672 resultados para Aspheric collimating lens


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To establish risk factors for moderate and severe microbial keratitis among daily contact lens (CL) wearers in Australia. Design: A prospective, 12-month, population-based, case-control study. Participants: New cases of moderate and severe microbial keratitis in daily wear CL users presenting in Australia over a 12-month period were identified through surveillance of all ophthalmic practitioners. Case detection was augmented by record audits at major ophthalmic centers. Controls were users of daily wear CLs in the community identified using a national telephone survey. Testing: Cases and controls were interviewed by telephone to determine subject demographics and CL wear history. Multiple binary logistic regression was used to determine independent risk factors and univariate population attributable risk percentage (PAR%) was estimated for each risk factor.; Main Outcome Measures: Independent risk factors, relative risk (with 95% confidence intervals [CIs]), and PAR%. Results: There were 90 eligible moderate and severe cases related to daily wear of CLs reported during the study period. We identified 1090 community controls using daily wear CLs. Independent risk factors for moderate and severe keratitis while adjusting for age, gender, and lens material type included poor storage case hygiene 6.4× (95% CI, 1.9-21.8; PAR, 49%), infrequent storage case replacement 5.4× (95% CI, 1.5-18.9; PAR, 27%), solution type 7.2× (95% CI, 2.3-22.5; PAR, 35%), occasional overnight lens use (<1 night per week) 6.5× (95% CI, 1.3-31.7; PAR, 23%), high socioeconomic status 4.1× (95% CI, 1.2-14.4; PAR, 31%), and smoking 3.7× (95% CI, 1.1-12.8; PAR, 31%). Conclusions: Moderate and severe microbial keratitis associated with daily use of CLs was independently associated with factors likely to cause contamination of CL storage cases (frequency of storage case replacement, hygiene, and solution type). Other factors included occasional overnight use of CLs, smoking, and socioeconomic class. Disease load may be considerably reduced by attention to modifiable risk factors related to CL storage case practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Transient hyperopic refractive shifts occur on a timescale of weeks in some patients after initiation of therapy for hyperglycemia, and are usually followed by recovery to the original refraction. Possible lenticular origin of these changes is considered in terms of a paraxial gradient index model. Assuming that the lens thickness and curvatures remain unchanged, as observed in practice, it appears possible to account for initial hyperopic refractive shifts of up to a few diopters by reduction in refractive index near the lens center and alteration in the rate of change between center and surface, so that most of the index change occurs closer to the lens surface. Restoration of the original refraction depends on further change in the refractive index distribution with more gradual changes in refractive index from the lens center to its surface. Modeling limitations are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. The purpose of this article was to present methods capable of estimating the size and shape of the human eye lens without resorting to phakometry or magnetic resonance imaging (MRI). Methods. Previously published biometry and phakometry data of 66 emmetropic eyes of 66 subjects (age range [18, 63] years, spherical equivalent range [−0.75, +0.75] D) were used to define multiple linear regressions for the radii of curvature and thickness of the lens, from which the lens refractive index could be derived. MRI biometry was also available for a subset of 30 subjects, from which regressions could be determined for the vertex radii of curvature, conic constants, equatorial diameter, volume, and surface area. All regressions were compared with the phakometry and MRI data; the radii of curvature regressions were also compared with a method proposed by Bennett and Royston et al. Results. The regressions were in good agreement with the original measurements. This was especially the case for the regressions of lens thickness, volume, and surface area, which each had an R2 > 0.6. The regression for the posterior radius of curvature had an R2 < 0.2, making this regression unreliable. For all other regressions we found 0.25 < R2 < 0.6. The Bennett-Royston method also produced a good estimation of the radii of curvature, provided its parameters were adjusted appropriately. Conclusions. The regressions presented in this article offer a valuable alternative in case no measured lens biometry values are available; however care must be taken for possible outliers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Design Science Research Roadmap (DSR-Roadmap) [1] aims to give detailed methodological guidance to novice researchers in Information Systems (IS) DSR. Focus group evaluation, one phase of the overall study, of the evolving DSR-Roadmap revealed that a key difficulty faced by both novice and expert researchers in DSR, is abstracting design theory from design. This paper explores the extension of the DSR-Roadmap by employing IS deep structure ontology (BWW [2-4]) as a lens on IS design to firstly yield generalisable design theory, specifically 'IS Design Theory' (ISDT) elements [5]. Consideration is next given to the value of BWW in the application of the design theory by practitioners. Results of mapping BWW constructs to ISDT elements suggest that the BWW is promising as a common language between design researchers and practitioners, facilitating both design theory and design implementation

