979 resultados para Aortic disease


Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Anemia is a common comorbid condition in various inflammatory states and an established predictor of mortality in patients with chronic heart failure, ischemic heart disease, and end-stage renal disease. The present study of patients with abdominal aortic aneurysm (AAA) undergoing endovascular repair (EVAR) assessed the relationships between baseline hemoglobin concentration and AAA size, as well as anemia and long-term survival. METHODS: Between March 1994 and November 2006, 711 patients (65 women, mean age 75.8 +/- 7.8 years) underwent elective EVAR. Anemia was defined as a hemoglobin level <13 g/dL in men and <12 g/dL in women. Post-EVAR mean follow-up was 48.3 +/- 32.0 months. Association of hemoglobin level with AAA size was assessed with multiple linear regression. Mortality was determined with use of the internet-based Social Security Death Index and the electronic hospital record. Kaplan-Meier survival curves of anemic and nonanemic patient groups were compared by the log-rank method. Multivariable logistic regression models were used to determine the influence of anemia on vital status after EVAR. RESULTS: A total of 218/711 (30.7%) of AAA patients undergoing EVAR had anemia at baseline. After adjustment for various risk factors, hemoglobin level was inversely related to maximum AAA diameter (beta: - .144, 95%-CI: -1.482 - .322, P = .002). Post-EVAR survival was 65.5% at 5 years and 44.4% at 10 years. In long-term follow-up, survival was significantly lower in patients with anemia as compared to patients without anemia (P < .0001 by log-rank). Baseline hemoglobin levels were independently related to long-term mortality in multivariable Cox regression analysis adjusted for various risk factors (adjusted HR: 0.866, 95% CI: .783 to .958, P = .005). Within this model, statin use (adjusted HR: .517, 95% CI: .308 to .868, P = .013) was independently related to long-term survival, whereas baseline AAA diameter (adjusted HR: 1.022, 95% CI: 1.009 to 1.036, P = .001) was an independently associated with increased mortality. CONCLUSIONS: Baseline hemoglobin concentration is independently associated with AAA size and reduced long-term survival following EVAR. Thus, the presence or absence of anemia offers a potential refinement of existing risk stratification instruments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The prognostic relevance of the collateral circulation is still controversial. The goal of this study was to assess the impact on survival of quantitatively obtained, recruitable coronary collateral flow in patients with stable coronary artery disease during 10 years of follow-up. METHODS AND RESULTS: Eight-hundred forty-five individuals (age, 62+/-11 years), 106 patients without coronary artery disease and 739 patients with chronic stable coronary artery disease, underwent a total of 1053 quantitative, coronary pressure-derived collateral measurements between March 1996 and April 2006. All patients were prospectively included in a collateral flow index (CFI) database containing information on recruitable collateral flow parameters obtained during a 1-minute coronary balloon occlusion. CFI was calculated as follows: CFI = (P(occl) - CVP)/(P(ao) - CVP) where P(occl) is mean coronary occlusive pressure, P(ao) is mean aortic pressure, and CVP is central venous pressure. Patients were divided into groups with poorly developed (CFI < 0.25) or well-grown collateral vessels (CFI > or = 0.25). Follow-up information on the occurrence of all-cause mortality and major adverse cardiac events after study inclusion was collected. Cumulative 10-year survival rates in relation to all-cause deaths and cardiac deaths were 71% and 88%, respectively, in patients with low CFI and 89% and 97% in the group with high CFI (P=0.0395, P=0.0109). Through the use of Cox proportional hazards analysis, the following variables independently predicted elevated cardiac mortality: age, low CFI (as a continuous variable), and current smoking. CONCLUSIONS: A well-functioning coronary collateral circulation saves lives in patients with chronic stable coronary artery disease. Depending on the exact amount of collateral flow recruitable during a brief coronary occlusion, long-term cardiac mortality is reduced to one fourth compared with the situation without collateral supply.