and soft matter science per se. Also, it serves as a model to understand biochemical reactions occurring in vivo where both crowding and shear play an important role. We present an effective medium approach within the Smoluchowski equation with shear which allows one to calculate the encounter kinetics through a potential barrier under shear at arbitrary colloid concentrations. Experiments on a model colloidal system in simple shear flow support the validity of the model in the concentration range considered. By generalizing Kramers' rate theory to the presence of shear and collective hydrodynamics, our model explains the significant increase in the shear-induced reaction-limited aggregation kinetics upon increasing the colloid concentration.