884 resultados para Analysis of variance (ANOVA)
Resumo:
Syagrus picrophylla belongs to the Arecaceae family. Its propagation is made by seeds; however there is a lack of information in the literature about its seed germination. The objective of this work was to evaluate the effects of temperature and scarification on the germination of S. picrophylla seeds. The experiment was carried out at the State University of São Paulo, Jaboticabal Campus, Brazil. The experimental design was entirely randomized in a factorial arrangement 5 x 2 (five temperature conditions combined with or without mechanical scarification. The number of germinated seeds that showed primary root protrusion was noted daily, and when the germination was stabilized, the germination (%G) and germination rate (GR) were calculated. The analysis of variance (ANOVA) was carried out for means comparing by the Tukey test at 5% confidence level. It was concluded that the greatest %G were obtained at 20-30 degrees C (62%) and 25-35 degrees C (59%) alternated temperatures; %G and GR were similar for both scarified and non-scarified seeds, and there was a faster germination at 20-30 degrees C alternated temperature.
Resumo:
O conceito de superfície geomórfica permite uma interligação entre os diferentes ramos da ciência do solo, tais como geologia, geomorfologia e pedologia. Esta associação favorece a compreensão da distribuição espacial dos solos na paisagem, e torna possível compreender o comportamento dos atributos do solo, que estão principalmente relacionadas com a estratigrafia e formas do relevo. Assim, este estudo visa à aplicação da estatística multivariada para categorizar superfícies geomórficas em uma litossequência arenito-basalto, de modo a fornecer uma base para a avaliação do solo em áreas afins. A área de estudo está localizada no município de Pereira Barreto, São Paulo, Brasil. A área escolhida possui 530 hectares, onde foram localizadas e mapeadas três superfícies geomórficas (I, II e III). Na área, 134 amostras foram coletadas nas profundidades de 0,0-0,2 m e 0,8-1,0 m, foram determinados os conteúdos de areia, silte e argila, pH em CaCl2, conteúdo de MO, P, Ca, Mg, K, Al e H+Al. Com base nos resultados, foram realizadas a análise univariada e multivariada de variância, clusters e principal componente, a fim de comparar as três superfícies geomórficas. A análise estatística univariada dos atributos do solo não foi eficiente na identificação das três superfícies geomórficas. Utilizando-se os atributos físicos e químicos do solo, as técnicas estatísticas multivariada permitiram à separação dos três grupos de corpos naturais do solo que foram equivalentes as três superfícies geomórficas mapeadas. Estes resultados são interessantes, pois demonstram a viabilidade da utilização de classificação numérica das superfícies geomórficas para ajudar no mapeamento de solo.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Sixteen cats were used to compare the cardiovascular and anesthetic effects of remifentanil (REMT) or alfentanil (ALF) in propofol-anesthetized cats undergoing ovariohysterectomy. After premedication with acepromazine, anesthesia was induced and maintained with a constant rate infusion of propofol (0.3 mg/kg/min). REMT or ALF infusions were administered simultaneously with propofol. Heart rate (HR), systolic arterial pressure (SAP), pulse oximetry (SpO(2)), rectal temperature (RT), and response to surgical stimulation were recorded at predefined time points during anesthesia. Data [mean +/- standard deviation (SD)] were analyzed by analysis of variance (ANOVA) for repeated measures followed by a Dunnett's test and Student t-test (P < 0.05). SAP was significantly lower in ALF group than in REMI group. Extubation time was significantly shorter in REMI than in ALF group. Overall infusion rate of REMI and ALF was 0.24 +/- 0.05 mu g/kg/min and 0.97 +/- 0.22 mu g/kg/min, respectively. The combination of propofol and REM! or ALF provided satisfactory anesthesia in cats undergoing ovariohysterectomy. (C) 2011 ISFM and AAFP. Published by Elsevier Ltd. All rights reserved.
Resumo:
Purpose: This study compared the maintenance of tightening torque in different retention screw types of implant-supported crowns.Materials and Methods: Twelve metallic crowns in UCLA abutments cast with cobalt-chromium alloy were attached to external hexagon osseointegrated implants with different retention screws: group A: titanium alloy retention screw; group B: gold alloy retention screw with gold coating; group C: titanium alloy retention screw with diamond-like carbon film coating; and group D: titanium alloy retention screw with aluminum titanium nitride coating. Three detorque measurements were obtained after torque insertion in each replica. Data were evaluated by analysis of variance (ANOVA), Tukey's test (P < 0.05), and t test (P < 0.05).Results: Detorque value reduced in all groups (P < 0.05). Group A retained the highest percentage of torque in comparison with the other groups (P < 0.05). Groups B and D retained the lowest percentage of torque without statistically significant difference between them (P < 0.05).Conclusions: All screw types exhibited reduction in the detorque value. The titanium screw maintained the highest percentage of torque whereas the gold-coated screw and the titanium screw with aluminum titanium nitride coating retained the lowest percentage. (Implant Dent 2012;21:46-50)
Resumo:
The extent of separation between the maxillary and mandibular teeth in the fabrication of interocclusal splints designed to achieve efficiency and muscle relaxation is controversial and undefined in the literature. Based on this premise, the aim of this study was to evaluate the effect of interocclusal splint thicknesses of 3 and 6 millimeters on the electrical activity of the anterior temporal and masseter muscles during rest and dental clenching. Twenty asymptomatic individuals (10 males and 10 females) were selected using the Research Diagnostic Criteria (RDC). Electromyography (EMG) was performed both with and without the 3- and 6-mm splints using the Bio EMG software package, which recorded values given in microvolts (mu V). The results, which were assessed using analysis of variance (ANOVA) to a 5% significance level (p < 0.05), showed increased electrical activity of the masticatory muscles during dental clenching compared with at rest, with greater activity in the masseter muscle. The electrical activity did not differ according to the thickness of the splints or between males and females. We can conclude that both splint thicknesses are effective in treating muscle hyperactivity given their similar clinical behavior for asymptomatic individuals.
