888 resultados para Anterior spinal fusion
Resumo:
OBJECTIVE To evaluate use of a surgical technique commonly used in humans for treatment of cervical spondylotic myelopathy (CSM) in dogs. DESIGN Prospective case series. ANIMALS Dogs with CSM (n=10). METHODS Dogs weighing >30 kg that had CSM at 1 vertebral articulation were eligible for inclusion. Dogs had vertebral column distraction/fusion performed using a cortical ring allograft, cancellous autograft, and a spinal locking plate. Dogs were evaluated temporally by repeat neurological examinations and by client perception of postsurgical outcome, determined by telephone interview. RESULTS Nine dogs survived the immediate postoperative period. Seven of 8 dogs had moderate to complete improvement without recurrence (mean follow-up, 2.48 years). The most common postsurgical complications were screw loosening (n=4) and plate shifting (2), neither of which required surgical revision. One dog had pseudoarthrosis that may have negatively impacted outcome. CONCLUSION Treatment of single level CSM in dogs with ring allograft and a spinal locking plate system may lead to successful outcomes. The major problems encountered with included cost of the implants and adjusting the system designed for humans to fit the vertebral column of a dog. CLINICAL RELEVANCE For dogs with CSM at a single level, the use of a spinal locking plate in combination with a cortical ring allograft can be an effective surgical treatment. Costs of the implants as well as anatomic differences in dogs make this type of surgery less appealing.
Resumo:
PURPOSE To compare patient outcomes and complication rates after different decompression techniques or instrumented fusion (IF) in lumbar spinal stenosis (LSS). METHODS The multicentre study was based on Spine Tango data. Inclusion criteria were LSS with a posterior decompression and pre- and postoperative COMI assessment between 3 and 24 months. 1,176 cases were assigned to four groups: (1) laminotomy (n = 642), (2) hemilaminectomy (n = 196), (3) laminectomy (n = 230) and (4) laminectomy combined with an IF (n = 108). Clinical outcomes were achievement of minimum relevant change in COMI back and leg pain and COMI score (2.2 points), surgical and general complications, measures taken due to complications, and reintervention on the index level based on patient information. The inverse propensity score weighting method was used for adjustment. RESULTS Laminotomy, hemilaminectomy and laminectomy were significantly less beneficial than laminectomy in combination with IF regarding leg pain (ORs with 95% CI 0.52, 0.34-0.81; 0.25, 0.15-0.41; 0.44, 0.27-0.72, respectively) and COMI score improvement (ORs with 95% CI 0.51, 0.33-0.81; 0.30, 0.18-0.51; 0.48, 0.29-0.79, respectively). However, the sole decompressions caused significantly fewer surgical (ORs with 95% CI 0.42, 0.26-0.69; 0.33, 0.17-0.63; 0.39, 0.21-0.71, respectively) and general complications (ORs with 95% CI 0.11, 0.04-0.29; 0.03, 0.003-0.41; 0.25, 0.09-0.71, respectively) than laminectomy in combination with IF. Accordingly, the likelihood of required measures was also significantly lower after laminotomy (OR 0.28, 95% CI 0.17-0.46), hemilaminectomy (OR 0.28, 95% CI 0.15-0.53) and after laminectomy (OR 0.39, 95% CI 0.22-0.68) in comparison with laminectomy with IF. The likelihood of a reintervention was not significantly different between the treatment groups. DISCUSSION As already demonstrated in the literature, decompression in patients with LSS is a very effective treatment. Despite better patient outcomes after laminectomy in combination with IF, caution is advised due to higher rates of surgical and general complications and consequent required measures. Based on the current study, laminotomy or laminectomy, rather than hemilaminectomy, is recommendable for minimum relevant pain relief.
