425 resultados para Adjuvantes imunológicos
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Agronomia (Produção Vegetal) - FCAV
Resumo:
The application technology shows many parameters related to the quality of the application, one is the droplet spectrum, which is influenced by the spray nozzles and the adjuvant used. Therefore, the objective of this work was estimate the behavior of the droplet spectrum generated with different nozzles and different adjuvants. The experiment was installed containing four solutions from different type adjuvant dilution, as vegetal oil, mineral oil, surfactant and drift reduction, which were applied with two nozzle, one pre-orifice flat fan (DG 8003 VS) and other of air induction flat fan (AI 8003 VS), totaling 8 treatments with 3 repetitions. The experiment was realized in ideal weather conditions for spraying. The treatments averages were compared using Confidence Interval at 95% probability and the correlations between variables were analyzed using Pearson at 5% of probability. The analysis of droplet spectrum showed different behavior for each adjuvant and nozzle. The surfactant treatment showed VMD superior for all treatments when sprayed with AI nozzles. For the %vol.<100 µm the lowest value found was for the AI nozzle in combination with the surfactant. The significant correlations found for the nozzles AI and DG were negative between VMD and %vol.<100 µm. It can be concluded that the values of DMV and %vol.<100 µm showed that the nozzle with pre-orifice have droplet spectrum more prone to drift. The surfactant showed to be the best drift reduction technique when combined with the AI nozzle.
Resumo:
The Asian rust currently is the main disease of soybean culture, having as characteristics the difficult control, by start at the bottom of plants where penetration of the droplets is harder. The fine droplets has been used with the intention of improve the penetration and increase efficiency of agrochemicals, but that are losses by drift easily. New products have been developed to increase deposition of the drops at targets. The aim of this work was evaluate the TA- 35 capacity to improving the deposition of fungicides spray solution with or without mineral oil by aerial and ground applications. Was used a factorial 3x2, three spray solutions composed by Priori Xtra (concentrated suspension of azoxystrobin 200 g L-1 + cyproconazole 80 g L-1 ) mixed with adjuvants, Nimbus (emulsifiable concentrate containing aliphatic hydrocarbons 428 g L-1 ) and TA-35 (soluble concentrate containing sodium lauryl ether sulfate, surfactants, sequestering agents and emulsifiers), in aerial and ground applications. In ground applications was used 50 L ha-1 , TXA 8002 VS spray nozzles and on aerials was used 15 L ha-1 , Turboaero atomizer, both applying fine droplets. Was utilized the Brilliant Blue (FD & C n. 1) tracer to determine the deposits. There were used glass slides as targets to collect spray droplets. After to extract the tracer of the targets using distilled water, the samples were analyzed by spectrophotometry, thereby was possible quantify the tracer deposited on each glass slide. A study to evaluate possible losses of the tracer by degradation or retention also was done. The comparative analysis of treatments was done by statistical method "Confidence Interval for Differences Between the Averages" with 95% of confidence degree (IC95%). There was degradation or retention of the tracer between the processes of application of the droplets and the processing of the samples. The deposition averages with the presence of TA-35 were greatest for both sprayers however, there were not significant differences among the treatments. The viability of TA-35 use may consider other parameters or complementary studies.
