973 resultados para Additive Fertigung, Lasersintern, Design for manufacture, Design for X,


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND:: The interaction of sevoflurane and opioids can be described by response surface modeling using the hierarchical model. We expanded this for combined administration of sevoflurane, opioids, and 66 vol.% nitrous oxide (N2O), using historical data on the motor and hemodynamic responsiveness to incision, the minimal alveolar concentration, and minimal alveolar concentration to block autonomic reflexes to nociceptive stimuli, respectively. METHODS:: Four potential actions of 66 vol.% N2O were postulated: (1) N2O is equivalent to A ng/ml of fentanyl (additive); (2) N2O reduces C50 of fentanyl by factor B; (3) N2O is equivalent to X vol.% of sevoflurane (additive); (4) N2O reduces C50 of sevoflurane by factor Y. These four actions, and all combinations, were fitted on the data using NONMEM (version VI, Icon Development Solutions, Ellicott City, MD), assuming identical interaction parameters (A, B, X, Y) for movement and sympathetic responses. RESULTS:: Sixty-six volume percentage nitrous oxide evokes an additive effect corresponding to 0.27 ng/ml fentanyl (A) with an additive effect corresponding to 0.54 vol.% sevoflurane (X). Parameters B and Y did not improve the fit. CONCLUSION:: The effect of nitrous oxide can be incorporated into the hierarchical interaction model with a simple extension. The model can be used to predict the probability of movement and sympathetic responses during sevoflurane anesthesia taking into account interactions with opioids and 66 vol.% N2O.

Relevância:

80.00% 80.00%

Publicador:

