960 resultados para viscoelastic capsule
Resumo:
The renal pseudocysts are accumulations of fluid unilateral or bilateral perirenal location, contained in a capsule without epithelium, a characteristic that distinguishes them from true renal cysts. The capsule itself may have originated in the renal capsule or a localized inflammatory reaction. The nature of the fluid can vary, but the presence of ooze found the most common, but they are also called pseudocysts accumulations of urine, blood and lymph. The most frequently observed clinical sign is abdominal distention. However these nonspecific signs may be related to chronic kidney disease and azotemia that may develop before or after the formation of this lesion. The abdominal ultrasound is less invasive and allows you to diagnose this change more easily, also allowing the collection of fluid guided percutaneous and submit it to cytological, biochemical and bacteriological in order to obtain information about its nature. This paper aims to describe a case of perinephric pseudocyst in a cat uriniferous, highlighting the contribution ultrasound as a diagnostic method complementary quick and noninvasive, allowing evaluation of the architecture of the renal parenchyma, differentiation of cortex and spinal cord as well as detect changes in size and shape of it, aiming for better planning in clinical surgery.
Resumo:
The yeast Cryptococcus neoformans is the etiologic agent of cryptococcosis, an infectious cosmopolitan disease that affects humans. Although rare, this disease is potentially fatal, especially for immunocompromised hosts. This pathogen is frequently isolated from excrements of pigeons and parrots, with many environmental sources such as birds, pigeon droppings, eucalyptus leaves, decaying trees, towers, churches and places of storage of grain (the port area). The isolation of this microorganism has been obtained also from the aquatic environment. The identification of environmental sources is needed to protect human health, especially susceptible populations such as immunocompromised. Therefore, this study investigated the presence of Cryptococcus neoformans in yeast isolates obtained from samples of sea water and sand from three regions of São Paulo: São Sebastião Channel, Santos and Ubatuba. Isolates were analyzed according to micro-and macroscopic characteristics and biochemical tests: microculture, urease, ink nankin, auxanograma, zymogram and phenol. We analyzed 199 isolates, 175 of which had features suggestive for Cryptococcus spp. in microculture. All these 175 isolates were sown in the Christensen urea middle to verify the production of urease and submitted to the technique nankin ink to visualize the capsule. Of these, only 24 were selected for the next test that was the auxanograma (assimilation of carbohydrate and nitrogen). Of the 24, 10 were tested in zymograms (fermented sugar), from which 5 were selected for the phenoloxidase test in medium containing dopamine. None of the 5 isolates tested had black or brown color characteristic of Cryptococcus neoformans. According to these tests, we arrived at 5 isolates identified to the genus Cryptococcus, but not the neoformans specie
Resumo:
Pós-graduação em Cirurgia Veterinária - FCAV
Resumo:
This graduation work done study of polyamide 6.6/composite carbon fibres, since its processing, characterization of the main properties. Besides the influence of temperature, UV radiation, salt spray and moisture on the mechanical and viscoelastic behavior. To achieve this goal, the first composite was processed from the heat compression molding using known variables of the process and using the empirical method to find the best value for other parameters. The method processing molding was chosen because it common in composites processing in order to evaluate the influence of crystallinity of the properties that influence the mechanical and viscoelastic behavior laminates. From the obtained laminate specimens were evaluated in weathering, such as: in hygrothermal chamber, UV, salt spray and thermal shock. In another step, the effect produced by these constraints were evaluated by optical microscopy, ultrasound, dynamic mechanical analysis and vibration tests. This project was conducted at the Department of Technology and Materials of UNESP in Guaratingueta, where all the equipment and techniques for the implementation of this project met available. After the tests proved the applicability of the composite polyamide 6.6/carbon fibers in aeronautical applications with resistance the main climatic influences
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Ciência Odontólogica - FOA
Resumo:
The aim of this study was to evaluate the rat subcutaneous tissue reaction to calcium hydroxide-based intracanal medicaments, UltraCal XS (calcium hydroxide, barium sulphate, aqueous matrix), Hydropast (calcium hydroxide, barium sulphate, and propyleneglycol), and Calen (Calcium hydroxide, zinc oxide, colophony, and polyethyleneglycol), used as a control. Methods. Forty-eight rats (Rattus Norvegicus Holtzman) were distributed in three groups: Calen, UltraCal XS, and Hydropast. Polyethylene tubes filled with one of the medicaments were implanted in the dorsal subcutaneous. After 7 and 30 days, the implants were removed and the specimens were fixed and embedded in paraffin. Morphological and quantitative analyses were carried out in the HE-stained sections. The numerical density of inflammatory cells in the capsule was evaluated and statistical analyses were performed (P>/0.05). Results. At 7 days, all materials induced an inflammatory reaction in the subcutaneous tissue adjacent to the implants. In all groups, a significant reduction in the number of inflammatory cells and giant cells was verified in the period of 30 days. Conclusion. These results indicate that the calcium hydroxide-based medicaments evaluated present biocompatibility similar to Calen.