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electrospun scaffolds manufactured using conventional electrospinning configurations have an intrinsic thickness limitation, due to a charge build-up at the collector. To overcome this limitation, an electrostatic lens has been developed that, at the same relative rate of deposition, focuses the polymer jet onto a smaller area of the collector, resulting in the fabrication of thick scaffolds within a shorter period of time. We also observed that a longer deposition time (up to 13 h, without the intervention of the operator) could be achieved when the electrostatic lens was utilised, compared to 9–10 h with a conventional processing set-up and also showed that fibre fusion was less likely to occur in the modified method. This had a significant impact on the mechanical properties, as the scaffolds obtained with the conventional process had a higher elastic modulus and ultimate stress and strain at short times. However, as the thickness of the scaffolds produced by the conventional electrospinning process increased, a 3-fold decrease in the mechanical properties was observed. This was in contrast to the modified method, which showed a continual increase in mechanical properties, with the properties of the scaffold finally having similar mechanical properties to the scaffolds obtained via the conventional process at longer times. This “focusing” device thus enabled the fabrication of thicker 3-dimensional electrospun scaffolds (of thicknesses up to 3.5 mm), representing an important step towards the production of scaffolds for tissue engineering large defect sites in a multitude of tissues.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sector wide interest in Reframe: QUT’s Evaluation Framework continues with a number of institutions requesting finer details as QUT embeds the new approach to evaluation across the university in 2013. This interest, both nationally and internationally has warranted QUT’s collegial response to draw upon its experiences from developing Reframe into distilling and offering Kaleidoscope back to the sector. The word Reframe is a relevant reference for QUT’s specific re-evaluation, reframing and adoption of a new approach to evaluation; whereas Kaleidoscope reflects the unique lens through which any other institution will need to view their own cultural specificity and local context through an extensive user-led stakeholder engagement approach when introducing new approaches to learning and teaching evaluation. Kaleidoscope’s objectives are for QUT to develop its research-based stakeholder approach to distil the successful experience exhibited in the Reframe Project into a transferable set of guidelines for use by other tertiary institutions across the sector. These guidelines will assist others to design, develop, and deploy, their own culturally specific widespread organisational change informed by stakeholder engagement and organisational buy-in. It is intended that these guidelines will promote, support and enable other tertiary institutions to embark on their own evaluation projects and maximise impact. Kaleidoscope offers an institutional case study of widespread organisational change underpinned by Reframe’s (i) evidence-based methodology; (ii) research including published environmental scan, literature review (Alderman, et al., 2012), development of a conceptual model (Alderman, et al., in press 2013), project management principles (Alderman & Melanie, 2012) and national conference peer reviews; and (iii) year-long strategic project with national outreach to collaboratively engage the development of a draft set of National Guidelines. Kaleidoscope’s aims are to inform Higher Education evaluation policy development through national stakeholder engagement, the finalisation of proposed National Guidelines. In correlation with the conference paper, the authors will present a Draft Guidelines and Framework ready for external peer review by evaluation practitioners from the Higher Education sector, as part of Kaleidoscope’s dissemination strategy (Hinton & Gannaway, 2011) applying illuminative evaluation theory (Parlett & Hamilton, 1976), through conference workshops and ongoing discussions (Shapiro, et al., 1983; Jacobs, 2000). The initial National Guidelines will be distilled from the Reframe: QUT’s Evaluation Framework’s Policy, Protocols, and incorporated Business Rules. It is intended that the outcomes of Kaleidoscope are owned by and reflect sectoral engagement, including iterative evaluation through multiple avenues of dissemination and collaboration including the Higher Education sector. The dissemination strategy with the inclusion of Illuminative Evaluation methodology provides an inclusive opportunity for other institutions and stakeholders across the Higher Education sector to give voice through the information-gathering component of evaluating the draft Guidelines, providing a comprehensive