969 resultados para 16 mm film collections


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The main function of the mucociliary system is the removal of particles or substances that are potentially harmful to the respiratory tract. The tuning fork therapeutic for the purpose of bronchial hygiene has still not been described in the literature. The optimal vibration frequency to mobilize secretions is widely debated and varies between 3 and 25 Hz. It is expected that a tuning fork is able to generate vibrations in the thorax, facilitating bronchial hygiene. The aim of the present study is to develop tuning forks with different frequencies, for use in bronchopulmonary hygiene therapy. Methods: The first tuning fork was made with a fixed frequency of 25 Hz and it was recorded in the Brazilian institution of patent registration. This device generated a frequency of 25 Hz and had a weight of 521 g, with dimensions of 600 mm in total length. The device is characterized by a bottom end containing a transducer with a diameter of 62 mm and a thickness of 5/16 mm (8''), a rod removable 148 mm, fork length of 362 mm and an extension at the upper end of sinuous shape bilaterally.The tuning forks must be applied at an angle of 90° directly on the chest wall of the patient after pulmonary auscultation for location of secretions. The tuning fork is activated by squeezing the tips of the extensions together and releasing them in a sudden movement. Results: This study shows the result of the development of others three tuning forks of different dimensions to generate different frequencies. Each equipment reaches a fixed frequency preset of 12, 15 and 20 Hz measured by digital oscilloscope. Conclusions: The tuning fork models developed in this study generated different frequencies proposed by the scientific literature as effective in the mobilization of pulmonary secretions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The process of milling wood is widely used in operations such as planing and manufacturing frames . Machines like planers , desengrossadeiras , routers , moldureiras and machining centers employ the milling process for cutting wood . In this work the process of milling CNC machining center of Eucalyptus grandis was studied because this is very much used in furniture , but without consistent studies on this process . This work a CNC machining center brand TECH Z1 for analysis of surface quality ( Ra ) in relation to the variation of cutting speed and feed in concordant and discordant tangential milling and face milling was used . We used Eucalyptus grandis . Four forward speeds ( 3, 5 , 7, and 9 m / min ) for four shear rates ( 5,9; 8,4; 10,9 and 13,4 m/s ) were used. Was used for testing a cutter finishing top speed steel with helical teeth 16mm in diameter . 6 repetitions for each test condition were performed . From the results it was observed that the best results for roughness Vc = 10,9 m / s were obtained for the milling concordant with the forward speed Vf = 7 m / min. As for Vf = 5 m / min the best finish was achieved with Vc = 8,4 m /s in discordant for milling . The feedrate and cutting influenced the roughness . The senses of concordant and discordant and cut the top and the top had a significant difference in roughness

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this work was to investigate the s of daily prey concentration during the first 15 days of active feeding of Hoplias lacerdae larvae, and the juvenile size on the feed training. In the first phase, the larvae received five Artemia nauplii concentrations (P). In the second phase, the juveniles from each treatment were trained to accept formulated diet. Superior growth was related to higher initial daily prey concentrations (900 and 1100 nauplii larvae-1). During feed training, the growth tendency was similar to that verified in the first phase. The lowest values of specific growth rate (SGR) were registered after the introduction of the semi-moist diet used in the feed training. However, the values of SGR recovered along the experiment and similar rates were found among the treatments. Survival, mortality and cannibalism were similar in the different treatments at the end of both phases. It can be concluded that: the prey concentration affects growth of H. lacerdae during the first 15 days of active feeding, and feed training can be initialized with juveniles of about 16 mm of total length.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate the radiopacity of two conventional cements (Zinc Cement and Ketac Cem Easymix), one resin-modified glass ionomer cement (RelyX Luting 2) and six resin cements (Multilink, Bistite II DC, RelyX ARC, Fill Magic Dual Cement, Enforce and Panavia F) by digitization of images. Methods. Five disc-shaped specimens (10×1.0 mm) were made for each material, according to ISO 4049. After setting of the cements, radiographs were made using occlusal films and a graduated aluminum stepwedge varying from 1.0 to 16 mm in thickness. The radiographs were digitized, and the radiopacity of the cements was compared with the aluminum stepwedge using the software VIXWIN-2000. Data (mmAl) were submitted to one-way ANOVA and Tukey's test (=0.05). Results. The Zinc Cement was the most radiopaque material tested (<0.05). The resin cements presented higher radiopacity (<0.05) than the conventional (Ketac Cem Easymix) or resin-modified glass ionomer (RelyX Luting 2) cements, except for the Fill Magic Dual Cement and Enforce. The Multilink presented the highest radiopacity (<0.05) among the resin cements. Conclusion. The glass ionomer-based cements (Ketac Cem Easymix and RelyX Luting 2) and the resin cements (Fill Magic Dual Cement and Enforce) showed lower radiopacity values than the minimum recommended by the ISO standard.