316 resultados para Ancoragem ortodôntica


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Contemporary orthodontics has sought, beyond the esthetic, occlusal and functional goals, treatments even faster and with less visits to the orthodontist — especially in patients that require dental extractions in which the generated space becomes a nuisance. The segmented arch technic (SAT), by the use of a "T" loop spring, has provided such results within these requirements. Therefore, this study aimed to appraise and demonstrate the confection, activation and biomechanical control of "T" loop spring, in the group with high anchorage necessity (group A), for retraction of anterior teeth; as well as to present a case report, with high anterior retraction necessity, treated with "T" loop spring.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The relationship of Orthodontics and Endodontics is being clarified with the development of evidence-based dentistry. However, few studies have reported the repair of periapical lesions with orthodontic treatment. Therefore, the aim of this study was to evaluate the available evidence on periapical repair of endodontically treated teeth during orthodontic movement. The strategy used was the electronic search with keywords and criteria including studies published up to July 2011. It was also carried out qualitative assessment of the articles methodology. Although a significant number of studies have reported this topic, only two filled the criteria for inclusion in this systematic review. The results obtained in the literature suggest that orthodontic treatment should be interrupted to perform endodontic treatment. During this therapy, the use of root canal dressing based on calcium hydroxide for at least 14 days, and sealer with adequate biological property are indicated. After this phase, orthodontic movement of the endodontically treated teeth can be resumed without waiting period.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Disposição construtiva aplicada em contenção ortodôntica. Patente de modelo de utilidade para uma disposição construtiva aplicada em contenção ortodôntica, compreendida por ser do tipo 3x3, com encaixe do tipo "macho-fêmea", sendo que na base da "fêmea" (1) são procedidas retenções (2) mecânicas para fixação por meio de colagem na face lingual dos caninos (3) inferiores, com resina composta, de modo que no interior da "fêmea" (1) é provido um orifício (4) para o encaixe do "macho" (5) e, no centro da cavidade é provido um anel (6) elástico que se encaixa precisamente numa canaleta feita no pino (7) de encaixe do "macho" (5), sendo que, na extremidade dos "machos" (5) podem existir prolongamentos (8) metálicos para retenção de acrílico (9) ou então meios de encaixe para soldagem de um fio metálico (10) espesso, que contorna a face lingual dos dentes (11); inferiores anteriores, de modo que, quando se optar pela retenção em acrilico (9), um fio metálico (10) mais delgado é soldado no terminal de encaixe do "macho" (5) e logo após, o fio (10) e o terminal são recobertos por acrilico (9), sendo que os "machos" (5) poderão ter angulações nos braços (12) de encaixes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During clinical routine, the orthodontist uses several materials, which include metallic alloys in the form of metallic wires. However, it is necessary that the professional has some knowledge of the properties of those wires. Different types of wires are commercially available: stainless steel wires, chrome-cobalt wires, nickel-titanium wires and beta-titanium wires. Among the nickel-titanium wires, there are three subdivisions: a conventional alloy and two superelastic alloys. The superelasticity, associated to the effect of form memory, is a property used in orthodontics to initiate the dental movement in the first phase of the orthodontic treatment. This property is considered to be biologically compatible with the effective dental movement. These wires are available at the market in different transformation temperatures, and they offer the best adaptation in the groove of the bracket, simplicity and a faster treatment. However, they present little formability, and they don’t accept solder. They are also more onerous than other wires. Moreover, the low rigidity of these wires doesn’t allow them to be used for the retraction of the anterior teeth or closing of spaces. Therefore, the coherent use of superelastic orthodontic wires is recommended, accompanied by a detailed diagnosis and planning, so the result will be an efficient orthodontic correction, accomplished in a shorter period of time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Ortodontia apresenta como um de seus pilares de sustentação as reações biológicas provenientes da indução mecânica. Desde seu início, vários estudos foram realizados para esclarecer os eventos biológicos decorrentes da movimentação dentária sob indução mecânica. Entretanto, mesmo sabendo-se que entre os procedimentos mecânicos e os fenômenos biológicos que acontecem no cotidiano ortodôntico não deve ocorrer disparidade, frequentemente observa-se uma preponderância para a busca do tipo de aparelhagem e o emprego de forças controladas, principalmente pelos fios. Esses aspectos deixam transparecer, principalmente para o profissional menos experiente, que somente o controle mecânico rege a movimentação dentária. Um exemplo que enfatiza exclusivamente o procedimento mecânico nos cursos de Ortodontia é o typodont. Convém salientar que essa metodologia de ensino é válida para simular a movimentação dentária no aspecto técnico-mecânico, porém, o conhecimento biológico da movimentação deve ter o mesmo nível de importância e não pode haver dicotomia; caso contrário, o resultado da movimentação ortodôntica pode causar prejuízos nas estruturas radiculares, óssea e periodontais, bem como comprometer as diversas estruturas em longo prazo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O traumatismo dentoalveolar é uma ocorrência cada vez mais comum na população em geral e está relacionado, na maioria das vezes à violência no trânsito, violência urbana e à prática esportiva. Esse aspecto, por conseguinte, tem aumentado sobremaneira o número de pacientes que procuram o tratamento ortodôntico e que relatam ter passado por algum episódio de trauma em seus dentes. Dentro desse contexto, muitas questões surgem com relação ao manejo de dentes com histórico de traumatismo dentoalveolar. Do ponto de vista histológico, quais as diferenças em movimentar-se um dente com histórico de trauma? O fato de um dente ter sido traumatizado pode influenciar no planejamento e no tratamento ortodôntico? E o protocolo das ativações do aparelho deveria ser alterado? O objetivo desse trabalho é apresentar uma breve revisão de literatura, bem como dois casos clínicos de pacientes que sofreram trauma dentário prévio à movimentação ortodôntica, no sentido de gerar subsídios técnicos e científicos para o especialista em Ortodontia, de modo que busque conhecer as implicações e limitações em movimentar dentes traumatizados.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent orthodontic bonding materials have aimed to reduce the working time of the clinician, by simplifying the acid etching procedure by applying self-etching primer adhesive systems. However, the adhesion quality of these materials still demands investigation. Thus, the present study aimed to evaluate the bond strengths of three different adhesive systems. A hundred and eighty bovine lower incisors were cut and embebbed in acrylic resin matrices, in which orthodontic brackets were bonded with Transbond XT (2n = 60), Transbond XT Self Etching Primer (2n = 60) e Tyrian (2n = 60). For each composite, bond strength tests were executed immediately (n = 30) and 24 hours (n = 30) after the bonding, in the assay machine Versat 2000 (Pantec), by applying 500 Kgf of load at 1mm/min of velocity. Transbond XT, Transbond XT Self Etching Primer and Tyrian presented, respectively, average values of bond strength of 7.43, 7.09 and 3.41 MPa at the time immediately, and 7.42, 8.81 and 5.35 MPa at 24 hours after the bonding, where differences were statistically significant at 5% between Tyrian and Transbond groups at both observation times. It was concluded that Tyrian was the material that presented significant lower bond strength with regard to Transbond groups that were similar.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objetivo: a proposta desse estudo foi avaliar, por meio de microscopia eletrônica de varredura (MEV), a interface adesiva após a descolagem de acessórios ortodônticos, fixados em dentes bovinos com emprego de adesivo hidrofílico e hidrofóbico, em condições distintas de umidade do substrato dentário. Métodos: foram utilizados 20 incisivos inferiores, divididos em quatro grupos (n = 5): Grupo I , empregou-se o sistema de colagem contendo o primer hidrofílico Transbond MIP e a pasta adesiva Transbond XT, aplicados em substrato úmido; Grupo II, empregou-se o sistema de colagem primer hidrofóbico Transbond XT e pasta adesiva em substrato úmido; Grupos III e IV, os braquetes foram colados com os mesmos sistemas de união dos Grupos I e II, porém com esmalte dentário seco. Removidos os acessórios, avaliou-se em MEV, em diferentes magnificações, a interface adesiva e a interação dos sistemas adesivos com o esmalte dentário. As imagens foram avaliadas qualitativamente, observando-se o embricamento mecânico para o adesivo hidrófilo em quaisquer condições de substrato. Resultados: a falta de umidade no esmalte condicionado permitiu uma melhor interação entre os materiais de ligação e a estrutura adamantina. O adesivo hidrofóbico apresentou o pior resultado de interação micromecânica quando aplicado a uma estrutura dentária úmida; já o sistema hidrofílico mostrou-se versátil, obtendo resultados aceitáveis em condições de umidade e excelente interação na ausência de contaminação. Conclusão: os autores afirmam que a melhor condição do esmalte dentário para a aplicação de primers é com a ausência de umidade.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

