621 resultados para AHARONOV-BOHM INTERFEROMETER


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the process of interferometric testing, the measurement result is influenced by the system structure, which reduces the measurement accuracy. To obtain an accurate test result, it is necessary to analyze the test system, and build the relationship between the measurement error and the system parameters. In this paper, the influences of the system elements which include the collimated lens and the standard surface on the interferometric testing are analyzed, the expressions of phase distribution and wavefront error on the detector are obtained, the method to remove some element errors is introduced, and the optimization structure relationships are given. (C) 2006 Elsevier GmbH. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new dual-frequency laser displacement measurement interferometer with nanometer precision has been developed. An eight-pass optical subdivision technology is proposed to improve resolution based on commercial interferometers. A static positioning error measuring method has been used to examine the precision and repeatability of the laser interferometer. An optical resolution of 1.24 nm and an accuracy of nanometer scale have been achieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Only the first- order Doppler frequency shift is considered in current laser dual- frequency interferometers; however; the second- order Doppler frequency shift should be considered when the measurement corner cube ( MCC) moves at high velocity or variable velocity because it can cause considerable error. The influence of the second- order Doppler frequency shift on interferometer error is studied in this paper, and a model of the second- order Doppler error is put forward. Moreover, the model has been simulated with both high velocity and variable velocity motion. The simulated results show that the second- order Doppler error is proportional to the velocity of the MCC when it moves with uniform motion and the measured displacement is certain. When the MCC moves with variable motion, the second- order Doppler error concerns not only velocity but also acceleration. When muzzle velocity is zero the second- order Doppler error caused by an acceleration of 0.6g can be up to 2.5 nm in 0.4 s, which is not negligible in nanometric measurement. Moreover, when the muzzle velocity is nonzero, the accelerated motion may result in a greater error and decelerated motion may result in a smaller error.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The theory of optical subdivision techniques of dual-frequency laser interferometers is stated. And a novel optical subdivision technique is proposed originally to enhance resolution of a commercial interferometer by adding some corner-cubes. Then the performance of the interferometer is tested. The interferometer resolution of 1.24 nm and the average error of below 2 nm are achieved by using the technique. The most novel of the optical subdivision technique is without lambda/4 plates. It is less sensitive to environmental changes, it has prodigious potential to improve resolution farther and it can reduce polarization mixing error. (C) 2007 Elsevier GmbH. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel monolithically integrated Michelson interferometer using intersecting twin-contact semiconductor optical amplifiers is proposed and implemented whereby the two arms are gain imbalanced to give enhanced noise suppression. Experimental OSNR improvements of 8.4 dB for pulses with durations 8 ps and by default ER of 14 dB are demonstrated for low driving currents of between 25 and 30 mA. This is believed to be the smallest Michelson interferometer to date.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An all-optical parity checker is proposed that requires only a single Mach-Zehnder interferometer. Simulation results demonstrate an 8dB improvement in extinction ratio at 10 Gb/s operation. © 1999 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of third-order dispersion in a Hong-Ou-Mandel interferometer is investigated using a ZnSe crystal as a dispersive medium. A value for the TOD coefficient of ZnSe is extracted which is consistent with literature values. © OSA 2013.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel monolithically integrated Michelson Interferometer using intersecting twincontact semiconductor optical amplifiers is proposed whereby the two arms are gain imbalanced to give noise suppression. Experimental OSNR improvements of 6.2dB for 8ps pulses is demonstrated. © 2005 Optical Society of America.