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Arterial hypertension in adults is often associated with an increased arterial stiffness, which correlates with the ambulatory arterial stiffness index (AASI) as derived from ambulatory blood pressure (BP) measurements. The purpose of this study was to demonstrate whether children with diagnosed hypertension have an increased AASI as in hypertensive adults. AASI was calculated from 185 ambulatory BP measurements of 114 hypertensive and 71 normotensive, healthy children. Hypertensive children had higher AASI values compared with their normotensive healthy counterparts (0.370 +/- 0.120 versus 0.204 +/- 0.199, p < 0.0001). Children with longer duration of hypertension or a history of primary or secondary aortic coarctation displayed even more elevated AASI values. A receiver operator curve derived cut-off of AASI set at 0.301 distinguished (p < 0.0001) hypertensive from normotensive children with an odds ratio of 8.2, a sensitivity of 81%, and a specificity of 65%. Moreover, AASI correlated with pulse and systolic BP. In conclusion, AASI is elevated in hypertensive children and correlates with the duration and the origin of hypertension in childhood.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: The success of open and endovascular repair of abdominal aortic aneurysms (AAA) is hampered by postoperative dilatation of the anatomical neck of the AAA, which is used for graft attachment. The purpose of this study was to determine whether the macroscopically non-diseased infrarenal aortic neck of AAA is histologically and biochemically altered at the time of operative repair. METHODS: We harvested full-thickness aortic wall samples as longitudinal stripes spanning from AAA neck to aneurysmal sac in 22 consecutive patients undergoing open surgical AAA repair. Control tissue was obtained from five organ donors and five deceased subjects undergoing autopsy without evidence of aneurysmal disease. We assessed aortic media thickness, number of intact elastic lamellar units, media destruction, and neovascularization grade and performed immunohistochemistry for matrix metalloproteinase (MMP)-9 and phosphorylated c-Jun N-terminal kinase (p-JNK). MMP-9 and p-JNK protein expressions were quantified using Western Blots. RESULTS: The median thickness of the aortic media was 1150 mum in control tissue (range, 1000-1300), 510 mum in aortic necks (250-900), and 200 mum in aortic sacs (50-500, P from nonparametric test for trend <.001). The number of intact elastic lamellar units was 33 in controls (range, 33-55), 12 in aortic necks (0-31) and three in aortic sacs (0-10, P < .001). The expression of MMP-9 and p-JNK as assessed by Western Blots (P = .007 and .061, respectively) and zymography (P for trend <.001) were up regulated in both the AAA neck and sac compared with controls. Except for p-JNK expression, differences between tissues were similar after the adjustment for age, gender, and type of sampling. CONCLUSION: The seemingly non-diseased infrarenal AAA neck in patients with AAA undergoing surgical repair shows histological signs of destruction and upregulation of potential drug targets.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: The implantation of a composite graft is the treatment of choice for patients with aortic root disease if the valve cannot be preserved and the patient is not a suitable candidate for a Ross procedure. Several years ago, the Shelhigh NR-2000C (Shelhigh, Inc, Millburn, NJ) was introduced in Europe. Being a totally biologic conduit and considering the lack of homografts, the graft seemed an ideal conduit for patients with destructive endocarditis, as well as for older patients who were not suitable candidates for oral anticoagulation. METHODS: From 2001 until 2006, the Shelhigh NR-2000C stentless valved conduit was implanted in 115 patients for various aortic root pathologies. The conduit consists of a bovine pericardial straight graft with an incorporated porcine stentless valve. Aortic root repair was performed during standard cardiopulmonary bypass and mild hypothermia in the majority of patients. Deep hypothermic circulatory arrest combined with selective antegrade cerebral perfusion was used when the repair extended into the arch. RESULTS: Seven patients with uncomplicated early outcome presented with unexpected sudden disastrous findings at the level of the aortic root, although 1-year follow-up computed tomographic scans were normal. Four of these patients underwent emergency operations because of desintegration of the graft, along with rupture of the aortic root. Retrospectively, the main findings were persistent fever or subfebrility over months and a halo-like enhancement on computed tomographic scans. Extensive microbiologic examinations were performed without finding a causative organism. CONCLUSION: The use of the Shelhigh aortic stentless conduit can no longer be advocated, and meticulous follow-up of patients in whom this device has been implanted has to be recommended.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND AND AIM OF THE STUDY: Preservation of the aortic valve during the repair of acute type A aortic dissection (AADA) is a viable option to prevent lifelong oral anticoagulation. The study aim was to assess aortic valve function following resuspension and supracoronary ascending aortic grafting. METHODS: Among a collective of 210 consecutive patients undergoing surgery for AADA, 140 (66.7%) with resuspension of the aortic valve and supracoronary ascending graft were analyzed. Of these patients, 83 (59.3%) had a complete follow up (mean 61.2 +/- 40.8 months), with 65 of the subgroup (78.3%) being followed by computed tomography scanning and echocardiography. RESULTS: Reoperation due to severe aortic valve regurgitation was required in seven patients (10.8%). The perioperative characteristics were similar in these patients; notably, no significant difference was evident with regards to the aortic annulus diameter and the severity of regurgitation at the time of surgery. The left ventricular mass index was significantly higher in patients requiring reoperation due to aortic valve regurgitation (219.3 +/- 146.6 versus 123.9 +/- 146.6 g/m2; p <0.05). None of the patients died as a result of reoperation. CONCLUSION: The long-term functional results following resuspension of the aortic valve in AADA were very good. A close echocardiographic follow up was necessary, as reoperation of the aortic valve was required in more than 10% of the collective, with an average follow up of five years. Reoperation was mainly related to secondary dilatation of the aortic root.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVE: The standard surgical repair of disease of the aortic valve and the ascending aorta has been combined replacement, which includes the disadvantage of inserting a mechanical valve. We have investigated an individualized approach which preserves the native valve. PATIENTS AND METHODS: Between October 1995 and October 1997, a consecutive total of 101 patients (72 men, 29 women, aged 21-83 years) underwent operations for disease of the ascending aorta: aortic dissection type A in 34 patients, aneurysmal dilatation in 67. Dilatation of the aortic arch was associated with aortic regurgitation in 58 patients. There were 11 patients with aortic valve stenosis or previously implanted aortic valve prosthesis among a total of 46 whose aortic valve was replaced (group II). Supracommissural aortic replacement with a Dacron tube was performed in 16 patients (group I) with normal valve cusps and an aortic root diameter < 3.5 cm. In 28 patients with an aortic root diameter of 3.5-5.0 cm the aortic root was remodelled (group III). Resuspension of the native aortic valve was undertaken in 11 patients with aortic root dilatation of > 5.0 cm (group IV). RESULTS: Operative intervention was electively performed in 72 patients, without any death. Of 29 patients operated as an emergency for acute type A dissection four died (14%). In 55 of the 58 patients with aortic regurgitation in proved possible to preserve native aortic valve (95%). In the early postoperative phase and after an average follow-up time of 11.8 months, transthoracic echocardiography demonstrated good aortic valve function, except in one patient each of groups III and IV who developed aortic regurgitation grades I or II. CONCLUSION: The described individualized approach makes it possible to preserve the native aortic valve in most patients with aortic regurgitation, at a low risk. Follow-up observations so far indicate good results of the reconstruction.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Complete arterial CABG is a surgical option to improve long-term results in the treatment of coronary artery disease (CAD). Harvesting of multiple arterial grafts is commonly associated with prolonged operating times and increased trauma. By use of new operative techniques (skeletonized grafts and the T-graft approach), CABG in multivessel CAD is now possible with only 2 grafts. We present our experience in the use of these techniques on a routine basis. METHODS AND RESULTS: Between March 1996 and September 1999, 490 patients (aged 61+/-9 years, 20% female) underwent complete arterial CABG. Left ventricular ejection fraction ranged from 15% to 85% (mean 59+/-15%). Triple-vessel disease was present in 88% of the patients. The incidence of diabetes mellitus was 32% (14% insulin dependent). Either both internal thoracic arteries (ITAs) (23%) or the left ITA and radial artery (77%) were used as conduits. In 85% of the patients, a T graft was created. Mean operating time was 198+/-46 minutes; bypass time, 82+/-25 minutes; and ischemic time, 58+/-22 minutes. Two to 7 (mean 4.1+/-0.9) anastomoses were performed per patient. Perioperative intra-aortic balloon pump was necessary in 12 patients (2.4%). The rate of perioperative myocardial infarction was 1.2%. Sternal complications occurred in 1. 