907 resultados para Apprendimento, Automatico, Tris, Scacchi, Annotazioni, Gioco
Resumo:
We described here a new method for the determination of total calcium in plasma. The method is based on the precipitation of calcium with excess oxalate and the measurement of residual oxalate by flow injection analysis with Ru(bpy)(3)(2+) electrochemiluminescent detection. It has the advantages of extremely stable reagent, user-friendly instrument, high selectivity, good analytical recovery, wide dynamic range, and nice correlation with atomic absorption spectroscopy. The calibration plot for calcium is linear over a concentration range from 0.5 mmol L-1 to 4.8 mmol L-1, which is wider than those obtained by most other methods. The analytical recoveries for plasma calcium are 98.4-101.2% with coefficients of variation (CVs) of 1.96-2.52%. The within-day CVs range from 0.76% to 0.95%, and between-day CVs were from 1.12% to 1.46%. The time for each injection is one minute. Because the proposed method can be readily carried out on increasingly popular instruments for Ru(bpy)(3)(2+) ECL immunoassays and DNA probe assays, Ru(bpy)32+ ECL method is suitable for routine clinical analysis of calcium.
Resumo:
An electrochemiluminescence (ECL) sensor with good long-term stability and fast response time has been developed. The sensor was based on the immobilization of tris(2,2'-bipyridyl)ruthenium(II) (Ru(bpy)(3)(2+)) into the Eastman-AQ55D-silica composite thin films on a glassy carbon electrode. The ECL and electrochemistry of Ru(bpy)(3)(2+) immobilized in the composite thin films have been investigated, and the modified electrode was used for the ECL detection of oxalate, tripropylamine (TPA) and chlorpromazine (CPZ) in a flow injection analysis system and showed high sensitivity. Because of the strong electrostatic interaction and low hydrophobicity of Eastman-AQ55D, the sensor showed no loss of response over 2 months of dry storage. In use, the electrode showed only a 5% decrease in response over 100 potential cycles. The detection limit was 1 mumol l(-1) for oxalate and 0.1 mumol l(-1) for both TPA and CPZ (S/N = 3), respectively. The linear range extended from 50 mumol l(-1) to 5 mmol l(-1) for oxalate, from 20 mumol l(-1) to 1 mmol l(-1) for TPA, and from 1 mumol l(-1) to 200 mumol l(-1) for CPZ.
Resumo:
A new multifunctional multilayer films consisting of tris(2,2'-bipyridyl)ruthenium(II) (Rubpy) and sodium decatungstate (W-10) have been prepared by the layer-by-layer (LbL) self-assembly method on ITO substrate. X-ray photoelectron spectra (XPS) confirmed the existence of W10 and Rubpy. Cyclic voltammetry (CV) and UV-Vis spectroscopy demonstrated the uniform assembly of (W-10/Rubpy) multilayer films. The multilayer films possess electrocatalytic activities on the reduction of iodate and oxidation of oxalate. Moreover, the films exhibited electrochemiluminescence (ECL) with tripropylamine (abbreviated as TPA) as the coreactant and the ECL response was proportional to the number of (W-10/Rubpy) layers. These characteristics of the multilayer films might find potential applications in the field of sensors and materials fields.
Resumo:
The design and performance of a miniaturized chip-type tris(2,2'-bipyridyl)ruthenium(II) [Ru(bpy)(3)(2+)] electrochemiluminescence (ECL) detection cell suitable for both capillary electrophoresis (CE) and flow injection (FI) analysis are described. The cell was fabricated from two pieces of glass (20 x 15 x 1.7 mm), and the 0.5-mm-diameter platinum disk was used as working electrode held at +1.15 V (vs silver wire quasi-reference), the stainless steel guide tubing as counter electrode, and the silver wire as quasi-reference electrode. The performance traits of the cell in both CE and FI modes were evaluated using tripropylamine, proline, and oxalate and compared favorably to those reported for CE and FI detection cells. The advantages of versatility, sensitivity, and accuracy make the device attractive for the routine analysis of amine-containing species or oxalate by CE and FI with Ru(bPY)(3)(2divided by) ECL detection.