Resumo:
The purpose of this study was to evaluate the macroscopy and microstructure of a double setting alpha-tricalcium phosphate bone cement sphere provided with interconnection channels (alpha-TCP-i), as well as the integration of the implant with the rabbits' orbital tissue, through macroscopic analysis and histopathology. The external and internal surfaces of the alpha-TCP-i were evaluated macroscopically and by electron microscopy. Twelve New Zealand rabbits received 12mm implants of alpha-TCP-i following enucleation of the left eye. The clinical assessment was undertaken daily during the first 15 days, followed by fortnightly assessment until the end of the study period. For the morphological analysis, exenteration was performed in 3 animals per experimental period (15, 45, 90 and 180 days). The external and internal surfaces of the implant appeared solid, smooth and compact, with six channels which interconnected centrally. The micro-architecture was characterized by the formation of columns of hexagonal crystals. No signs of infection, exposure, dehiscence of sutures or extrusion of the implant were noted in any of the animals during the entire period of the study. The morphological evaluation demonstrated the presence of a thin capsule around the implant, from whence appeared fibro-vascular projections, which penetrated it through the interconnecting channels. In the first days after the insertion of the implant, an intense inflammatory reaction was noted. At 180 days, however, there were no signs of inflammation. The alpha-tricalcium phosphate cement implant was well tolerated in this rabbit model and appeared to be relatively inert with some fibrovascular ingrowth through the large channels.
Resumo:
Pós-graduação em Ciência Odontólogica - FOA
Resumo:
A new species of Myxosporea, Henneguya aequidens sp. n. (Myxozoa: Myxobolidae), was described based on its ultrastructural features. This is a parasite of the freshwater fish Aequidens plagiozonatus, in the Peixe-boi River, Para, Brazil. This parasite was found in the gills, in the form of whitish ellipsoid cysts with mature spores inside them. The average spore body was 15 +/- 0.9 mu m in length (n = 30) and 6 +/- 0.8 mu m in width (n = 30), and the tail measured 27 +/- 0.5 mu m in length (n = 15). The spores showed typical features of the genus Henneguya with two valves of equal size and two symmetrical polar capsules of 3 +/- 0.3 mu m in length and 2 +/- 0.3 mu m in width. Each polar capsule had a polar filament forming a helix from the apical region to the polar caps, with four to six turns. Based on the ultrastructural differences in morphology of these spores, the location of the parasite, and its host specificity, this parasite was described as a new species.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The purpose of this work was to evaluate the biological compatibility of the Sealapex, Apexit, Sealer 26 and Ketac Endo endodontic cements. Polyethylene tubes containing these cements were implanted in the subcutaneous tissue of 40 (forty) rats. The animals were sacrificed after 14 and 90 days. A descriptive analysis of the reactions found in the connective tissue by contact with the cements was performed. The magnitude of inflammatory infiltrate, the presence and predominance of cell types and their distribution as to the filling material and reparative phenomena, such as fibroblastic and angioblastic proliferation and formation of fibrous capsules, were subjectively measured. After 90 days, all cements presented statistically significant reduction of the inflammatory reaction, presence of a fibrous tissue capsule in contact with the opening of the tubes containing the filling materials, and reduction of fibroblastic proliferation. Angioblastic proliferation decreased only for the Sealer 26 and Ketac Endo groups. All cements tested were either partially or totally phagocyted, and the mildest inflammatory response was found for the Sealer 26 group at both evaluation periods.