Resumo:
BACKGROUND CONTEXT Several randomized controlled trials (RCTs) have compared patient outcomes of anterior (cervical) interbody fusion (AIF) with those of total disc arthroplasty (TDA). Because RCTs have known limitations with regard to their external validity, the comparative effectiveness of the two therapies in daily practice remains unknown. PURPOSE This study aimed to compare patient-reported outcomes after TDA versus AIF based on data from an international spine registry. STUDY DESIGN AND SETTING A retrospective analysis of registry data was carried out. PATIENT SAMPLE Inclusion criteria were degenerative disc or disc herniation of the cervical spine treated by single-level TDA or AIF, no previous surgery, and a Core Outcome Measures Index (COMI) completed at baseline and at least 3 months' follow-up. Overall, 987 patients were identified. OUTCOME MEASURES Neck and arm pain relief and COMI score improvement were the outcome measures. METHODS Three separate analyses were performed to compare TDA and AIF surgical outcomes: (1) mimicking an RCT setting, with admission criteria typical of those in published RCTs, a 1:1 matched analysis was carried out in 739 patients; (2) an analysis was performed on 248 patients outside the classic RCT spectrum, that is, with one or more typical RCT exclusion criteria; (3) a subgroup analysis of all patients with additional follow-up longer than 2 years (n=149). RESULTS Matching resulted in 190 pairs with an average follow-up of 17 months that had no residual significant differences for any patient characteristics. Small but statistically significant differences in outcome were observed in favor of TDA, which are potentially clinically relevant. Subgroup analyses of atypical patients and of patients with longer-term follow-up showed no significant differences in outcome between the treatments. CONCLUSIONS The results of this observational study were in accordance with those of the published RCTs, suggesting substantial pain reduction both after AIF and TDA, with slightly greater benefit after arthroplasty. The analysis of atypical patients suggested that, in patients outside the spectrum of clinical trials, both surgical interventions appeared to work to a similar extent to that shown for the cohort in the matched study. Also, in the longer-term perspective, both therapies resulted in similar benefits to the patients.
Resumo:
Mode of access: Internet.
Resumo:
Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.
Resumo:
Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.
Resumo:
The primary aims of scoliosis surgery are to halt the progression of the deformity, and to reduce its severity (cosmesis). Currently, deformity correction is measured in terms of posterior parameters (Cobb angles and rib hump), even though the cosmetic concern for most patients is anterior chest wall deformity. In this study, we propose a new measure for assessing anterior chest wall deformity and examine the correlation between rib hump and the new measure. 22 sets of CT scans were retrieved from the QUT/Mater Paediatric Spinal Research Database. The Image J software (NIH) was used to manipulate formatted CT scans into 3-dimensional anterior chest wall reconstructions. A ‘chest wall angle’ was then measured in relation to the first sacral vertebral body. The chest wall angle was found to be a reliable tool in the analysis of chest wall deformity. No correlation was found between the new measure and rib hump angle. Since rib hump has been shown to correlate with vertebral rotation on CT, this suggests that there maybe no correlation between anterior and posterior deformity measures. While most surgical procedures will adequately address the coronal imbalance & posterior rib hump elements of scoliosis, they do not reliably alter the anterior chest wall shape. This implies that anterior chest wall deformity is to a large degree an intrinsic deformity, not directly related to vertebral rotation.
Resumo:
Fusionless scoliosis surgery is an emerging treatment for idiopathic scoliosis as it offers theoretical advantages over current forms of treatment. Anterior vertebral stapling using a nitinol staple is one such treatment. Despite increasing interest in this technique, little is known about the effects on the spine following insertion, or the mechanism of action of the staple. The aims of this study were threefold; (1) to measure changes in the bending stiffness of a single motion segment following staple insertion, (2) to describe the forces that occur within the staple during spinal movement, and (3) to describe the anatomical changes that occur following staple insertion. Results suggest that staple insertion consistently decreased stiffness in all directions of motion. An explanation for the finding may be found in the outcomes of the strain gauge testing and micro-CT scan. The strain gauge testing showed that once inserted, the staple tips applied a baseline compressive force to the surrounding trabecular bone and vertebral end-plate. This finding would be consistent with the current belief that the clinical effect of the staples is via unilateral compression of the physis. Interestingly however, as each specimen progressed through the five cycles of each test, the baseline load on the staple tips gradually decreased, implying that the force at the staple tip-bone interface was decreasing. We believe that this was likely occurring as a result of structural damage to the trabecular bone and vertebral end-plate by the staple effectively causing ‘loosening’ of the staple. This hypothesis is further supported by the findings of the micro-CT scan. The pictures depict significant trabecular bone and physeal injury around the staple blades. These results suggest that the current hypothesis that stapling modulates growth through physeal compression may be incorrect, but rather the effect occurs through mechanical disruption of the vertebral growth plate.
Resumo:
Top screw pullout occurs when the screw is under too much axial force to remain secure in the vertebral body. In vitro biomechanical pullout tests are commonly done to find the maximum fixation strength of anterior vertebral body screws. Typically, pullout tests are done instantaneously where the screw is inserted and then pulled out immediately after insertion. However, bone is a viscoelastic material so it shows a time dependent stress and strain response. Because of this property, it was hypothesised that creep occurs in the vertebral trabecular bone due to the stress caused by the screw. The objective of this study was therefore to determine whether the axial pullout strength of anterior vertebral body screws used for scoliosis correction surgery changes with time after insertion. This study found that there is a possible relationship between pullout strength and time; however more testing is required as the sample numbers were quite small. The design of the screw is made with the knowledge of the strength it must obtain. This is important to prevent such occurrences as top screw pullout. If the pullout strength is indeed decreased due to creep, the design of the screw may need to be changed to withstand greater forces.