Resumo:
This study aimed to verify the influence of adjuvants on the droplet spectrum of an air induction nozzle. The experiment used nine spray solutions, one including only water and eight containing adjuvants: Nimbus® (mineral oil), Óleo vegetal Nortox (vegetal oil), Li-700® (a mixture of lecithin and propionic acid), Agral® (nonyl phenoxy poly ethanol), In-Tec® (nonyl phenol ethoxylate), Antideriva (nonyl phenol ethoxylate), Silwet® L-77 Ag (copolymer polyester and silicon) and TA 35 (sodium lauryl ether sulfate). A flat fan air induction nozzle Hypro® Guardian Air 110 03 was used for the droplet spectrum evaluation. The study was conducted at the Laboratory for Particle Size Analysis (Lapar), at FCAV/UNESP, Jaboticabal/SP - Brazil. The determination of the droplet spectrum characteristics (Volume Median Diameter/VMD, percentage of droplets smaller than 100 micrometers and span) was carried out by a particle size analyzer by laser diffraction Mastersizer S (Malvern Instruments). For statistical analysis the mean values were compared using Confidence Interval at 95% (CI 95%). The results showed that for the Hypro® GA air induction nozzle the oil based adjuvants (Óleo Vegetal Nortox e Nimbus®) increased the VMD. The percentage of droplets smaller than 100 micrometers was lower for the Agral®, Antideriva, In-Tec® e TA 35, in comparison with the Óleo Vegetal Nortox and Li-700®. The span was higher for the oil based adjuvants (Óleo Vegetal Nortox e Nimbus®) and lower for the TA 35 (sodium lauryl ether sulfate), showing that the TA 35 adjuvant has a potential to improve the quality of the droplet spectrum of the Hypro® GA 11003 nozzle.
Resumo:
2014
Resumo:
2016
Resumo:
Adjunctive therapeutic strategies that modulate the inflammatory mediators can play a significant role in periodontal therapy. In this double-blind, placebo-controlled study, 60 subjects diagnosed as periodontitis patients were evaluated for 28 days after periodontal treatment combined with selective cyclooxygenase-2 (COX-2) inhibitor. The experimental group received scaling and root planning (SRP) combined with the Loxoprofen antiinflammatory drug (SRP+Loxoprofen). The control group received SRP combined with placebo (SRP+placebo). Plaque index (PI), probing pocket depth (PD) and bleeding on probing (BOP) were monitored with an electronic probe at baseline and after 14 and 28 days. Both groups displayed clinical improvement in PD, PI and BOP. They also showed statistically similar values (p>0.05) of PD reduction on day 14 (0.4 mm) and on day 28 (0.6 mm). At the baseline, few deeper sites (>7 mm) from SRP+Loxoprofen group were responsible and most PD reduction was observed after 14 days (p<0.05). The percentage of remaining deep pockets (>7 mm) after 14 days in the SRP+Loxoprofen group was significantly lower (p<0.05) than in the SRP+placebo group. Loxoprofen presents potential effect as an adjunct of periodontal disease treatment, but long-term clinical trials are necessary to confirm its efficacy.
Resumo:
Studies evaluating immune function in obese humans and experimental animals indicate that the excess adiposity is associated with impaired in immune responses. Obesity is related to a higher rate of infections and to some types of cancer. Nutritional, metabolic and endocrine factors are implicated in the immunological changes. The adipose tissue directly produces substances with various functions related to immune system. Furthermore, some investigations suggest that certain types of weight reduction strategies can alter the immune function. Nevertheless, long-term studies should be carried out to address whether these changes positively affects the ability of these obese individuals to control infections and tumor development.
Resumo:
Várias terapias adjuvantes à cirurgia vêm sendo usadas para modular o processo cicatricial nas pregas vocais, entre elas a Mitomicina tópica (MTC). OBJETIVOS: Avaliar os efeitos da MTC no processo de cicatrização de pregas vocais de suínos 30 dias após exérese de fragmento de mucosa com laser de CO2 mediante a mensuração da deposição de colágeno. FORMA DE ESTUDO: Experimental em suínos. MATERIAIS E MÉTODOS: Dois grupos de 6 suínos cada foram avaliados após exérese de fragmento de mucosa de prega vocal a laser de CO2 (grupo controle sem uso e grupo experimento com uso de MTC tópica). Após 30 dias os animais foram submetidos à eutanásia, sendo coletadas amostras das pregas vocais para análise histológica, a fim de quantificar a deposição de colágeno mediante coloração de Picrosirius Red. RESULTADOS: A média da área do colágeno total das pregas vocais do grupo controle foi de 2648,03 µm2, enquanto a média do colágeno total das pregas vocais do grupo experimento foi de 2200,30 µm2 (p = 0,0043). CONCLUSÃO: A MTC usada topicamente após a exérese de fragmento de mucosa da prega vocal a laser de CO2 em suínos, diminui, significativamente, a deposição do colágeno total.