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Introduction: Computer-Aided-Design (CAD) and Computer-Aided-Manufacture (CAM) has been developed to fabricate fixed dental restorations accurately, faster and improve cost effectiveness of manufacture when compared to the conventional method. Two main methods exist in dental CAD/CAM technology: the subtractive and additive methods. While fitting accuracy of both methods has been explored, no study yet has compared the fabricated restoration (CAM output) to its CAD in terms of accuracy. The aim of this present study was to compare the output of various dental CAM routes to a sole initial CAD and establish the accuracy of fabrication. The internal fit of the various CAM routes were also investigated. The null hypotheses tested were: 1) no significant differences observed between the CAM output to the CAD and 2) no significant differences observed between the various CAM routes. Methods: An aluminium master model of a standard premolar preparation was scanned with a contact dental scanner (Incise, Renishaw, UK). A single CAD was created on the scanned master model (InciseCAD software, V2.5.0.140, UK). Twenty copings were then fabricated by sending the single CAD to a multitude of CAM routes. The copings were grouped (n=5) as: Laser sintered CoCrMo (LS), 5-axis milled CoCrMo (MCoCrMo), 3-axis milled zirconia (ZAx3) and 4-axis milled zirconia (ZAx4). All copings were micro-CT scanned (Phoenix X-Ray, Nanotom-S, Germany, power: 155kV, current: 60µA, 3600 projections) to produce 3-Dimensional (3D) models. A novel methodology was created to superimpose the micro-CT scans with the CAD (GOM Inspect software, V7.5SR2, Germany) to indicate inaccuracies in manufacturing. The accuracy in terms of coping volume was explored. The distances from the surfaces of the micro-CT 3D models to the surfaces of the CAD model (CAD Deviation) were investigated after creating surface colour deviation maps. Localised digital sections of the deviations (Occlusal, Axial and Cervical) and selected focussed areas were then quantitatively measured using software (GOM Inspect software, Germany). A novel methodology was also explored to digitally align (Rhino software, V5, USA) the micro-CT scans with the master model to investigate internal fit. Fifty digital cross sections of the aligned scans were created. Point-to-point distances were measured at 5 levels at each cross section. The five levels were: Vertical Marginal Fit (VF), Absolute Marginal Fit (AM), Axio-margin Fit (AMF), Axial Fit (AF) and Occlusal Fit (OF). Results: The results of the volume measurement were summarised as: VM-CoCrMo (62.8mm3 ) > VZax3 (59.4mm3 ) > VCAD (57mm3 ) > VZax4 (56.1mm3 ) > VLS (52.5mm3 ) and were all significantly different (p presented as areas with different colour. No significant differences were observed at the internal aspect of the cervical aspect between all groups of copings. Significant differences (p< M-CoCrMo Internal Occlusal, Internal Axial and External Axial 2 ZAx3 > ZAx4 External Occlusal, External Cervical 3 ZAx3 < ZAx4 Internal Occlusal 4 M-CoCrMo > ZAx4 Internal Occlusal and Internal Axial The mean values of AMF and AF were significantly (p M-CoCrMo and CAD > ZAx4. Only VF of M-CoCrMo was comparable with the CAD Internal Fit. All VF and AM values were within the clinically acceptable fit (120µm). Conclusion: The investigated CAM methods reproduced the CAD accurately at the internal cervical aspect of the copings. However, localised deviations at axial and occlusal aspects of the copings may suggest the need for modifications in these areas prior to fitting and veneering with porcelain. The CAM groups evaluated also showed different levels of Internal Fit thus rejecting the null hypotheses. The novel non-destructive methodologies for CAD/CAM accuracy and internal fit testing presented in this thesis may be a useful evaluation tool for similar applications.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Treatment of joint diseases such as osteoarthritis is difficult and requires extensive developments for adequate solutions to emerge. Continued innovation in projects explored in this thesis may be beneficial to understanding the requirements of the joint environment. This may then lead to constructs that perform desirably from both mechanical and biological standpoints, resulting in complete, tissue-engineered osteochondral solutions. This thesis investigated specific scaffold designs for bone and osteochondral tissue engineering, as well as the formation of complex criteria on which cartilage hydrogel scaffolds may be assessed. The combination of hydrogels and ceramics were found to maintain chondrogenesis, while the concentration of photoinitiators in photocrosslinkable hydrogel systems may be optimised to maximise mechanical properties and cell viability. Finally, viscoelasticity of hydrogel blends was assessed using oscillatory motion, demonstrating the property is tailorable.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Discusses a study conducted to determine the best development path for large wind turbine rotor design. Shape and number of blades, degrees of freedom allowed, and control strategy are considered. Manufacture and costs are also discussed. Two-bladed, stall-regulated, teetered rotors are more cost effective than three-bladed rotors. Single-bladed rotors can be even more cost-effective. No new manufacturing techniques are required. The most cost-effective rotor includes a hub constructed in wood/composite materials, bonded to the blades. There is strong incentive for the blade manufacturer to supply the complete rotor. (from author's abstract)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper describes progress on a project to utilise case based reasoning methods in the design and manufacture of furniture products. The novel feature of this research is that cases are represented as structures in a relational database of products, components and materials. The paper proposes a method for extending the usual "weighted sum" over attribute similarities for a ·single table to encompass relational structures over several tables. The capabilities of the system are discussed, particularly with respect to differing user objectives, such as cost estimation, CAD, cutting scheme re-use, and initial design. It is shown that specification of a target case as a relational structure combined with suitable weights can fulfil several user functions. However, it is also shown that some user functions cannot satisfactorily be specified via a single target case. For these functions it is proposed to allow the specification of a set of target cases. A derived similarity measure between individuals and sets of cases is proposed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose – To present key challenges associated with the evolution of system-in-package technologies and present technical work in reliability modeling and embedded test that contributes to these challenges. Design/methodology/approach – Key challenges have been identified from the electronics and integrated MEMS industrial sectors. Solutions to optimising the reliability of a typical assembly process and reducing the cost of production test have been studied through simulation and modelling studies based on technology data released by NXP and in collaboration with EDA tool vendors Coventor and Flomerics. Findings – Characterised models that deliver special and material dependent reliability data that can be used to optimize robustness of SiP assemblies together with results that indicate relative contributions of various structural variables. An initial analytical model for solder ball reliability and a solution for embedding a low cost test for a capacitive RF-MEMS switch identified as an SiP component presenting a key test challenge. Research limitations/implications – Results will contribute to the further development of NXP wafer level system-in-package technology. Limitations are that feedback on the implementation of recommendations and the physical characterisation of the embedded test solution. Originality/value – Both the methodology and associated studies on the structural reliability of an industrial SiP technology are unique. The analytical model for solder ball life is new as is the embedded test solution for the RF-MEMS switch.

Relevância:

60.00% 60.00%

Publicador: