983 resultados para venous circulation
Resumo:
BACKGROUND: Omentin is a visceral fat-derived adipokine associated with endothelium-dependent vasodilation. Impaired endothelial function is a major cause of portal hypertension in liver cirrhosis. The aim was to assess associations of omentin with systemic markers of endothelial function, namely arginine and asymmetric dimethylarginine (ADMA) and complications of portal hypertension in liver cirrhosis. MATERIALS AND METHODS: Systemic omentin was measured by ELISA in portal venous serum (PVS), systemic venous serum (SVS) and hepatic venous serum (HVS) of 40 patients with liver cirrhosis and 10 liver-healthy controls. ADMA and arginine were determined in SVS of the patients by ELISA. RESULTS: Omentin is elevated in PVS and tends to be increased in SVS and HVS of patients with liver cirrhosis compared with controls. Omentin is principally expressed in visceral fat, and PVS omentin tends to be higher than SVS levels. Lower HVS than PVS omentin suggests that omentin may be partly removed from the circulation by the liver. Omentin in serum is not associated with stages of liver cirrhosis defined by CHILD-POUGH or MELD score and is not affected in patients with ascites. HVS omentin tends to be reduced in patients with large varices compared with patients without/with small varices. Arginine/ADMA ratio is reduced in patients with massive ascites but is not associated with variceal size. Further, Arginine/ADMA ratio does not correlate with omentin. CONCLUSION: Current data show that PVS omentin is increased in liver cirrhosis but is not associated with complications of portal hypertension
Resumo:
BACKGROUND AND PURPOSE The DRAGON score predicts functional outcome in the hyperacute phase of intravenous thrombolysis treatment of ischemic stroke patients. We aimed to validate the score in a large multicenter cohort in anterior and posterior circulation. METHODS Prospectively collected data of consecutive ischemic stroke patients who received intravenous thrombolysis in 12 stroke centers were merged (n=5471). We excluded patients lacking data necessary to calculate the score and patients with missing 3-month modified Rankin scale scores. The final cohort comprised 4519 eligible patients. We assessed the performance of the DRAGON score with area under the receiver operating characteristic curve in the whole cohort for both good (modified Rankin scale score, 0-2) and miserable (modified Rankin scale score, 5-6) outcomes. RESULTS Area under the receiver operating characteristic curve was 0.84 (0.82-0.85) for miserable outcome and 0.82 (0.80-0.83) for good outcome. Proportions of patients with good outcome were 96%, 93%, 78%, and 0% for 0 to 1, 2, 3, and 8 to 10 score points, respectively. Proportions of patients with miserable outcome were 0%, 2%, 4%, 89%, and 97% for 0 to 1, 2, 3, 8, and 9 to 10 points, respectively. When tested separately for anterior and posterior circulation, there was no difference in performance (P=0.55); areas under the receiver operating characteristic curve were 0.84 (0.83-0.86) and 0.82 (0.78-0.87), respectively. No sex-related difference in performance was observed (P=0.25). CONCLUSIONS The DRAGON score showed very good performance in the large merged cohort in both anterior and posterior circulation strokes. The DRAGON score provides rapid estimation of patient prognosis and supports clinical decision-making in the hyperacute phase of stroke care (eg, when invasive add-on strategies are considered).
Resumo:
Administration of cross-sex hormones to male-to-female transsexual subjects, usually oestrogens + often anti-androgens, such as cyproterone acetate, carries a risk of venous thromboembolism (VTE). VTE usually occurs in the first year of oestrogen administration. Ethinyl oestradiol, due to its chemical structure, was in 2003 identified as a major factor in the occurrence of VTE. Most clinics do not prescribe ethinyl oestradiol any longer, but people who take hormones without medical supervision use often oral contraceptives containing ethinyl oestradiol, many times in overdose. Cessation of use of ethinyl oestradiol and peri-operative thrombosis prophylaxis for surgery have reduced prevalence rate of VTE. Other oral oestrogens should not be overdosed, and transdermal oestrogen is to be preferred. Thrombosis prophylaxis for surgery is mandatory. It seems advisable to stop hormone use at least 2 weeks before major surgery, to be resumed only after 3 weeks following full mobilisation.