Resumo:
To compare the effects of dipyrone, meloxicam, and of the combination of these drugs on hemostasis in dogs. Prospective, blinded, randomized crossover study. Research laboratory at a veterinary teaching hospital. Six adult dogs. Animals received 4 intravenous treatments with 15-day washout intervals: control (physiological saline, 0.1 mL/kg), meloxicam (0.2 mg/kg), dipyrone (25 mg/kg), and dipyrone-meloxicam (25 and 0.2 mg/kg, respectively). A jugular catheter was placed for drug injection and for collecting samples for whole blood platelet aggregation (WBPA) and thromboelastometry assays at baseline, 1, 2, 3, 5, and 8 hours after treatment administration. The percent change from baseline of lag time and of the area under the curve (AUC) of impedance changes in response to collagen-induced platelet activation were recorded during WBPA. Thromboelastometry-derived parameters included clotting time, clot formation time, alpha-angle, and maximum clot firmness. The buccal mucosal bleeding time was evaluated by a blinded observer at baseline, 1, 3, and 5 hours after treatment injection. No significant changes in WBPA and thromboelastometry were recorded in the control treatment. Dipyrone significantly (P < 0.05) increased the lag time for 2 hours and decreased the AUC for 3 hours after injection. Meloxicam did not alter WBPA. Dipyrone-meloxicam significantly increased lag time for 2 hours and decreased the AUC for 5 hours after treatment injection. Experimental treatments did not differ from the control treatment for thromboelastometry and buccal mucosal bleeding time. While meloxicam does not alter hemostasis by the methods evaluated, dipyrone inhibits platelet aggregation for up to 3 hours. Meloxicam-dipyrone combination causes more prolonged inhibition of platelet function than dipyrone alone. Decreased platelet aggregation induced by dipyrone and dipyrone-meloxicam does not appear to impact the viscoelastic properties of the blood clot nor increase the risk of bleeding in dogs without preexisting hemostatic disorders.
Resumo:
To evaluate the efficacy of platelet-rich plasma regarding healing, pain and hemostasis after total knee arthroplasty, by means of a blinded randomized controlled and blinded clinical study. Forty patients who were going to undergo implantation of a total knee prosthesis were selected and randomized. In 20 of these patients, platelet-rich plasma was applied before the joint capsule was closed. The hemoglobin (mg/dL) and hematocrit (%) levels were assayed before the operation and 24 and 48 h afterwards. The Womac questionnaire and a verbal pain scale were applied and knee range of motion measurements were made up to the second postoperative month. The statistical analysis compared the results with the aim of determining whether there were any differences between the groups at each of the evaluation times. The hemoglobin (mg/dL) and hematocrit (%) measurements made before the operation and 24 and 48 h afterwards did not show any significant differences between the groups (p > 0.05). The Womac questionnaire and the range of motion measured before the operation and up to the first two months also did not show any statistical differences between the groups (p > 0.05). The pain evaluation using the verbal scale showed that there was an advantage for the group that received platelet-rich plasma, 24 h, 48 h, one week, three weeks and two months after the operation (p < 0.05). In the manner in which the platelet-rich plasma was used, it was not shown to be effective for reducing bleeding or improving knee function after arthroplasty, in comparison with the controls. There was an advantage on the postoperative verbal pain scale.
Resumo:
The biocompatibility of two dentin adhesives (Scotchbond MultiPurpose- 3M and Optibond Multi-Use - Kerr) was evaluated in rats subcutaneous connective tissue implants. Polyethylene tubes filled with the adhesives were surgically implanted into the dorsal subcutaneous tissues of rats. The tubes were left implanted for periods of 14, 30, 60 and 84 days, following wich the animais were killed and the implants, together with the surrounding tissue, were excised. The specimens were then fixed in 10 per cent formalin, sectioned serially and stained with hematoxylin and eosin and then, examined by light microscopy. After 14 and 30 days the tubes were surrounded by a mild to moderate inflammatory infiltration. After 60 and 84 days microscopic examination revealed the formation of a connective tissue capsule around each tube. The microscopic examination of the biopsy specimens allowed to conclude that: a) both dentin adhesives are considered biologically acceptable when placed in contact with rats subcutaneous connective tissue; b) in the observation period of 30 days there were moderate tissue reaction to the Optibond Multi-Use -light cure- (Kerr); c) after 60 and 84 days the use of both dentine adhesives did not interfere in the healing of the surrounding connective tissue