944 resultados para Axial loads
Resumo:
Stone masonry is one of the oldest and most worldwide used building techniques. Nevertheless, the structural response of masonry structures is complex and the effective knowledge about their mechanical behaviour is still limited. This fact is particularly notorious when dealing with the description of their out-of-plane behaviour under horizontal loadings, as is the case of the earthquake action. In this context, this paper describes an experimental program, conducted in laboratory environment, aiming at characterizing the out-of-plane behaviour of traditional unreinforced stone masonry walls. In the scope of this campaign, six full-scale sacco stone masonry specimens were fully characterised regarding their most important mechanic, geometric and dynamic features and were tested resorting to two different loading techniques under three distinct vertical pre-compression states; three of the specimens were subjected to an out-of-plane surface load by means of a system of airbags and the remaining were subjected to an out-of-plane horizontal line-load at the top. From the experiments it was possible to observe that both test setups were able to globally mobilize the out-of-plane response of the walls, which presented substantial displacement capacity, with ratios of ultimate displacement to the wall thickness ranging between 26 and 45 %, as well as good energy dissipation capacity. Finally, very interesting results were also obtained from a simple analytical model used herein to compute a set of experimental-based ratios, namely between the maximum stability displacement and the wall thickness for which a mean value of about 60 % was found.
Resumo:
Apresentam-se os resultados de 62 exames cineangiocardiográficos registados em projecções axiais referentes a 52 crianças internadas por cardiopatia congénita na Unidade de Cardiologia Pediátrica dos Hospitais Civis de Lisboa. Os diagnósticos mais frequentes foram: defeitos atrioventriculares, tetralogia de Fallot e comunicação interventricular isolada. Dos resultados, a grande maioria dos exames permitiu uma definição clara das estruturas visualizáveis na projecção utilizada. Conclui-se que, com uma selecção criteriosa das projecções a utilizar, é possível diminuir de modo muito significativo a necessidade de repetir exames por diagnóstico incompleto e, com o auxílio das projecções axiais, obter informação detalhada sobre a morfologia das cardiopatias congénitas.
Longitudinal comparison between plasma and seminal HIV-1 viral loads during antiretroviral treatment
Resumo:
This study was designed to investigate the impact of anti-retroviral therapy on both plasma and seminal HIV-1 viral loads and the correlation between viral loads in these compartments after treatment. Viral load, CD4+ and CD8+ T-cell counts were evaluated in paired plasma and semen samples from 36 antiretroviral therapy-naïve patients at baseline and on days 45, 90, and 180 of treatment. Slopes for blood and seminal viral loads in all treated patients were similar (p = 0.21). Median HIV-1 RNA titers in plasma and semen at baseline were 4.95 log10 and 4.48 log10 copies/ml, respectively. After 180 days of therapy, the median viral load declined to 3.15 log10 copies/ml (plasma) and 3.2 log10 copies/ml (semen). At this timepoint 22 patients presented HIV-1 viral load below 400 copies/ml in either plasma or semen, but only 9 had viral loads below 400 copies/ml in both compartments.
Resumo:
This paper presents the design and the prototype implementation of a three-phase power inverter developed to drive a motor-in-wheel. The control system is implemented in a FPGA (Field Programmable Gate Array) device. The paper describes the Field Oriented Control (FOC) algorithm and the Space Vector Modulation (SVM) technique that were implemented. The control platform uses a Spartan-3E FPGA board, programmed with Verilog language. Simulation and experimental results are presented to validate the developed system operation under different load conditions. Finally are presented conclusions based on the experimental results.
Resumo:
Electric Vehicles (EVs) are increasingly used nowadays, and different powertrain solutions can be adopted. This paper describes the control system of an axial flux Permanent Magnet Synchronous Motor (PMSM) for EVs powertrain. It is described the implemented Field Oriented Control (FOC) algorithm and the Space Vector Modulation (SVM) technique. Also, the mathematical model of the PMSM is presented. Both, simulation and experimental, results with different types of mechanical load are presented. The experimental results were obtained using a laboratory test bench. The obtained results are discussed.
Resumo:
This paper presents and discusses the results of the serviciability and use condition tests carried on an innovative solution for partitions, designated AdjustMembrane developed within a research project. The proposed system is a modular non-loadbearing wall, tensioned between the pavements and ceiling slabs, which are used as anchoring elements. It allows several advantages, related with the weight reduction to achieve a good sustainable performance, such as the reduction of construction costs, energy, and materials, and it is easy to recycle and to reuse, allowing self-construction. Apart from a general presentation of the partition technology, this paper presents and discusses the results of experimental tests carried out. From the results obtained, it is possible to conclude that the solution fulfils the requirements for this typology of wall in terms of resistance to horizontal loads induced by soft and hard body impacts.
