942 resultados para ultrasound guided nerveblock
Resumo:
OBJECTIVES This study was conducted to determine if an additional procedural endpoint of unexcitability (UE) to pacing along the ablation line reduces recurrence of atrial fibrillation (AF) or atrial tachycardia (AT) after radiofrequency catheter ablation. BACKGROUND AF/AT recurrence is common after pulmonary vein isolation (PVI). METHODS We included 102 patients from 2 centers (age 63 ± 10 years; 33 women; left atrium 38 ± 7 mm; left ventricular ejection fraction 61 ± 6%) with symptomatic paroxysmal AF. A 3-dimensional mapping system and circumferential mapping catheter were used in all patients for PVI. In group 1 (n = 50), the procedural endpoint was bidirectional block across the ablation line. In group 2 (n = 52), additional UE to bipolar pacing at an output of 10 mA and 2-ms pulse width was required. The primary endpoint was freedom from any AF/AT (>30 s) after discontinuation of antiarrhythmic drugs. RESULTS Procedural endpoints were successfully achieved in all patients. Procedure duration was significantly longer in group 2 (185 ± 58 min vs. 139 ± 57 min; p < 0.001); however, fluoroscopy times were not different (23 ± 9 min vs. 23 ± 9 min; p = 0.49). After a follow-up of 12 months in all patients, 26 patients (52%) in group 1 versus 43 (82.7%) in group 2 were free from any AF/AT (p = 0.001) after a single procedure. No major complications occurred. CONCLUSIONS The use of pacing to ensure UE along the PVI line markedly improved near-term single-procedure success, compared with demonstration of bidirectional block alone. This additional endpoint significantly improved patient outcomes after PVI. (Unexcitability Along the Ablation as an Endpoint for Atrial Fibrillation Ablation; NCT01724437).
Resumo:
Ultrasound (US) has become a useful tool in the detection of early disease, differential diagnosis, guidance of treatment decisions and treatment monitoring of rheumatoid arthritis (RA). In 2008, the Swiss Sonography in Arthritis and Rheumatism (SONAR) group was established to promote the use of US in inflammatory arthritis in clinical practice. A scoring system was developed and taught to a large number of Swiss rheumatologists who already contributed to the Swiss Clinical Quality Management (SCQM) database, a national patient register. This paper intends to give a Swiss consensus about best clinical practice recommendations for the use of US in RA on the basis of the current literature knowledge and experience with the Swiss SONAR score. Literature research was performed to collect data on current evidence. The results were discussed among specialists of the Swiss university centres and private practice, following a structured procedure. Musculoskelatal US was found to be very helpful in establishing the diagnosis and monitoring the evolution of RA, and to be a reliable tool if used by experienced examiners. It influences treatment decisions such as continuing, intensifying or stepping down therapy. The definite modalities of integrating US into the diagnosis and monitoring of RA treatments will be defined within a few years. There are, however, strong arguments to use US findings as of today in daily clinical care. Some practical recommendations about the use of US in RA, focusing on the diagnosis and the use of the SONAR score, are proposed.
Resumo:
Purpose: Unilateral or bilateral axillary masses in children are often of clinical concern for malignancies. Our review illustrates a normal variant of the axilla mimicking clinically an axillary mass. Methods and Materials: Systematic review of our PACS and RIS with the keyword “axilla” and the modality “ultrasound” in children under 16 years of age from 1.12.2009 until 30.11.2012. 19 axillary ultrasound examinations in 16 patients (7m/9f, age 3 months to 15 years) were included. One patient was examined 2 and one patient 3 times. In 6 patients a prominent muscle was noted overlying the humeral head in an abducted position. The muscle diameter was measured in cm and compared with the contralateral side. In one patient photographs of the axilla were available. Results: In 16 examinations a lymphadenopathy (n=5), abscess formation (n=5), seroma or hematoma (n=1) or lymphangioma (n=1) and no diagnosis (n=1) was found. In 4 patients (25%) a unilateral muscle variant and in 2 patients a bilateral muscle variant (axillary arch muscle) was noted. In one patient a duplication of the muscle was found. In 4 patients the muscle was larger than the contralateral side. Conclusion: An axillary mass in children without other clinical complaints may be related to a normal variant, the axillary arch muscle. Ultrasound is the first modality of choice if imaging is required. Radiologists should be aware of this normal variant since no other workup is necessary in asymptomatic children.