understanding of the complex realities experienced across the Higher Education sector, and thereby ‘illuminating’ both the shared and unique lenses and contexts. This process will enable any final guidelines developed to have broader applicability, greater acceptance, enhanced sustainability and additional relevance benefiting the Higher Education sector, and the adoption and adaption by any single institution for their local contexts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Within the Australian higher education sector, institutions are required to evaluate teaching, units and courses to assure the quality of the student learning experience, however with hardly any regulatory parameters guiding institutions, and with disparate practices, there are few opportunities to benchmakr across institutions or the sector. QUT has received interest and requests from national and international universities on accessing Reframe: QUT's Evaluation Framework.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lens average and equivalent refractive indices are required for purposes such as lens thickness estimation and optical modeling. We modeled the refractive index gradient as a power function of the normalized distance from lens center. Average index along the lens axis was estimated by integration. Equivalent index was estimated by raytracing through a model eye to establish ocular refraction, and then backward raytracing to determine the constant refractive index yielding the same refraction. Assuming center and edge indices remained constant with age, at 1.415 and 1.37 respectively, average axial refractive index increased (1.408 to 1.411) and equivalent index decreased (1.425 to 1.420) with age increase from 20 to 70 years. These values agree well with experimental estimates based on different techniques, although the latter show considerable scatter. The simple model of index gradient gives reasonable estimates of average and equivalent lens indices, although refinements in modeling and measurements are required.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose The aim was to determine the extent of daily disposable contact lens prescribing worldwide and to characterise the associated demographics and fitting patterns. Methods Up to 1,000 survey forms were sent to contact lens fitters in up to 40 countries between January and March every year for five consecutive years (2007 to 2011). Practitioners were asked to record data relating to the first 10 contact lens fits or refits performed after receiving the survey form. Survey data collected since 1996 were also analysed for seven nations to assess daily disposable lens fitting trends since that time. Results Data were collected in relation to 97,289 soft lens fits, of which 23,445 (24.1 per cent) were with daily disposable lenses and 73,170 (75.9 per cent) were with reusable lenses. Daily disposable lens prescribing ranged from 0.6 per cent of all soft lenses in Nepal to 66.2 per cent in Qatar. Compared with reusable lens fittings, daily disposable lens fittings can be characterised as follows: older age (30.0 ± 12.5 versus 29.3 ± 12.3 years for reusable lenses); males are over-represented; a greater proportion of new fits versus refits; 85.9 per cent hydrogel; lower proportion of toric and presbyopia designs and a higher proportion of part-time wear. There has been a continuous increase in daily disposable lens prescribing between 1996 and 2011. The proportion of daily disposable lens fits (as a function of all soft lens fits) is positively related to the gross domestic product at purchasing power parity per capita (r2 = 0.55, F = 46.8, p < 0.0001). Conclusions The greater convenience and other benefits of daily disposable lenses have resulted in this modality capturing significant market share. The contact lens field appears to be heading toward a true single-use-only, disposable lens market.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Moderator Opening The early focus of contact lens wear and ocular health was on oxygen delivery. However, as we learn more about how the eye works, and investigate how the contact lens interacts with the cornea, the role of the tear film has risen in prominence. A healthy tear film is critical for normal ocular homeostasis, and abnormalities of the tear film are the primary cause of dry eye. In order to improve patient eye health and comfort during lens wear, we need to further elucidate the relationship among contact lenses, contact lens solutions, the tear film, and the corneal epithelium, and find ways to maintain homeostasis of the ocular surface. In this section, we review the latest data and opinions on this complex relationship between contact lenses and lens care solutions