Resumo:
The coronary collateral circulation is an alternative source of blood supply to a myocardial area jeopardized by the failure of the stenotic or occluded vessel to provide enough blood flow to this region. Until recently, only qualitative or semiqualitative methods have been available for the assessment of the coronary collateral circulation in humans, such as the patient's history of walk-through angina pectoris, the registration of intracoronary ECG signs for myocardial ischaemia or angina pectoris during coronary occlusion, or coronary angiographic classification (score 0-3) of collaterals. Studies of coronary wedge pressure measurements distal of a balloon-occluded coronary artery and the recent advent of ultrathin pressure and Doppler angioplasty guidewires have made it possible to obtain pressure or flow velocity data in remote vascular areas and, thus, to calculate functional variables for coronary collateral flow. Those coronary occlusive pressure- and flow velocity-derived parameters express collateral flow as a fraction of antegrade coronary flow during vessel patency of the collateral-receiving vessel. They are both interchangeable, and they have been validated in comparison to 'traditional' methods and against each other. The possibility of accurately measuring coronary collateral flow indices in humans undergoing coronary balloon angioplasty opens areas of investigation of the pathogenesis, pathophysiology and therapeutic promotion of the collateral circulation previously reserved for exclusively experimental studies. The purpose of this article is to review several clinically available methods for the functional characterization of the coronary collateral circulation.
Resumo:
BACKGROUND The function of naturally existing internal mammary (IMA)-to-coronary artery bypasses and their quantitative effect on myocardial ischemia are unknown. METHODS AND RESULTS The primary end point of this study was collateral flow index (CFI) obtained during two 1-minute coronary artery balloon occlusions, the first with and the second without simultaneous distal IMA occlusion. The secondary study end point was the quantitatively determined intracoronary ECG ST-segment elevation. CFI is the ratio of simultaneously recorded mean coronary occlusive pressure divided by mean aortic pressure both subtracted by mean central venous pressure. A total of 180 pairs of CFI measurements were performed among 120 patients. With and without IMA occlusion, CFI was 0.110±0.074 and 0.096±0.072, respectively (P<0.0001). The difference of CFI obtained in the presence minus CFI obtained in the absence of IMA occlusion was highest and most consistently positive during left IMA with left anterior descending artery occlusion and during right IMA with right coronary artery occlusion (ipsilateral occlusions): 0.033±0.044 and 0.025±0.027, respectively. This CFI difference was absent during right IMA with left anterior descending artery occlusion and during left IMA with right coronary artery occlusion (contralateral occlusions): -0.007±0.034 and 0.001±0.023, respectively (P=0.0002 versus ipsilateral occlusions). The respective CFI differences during either IMA with left circumflex artery occlusion were inconsistently positive. Intracoronary ECG ST-segment elevations were significantly reduced during ipsilateral IMA occlusions but not during contralateral or left circumflex artery occlusions. CONCLUSION There is a functional, ischemia-reducing extracardiac coronary artery supply via ipsilateral but not via contralateral natural IMA bypasses. CLINICAL TRIAL REGISTRATION URL http://www.clinicaltrials.gov. Unique identifier: NCTO1676207.
Resumo:
BACKGROUND We aimed to assess whether elderly patients with acute venous thromboembolism (VTE) receive recommended initial processes of care and to identify predictors of process adherence. METHODS We prospectively studied in- and outpatients aged ≥65 years with acute symptomatic VTE in a multicenter cohort study from nine Swiss university- and non-university hospitals between September 2009 and March 2011. We systematically assessed whether initial processes of care, which are recommended by the 2008 American College of Chest Physicians guidelines, were performed in each patient. We used multivariable logistic models to identify patient factors independently associated with process adherence. RESULTS Our cohort comprised 950 patients (mean age 76 years). Of these, 86% (645/750) received parenteral anticoagulation for ≥5 days, 54% (405/750) had oral anticoagulation started on the first treatment day, and 37% (274/750) had an international normalized ratio (INR) ≥2 for ≥24 hours before parenteral anticoagulation was discontinued. Overall, 35% (53/153) of patients with cancer received low-molecular-weight heparin monotherapy and 72% (304/423) of patients with symptomatic deep vein thrombosis were prescribed compression stockings. In multivariate analyses, symptomatic pulmonary embolism, hospital-acquired VTE, and concomitant antiplatelet therapy were associated with a significantly lower anticoagulation-related process adherence. CONCLUSIONS Adherence to several recommended processes of care was suboptimal in elderly patients with VTE. Quality of care interventions should particularly focus on processes with low adherence, such as the prescription of continued low-molecular-weight heparin therapy in patients with cancer and the achievement of an INR ≥2 for ≥24 hours before parenteral anticoagulants are stopped.
