974 resultados para 3D surfaces


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: The aim of this study was to compare cone beam CT (CBCT) in a small field of view (FOV) with a solid-state sensor and a photostimulable phosphor plate system for detection of cavitated approximal surfaces. Methods: 257 non-filled approximal surfaces from human permanent premolars and molars were recorded by two intraoral digital receptors, a storage phosphor plate (Digora Optime, Soredex) and a solid-state CMOS sensor (Digora Toto, Soredex), and scanned in a cone beam CT unit (3D Accuitomo FPD80, Morita) with a FOV of 4 cm and a voxel size of 0.08 mm. Image sections were carried out in the axial and mesiodistal tooth planes. Six observers recorded surface cavitation in all images. Validation of the true absence or presence of surface cavitation was performed by inspecting the surfaces under strong light with the naked eye. Differences in sensitivity, specificity and agreement were estimated by analysing the binary data in a generalized linear model using an identity link function. Results: A significantly higher sensitivity was obtained by all observers with CBCT (p,0.001), which was not compromised by a lower specificity. Therefore, a significantly higher overall agreement was obtained with CBCT (p,0.001). There were no significant differences between the Digora Optime phosphor plate system and the Digora Toto CMOS sensor for any parameter. Conclusions: CBCT was much more accurate in the detection of surface cavitation in approximal surfaces than intraoral receptors. The differences are interpreted as clinically significant. A CBCT examination performed for other reasons should also be assessed for approximal surface cavities in teeth without restorations. © 2013 The British Institute of Radiology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Motivados por estudos experimentais acerca de monocamadas de metais de transição 3d sobre superfícies de Pd, nesta dissertação investigamos o complexo magnetismo de nanoestruturas, embebidas ou adsorvidas, em superfícies metálicas através de cálculos de primeiros princípios. Utilizamos o método RS-LMTO-ASA (Real Space - Linear MuffinTin Orbital - Atomic Sphere Approximation), o qual é baseado na teoria do funcional da densidade (DFT - Density Functional Theory) e implementado para o cálculo de estruturas magnéticas não colineares. Com este propósito, investigamos nanoestruturas embebidas e ligas (2 x 2) de metais 3d (Cr, Mn, Fe, Co e Ni) na superfície Pd (110), além de nanoestruturas de Cr adsorvidas sobre a superfície de Pd (111). Primeiro, para as nanoestruturas embebidas na superfície Pd (110), analisamos a variação do momento magnético de spin orbital com relação ao número de vizinhos e de valência dos metais 3d. Também mostramos que estas estruturas têm ordenamento magnético colinear, exceto as de Cr e Mn, que apresentam magnetismo não colinear associado à frustração geométrica. Para o caso de nanofios de Cr adsorvidos sobre a superfície de Pd (111), verificamos uma configuração colinear antiferromagnética para cadeias com até 9 átomos. Para o nanofio com 10 átomos obtivemos uma configuração tipo antiferromagnética inclinada (canted). No caso de nanoestruturas de Cr bidimensionais, verificamos complexas configurações magnéticas não colineares com diferentes quiralidades.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to determine whether image artifacts caused by orthodontic metal accessories interfere with the accuracy of 3D CBCT model superimposition. A human dry skull was subjected three times to a CBCT scan: at first without orthodontic brackets (T1), then with stainless steel brackets bonded without (T2) and with orthodontic arch wires (T3) inserted into the brackets' slots. The registration of image surfaces and the superimposition of 3D models were performed. Within-subject surface distances between T1-T2, T1-T3 and T2-T3 were computed and calculated for comparison among the three data sets. The minimum and maximum Hausdorff Distance units (HDu) computed between the corresponding data points of the T1 and T2 CBCT 3D surface images were 0.000000 and 0.049280 HDu, respectively, and the mean distance was 0.002497 HDu. The minimum and maximum Hausdorff Distances between T1 and T3 were 0.000000 and 0.047440 HDu, respectively, with a mean distance of 0.002585 HDu. In the comparison between T2 and T3, the minimum, maximum and mean Hausdorff Distances were 0.000000, 0.025616 and 0.000347 HDu, respectively. In the current study, the image artifacts caused by metal orthodontic accessories did not compromise the accuracy of the 3D model superimposition. Color-coded maps of overlaid structures complemented the computed Hausdorff Distances and demonstrated a precise fusion between the data sets.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

[EN] In this paper we present a variational technique for the reconstruction of 3D cylindrical surfaces. Roughly speaking by a cylindrical surface we mean a surface that can be parameterized using the projection on a cylinder in terms of two coordinates, representing the displacement and angle in a cylindrical coordinate system respectively. The starting point for our method is a set of different views of a cylindrical surface, as well as a precomputed disparity map estimation between pair of images. The proposed variational technique is based on an energy minimization where we balance on the one hand the regularity of the cylindrical function given by the distance of the surface points to cylinder axis, and on the other hand, the distance between the projection of the surface points on the images and the expected location following the precomputed disparity map estimation between pair of images. One interesting advantage of this approach is that we regularize the 3D surface by means of a bi-dimensio al minimization problem. We show some experimental results for large stereo sequences.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