Resumo:
OBJECTIVE: The purpose of this study was to evaluate the thickness of the periodontal ligament of rat molars during orthodontic tooth movement (OTM). METHODS: Thirty Wistar rats were divided into three groups of 10 animals each: GI, GII and GIII and the mice were euthanized at 7, 14 and 21 days, respectively. Experimental subjects were compared to their respective controls by the Mann-Whitney test. Comparison of values between compression and tension sides were performed during the same and different time periods through Analysis of Variance (ANOVA), Kruskal-Wallis test and, subsequently, Tukey's test. RESULTS: Groups GI and GII showed decreased PDL size in the apical regions of the mesiobuccal root and in the cervical region of the distobuccal root. There was also an increased PDL in the cervical regions of the mesiobuccal root, apical region of the distobuccal root and middle region of both roots. CONCLUSION: The reduction and increase in PDL size were seen in the same root, which characterizes tooth inclination. The apical, middle and cervical regions were compared with one another in each time period and at three times: 7, 14 and 21 days. They were also compared in each region, confirming a tipping movement in GI and GII and a gradual decreased intensity between GI to GII, reaching normal dimension in GIII.
Resumo:
Background: the poor predictability of periodontal regenerative treatment of Class III furcation defects stimulates the study of alternatives to improve its results, such as the use of polypeptide growth factors. The objective of this study was to evaluate, both histologically and histometrically, the effects of topical application of basic fibroblast growth factor (b-FGF) associated with guided tissue regeneration (GTR) in the treatment of Class III defects surgically induced in dogs.Methods: All second and fourth premolars of 5 mongrel dogs were used and randomly assigned to one of three treatment groups: group 1 (control), treated with scaling and root planing, tetracycline hydrochloride (125 mg/ml) conditioning, and GTR with a collagen membrane; group 2, same treatment as group 1 plus 0.5 mg of b-FGF; group 3, same treatment as group 1 plus 1.0 mg of b-FGF. After a 90-day healing period, routine histologic processing and staining with hematoxylin and eosin and Masson trichrome were performed.Results: the descriptive analysis indicated better regenerative results in both groups treated with b-FGF while the histometric data, analyzed by means of analysis of variance (ANOVA), showed greater filling of the defects in group 2 in comparison to the defects in groups 3 and 1, respectively, which was represented by a smaller area of plaque-occupied space (P = 0.004) as well as a greater amount of newly formed cementum (P = 0.002).Conclusions: These results indicate that b-FGF, especially in smaller doses, may enhance the regenerative results in Class III furcation lesions, leading to greater filling of these defects with both mineralized and non-mineralized tissues.
Resumo:
Background: the purpose of this study was to evaluate the effect of a selective cyclooxygenase-2 inhibitor on the progression of alveolar bone loss in an experimental periodontitis model in rats.Methods: One hundred eighty (180) Wistar rats were separated into 3 experimental groups. Cotton ligatures were placed at the gingival margin level of lower right first molars. The rats were randomly assigned to one of the following groups that received: a daily oral dose of 10 mg/kg body weight of celecoxib (Ce1); 20 mg/kg body weight of celecoxib (Ce2); or 10 ml/kg of saline solution (C). Serum levels of celecoxib and white blood cell count were determined. Standardized digital radiographs were taken after sacrifice at 3, 5, 10, 18, and 30 days to measure the amount of bone loss around the mesial root surface of the first molar tooth in each rat.Results: Two-way analysis of variance (ANOVA) indicated that groups treated with celecoxib had significantly less bone loss compared to controls (P <0.0001) and that there was a significant interaction between treatment with celecoxib and time (P <0.03). Post-hoc comparisons showed that in both groups treated with celecoxib, the bone loss became significant only after 10 days of ligature placement, while in the control group it was already significant after 5 days. However, differences in mean bone loss between control and Ce1 were significant only at 18 days and, between control and Ce2, at 5 and 18 days. There was no significant difference in bone loss among experimental groups at the end of the experimental period.Conclusion: These data provide evidence that systemic therapy with celecoxib can modify the progression of experimentally induced periodontitis in rats.
