703 resultados para Adjustable suture
Resumo:
OBJECTIVES: To evaluate the influence of flap tension on the tearing characteristics of mucosal tissue samples in relation to various suture and needle characteristics. MATERIAL AND METHODS: Lining and masticatory mucosal tissue samples obtained from pig jaws were prepared for in vitro testing. Tension tearing diagrams of 60 experiments were traced for 3-0, 5-0 and 7-0 sutures with applied forces up to 20 N. In the second part, the same experiments were repeated with 100 diagrams to test the influence of needle characteristics with 5-0 and 6-0 sutures using only gingival tissue samples. RESULTS: 3-0 sutures mainly lead to tissue breakage at an average of 13.4 N. In contrast, 7-0 sutures only resulted in breakage of the thread at a mean applied force of 3.7 N. With 5-0 sutures, both events occurred at random at a mean force of 14.6 N. Irrespective of the needle characteristics, the mean breaking force for gingival samples with 5-0 and 6-0 sutures was approximately 10 N. CONCLUSIONS: Tissue trauma may be reduced by choosing finer suture diameters, because thinner (6-0, 7-0) sutures lead to thread breakage rather than tissue breakage.
Resumo:
BACKGROUND: Secondary intraocular lens (IOL) implantation is exposed to an increased risk of complications, including endophthalmitis and retinal detachment. The present analysis compares the outcomes and complications experienced in our own series of patients. PATIENTS AND METHODS: We retrospectively reviewed a consecutive series of secondary posterior chamber IOL implantations performed in a single centre, two surgeon setting over a period of 8 years and with a follow up-time of at least 4 months. RESULTS: Between 1997 and 2005, 75 patients received a sulcus-supported secondary IOL without suture fixation, whereas suture fixation was required in 137 instances. Visual acuity improved in both groups (group 1: from 0.36 +/- 0.39 (0.01-1.2) to 0.73 +/- 0.33 (0.02-1.0; p = 0.18); group 2: from 0.33 +/- 0.34 (0.02-1.0) to 0.46 +/- 0.33 (0.01-1.0; p = 0.006), but more pronounced in eyes not requiring suture fixation (p = 0.012). IOL placement was more likely to be combined with endophacoemulsification in the not suture-fixed IOLs (12.7 vs. 5.3 %). In contrast, retinal tears (10.6 vs. 8.6 %, respectively) and retinal detachment (5.3 vs. 2.2 %, respectively) were equally distributed. In the early postoperative phase, IOP was lower in suture-fixed eyes, which showed a higher incidence of minor intraocular haemorrhages and cystoid macular edema (5.3 vs. 8.0 %); late complications up to 5 years postoperatively were equally distributed. CONCLUSION: A preoperatively less complicated anterior segment situation and a lower incidence of postoperative macular edema may account for a better visual outcome after placement of a sulcus supported IOLs without suturing. If required, suture fixation may be performed without exposing the eye to an increased risk of late postoperative complications.
Resumo:
Although U-clip anastomoses were studied for hemodynamics and patency, their potential for unimpeded growth after congenital cardiovascular surgery has not been investigated yet. In 53 children aged 2.1+/-3.3 years operated on between March 1998 and August 2005 growth of U-clip (U) vs. polypropylene running sutured (P) anastomoses in coarctation repair (Coarc; n=26), bi-directional Glenn (BDG; n=13) and arterial switch operation (ASO; n=14) was retrospectively analysed. Coarc showed 2.39+/-4.33 vs. 3.09+/-2.24 mm of growth during the observation period (21+/-16 vs. 30+/-27 months); no growth (0 vs.16%), restenosis (14 vs. 37%) and reinterventions (14 vs. 11%) were similar (all in U vs. P, P=ns). BDG showed 3.68+/-3.43 vs. 2.50+/-2.55 mm (P=ns) of growth during 15+/-5 vs. 29+/-18 months (P=0.046); no growth (17 vs. 0%), stenosis (0 vs. 14%) and reinterventions (0%) were similar in U vs. P, respectively (P=ns). Main pulmonary artery (MPA) anastomosis in ASO showed 0.28+/-1.73 vs. 1.30+/-3.16 mm of growth during 8+/-14 vs. 28+/-28 months; no growth (60 vs. 14%), stenosis (50 vs. 63%) and reinterventions (0%) were similar (all in U vs. P, P=ns). Anastomotic growth, stenosis and reintervention rates show no difference between interrupted U-clip and polypropylene running sutured technique in Coarc repair, BDG and MPA anastomosis in ASO.
Resumo:
A compact adjustable focusing system for a 2 MeV H- RFQ Linac is designed, constructed and tested based on four permanent magnet quadrupoles (PMQ). A PMQ model is realised using finite element simulations, providing an integrated field gradient of 2.35 T with a maximal field gradient of 57 T/m. A prototype is constructed and the magnetic field is measured, demonstrating good agreement with the simulation. Particle track simulations provide initial values for the quadrupole positions. Accordingly, four PMQs are constructed and assembled on the beam line, their positions are then tuned to obtain a minimal beam spot size of (1.2 x 2.2) mm^2 on target. This paper describes an adjustable PMQ beam line for an external ion beam. The novel compact design based on commercially available NdFeB magnets allows high flexibility for ion beam applications.