[EN] In this paper, we present a vascular tree model made with synthetic materials and which allows us to obtain images to make a 3D reconstruction.We have used PVC tubes of several diameters and lengths that will let us evaluate the accuracy of our 3D reconstruction. In order to calibrate the camera we have used a corner detector. Also we have used Optical Flow techniques to follow the points through the images going and going back. We describe two general techniques to extract a sequence of corresponding points from multiple views of an object. The resulting sequence of points will be used later to reconstruct a set of 3D points representing the object surfaces on the scene. We have made the 3D reconstruction choosing by chance a couple of images and we have calculated the projection error. After several repetitions, we have found the best 3D location for the point.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work the growth and the magnetic properties of the transition metals molybdenum, niobium, and iron and of the highly-magnetostrictive C15 Laves phases of the RFe2 compounds (R: Rare earth metals: here Tb, Dy, and Tb{0.3}Dy{0.7} deposited on alpha-Al2O3 (sapphire) substrates are analyzed. Next to (11-20) (a-plane) oriented sapphire substrates mainly (10-10) (m-plane) oriented substrates were used. These show a pronounced facetting after high temperature annealing in air. Atomic force microscopy (AFM) measurements reveal a dependence of the height, width, and angle of the facets with the annealing temperature. The observed deviations of the facet angles with respect to the theoretical values of the sapphire (10-1-2) and (10-11) surfaces are explained by cross section high resolution transmission electron microscopy (HR-TEM) measurements. These show the plain formation of the (10-11) surface while the second, energy reduced (10-1-2) facet has a curved shape given by atomic steps of (10-1-2) layers and is formed completely solely at the facet ridges and valleys. Thin films of Mo and Nb, respectively, deposited by means of molecular beam epitaxy (MBE) reveal a non-twinned, (211)-oriented epitaxial growth as well on non-faceted as on faceted sapphire m-plane, as was shown by X-Ray and TEM evaluations. In the case of faceted sapphire the two bcc crystals overgrow the facets homogeneously. Here, the bcc (111) surface is nearly parallel to the sapphire (10-11) facet and the Mo/Nb (100) surface is nearly parallel to the sapphire (10-1-2) surface. (211)-oriented Nb templates on sapphire m-plane can be used for the non-twinned, (211)-oriented growth of RFe2 films by means of MBE. Again, the quality of the RFe2 films grown on faceted sapphire is almost equal to films on the non-faceted substrate. For comparison thin RFe2 films of the established (110) and (111) orientation were prepared. Magnetic and magnetoelastic measurements performed in a self designed setup reveal a high quality of the samples. No difference between samples with undulated and flat morphology can be observed. In addition to the preparation of covering, undulating thin films on faceted sapphire m-plane nanoscopic structures of Nb and Fe were prepared by shallow incidence MBE. The formation of the nanostructures can be explained by a shadowing of the atomic beam due to the facets in addition to de-wetting effects of the metals on the heated sapphire surface. Accordingly, the nanostructures form at the facet ridges and overgrow them. The morphology of the structures can be varied by deposition conditions as was shown for Fe. The shape of the structures vary from pearl-necklet strung spherical nanodots with a diameter of a few 10 nm to oval nanodots of a few 100 nm length to continuous nanowires. Magnetization measurements reveal uniaxial magnetic anisotropy with the easy axis of magnetization parallel to the facet ridges. The shape of the hysteresis is depending on the morphology of the structures. The magnetization reversal processes of the spherical and oval nanodots were simulated by micromagnetic modelling and can be explained by the formation of magnetic vortices.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Stereological tools are the gold standard for accurate (i.e., unbiased) and precise quantification of any microscopic sample. The past decades have provided a broad spectrum of tools to estimate a variety of parameters such as volumes, surfaces, lengths, and numbers. Some of them require pairs of parallel sections that can be produced by either physical or optical sectioning, with optical sectioning being much more efficient when applicable. Unfortunately, transmission electron microscopy could not fully profit from these riches, mainly because of the large depth of field. Hence, optical sectioning was a long-time desire for electron microscopists. This desire was fulfilled with the development of electron tomography that yield stacks of slices from electron microscopic sections. Now, parallel optical slices of a previously unimagined small thickness (2-5 nm axial resolution) can be produced. These optical slices minimize problems related to