Resumo:
We investigate the respective role of variations in subpolar deep water formation and Nordic Seas overflows for the decadal to multidecadal variability of the Atlantic meridional overturning circulation (AMOC). This is partly done by analysing long (order of 1000 years) control simulations with five coupled climate models. For all models, the maximum influence of variations in subpolar deep water formation is found at about 45° N, while the maximum influence of variations in Nordic Seas overflows is rather found at 55 to 60° N. Regarding the two overflow branches, the influence of variations in the Denmark Strait overflow is, for all models, substantially larger than that of variations in the overflow across the Iceland–Scotland Ridge. The latter might, however, be underestimated, as the models in general do not realistically simulate the flow path of the Iceland–Scotland overflow water south of the Iceland–Scotland Ridge. The influence of variations in subpolar deep water formation is, on multimodel average, larger than that of variations in the Denmark Strait overflow. This is true both at 45° N, where the maximum standard deviation of decadal to multidecadal AMOC variability is located for all but one model, and at the more classical latitude of 30° N. At 30° N, variations in subpolar deep water formation and Denmark Strait overflow explain, on multimodel average, about half and one-third respectively of the decadal to multidecadal AMOC variance. Apart from analysing multimodel control simulations, we have performed sensitivity experiments with one of the models, in which we suppress the variability of either subpolar deep water formation or Nordic Seas overflows. The sensitivity experiments indicate that variations in subpolar deep water formation and Nordic Seas overflows are not completely independent. We further conclude from these experiments that the decadal to multidecadal AMOC variability north of about 50° N is mainly related to variations in Nordic Seas overflows. At 45° N and south of this latitude, variations in both subpolar deep water formation and Nordic Seas overflows contribute to the AMOC variability, with neither of the processes being very dominant compared to the other.
Resumo:
This study provides a continuous lateglacial and Holocene record of diatom silica oxygen isotope changes (delta O-18(DIAT)) in a subalpine lake sediment sequence obtained from the Retezat Mts (Taul dintre Brazi, 1740 m a.s.l.). This through-flow, shallow, high-altitude lake with a surface area of only 0.4 ha has short water residence time and is predominantly fed by snowmelt and rainwater. Its delta O-18(DIAT) record principally reflects the oxygen isotope composition of the winter and spring precipitation, as diatom blooms occur mainly in the spring and early summer. Hence, changes in delta O-18(DIAT) are interpreted as seasonal scale changes: in the amount of winter precipitation. Low oxygen isotope values (27-28.5 parts per thousand) occurred during the lateglacial until 12,300 cal BP, followed by a sharp increase thereafter. In the Holocene delta O-18(DIAT) values ranged from 29 to 31 parts per thousand until 3200 cal BP, followed by generally lower values during the late Holocene (27-30 parts per thousand). Short-term decreases in the isotopic values were found between 10,140-9570, 9000-8500, 7800-7300, 6300-5800, 5500-5000 and at 8015, 4400, 4000 cal BP. After 3200 cal BP a decreasing trend was visible with the lowest values between 3100-2500 and after 2100 cal BP The general trend in the record suggests that contribution of winter precipitation was generally lower between 11,680 and 3200 cal BP, followed by increased contribution during the last millennia. The late Holocene decrease in delta O-18(DIAT) shows good agreement with the speleothem delta O-18, lake level and testate amoebae records from the Carpathian Mountains that also display gradual delta O-18 decrease and lake level/mire water table level rise after 3200 cal BR Strong positive correlation with North Atlantic circulation and solar activity proxies, such as the Austrian and Hungarian speleothem records, furthermore suggested that short-term increases in the isotopic ratios in the early and mid Holocene are likely connectable to high solar activity phases and high frequency of positive North Atlantic Oscillation indexes that may have resulted in decreased winter precipitation in this region.