Resumo:
Adolescent idiopathic scoliosis (AIS) is the most common form of spinal deformity in paediatrics, prevalent in approximately 2-4% of the general population. While it is a complex three-dimensional deformity, it is clinically characterised by an abnormal lateral curvature of the spine. The treatment for severe deformity is surgical correction with the use of structural implants. Anterior single rod correction employs a solid rod connected to the anterior spine via vertebral body screws. Correction is achieved by applying compression between adjacent vertebral body screws, before locking each screw onto the rod. Biomechanical complication rates have been reported as high as 20.8%, and include rod breakage, screw pull-out and loss of correction. Currently, the corrective forces applied to the spine are unknown. These forces are important variables to consider in understanding the biomechanics of scoliosis correction. The purpose of this study was to measure these forces intra-operatively during anterior single rod AIS correction.
Resumo:
Scoliosis is a three-dimensional spinal deformity which requires surgical correction in progressive cases. In order to optimize correction and avoid complications following scoliosis surgery, patient-specific finite element models (FEM) are being developed and validated by our group. In this paper, the modeling methodology is described and two clinically relevant load cases are simulated for a single patient. Firstly, a pre-operative patient flexibility assessment, the fulcrum bending radiograph, is simulated to assess the model's ability to represent spine flexibility. Secondly, intra-operative forces during single rod anterior correction are simulated. Clinically, the patient had an initial Cobb angle of 44 degrees, which reduced to 26 degrees during fulcrum bending. Surgically, the coronal deformity corrected to 14 degrees. The simulated initial Cobb angle was 40 degrees, which reduced to 23 degrees following the fulcrum bending load case. The simulated surgical procedure corrected the coronal deformity to 14 degrees. The computed results for the patient-specific FEM are within the accepted clinical Cobb measuring error of 5 degrees, suggested that this modeling methodology is capable of capturing the biomechanical behaviour of a scoliotic human spine during anterior corrective surgery.
Resumo:
Adolescent idiopathic scoliosis (AIS) is a three-dimensional spinal deformity involving the side-to-side curvature of the spine in the coronal plane and axial rotation of the vertebrae in the transverse plane. For patients with a severe or rapidly progressing deformity, corrective instrumented fusion surgery is performed. The wide choice of implants and large variability between patients make it difficult for surgeons to choose optimal treatment strategies. This paper describes the patient specific finite element modelling techniques employed and the results of preliminary analyses predicting the surgical outcomes for a series of AIS patients. This report highlights the importance of not only patient-specific anatomy and material parameters, but also patient-specific data for the clinical and physiological loading conditions experienced by the patient who has corrective scoliosis surgery.
Resumo:
Background A large animal model is required for assessment of minimally invasive, tissue engineering based approaches to thoracic spine fusion, with relevance to deformity correction surgery for human adolescent idiopathic scoliosis. Here we develop a novel open mini–thoracotomy approach in an ovine model of thoracic interbody fusion which allows assessment of various fusion constructs, with a focus on novel, tissue engineering based interventions. Methods The open mini-thoracotomy surgical approach was developed through a series of mock surgeries, and then applied in a live sheep study. Customized scaffolds were manufactured to conform with intervertebral disc space clearances required of the study. Twelve male Merino sheep aged 4 to 6 years and weighing 35 – 45 kg underwent the abovementioned procedure and were divided into two groups of six sheep at survival timelines of 6 and 12 months. Each sheep underwent a 3-level discectomy (T6/7, T8/9 and T10/11) with randomly allocated implantation of a different graft substitute at each of the three levels; (i) polycaprolactone (PCL) based scaffold plus 0.54μg rhBMP-2, (ii) PCL-based scaffold alone or (iii) autograft. The sheep were closely monitored post- operatively for signs of pain (i.e. gait abnormalities/ teeth gnawing/ social isolation). Fusion assessments were conducted post-sacrifice using Computed Tomography and hard-tissue histology. All scientific work was undertaken in accordance with the study protocol has been approved by the Institute's committee on animal research. Results. All twelve sheep were successfully operated on and reached the allotted survival timelines, thereby demonstrating the feasibility of the surgical procedure and post-operative care. There were no significant complications and during the post-operative period the animals did not exhibit marked signs of distress according to the described assessment criteria. Computed Tomographic scanning demonstrated higher fusion grades in the rhBMP-2 plus PCL-based scaffold group in comparison to either PCL-based scaffold alone or autograft. These results were supported by histological evaluation of the respective groups. Conclusion. This novel open mini-thoracotomy surgical approach to the ovine thoracic spine represents a safe surgical method which can reproducibly form the platform for research into various spine tissue engineered constructs (TEC) and their fusion promoting properties.