Resumo:
An adjustable art table was designed for the artists at Passion Works Studio to fulfill a need for a wheelchair-friendly art table. The client desired that the table be sturdy, not electronic and can be used by multiple users. In response, a mechanical approach was taken and various raising devices were explored. A mechanical height adjustment would make for a more stable table and would not require any electricity or motor to adjust. The table also was built with a large, smooth tabletop designed specifically for multiple users making art. The highlight feature is the height adjustment which allows the table to adjust between 29 and 42.5 inches. The table requires just one person to raise, and two people to lower. To raise the table, an individual only needs to unlock the legs and then press in a button to activate the gas springs, which raise the table. Once the table is set to the desired height, the table can lock into place securely. To lower the table, one person must activate the gas springs and push down simultaneously with another person pushing down on the other side of the table. There is enough room for three people, depending on the size of the wheelchairs. With no wheelchairs, as many as six people can use the table. Therefore, the specifications were met, since it raises and lowers within the desired range, and it provides a solid surface for multiple users to do art work.
Resumo:
The Jinshajiang suture zone, located in the eastern part of the Tethyan tectonic domain, is noticeable for a large-scale distribution of Late Jurassic to Triassic granitoids. These granitoids were genetically related to the evolution of the Paleo-Tethys Ocean. The Beiwu, Linong and Lunong granitoids occur in the middle zone of the Jinshajiang Suture Zone, and possess similar geochemical features, indicating they share a common magma source. SIMS zircon U-Pb dating reveals the Beiwu, Linong and Lunong granitic intrusions were emplaced at 233.9±1.4 Ma (2 sigma), 233.1 ±1.4 Ma (2 sigma) and 231.0±1.6 Ma (2 sigma), respectively. All of these granitoids are enriched in abundances of Si (SiO2 =65.2-73.5 wt.%), and large-ion-lithophile-elements (LILEs), but depleted in high-field-strength-elements contents (HFSEs, e.g., Nb, Ta, Ti). In addition, they have low P2O5 contents (0.06-0.11 wt.%), A/CNK values ([molecular Al2O3/(CaO+Na2O+K2O)], mostly<1.1) and 10000Ga/Al ratios (1.7-2.2), consistent with the characteristics of I-type granites. In terms of isotopic compositions, these granitoids have high initial 87Sr/86Sr ratios (0.7078-0.7148), Pb isotopic compositions [(206Pb/204Pb)t=18.213-18.598, (207Pb/204Pb)t=15.637-15.730 and (208Pb/204Pb)t=38.323-38.791], zircon d18O values (7. per mil-9.3 per mil) and negative eNd(t) values (-5.1 to -6.7), suggesting they were predominantly derived from the continental crust. Their Nb/Ta ratios (average value=8.6) are consistent with those of the lower continental crust (LCC). However, variable ?Hf(t) values (-8.6 to +2.8) and the occurrences of mafic microgranular enclaves (MMEs) suggest that mantle-derived melts and lower crustal magmas were involved in the generation of these granitoids. Moreover, the high Pb isotopic ratios and elevated zircon d18O values of these rocks indicate a significant contribution of the upper crustal composition. We propose a model in which the Beiwu, Linong and Lunong granitoids were generated under a late collisional or post-collisional setting. It is possible that this collision was completed before Late Triassic. Decompression induced mantle-derived magmas underplated and provided the heat for the anatexis of the crust. Hybrid melts including mantle-derived and the lower crustal magmas were then generated. The hybrid melts thereafter ascended to a shallow depth and resulted in some degree of sedimentary rocks assimilation. Such three-component mixing magmas source and subsequent fractional crystallization could be responsible for the formation of the Beiwu, Linong and Lunong granitoids.
Resumo:
This paper presents an algorithm for generating scale-free networks with adjustable clustering coefficient. The algorithm is based on a random walk procedure combined with a triangle generation scheme which takes into account genetic factors; this way, preferential attachment and clustering control are implemented using only local information. Simulations are presented which support the validity of the scheme, characterizing its tuning capabilities.
Resumo:
The field of exoskeletons and wearable devices for walking assistance and rehabilitation has advanced considerably over the past few years. Currently, commercial devices contain joints with stiff actuators that cannot adapt to unpredictable environments. These actuators consume more energy and may not be appropriate for human-machine interactions. Thus, adjustable compliant actuators are being cautiously incorporated into new exoskeletons and active orthoses. Some simulation-based studies have evaluated the benefits of incorporating compliant joints into such devices. Another reason that compliant actuators are desirable is that spasticity and spasmodic movements are common among patients with motor deficiencies; compliant actuators could efficiently absorb these perturbations and improve joint control. In this paper, we provide an overview of the requirements that must be fulfilled by these actuators while evaluating the behavior of leg joints in the locomotion cycle. A brief review of existing compliant actuators is conducted, and our proposed variable stiffness actuator prototype is presented and evaluated. The actuator prototype is implemented in an exoskeleton knee joint operated by a state machine that exploits the dynamics of the leg, resulting in a reduction in actuation energy demand and better adaptability to disturbances.
Resumo:
The coordinate growth of the brain and skull is achieved through a series of interactions between the developing brain, the growing bones of the skull, and the fibrous joints, or sutures, that unite the bones. These interactions couple the expansion of the brain to the growth of the bony plates at the sutures. Craniosynostosis, the premature fusion of the bones of the skull, is a common birth defect (1 in 3000 live births) that disrupts coordinate growth and often results in profoundly abnormal skull shape. Individuals affected with Boston-type craniosynostosis, an autosomal dominant disorder, bear a mutated copy of MSX2, a homeobox gene thought to function in tissue interactions. Here we show that expression of the mouse counterpart of this mutant gene in the developing skulls of transgenic mice causes craniosynostosis and ectopic cranial bone. These mice provide a transgenic model of craniosynostosis as well as a point of entry into the molecular mechanisms that coordinate the growth of the brain and skull.