Resumo:
Cerebrovascular diseases are significant causes of death and disability in humans. Improvements in diagnostic and therapeutic approaches strongly rely on adequate gyrencephalic, large animal models being demanded for translational research. Ovine stroke models may represent a promising approach but are currently limited by insufficient knowledge regarding the venous system of the cerebral angioarchitecture. The present study was intended to provide a comprehensive anatomical analysis of the intracranial venous system in sheep as a reliable basis for the interpretation of experimental results in such ovine models. We used corrosion casts as well as contrast-enhanced magnetic resonance venography to scrutinize blood drainage from the brain. This combined approach yielded detailed and, to some extent, novel findings. In particular, we provide evidence for chordae Willisii and lateral venous lacunae, and report on connections between the dorsal and ventral sinuses in this species. For the first time, we also describe venous confluences in the deep cerebral venous system and an 'anterior condylar confluent' as seen in humans. This report provides a detailed reference for the interpretation of venous diagnostic imaging findings in sheep, including an assessment of structure detectability by in vivo (imaging) versus ex vivo (corrosion cast) visualization methods. Moreover, it features a comprehensive interspecies-comparison of the venous cerebral angioarchitecture in man, rodents, canines and sheep as a relevant large animal model species, and describes possible implications for translational cerebrovascular research.
Primary prophylaxis for venous thromboembolism in ambulatory cancer patients receiving chemotherapy.
Resumo:
BACKGROUND Venous thromboembolism (VTE) often complicates the clinical course of cancer. The risk is further increased by chemotherapy, but the safety and efficacy of primary thromboprophylaxis in cancer patients treated with chemotherapy is uncertain. This is an update of a review first published in February 2012. OBJECTIVES To assess the efficacy and safety of primary thromboprophylaxis for VTE in ambulatory cancer patients receiving chemotherapy compared with placebo or no thromboprophylaxis. SEARCH METHODS For this update, the Cochrane Peripheral Vascular Diseases Group Trials Search Co-ordinator searched the Specialised Register (last searched May 2013), CENTRAL (2013, Issue 5), and clinical trials registries (up to June 2013). SELECTION CRITERIA Randomised controlled trials (RCTs) comparing any oral or parenteral anticoagulant or mechanical intervention to no intervention or placebo, or comparing two different anticoagulants. DATA COLLECTION AND ANALYSIS Data were extracted on methodological quality, patients, interventions, and outcomes including symptomatic VTE and major bleeding as the primary effectiveness and safety outcomes, respectively. MAIN RESULTS We identified 12 additional RCTs (6323 patients) in the updated search so that this update considered 21 trials with a total of 9861 patients, all evaluating pharmacological interventions and performed mainly in patients with advanced cancer. Overall, the risk of bias varied from low to high. One large trial of 3212 patients found a 64% (risk ratio (RR) 0.36, 95% confidence interval (CI) 0.22 to 0.60) reduction of symptomatic VTE with the ultra-low molecular weight heparin (uLMWH) semuloparin relative to placebo, with no apparent difference in major bleeding (RR 1.05, 95% CI 0.55 to 2.00). LMWH, when compared with inactive control, significantly reduced the incidence of symptomatic VTE (RR 0.53, 95% CI 0.38 to 0.75; no heterogeneity, Tau(2) = 0%) with similar rates of major bleeding events (RR 1.30, 95% CI 0.75 to 2.23). In patients with multiple myeloma, LMWH was associated with a significant reduction in symptomatic VTE when compared with the vitamin K antagonist warfarin (RR 0.33, 95% CI 0.14 to 0.83), while the difference between LMWH and aspirin was not statistically significant (RR 0.51, 95% CI 0.22 to 1.17). No major bleeding was observed in the patients treated with LMWH or warfarin and in less than 1% of those treated with aspirin. Only one study evaluated unfractionated heparin against inactive control and found an incidence of major bleeding of 1% in both study groups while not reporting on VTE. When compared with placebo, warfarin was associated with a statistically insignificant reduction of symptomatic VTE (RR 0.15, 95% CI 0.02 to 1.20). Antithrombin, evaluated in one study involving paediatric patients, had no significant effect on VTE nor major bleeding when compared with inactive control. The new oral factor Xa inhibitor apixaban was evaluated in a phase-II dose finding study that suggested a promising low rate of major bleeding (2.1% versus 3.3%) and symptomatic VTE (1.1% versus 10%) in comparison with placebo. AUTHORS' CONCLUSIONS In this update, we confirmed that primary thromboprophylaxis with LMWH significantly reduced the incidence of symptomatic VTE in ambulatory cancer patients treated with chemotherapy. In addition, the uLMWH semuloparin significantly reduced the incidence of symptomatic VTE. However, the broad confidence intervals around the estimates for major bleeding suggest caution in the use of anticoagulation and mandate additional studies to determine the risk to benefit ratio of anticoagulants in this setting. Despite the encouraging results of this review, routine prophylaxis in ambulatory cancer patients cannot be recommended before safety issues are adequately addressed.