0%, and in-hospital mortality was 2.2%. Postoperative coronary angiography in 172 patients (35%) documented excellent patency rates (left ITA 98.3%, right ITA 96.5%, and radial artery 96.6%). CONCLUSIONS: Complete arterial revascularization in multivessel CAD is possible with the use of only 2 grafts with good perioperative results. This approach allows for complete arterial CABG on a routine basis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The association between aortic valve disease and coronary atherosclerosis is common. In the recent era of percutaneous aortic valve replacement (PAVR), there is little experience with coronary artery intervention after valve implantation. CASE REPORT: To our knowledge, this is the first case of successful percutaneous coronary intervention after implantation of a CoreValve percutaneous aortic valve. We report a case of a 79-year-old female patient who underwent successful coronary artery intervention few months after a CoreValve's percutaneous implantation for severe aortic valve stenosis. Verifying the position of the used wires (crossing from inside the self expanding frame) is of utmost importance before proceeding to coronary intervention. In this case, crossing the aortic valve, coronary angiography, and multivessel stenting were successfully performed. CONCLUSION: Percutaneous coronary intervention in patients with previous CoreValve is feasible and safe.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Transcatheter aortic valve implantation (TAVI) for high-risk and inoperable patients with severe aortic stenosis is an emerging procedure in cardiovascular medicine. Little is known of the impact of TAVI on renal function. METHODS: We analysed retrospectively renal baseline characteristics and outcome in 58 patients including 2 patients on chronic haemodialysis undergoing TAVI at our institution. Acute kidney injury (AKI) was defined according to the RIFLE classification. RESULTS: Fifty-eight patients with severe symptomatic aortic stenosis not considered suitable for conventional surgical valve replacement with a mean age of 83 +/- 5 years underwent TAVI. Two patients died during transfemoral valve implantation and two patients in the first month after TAVI resulting in a 30-day mortality of 6.9%. Vascular access was transfemoral in 46 patients and transapical in 12. Estimated glomerular filtration rate (eGFR) increased in 30 patients (56%). Fifteen patients (28%) developed AKI, of which four patients had to be dialyzed temporarily and one remained on chronic renal replacement therapy. Risk factors for AKI comprised, among others, transapical access, number of blood transfusions, postinterventional thrombocytopaenia and severe inflammatory response syndrome (SIRS). CONCLUSIONS: TAVI is feasible in patients with a high burden of comorbidities and in patients with pre-existing end-stage renal disease who would be otherwise not considered as candidates for conventional aortic valve replacement. Although GFR improved in more than half of the patients, this benefit was associated with a risk of postinterventional AKI. Future investigations should define preventive measures of peri-procedural kidney injury.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The efficacy of granulocyte colony-stimulating factor (G-CSF) for coronary collateral growth promotion and thus impending myocardial salvage has not been studied so far, to our best knowledge. METHODS AND RESULTS: In 52 patients with chronic stable coronary artery disease, age 62+/-11 years, the effect on a marker of myocardial infarct size (ECG ST segment elevation) and on quantitative collateral function during a 1-minute coronary balloon occlusion was tested in a randomized, placebo-controlled, double-blind fashion. The study protocol before coronary intervention consisted of occlusive surface and intracoronary lead ECG recording as well as collateral flow index (CFI, no unit) measurement in a stenotic and a > or =1 normal coronary artery before and after a 2-week period with subcutaneous G-CSF (10 microg/kg; n=26) or placebo (n=26). The CFI was determined by simultaneous measurement of mean aortic, distal coronary occlusive, and central venous pressure. The ECG ST segment elevation >0.1 mV disappeared significantly more often in response to G-CSF (11/53 vessels; 21%) than to placebo (0/55 vessels; P=0.0005), and simultaneously, CFI changed from 0.121+/-0.087 at baseline to 0.166+/-0.086 at follow-up in the G-CSF group, and from 0.152+/-0.082 to 0.131+/-0.071 in the placebo group (P<0.0001 for interaction of treatment and time). The absolute change in CFI from baseline to follow-up amounted to +0.049+/-0.062 in the G-CSF group and to -0.010+/-0.060 in the placebo group (P<0.0001). CONCLUSIONS: Subcutaneous G-CSF is efficacious during a short-term protocol in improving signs of myocardial salvage by coronary collateral growth promotion.