overprojection effects, and allow for direct stereological analysis, e.g., volume estimation with the Cavalieri principle and number estimation with the optical disector method. Here, we demonstrate that the symbiosis of stereology and electron tomography is an easy and efficient way for quantitative analysis at the electron microscopic level. We call this approach quantitative 3D electron microscopy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Stereological tools are the gold standard for accurate (i.e., unbiased) and precise quantification of any microscopic sample. The past decades have provided a broad spectrum of tools to estimate a variety of parameters such as volumes, surfaces, lengths, and numbers. Some of them require pairs of parallel sections that can be produced by either physical or optical sectioning, with optical sectioning being much more efficient when applicable. Unfortunately, transmission electron microscopy could not fully profit from these riches, mainly because of the large depth of field. Hence, optical sectioning was a long-time desire for electron microscopists. This desire was fulfilled with the development of electron tomography that yield stacks of slices from electron microscopic sections. Now, parallel optical slices of a previously unimagined small thickness (2-5nm axial resolution) can be produced. These optical slices minimize problems related to overprojection effects, and allow for direct stereological analysis, e.g., volume estimation with the Cavalieri principle and number estimation with the optical disector method. Here, we demonstrate that the symbiosis of stereology and electron tomography is an easy and efficient way for quantitative analysis at the electron microscopic level. We call this approach quantitative 3D electron microscopy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis represents the overview of hydrographic surveying and different types of modern and traditional surveying equipment, and data acquisition using the traditional single beam sonar system and a modern fully autonomous underwater vehicle, IVER3. During the thesis, the data sets were collected using the vehicles of the Great Lake Research Center at Michigan Technological University. This thesis also presents how to process and edit the bathymetric data on SonarWiz5. Moreover, the three dimensional models were created after importing the data sets in the same coordinate system. In these interpolated surfaces, the details and excavations can be easily seen on the surface models. In this study, the profiles are plotted on the surface models to compare the sensors and details on the seabed. It is shown that single beam sonar might miss some details, such as pipeline and quick elevation changes on the seabed when we compare to the side scan sonar of IVER3 because the single side scan sonar can acquire better resolution. However, sometimes using single beam sonar can save your project time and money because the single beam sonar is cheaper than side scan sonars and the processing might be easier than the side scan data.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Um mit den immer kürzer werdenden Produkteinführungszeiten Schritt halten zu können, die der harte Wettbewerb heute vorgibt, setzt die produzierende Industrie mehr und mehr auf das 3D-Drucken von Prototypen. Mit dieser Produktionsmethode lassen sich technische Probleme schon in der frühen Entwicklungsphase lösen. Dies spart Kosten und beschleunigt die Entwicklungsschritte. Die innovative PolyJetTM-Technologie von Objet setzt neue Maßstäbe im 3D-Drucken. 
Die Besonderheit: Modelle aus hauchdünnen Materialschichten. So können mit der 
PolyJetTM-Technologie detailgetreue Modelle extrem schnell, einfach und sauber realisiert werden – und das mit hervorragender Oberflächenqualität

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Arthroscopy is considered as "the gold standard" for the diagnosis of traumatic intraarticular knee lesions. However, recent developments in magnetic resonance imaging (MRI) now offer good opportunities for the indirect assessment of the integrity and structural changes of the knee articular cartilage. The study was to investigate whether cartilage-specific sequences on a 3-Tesla MRI provide accurate assessment for the detection of cartilage defects. METHODS A 3-Tesla (3-T) MRI combined with three-dimensional double-echo steady-state (3D-DESS) cartilage specific sequences was performed on 210 patients with knee pain prior to knee arthroscopy. Sensitivity, specificity, and positive and negative predictive values of magnetic resonance imaging were calculated and correlated to the arthroscopic findings of cartilaginous lesions. Lesions were classified using the modified Outerbridge classification. RESULTS For the 210 patients (1260 cartilage surfaces: patella, trochlea, medial femoral condyle, medial tibia, lateral femoral condyle, lateral tibia) evaluated, the sensitivities, specificities, positive predictive values, and negative predictive values of 3-T MRI were 83.3, 99.8, 84.4, and 99.8 %, respectively, for the detection of grade IV lesions; 74.1, 99.6, 85.2, and 99.3 %, respectively, for grade III lesions; 67.9, 99.2, 76.6, and 98.2 %, respectively, for grade II lesions; and 8.8, 99.5, 80, and 92 %, respectively, for grade I lesions. CONCLUSIONS For grade III and IV lesions, 3-T MRI combined with 3D-DESS cartilage-specific sequences represents an accurate diagnostic tool. For grade II lesions, the technique demonstrates moderate sensitivity, while for grade