Resumo:
BACKGROUND Cold atmospheric plasma (CAP, i.e. ionized air) is an innovating promising tool in reducing bacteria. OBJECTIVE We conducted the first clinical trial with the novel PlasmaDerm(®) VU-2010 device to assess safety and, as secondary endpoints, efficacy and applicability of 45 s/cm(2) cold atmospheric plasma as add-on therapy against chronic venous leg ulcers. METHODS From April 2011 to April 2012, 14 patients were randomized to receive standardized modern wound care (n = 7) or plasma in addition to standard care (n = 7) 3× per week for 8 weeks. The ulcer size was determined weekly (Visitrak(®) , photodocumentation). Bacterial load (bacterial swabs, contact agar plates) and pain during and between treatments (visual analogue scales) were assessed. Patients and doctors rated the applicability of plasma (questionnaires). RESULTS The plasma treatment was safe with 2 SAEs and 77 AEs approximately equally distributed among both groups (P = 0.77 and P = 1.0, Fisher's exact test). Two AEs probably related to plasma. Plasma treatment resulted in a significant reduction in lesional bacterial load (P = 0.04, Wilcoxon signed-rank test). A more than 50% ulcer size reduction was noted in 5/7 and 4/7 patients in the standard and plasma groups, respectively, and a greater size reduction occurred in the plasma group (plasma -5.3 cm(2) , standard: -3.4 cm(2) ) (non-significant, P = 0.42, log-rank test). The only ulcer that closed after 7 weeks received plasma. Patients in the plasma group quoted less pain compared to the control group. The plasma applicability was not rated inferior to standard wound care (P = 0.94, Wilcoxon-Mann-Whitney test). Physicians would recommend (P = 0.06, Wilcoxon-Mann-Whitney test) or repeat (P = 0.08, Wilcoxon-Mann-Whitney test) plasma treatment by trend. CONCLUSION Cold atmospheric plasma displays favourable antibacterial effects. We demonstrated that plasma treatment with the PlasmaDerm(®) VU-2010 device is safe and effective in patients with chronic venous leg ulcers. Thus, larger controlled trials and the development of devices with larger application surfaces are warranted.
Resumo:
BACKGROUND Polypharmacy, defined as the concomitant use of multiple medications, is very common in the elderly and may trigger drug-drug interactions and increase the risk of falls in patients receiving vitamin K antagonists. OBJECTIVE To examine whether polypharmacy increases the risk of bleeding in elderly patients who receive vitamin K antagonists for acute venous thromboembolism (VTE). DESIGN We used a prospective cohort study. PARTICIPANTS In a multicenter Swiss cohort, we studied 830 patients aged ≥ 65 years with VTE. MAIN MEASURES We defined polypharmacy as the prescription of more than four different drugs. We assessed the association between polypharmacy and the time to a first major and clinically relevant non-major bleeding, accounting for the competing risk of death. We adjusted for known bleeding risk factors (age, gender, pulmonary embolism, active cancer, arterial hypertension, cardiac disease, cerebrovascular disease, chronic liver and renal disease, diabetes mellitus, history of major bleeding, recent surgery, anemia, thrombocytopenia) and periods of vitamin K antagonist treatment as a time-varying covariate. KEY RESULTS Overall, 413 (49.8 %) patients had polypharmacy. The mean follow-up duration was 17.8 months. Patients with polypharmacy had a significantly higher incidence of major (9.0 vs. 4.1 events/100 patient-years; incidence rate ratio [IRR] 2.18, 95 % confidence interval [CI] 1.32-3.68) and clinically relevant non-major bleeding (14.8 vs. 8.0 events/100 patient-years; IRR 1.85, 95 % CI 1.27-2.71) than patients without polypharmacy. After adjustment, polypharmacy was significantly associated with major (sub-hazard ratio [SHR] 1.83, 95 % CI 1.03-3.25) and clinically relevant non-major bleeding (SHR 1.60, 95 % CI 1.06-2.42). CONCLUSIONS Polypharmacy is associated with an increased risk of both major and clinically relevant non-major bleeding in elderly patients receiving vitamin K antagonists for VTE.