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Eye care practitioners (ECPs) would tend to agree that wearing contact lenses increases the risk for infection, but millions of patients are still fitted with lenses every year because ECPs feel that the risk is manageable and that their patients' eye health can be protected. The Fusarium and Acanthamoeba keratitis outbreaks of years past were a wake-up call to manufacturers, ECPs, and regulatory agencies that risk cannot be managed without diligence, and that the complex relationship between contact lens materials, contact lens solutions, and compliance needs to be better understood in order to optimize the efficacy of contact lens care and improve care guidelines.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose To determine the extent of rigid contact lens fitting worldwide and to characterize the associated demographics and fitting patterns. Methods Survey forms were sent to contact lens fitters in up to 40 countries between January and March every year for five consecutive years (2007 to 2011). Practitioners were asked to record data relating to the first 10 contact lens fits or refits performed after receiving the survey form. Survey data collected between 1996 and 2011 were also analyzed to assess rigid lens fitting trends in seven nations during this period. Results Data were obtained for 12,230 rigid and 100,670 soft lens fits between 2007 and 2011. Overall, rigid lenses represented 10.8% of all contact lens fits, ranging from 0.2% in Lithuania to 37% in Malaysia. Compared with soft lens fits, rigid lens fits can be characterized as follows: older age (rigid, 37.3 ± 15.0 years; soft, 29.8 ± 12.4 years); fewer spherical and toric fits; more bifocal/multifocal fits; less frequent replacement (rigid, 7%; soft, 85%); and less part-time wear (rigid, 4%; soft, 10%). High-Dk (contact lens oxygen permeability) (36%) and mid-Dk (42%) materials are predominantly used for rigid lens fitting. Orthokeratology represents 11.5% of rigid contact lens fits. There has been a steady decline in rigid lens fitting between 1996 and 2011. Conclusions Rigid contact lens prescribing is in decline but still represents approximately 10% of all contact lenses fitted worldwide. It is likely that rigid lenses will remain as a viable, albeit increasingly specialized, form of vision correction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives To characterize toric contact lens prescribing worldwide. Methods Up to 1,000 survey forms were sent to contact lens fitters in up to 39 countries between January and March every year for 5 consecutive years (2007–2011). Practitioners were asked to record data relating to the first 10 contact lens fits or refits performed after receiving the survey form. Only data for toric and spherical soft lens fits were analyzed. Survey data collected since 1996 were also analyzed for 7 nations to assess toric lens fitting trends since that time. Results Data were collected in relation to 21,150 toric fits (25%) and 62,150 spherical fits (75%). Toric prescribing ranged from 6% of lenses in Russia to 48% in Portugal. Compared with spherical fittings, toric fittings can be characterized as follows: older age (29.8 ± 11.4 years vs. 27.6 ± 10.8 years for spherical lenses); men are overrepresented (38% vs. 34%); greater proportion of new fits (39% vs. 32%); use of silicone hydrogel lenses (49% vs. 39%); and lower proportion of daily disposable lenses (14% vs. 28%). There has been a continuous increase in toric lens prescribing between 1996 and 2011. The proportion of toric lens fits was positively related to the gross domestic product at purchasing power parity per capita for year 2011 (r2 = 0.21; P=0.004). Conclusions At the present time, in the majority of countries surveyed, toric soft contact lens prescribing falls short of that required to correct clinically significant astigmatism (≥0.75 diopters) in all lens wearers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives To characterize and discover the determinants of the frequency of wear (FOW) of contact lenses. Methods Survey forms were sent to contact lens fitters in up to 40 countries between January and March every year for 5 consecutive years (2007–2011). Practitioners were asked to record data relating to the first 10 contact lens fits or refits performed after receiving the survey form. Only data for daily wear lens fits were analyzed. Results Data were collected in relation to 74,510 and 9,014 soft and rigid lens fits, respectively. Overall, FOW was 5.9±1.7 days per week (DPW). When considering the proportion of lenses worn between one to seven DPW, the distribution for rigid lenses is skewed toward full-time wear (7 DPW), whereas the distribution for soft daily disposable lenses is perhaps bimodal, with large and small peaks at seven and two DPW, respectively. There is a significant variation in FOW among nations (P<0.0001), ranging from 6.8±1.0 DPW in Greece to 5.1±2.5 DPW in Kuwait. For soft lenses, FOW increases with decreasing age. Females (6.0±1.6 DPW) wear lenses more frequently than males (5.8±1.7 DPW) (P=0.0002). FOW is greater among those wearing presbyopic corrections (6.1±1.4 DPW) compared with spherical (5.9±1.7 DPW) and toric (5.9±1.6 DPW) designs (P<0.0001). FOW with hydrogel peroxide systems (6.4±1.1 DPW) was greater than that with multipurpose systems (6.2±1.3 DPW) (P<0.0001). Conclusions Numerous demographic and contact lens–related factors impact FOW. There may be a future trend toward a lower FOW associated with the increasing popularity of daily disposable lenses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The report of this subcommittee concerns the impact of contact lenses (CLs) on the ocular surface, with a particular emphasis on CL discomfort (CLD). We define the ocular surface, its regional anatomy, and the physiological responses of each region to CL wear.