FAPESP 2009/04843-7, 2011/17126-1

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O tratamento da má oclusão de Classe II sem extrações dentárias vem ganhando popularidade na comunidade ortodôntica já há três décadas. Aparelhos funcionais fixos vêm sendo utilizados por profissionais, de maneira crescente, para promover compensações dentoalveolares e corrigir a má oclusão de Classe II. Os efeitos mais significativos são observados em pacientes com padrão de crescimento horizontal. Um caso clínico será relatado com o uso do aparelho fixo Twin Force Bite Corrector em uma paciente do sexo feminino, para a correção da Classe II. Esse dispositivo de ancoragem fixa dispensa o uso de aparelhos funcionais removíveis e não necessita da cooperação do paciente.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Avaliamos a influência do diâmetro e do modo de preparação do orifício piloto na resistência ao arrancamento e no torque de inserção dos parafusos pediculares com diâmetro interno cônico. MÉTODOS: Ensaios mecânicos foram realizados com parafusos pediculares com alma cônica e diâmetro de 4,2mm e 5,2mm inseridos nos pedículos vertebrais lombares de suínos. O orifício piloto foi confeccionado com de broca e sondas (pontiaguda e cortante) com diferentes diâmetros. RESULTADOS: Testando o parafuso de 4,2mm a perfuração com orifício igual ou inferior ao menor diâmetro interno do parafuso, aumentou o torque e a resistência ao arrancamento. Perfurações com diferentes instrumentos apresentaram comportamento semelhante. Perfurações com sondas permitiram que orifícios confeccionados com dimensões superiores ao menor diâmetro interno do parafuso apresentassem resistência semelhante a das perfurações com dimensões iguais ao menor diâmetro interno do implante, realizadas com sondas e brocas. CONCLUSÕES: Nos de 4,2 mm o diâmetro e o modo de preparação do orifício influenciam o torque e a resistência, nos de 5,2 mm apenas o torque de inserção. Não há correlação entre força de arrancamento e torque de inserção. Nível de evidência II, Estudos terapêuticos - Investigação dos Resultados do Tratamento.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As características das más-oclusões de pacientes com fissura labiopalatal em geral guardam correlação com a classificação da malformação, levando a diferentes níveis de gravidade e prognóstico para o tratamento ortodôntico. Desta forma, serão apresentados casos clínicos exemplificando os tipos de fissura e suas particularidades nas condutas terapêuticas, demonstrando ainda, a importância da Ortodontia no preparo dos pacientes para realização de enxerto ósseo alveolar e cirurgia ortognática.