Resumo:
OBJECTIVE Whether or not a high risk of falls increases the risk of bleeding in patients receiving anticoagulants remains a matter of debate. METHODS We conducted a prospective cohort study involving 991 patients ≥ 65 years of age who received anticoagulants for acute venous thromboembolism (VTE) at nine Swiss hospitals between September 2009 and September 2012. The study outcomes were as follows: the time to a first major episode of bleeding; and clinically relevant nonmajor bleeding. We determined the associations between the risk of falls and the time to a first episode of bleeding using competing risk regression, accounting for death as a competing event. We adjusted for known bleeding risk factors and anticoagulation as a time-varying covariate. RESULTS Four hundred fifty-eight of 991 patients (46%) were at high risk of falls. The mean duration of follow-up was 16.7 months. Patients at high risk of falls had a higher incidence of major bleeding (9.6 vs. 6.6 events/100 patient-years; P = 0.05) and a significantly higher incidence of clinically relevant nonmajor bleeding (16.7 vs. 8.3 events/100 patient-years; P < 0.001) than patients at low risk of falls. After adjustment, a high risk of falls was associated with clinically relevant nonmajor bleeding [subhazard ratio (SHR) = 1.74, 95% confidence interval (CI) = 1.23-2.46], but not with major bleeding (SHR = 1.24, 95% CI = 0.83-1.86). CONCLUSION In elderly patients who receive anticoagulants because of VTE, a high risk of falls is significantly associated with clinically relevant nonmajor bleeding, but not with major bleeding. Whether or not a high risk of falls is a reason against providing anticoagulation beyond 3 months should be based on patient preferences and the risk of VTE recurrence.
Resumo:
OBJECTIVES The purpose of this study was to investigate the survival effects of inferior vena cava filters in patients with venous thromboembolism (VTE) who had a significant bleeding risk. BACKGROUND The effectiveness of inferior vena cava filter use among patients with acute symptomatic VTE and known significant bleeding risk remains unclear. METHODS In this prospective cohort study of patients with acute VTE identified from the RIETE (Computerized Registry of Patients With Venous Thromboembolism), we assessed the association between inferior vena cava filter insertion for known significant bleeding risk and the outcomes of all-cause mortality, pulmonary embolism (PE)-related mortality, and VTE rates through 30 days after the initiation of VTE treatment. Propensity score matching was used to adjust for the likelihood of receiving a filter. RESULTS Of the 40,142 eligible patients who had acute symptomatic VTE, 371 underwent filter placement because of known significant bleeding risk. A total of 344 patients treated with a filter were matched with 344 patients treated without a filter. Propensity score-matched pairs showed a nonsignificant trend toward lower risk of all-cause death for filter insertion compared with no insertion (6.6% vs. 10.2%; p = 0.12). The risk-adjusted PE-related mortality rate was lower for filter insertion than no insertion (1.7% vs. 4.9%; p = 0.03). Risk-adjusted recurrent VTE rates were higher for filter insertion than for no insertion (6.1% vs. 0.6%; p < 0.001). CONCLUSIONS In patients presenting with VTE and with a significant bleeding risk, inferior vena cava filter insertion compared with anticoagulant therapy was associated with a lower risk of PE-related death and a higher risk of recurrent VTE. However, study design limitations do not imply a causal relationship between filter insertion and outcome.