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND AND AIM OF THE STUDY: Combined replacement of the aortic valve and ascending aorta using a composite graft represents the standard treatment for dilated aortic root with concomitant structural damage of the aortic valve, especially when the aortic valve cannot be preserved. Unfortunately, hemodynamic changes associated with prosthetic replacement of the aortic root have not been fully elucidated. The study aim was to compare hemodynamics within the replaced aortic root using either a prosthetic vascular graft with bulges mimicking the sinuses of Valsalva and including a stented pericardial valve, or a straight xenopericardial conduit and a stentless porcine valve. METHODS: Between July 2004 and March 2006, a total of 35 patients (mean age 65.2 years: range: 32-80 years) was enrolled into the present study. Aortic root replacement was performed in nine patients with a Valsalva graft (Gelweave Valsalva; Vascutek, Renfrewshire, UK) including a stented pericardial valve, and in 19 patients with a xenopericardial conduit containing a stentless porcine valve. All patients underwent postoperative magnetic resonance imaging (MRI). A control group of seven patients allowed for comparison with native aortic root hemodynamics. RESULTS: Maximum flow-velocity above the aortic valve as one marker of compliance of the aortic root was slightly higher in patients with a Valsalva graft compared to native aortic roots (1.9 m/s versus 1.3 m/s, p = 0.001), but was significantly lower than in patients with the xenopericardial graft without neo-sinuses (1.3 m/s versus 2.4 m/s, p < 0.001). CONCLUSION: The pre-shaped bulges in the prosthetic Valsalva graft effectively mimic the native sinuses of Valsalva, improve compliance of the aortic root, and result in a more physiologic flow pattern, as demonstrated by postoperative MRI.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abdominal aortic aneurysms (AAA) confer a substantial healthcare burden in the Western world. Surgical or endovascular therapy is indicated in patients with a maximum diameter exceeding 5.5 cm. Patients with smaller AAA must undergo a specific ultrasound surveillance program aimed at avoiding exposure to an increased risk of rupture once their AAA exceeds the threshold for active treatment. Based on improved understanding of the pathophysiology of AAA, recent years provided initial insight into potential medical treatment options. The presence of AAA is currently regarded a coronary artery disease risk equivalent. ACE inhibitors, statins and JNK-inhibitors were shown to have the potential to slow down progression. Since cigarette smoking is the main risk factor for both the development and progression of AAA, smoking cessation remains a key goal. Further prospective studies will assess the clinical efficacy of various promising drug treatment approaches aimed at slowing disease progression of small AAA and after endovascular therapy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A 12 yr old Dalmatian was referred for evaluation of acute lethargy, fever, neurologic signs, and a recently ausculted heart murmur. Echocardiography in combination with blood cultures resulted in a diagnosis of nonhospital-acquired Serratia marcescens bacteremia and aortic valve endocarditis. Despite early diagnosis and aggressive therapy, the dog failed to respond to antimicrobials and died within 6 hr after admission. Necropsy findings included aortic valve endocarditis, septicemia, and diffuse thromboembolic disease. There was no history of pre-existing underlying disease or immunosuppressive therapy, and the dog had not been hospitalized before referral.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES To review the incidence, clinical presentation, definite management and 1-year outcome in patients with aorto-oesophageal fistulation (AOF) following thoracic endovascular aortic repair (TEVAR). METHODS International multicentre registry (European Registry of Endovascular Aortic Repair Complications) between 2001 and 2011 with a total caseload of 2387 TEVAR procedures (17 centres). RESULTS Thirty-six patients with a median age of 69 years (IQR 56-75), 25% females and 9 patients (19%) following previous aortic surgery were identified. The incidence of AOF in the entire cohort after TEVAR in the study period was 1.5%. The primary underlying aortic pathology for TEVAR was atherosclerotic aneurysm formation in 53% of patients and the median time to development of AOF was 90 days (IQR 30-150). Leading clinical symptoms were fever of unknown origin in 29 (81%), haematemesis in 19 (53%) and shock in 8 (22%) patients. Diagnosis could be confirmed via computed tomography in 92% of the cases with the leading sign of a new mediastinal mass in 28 (78%) patients. A conservative approach resulted in a 100% 1-year mortality, and 1-year survival for an oesophageal stenting-only approach was 17%. Survival after isolated oesophagectomy was 43%. The highest 1-year survival rate (46%) could be achieved via an aggressive treatment including radical oesophagectomy and aortic replacement [relative risk increase 1.73 95% confidence interval (CI) 1.03-2.92]. The survival advantage of this aggressive treatment modality could be confirmed in bootstrap analysis (95% CI 1.11-3.33). CONCLUSIONS The development of AOF is a rare but lethal complication after TEVAR, being associated with the need for emergency TEVAR as well as mediastinal haematoma formation. The only durable and successful approach to cure the disease is radical oesophagectomy and extensive aortic reconstruction. These findings may serve as a decision-making tool for physicians treating these complex patients.