Resumo:
Capillary electrophoresis (CE) with tris(2,2'-bipyridyl) ruthenium (II) (Ru(bpy)(3)(2+)) electrochemiluminescence (ECL) detection technique was developed for the analysis of four polyamines (putrescine (Put), cadaverine (Cad), spermidine (Spd), and spermine (Spm)) analysis. The four polyamines contain different amine groups, which have different ECL activity. There are several parameters which influence the resolution and ECL peak intensities, including the buffer pH and concentrations, separation voltage, sample injection, electrode materials, and Ru(bpy)(3)(2+) concentrations. Polyamines are separated by capillary zone electrophoresis in an uncoated fused-silica capillary (50 cm x 25 mum (ID) filled with acidic phosphate buffer (200 mmol/L phosphate, pH 2.0) - 1 mol/L phosphoric acid (9:1 v/v) and a separation voltage of 5 kV (25 muA), with end-column Ru(bpy)(3)(2+) ECL detection. A 5 mmol/L Ru(bpy)(3)(2+) solution plus 200 mmol/L phosphate buffer (pH 11.0) is added into the reagent reservoir. The calibration curve is linear over a concentration range of two or three orders of magnitude for the polyamines. The analysis time is less than 25 min. Detection limits for Put and Cad are 1.9 x 10(-7) mol/L and 7.6 x 10(-9) mol/L for Spd and Spm, respectively.
Resumo:
Tris(2,2'-bipyridyl)ruthenium(II) electrochemiluminescence detection in a capillary electrophoresis separation system was used for the determination of diphenhydramine. In this study, platinum disk electrode (300 mum in diameter) was used as a working electrode and the influence of applied potential and buffer conditions were investigated. Under optimal conditions: 1.2 V applied potential, pH 8.50, 15 kV separation voltage and 10 mmol l(-1) running buffer, the calibration curve of diphenhydramine was linear over the range of 4 x 10(-8) to 1 x 10(-5) Mol l(-1). This technique gave satisfactory precision, and relative standard deviations of migration times and chemiluminescence peak intensities were less than 1 and 6%, respectively. The technique was applied to animal studies for determination of diphenhydramine extracted from rabbit plasma and urine samples, and the extraction efficiency were between 92 and 98.5%.
Resumo:
The interaction of DNA with Tris(1,10-phenanthroline) cobalt(III) was studied by means of atomic force microscopy. Changes in the morphologies of DNA complex in the presence of ethanol may well indicate the crucial role of electrostatic force in causing DNA condensation. With the increase of the concentration of ethanol, electrostatic interaction is enhanced corresponding to a lower dielectric constant. Counterions condense along the sugar phosphate backbone of DNA when e is lowered and the phosphate charge density can thus be neutralized to the level of DNA condensation. Electroanalytical measurement of DNA condensed with Co(phen)(3)(3+) in ethanol solution indicated that intercalating reaction remains existing. According to both the microscopic and spectroscopic results, it can be found that no secondary structure transition occurs upon DNA condensing. B-A conformation transition takes place at more than 60% ethanol solution.
Resumo:
The organic-inorganic hybrid, PSS-silica composite material was developed for the immobilization of tris(2,2'-bipyridyl)ruthenium(II) (Ru(bpy)(3)(2+)) on glassy carbon electrode via ion-exchange (PSS stands for poly(sodium 4-styrene-sulfonate)). The electrochemiluminescence (ECL) and electrochemistry of Ru(bpy)(3)(2-) immobilized in the composite thin films have been investigated with tripropylamine (TPA) as the coreactant. The immobilized Ru(bpy)(3)(2-) underwent a surface process. The modified electrode was used for the ECL detection of TPA and showed high sensitivity. Detection limit was 0,1 mumol L-1 for TPA (S/N = 3) with a linear range from 0.5 mumol L-1 to 5 mmol L-1 (R = 0.998), Moreover, the resulting modified electrode was stable over six months and the good stability may be due to the strong interaction between Ru(bpy)(3)(2-) and the high ion-exchange able PSS-silica composite films on GCE. Compared with other materials. the PSS-silica composite films containing incorporated Ru(bpy)(3)(2-) showed improved sensitivity and long-term stability, Thus, such composite thin film can be a promising material for the construction of ECL sensor.
Resumo:
A novel approach of generating cathodic electrochemiluminescence lof Ru(bpy)(3)(2+) at -0.4 V triggered by reactive oxygen species is reported for detecting alkylamines and some organic acids.
Resumo:
The first crystal structure of tris(methylcyclopentadienyl) tetrahydrofuranato (THF) lanthanide complexes, (CH3Cp)(3)Sm . THF, is determined. The complex crystallizes from mixed solvents of tetrahydrofuran and hexane as a monomer in the orthorhombic space group Pc2(1)n with the unit cell parameters a = 9.135(2) Angstrom, b = 13.263(2) Angstrom, c = 16.176(3) Angstrom, and Z = 4.