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate the effect of mechanical cycling and cementation strategies on the push-out bond strength between fiber posts and root dentin and the polymerization stresses produced using three resin cements. Materials and Methods: Eighty bovine mandibular teeth were sectioned to a length of 16 mm, prepared to 12 mm, and embedded in self-curing acrylic resin. The specimens were then distributed into 8 groups (n = 10): Gr1 - Scotchbond Multi Purpose + RelyX ARC; Gr2 - Scotchbond Multi Purpose + RelyX ARC + mechanical cycling; Gr3 - AdheSE + Multilink Automix; Gr4 - AdheSE + Multilink Automix + mechanical cycling; Gr5 - phosphoric acid + RelyX U100 (self-adhesive cement); Gr6 - phosphoric acid+ RelyX U100 + mechanical cycling; Gr7 - RelyX U100; Gr8 - RelyX U100 + mechanical cycling. The values obtained from the push-out bond strength test were submitted to two-way ANOVA and Tukey's test (p = 0.05), while the values obtained from the polymerization stress test were subjected to one-way ANOVA and Tukey's test (alpha = 0.05). Results: Mechanical cycling did not affect the bond strength values (p = 0.236), while cementation strategies affected the push-out bond strength (p < 0.001). Luting with RelyX U100 and Scotch Bond Multi Purpose + RelyX ARC yielded higher push-out bond strength values. The polymerization stress results were affected by the factor "cement" (p = 0.0104): the self-adhesive cement RelyX U100 exhibited the lowest values, RelyX ARC resulted in the highest values, while Multi link Automix presented values statistically similar to the other two cements. Conclusion: The self-adhesive cement appears to be a good alternative for luting fiber posts due to the high push-out bond strengths and lower polymerization stress values.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The study was conducted at the Research Laboratory of Hydraulic and Irrigation Group in the Rural Engineering Department, Technical University of Madrid (Universidad Politecnica de Madrid), Madrid, Spain. Water temperatures of 20, 30, 40 degrees C and system pressures often encountered in irrigation practices of 80, 90, 100, 110, 120, 130, 140, 150, 160, 170, 180, 190 and 200 k Pa were applied to determine the effects of different water temperatures and pressures on emitter discharge. Non-pressure compensating in-line emitter which has turbulent flow regime with a long-path (labyrinth), emitter discharge was 4 L h(-1) at system pressure of 100 kPa according to the manufacturer recommended, was used. Emitters were spaced 20 cm along the drip laterals with 16 mm diameter. Discharge equations and coefficients of variation related to temperatures of 20, 30 and 40 degrees C were obtained as q = 0.375H(0.51), q = 0.358H(0.52), q = 0.346H(0.53) and 2.68, 2.09, 3.65, respectively. Discharge of the emitter was affected by different system pressures and increased as potentially (R = 0993-0996). In general. the emitter discharge increased with increasing temperature. However, especially in the common system pressures of 90-120 k Pa, differences of obtained emitter discharges between the different water temperatures were not significant (1%).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: The aim of this study was to investigate the cardiometabolic effects of exercise training in ovariectomized hypertensive rats both submitted and not submitted to fructose overload. Methods: Spontaneously hypertensive ovariectomized rats were divided into sedentary and trained (THO) groups submitted to normal chow and sedentary and trained groups submitted to fructose overload (100 g/L in drinking water for 19 wk). Exercise training was performed on a treadmill (8 wk). Arterial pressure (AP) was directly recorded. Cardiovascular autonomic control was evaluated through pharmacological blockade (atropine and propranolol) and in the time and frequency domains by spectral analysis. Results: The THO group presented reduced AP (approximately 16 mm Hg) and enhanced cardiac vagal tonus (approximately 49%) and baroreflex sensitivity (approximately 43%) compared with the sedentary hypertensive ovariectomized group. Exercise training attenuated metabolic impairment, resting tachycardia, cardiac and vascular sympathetic increases, and baroreflex sensitivity decrease induced by fructose overload in hypertensive rats. However, the trained hypertensive ovariectomized group submitted to fructose overload presented higher AP (approximately 32 mm Hg), associated with baroreflex sensitivity (approximately 69%) and parasympathetic dysfunctions compared with the THO group. Conclusions: These data suggest that the metabolic disorders in hypertensive rats after ovarian hormone deprivation could blunt and/or attenuate some exercise training benefits.