Resumo:
The obesity prevalence is increasing among the workforce of the developed countries. However, obesity seems to negatively affect the individuals’ work performance. In occupational contexts, manual lifting tasks are frequent and can produce significant muscle loading. With the aim of analysing the possible effect of obesity on workers’ muscular activation, surface electromyography data were collected from six muscles recruited during these tasks. In the current study, 6 different tasks of manual lifting (3 loads × 2 lifting styles) were performed by 14 participants with different obesity levels. Electromyography data normalization was based on the percentage of maximum contraction during each task. The muscles’ activation times before each task were also calculated. The current study suggests that obesity can increase the maximum contraction during each task and the delays on muscles’ activation time. This study suggests that obese individuals can present some changes on their muscle activation during lifting, when comparing with non-obese individuals, and reinforces the need to develop further studies focused on obesity as a risk factor for musculoskeletal disorders development.
Resumo:
The present study proposes a dynamic constitutive material interface model that includes non-associated flow rule and high strain rate effects, implemented in the finite element code ABAQUS as a user subroutine. First, the model capability is validated with numerical simulations of unreinforced block work masonry walls subjected to low velocity impact. The results obtained are compared with field test data and good agreement is found. Subsequently, a comprehensive parametric analysis is accomplished with different joint tensile strengths and cohesion, and wall thickness to evaluate the effect of the parameter variations on the impact response of masonry walls.
Resumo:
Dissertação de mestrado integrado em Engenharia Eletrónica Industrial e de Computadores
Resumo:
Magdeburg, Univ., Fak. für Maschinenbau, Diss., 2015
Resumo:
Magdeburg, Univ., Fak. für Verfahrens- und Systemtechnik, Diss., 2015
Resumo:
To compare the impact of meeting specific classification criteria [modified New York (mNY), European Spondyloarthropathy Study Group (ESSG), and Assessment of SpondyloArthritis international Society (ASAS) criteria] on anti-tumor necrosis factor (anti-TNF) drug retention, and to determine predictive factors of better drug survival. All patients fulfilling the ESSG criteria for axial spondyloarthritis (SpA) with available data on the axial ASAS and mNY criteria, and who had received at least one anti-TNF treatment were retrospectively retrieved in a single academic institution in Switzerland. Drug retention was computed using survival analysis (Kaplan-Meier), adjusted for potential confounders. Of the 137 patients classified as having axial SpA using the ESSG criteria, 112 also met the ASAS axial SpA criteria, and 77 fulfilled the mNY criteria. Drug retention rates at 12 and 24 months for the first biologic therapy were not significantly different between the diagnostic groups. Only the small ASAS non-classified axial SpA group (25 patients) showed a nonsignificant trend toward shorter drug survival. Elevated CRP level, but not the presence of bone marrow edema on magnetic resonance imaging (MRI) scans, was associated with significantly better drug retention (OR 7.9, ICR 4-14). In this cohort, anti-TNF drug survival was independent of the classification criteria. Elevated CRP level, but not positive MRI, was associated with better drug retention.
Resumo:
PURPOSE: To assess the impact of axial traction during acquisition of direct magnetic resonance (MR) arthrography of the wrist with regard to joint space width and amount of contrast material between the opposing cartilage surfaces. MATERIALS AND METHODS: Fifteen consecutive patients (12 male, mean age 38.1 years) were included in this Institutional Review Board-approved prospective study. Three-compartment wrist MR arthrographies were performed between October and December 2009 on a 3 T unit using a fat-suppressed T1-weighted isotropic high-resolution volumetric interpolated breathhold examination (VIBE) sequence in the coronal plane, with and without axial traction (3 kg). Two radiologists measured radiocarpal (radioscaphoid, radiolunate) and midcarpal (lunocapitate, hamatolunate) joint space widths, with and without traction, and assessed the amount of contrast material between the opposing cartilage surfaces using a three-point scale: 0 = absence, 1 = partial, 2 = complete. RESULTS: With traction, joint space width increased significantly at the radioscaphoid (Delta = 0.78 mm, P < 0.01), radiolunate (Delta = 0.18 mm, P < 0.01), and lunocapitate (Delta = 0.45 mm, P < 0.01) spaces, and both observers detected significantly more contrast material between the cartilage surfaces. At the hamatolunate space, the differences in joint space width (Delta = 0.14 mm, P = 0.54) and amount of contrast material were not significant. CONCLUSION: Direct wrist MR arthrography with axial traction of 3 kg increases joint space width at the radiocarpal and lunocapitate spaces, and prompts better coverage of the articular cartilage by the contrast material. J. Magn. Reson. Imaging 2011;. (c) 2011 Wiley-Liss, Inc.