Resumo:
Statement of the problem. In selecting a disinfectant for dental prostheses, compatibility between the disinfectant and the type of denture base material must be considered to avoid adverse effects on the hardness of the acrylic resin.Purpose. This study investigated the hardness of 2 denture base resins after disinfection and long-term water immersion.Material and methods. Thirty-two disk-shaped specimens (13 mm in diameter and 8 mm thick) were fabricated from each resin (Lucitone 550 and QC-20), polished, stored in water at 37degreesC for 48 hours, and submitted to hardness tests (Vickers hardness number [VHN]) before disinfection. Disinfection methods included scrubbing with 4% chlorhexidine gluconate for 1 minute, immersion for 10 minutes in I of the tested disinfectant Solutions (n=8) (3.78% sodium perborate, 4% chlorhexidine gluconate, or 1% sodium hypochorite), and immersion in water for 3 minutes. The disinfection procedures were repeated 4 times, and 12 hardness measurements were made on each specimen. Control specimens (not disinfected) were stored in water for 56 minutes. Hardness tests (VHN) were also performed after 15, 30, 60, 90, and 120 days of storage in water. Statistical analyses of data were conducted with a repeated measures 3-way analysis of variance (ANOVA) and Tukey post-hoc test (alpha=.05).Results. Mean values +/- SD for Lucitone 550 (16.52 +/- 0.94 VHN) and QC-20 (9.61 +/- 0.62 VHN) demonstrated a significant (P<.05) decrease in hardness after disinfection, regardless of material and disinfectant solutions used (Lucitone 550: 15.25 +/- 0.74; QC-20: 8.09 +/- 0.39). However, this effect was reversed after 15 days of storage in water. Both materials exhibited a continuous increase (P<.05) in hardness values for up to 60 days of water storage, after which no significant change was observed.Conclusion. Within the limitations of this in vitro study, QC-20 and Lucitone 550 specimens exhibited significantly lower hardness values after disinfection regardless of the disinfectant solution used.
Resumo:
This investigation studied the effects of disinfectant solutions on the hardness of acrylic resin denture teeth. The occlusal surfaces of 64 resin denture teeth were ground flat with abrasives up to 400-grit silicon carbide paper. Measurements were made after polishing and after the specimens were stored in water at 37 degreesC for 48 h. The specimens were then divided into four groups and immersed in chemical disinfectants (4% chlorhexidine; 1% sodium hypochlorite and sodium perborate) for 10 min. The disinfection methods were performed twice to simulate clinical conditions and hardness measurements were made. Specimens tested as controls were immersed in water during the same disinfection time. Eight specimens were produced for each group. After desinfection procedures, testing of hardness was also performed after the samples were stored at 37 degreesC for 7, 30, 60, 90 and 120 days. Data were analysed using two-way analysis of variance (anova) and Tukey's test at 95% confidence level. According to the results, no significant differences were found between materials and immersion solutions (P > 0.05). However, a continuous decrease in hardness was noticed after ageing (P < 0.05). It was conclude that the surfaces of both acrylic resin denture teeth softened upon immersion in water regardless the disinfecting solution.
Resumo:
This study evaluated the shear bond strength (SBS) and stability of commercially pure titanium (CP Ti)/repair material interfaces promoted by different repair systems. One hundred CP Ti cast discs were divided into five repair system groups: 1) Epricord (EP); 2) Bistite 11 DC (BT); 3) Cojet (CJ); 4) Scotchbond Multi-Purpose Plus (SB) (control group); and 5) Cojet Sand plus Scotchbond Multi-Purpose Plus (CJSB). The specimens were stored in distilled water for 24 hours at 37 degrees C, thermal cycled (5000 cycles, 5 degrees-55 degrees C) and stored under the same conditions for either 24 hours or six months (n=10). SBS was tested and the data were analyzed by two-way analysis of variance (ANOVA) and Tukey test (alpha=.05). Failure mode was determined with a stereomicroscope (20x). The repair system, storage time, and their interaction significantly affected the SBS (p<0.001). At 24 hours, CJSB exhibited the highest SBS value, followed by CJ. At six months, these two groups had similar mean SBS (p>0.05) and higher means in comparison to the other groups. For both storage times, BT presented the lowest SBS, while the EP and SB groups did not differ significantly from one another (p>0.05). There were no significant differences in SBS between the storage times for the groups EP and CJ (p>0.05). The groups BT, SB, and CJSB showed 100% adhesive failure, irrespective of storage time. The CJSB group showed the highest SBS at both storage times. At six months, the CJ group exhibited a similar SBS mean value when compared to the CJSB group. Water storage adversely affected the groups BT, SB (control group), and CJSB. Considering SBS values, stability, and the failure mode simultaneously, the CJ group showed the best CP Ti repair performance.