Resumo:
A surface-renewable tris (1,10-phenanthroline-5, 6-dione) iron (II) hexafluorophosphate (FePD) modified carbon ceramic electrode was constructed by dispersing FePD and graphite powder in methyltrimethoxysilane (MTMOS) based gels. The FePD-modified electrode presented pH dependent voltammetric behavior, and its peak currents were diffusion-controlled in 0.1 mol/L Na2SO4 + H2SO4 solution (pH = 0. 4). In the, presence of iodate, clear electrocatalytic reduction waves were observed and thus the chemically modified electrode was used as an amperometric sensor for iodate in common salt. The linear range, sensitivity, detection limit and response time of the iodate sensor were 5 x 10(-6)-1 x 10(-2) mol/L, 7.448 muA.L/mmol, 1.2 x 10(-6) mol/L and 5 s, respectively. A distinct advantage of this sensor is its good reproducibility of surface-renewal by simple mechanical polishing.
Resumo:
(C5H9C5H4)(3)NdBrLi(THF)(4)(1)(C5H9=cyclopentyl) was obtained from the reaction of NdCl3 with C5H9C5H4Na and LiBr (Nd:Na:Li=1:2:1 molar ratio) in THE X-ray crystallography showed that the ten-coordinated neodymium atom is bonded to three cyclopentylcyclopentadienyl(eta(5)) rings and a single bromine atom bridging a lithium which is bonded to three THF molecules. Complex 1 is triclinic, P1 space group with unit dimensions of a= 12.048(2), b= 13.498(3), c= 13.831(3)Angstrom, a = 104.16(3), beta = 104.07(3), gamma =95.96(3)degrees, V=2083.3(7)Angstrom(3), Z=2, D-c=1.35Mg/m(3) and F(000)=874. (C5H9C5H4)(3)SmTHF (2) was synthesized by reaction of anhydrous SmCl3 with C5H9C5H4Na at a molar ratio of 1:3. The structure was determined by X-ray crystallography. The ten-coordinated samarium atom is bonded to three cycloperrtylcyclopentadienyl rings and one oxygen of THF molecule to form a pseudo-tetrahedron. Complex 2 is orthorhombic, Fdd2 space group with unit cell dimensions of a =28.175(5)Angstrom, b =46.24(2) Angstrom, c =9.167(4) Angstrom(3), V=11943(8)Angstrom(3), Z= 16, D-c = 1.38Mg/m(3) and F(000)=5136.
Resumo:
A new detection scheme for the determination of adsorbable coreactants of Ru(bpy)(3)(2+) electrochemiluminescent reaction is presented. It is based on selective preconcentration of coreactant onto an electrode, followed by Ru(bpy)(3)(2+) electrochemiluminescent detection. The coreactant employed is chlorpromazine. It was sensitively detected after 5-min preconcentration onto a lauric acid-modified carbon paste electrode. The linear concentration range was found to occur from 1 x 10(-8) to 3 x 10(-6) mol L-1 with a detection limit of 3.1 x 10(-9) mol L-1. The total analysis time is less than 10 min. As a result of selective preconcentration and medium exchange, such remarkable selectivity is achieved that reproducible quantitation of chlorpromazine in urine is possible.
Resumo:
The ferric oxide nanoparticles-tris-(2,4-di-t-amylphenoxy)-(8-quinolinolyl) copper phthalocyanine (CuPcA(2)) composite ultrathin film was obtained by LB (Langmuir-Blodgett) technique. Structure of the composite LB film was characterized by X-ray photoelectron spectra, transmission electron microscopy, infrared spectra and visible spectra. Gas sensitivity measurements indicate that the composite LB film is sensitive to 100-200 ppm C2H5OH at room temperature. (C) 2000 Elsevier Science S.A. All rights reserved.
Resumo:
The solubility of [Tris-(acetylsalicylate)-terbium] [Tb(AS)(3)] is improved to a greater extent than [Tris-(salicylate)-terbium] [Tb(Sal)(3)] following introduction of a flexible acetyl group. Th3+ binds with acetylsalicylate in solution at low pH value and the resultant Tb(AS)(3) has good solubility in chloroform. A Green EL device with the structure ITO/PVK/PVB:PBD: Tb(AS)(3)/ PBD/Al has been fabricated based on soluble Tb(AS)(3), in which Tb(AS)(3) was first used as an emissive center doped with PVK and PBD. The hole-transporting layer and the emissive layer were formed by spin coating. The device exhibited a highly pure characteristic green light of Tb3+. (C) 2001 Elsevier Science B.V. All rights reserved.