Resumo:
Objectives:¦The aim of this study was to estimate the prevalence of subclinical small joint synovitis detected by ultrasonography in patients with axial SpA, and to evaluate their relevance in terms of function or and disease activity.¦Methods:¦Forty axial SpA patients, 40 RA and 20 healthy subjects were evaluated by ultrasonography, using a reproducible semi-quantitative score by B-mode and Doppler, for synovitis, while disease activity and function were assessed using validated instruments (DAS28, BASDAI, BASFI, m-SACRAH and HAQ).¦Results:¦Median B-mode score were respectively 8.2 for axial SpA, 11.5 for RA and 6.0 for healthy subjects, corresponding to a prevalence of clinical significant synovitis of respectively 37.5%, 60% and 11% for a level of significance at > 8 chosen to¦classify as active > 75% of RA patient with DAS28 >2.6 and < 10% of controls. Addtionally, Doppler was positive in 8% of SpA, 30 % of RA and none of the healthy subjects. Echographic synovitis correlated with disease activity (DAS28) and function¦(HAQ, mSACRAH) in RA patients, but no correlation were found for SpA patients with disease activity (BASDAI) or function (BASFI, HAQ, mSACRAH). Cases of synovitis using classification by Doppler positivity were insufficient to allow any¦statistical analysis.¦Conclusions:¦B-mode ultrasonographic evaluation can demonstrate subclinical synovitis in almost 40% of SpA patients, but they do not appear to correlate with disease activity or function on the contrary to what is observed in RA patients, representing potentially different processes
Resumo:
Background: patients with axial Spondyloarthritis (SD), even withoutany obvious peripheral joint synovitis, often complain of pain in thejoints of arms and legs. Several musculoskeletal ultrasound (US)scores developed in rheumatoid arthritis have demonstrated theircapacity of discovering subclinical synovitis which were relevant interm of disease activity and for treatment strategies. None of thesescores however have been, to our knowledge, applied tospondyloarthritis patients.Objectives: to determine if subclinical synovitis can be detected byechography in patients with SD and if these synovitis are relevantcompared with RA and controls.Methods: the Swiss Sonography in Arthritis and Rheumatism(SONAR) group has developed a reproducible semi-quantitative scorefor RA using OMERACT criteria for synovitis. The score includes Bmode and Doppler mode. 35 out of 40 enrolled SD patients fulfillingthe 2010 diagnostic criteria were evaluated according to the SONARscore. In none of them, peripheral synovitis was clearly demonstrated,although some have or reported recurrent peripheral joint pain. Thescore was also applied to 20 matched controls and 40 consecutive RApatients (RA). 19 of them were in remission (DAS: <2.6), 10 with alow activity (DAS: 2.6 <>3.4) and 11 with a moderate activity disease(DAS: 3.5 <>5.1). All the patients and the controls had a completeclinical, biological and auto-evaluation assessment (joint pain andswelling counts, DAS28, HAQ, BASDAI BASMI, BASFI, m-SACRAH).The ultra-sonographer was blind to all these parameters.Results: a B mode score >8, was set up as a cut-off value forsignificant synovitis as only 10% of the controls (median: 5.9 ± 2.2)and 90% of active RA had a higher score .34% of SD had significantsynovitis which remained mostly mild. Their median B mode score(12 ± 1.6) was higher but not significantly than in remission Ra (7.1 ±3.4). Only active RA (DAS >3.5) had significant higher echographicscores: B mode (17 ± 11), Doppler score and cumulative score forsynovitis grade >1. BASDAI, BASFI, BASMI, m-SACRAH, DAS28 andCRP were not significantly different in SD patients with or withoutsynovitis.Conclusions: some patients with axial Spondyloarthritis havesubclinical but significant peripheral synovitis detected by echography.The impact of these synovitis remains uncertain as their presencedoes not seem to significantly influence disease activity and functionevaluation tools.