I lesions, the sensitivity is limited to provide reliable diagnosis compared to knee arthroscopy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Modeling and prediction of the overall elastic–plastic response and local damage mechanisms in heterogeneous materials, in particular particle reinforced composites, is a very complex problem. Microstructural complexities such as the inhomogeneous spatial distribution of particles, irregular morphology of the particles, and anisotropy in particle orientation after secondary processing, such as extrusion, significantly affect deformation behavior. We have studied the effect of particle/matrix interface debonding in SiC particle reinforced Al alloy matrix composites with (a) actual microstructure consisting of angular SiC particles and (b) idealized ellipsoidal SiC particles. Tensile deformation in SiC particle reinforced Al matrix composites was modeled using actual microstructures reconstructed from serial sectioning approach. Interfacial debonding was modeled using user-defined cohesive zone elements. Modeling with the actual microstructure (versus idealized ellipsoids) has a significant influence on: (a) localized stresses and strains in particle and matrix, and (b) far-field strain at which localized debonding takes place. The angular particles exhibited higher degree of load transfer and are more sensitive to interfacial debonding. Larger decreases in stress are observed in the angular particles, because of the flat surfaces, normal to the loading axis, which bear load. Furthermore, simplification of particle morphology may lead to erroneous results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Actualmente existen varios dispositivos que aceptan gestos sobre superficies táctiles, sean celulares, tabletas, computadores, etc. a los cuales las personas se acostumbran rápidamente a su uso y los aceptan como herramientas necesarias en su vida. Del mismo modo existen algunas aplicaciones que manejan entornos en 3D, y permiten captar gestos realizados con las manos, cuerpo, cabeza. Estas técnicas se han desarrollado mucho por separado pero se ha podido evidenciar en base a los artículos revisados que no existen muchos estudios que combinen las aplicaciones táctiles con las 3D manejadas por gestos en el aire. El presente trabajo muestra un prototipo que permite la comunicación y coordinación entre dos aplicaciones, una que muestra documentos representados por esferas en una aplicación con interacción táctil desarrollada en Unity que funciona sobre Android, y una segunda aplicación desarrollada también en Unity que maneja un entorno 3D con el que se interactúa mediante gestos realizados en el aire. Luego de algunos intentos la interacción entre ambas aplicaciones fue lograda implementando comunicación por sockets entre la aplicación en el dispositivo Android y la aplicación 3D que se encuentra alojada en un computador con Windows 7. La captura de gestos en el aire se realiza mediante el sistema Tracking Tools desarrollado por la compañía Optitrack que captura los movimientos con cámaras infrarrojas y marcadores en los dedos. Este sistema envía los datos de los gestos a nuestra aplicación 3D. Estos equipos son de propiedad del laboratorio Decoroso Crespo de la Universidad Politécnica de Madrid. Una vez lograda la implementación e interacción entre las aplicaciones se han realizado pruebas de usabilidad con nueve estudiantes del Máster Universitario en Software y Sistemas de la Universidad Politécnica de Madrid. Cada uno ha respondido una serie de encuestas para poder obtener resultados sobre cuán usable es el prototipo, la experiencia del usuario y qué mejoras se podrían realizar sobre éste. En la parte final de este documento se presentan los resultados de las encuestas y se muestran las conclusiones y trabajo futuro.---ABSTRACT---Currently there are several devices that accept gestures on touch surfaces like phones, tablets, computers, etc. to which people quickly become accustomed to their use and accept them as necessary tools in their life. Similarly there are some applications that handle 3D environments and like televisions, holograms and allow capture gestures made with hands, body, and head. These techniques have been developed on a separated way but based on some research we may say that the are not many studies that combine touch with 3D applications handled by gestures in the air. This paper presents a prototype of the interaction of two issues of a 2D showing documents represented by spheres on a touch application developed in Unity that works on Android and allows communicating with the second application also developed in Unity that handles a 3D environment interaction of gestures made in air. After some attempts interaction was achieved by implementing communication sockets between the application on the Android device and 3D application that is hosted on a computer with windows 7, and gestures capturing in the air is done by the system Tracking Tools developed by the Optitrack company it captures movements with infrared cameras and markers on the fingers, which sends data to this application gestures, these equipment are owned by the Decoroso Crespo laboratory of the Polytechnic University of Madrid. Once achieved the interaction of applications has been conducted performance tests with ten students of the university master of the Universidad Politécnica de Madrid, each has answered a series of surveys to get results on how usable is the prototype, the user experience and that improvements could be made on this.