Resumo:
The study investigated the influence of double-pulse transcranial magnetic stimulation (dTMS) on memory-guided saccade triggering. Double pulses with interstimulus intervals (ISIs) of 35, 50, 65 or 80 ms were applied over the right frontal eye field (FEF) and as control over the occipital cortex. A significant dTMS effect was found exclusively for contralateral saccades; latency of memory-guided saccades was reduced after FEF stimulation with an ISI of 50 ms compared to latency without stimulation. This effect proved to be specific for the ISI of 50 ms over the FEF because control stimulation with the same ISI over the occipital cortex had no significant effect on latency of memory-guided saccades. The results of our study showed that, by using an appropriate ISI, dTMS is able to facilitate contralateral saccade triggering by stimulating the FEF. This suggests that TMS interferes specifically with saccade triggering mechanisms, probably by acting on presaccadic neurons of the FEF.
Resumo:
HYPOTHESIS A previously developed image-guided robot system can safely drill a tunnel from the lateral mastoid surface, through the facial recess, to the middle ear, as a viable alternative to conventional mastoidectomy for cochlear electrode insertion. BACKGROUND Direct cochlear access (DCA) provides a minimally invasive tunnel from the lateral surface of the mastoid through the facial recess to the middle ear for cochlear electrode insertion. A safe and effective tunnel drilled through the narrow facial recess requires a highly accurate image-guided surgical system. Previous attempts have relied on patient-specific templates and robotic systems to guide drilling tools. In this study, we report on improvements made to an image-guided surgical robot system developed specifically for this purpose and the resulting accuracy achieved in vitro. MATERIALS AND METHODS The proposed image-guided robotic DCA procedure was carried out bilaterally on 4 whole head cadaver specimens. Specimens were implanted with titanium fiducial markers and imaged with cone-beam CT. A preoperative plan was created using a custom software package wherein relevant anatomical structures of the facial recess were segmented, and a drill trajectory targeting the round window was defined. Patient-to-image registration was performed with the custom robot system to reference the preoperative plan, and the DCA tunnel was drilled in 3 stages with progressively longer drill bits. The position of the drilled tunnel was defined as a line fitted to a point cloud of the segmented tunnel using principle component analysis (PCA function in MatLab). The accuracy of the DCA was then assessed by coregistering preoperative and postoperative image data and measuring the deviation of the drilled tunnel from the plan. The final step of electrode insertion was also performed through the DCA tunnel after manual removal of the promontory through the external auditory canal. RESULTS Drilling error was defined as the lateral deviation of the tool in the plane perpendicular to the drill axis (excluding depth error). Errors of 0.08 ± 0.05 mm and 0.15 ± 0.08 mm were measured on the lateral mastoid surface and at the target on the round window, respectively (n =8). Full electrode insertion was possible for 7 cases. In 1 case, the electrode was partially inserted with 1 contact pair external to the cochlea. CONCLUSION The purpose-built robot system was able to perform a safe and reliable DCA for cochlear implantation. The workflow implemented in this study mimics the envisioned clinical procedure showing the feasibility of future clinical implementation.
Resumo:
Internet-delivered self-help with minimal therapist guidance has shown promising results for a number of diagnoses. Most of the evidence comes from studies evaluating standardized disorder-specific treatments. A recent development in the field includes transdiagnostic and tailored Internet-based treatments that address comorbid symptoms and a broader range of patients. This study evaluated an Internet-based tailored guided self-help treatment, which targeted symptoms of social anxiety disorder, panic disorder with or without agoraphobia, and generalized anxiety disorder. The tailored treatment was compared both with standardized disorder-specific Internet-based treatment and with a wait-list control group. Both active treatment conditions were based on cognitive-behavioral therapy and lasted for 8 weeks. A total of 132 individuals meeting diagnostic criteria for at least one of the anxiety disorders were randomly assigned to 1 of the 3 conditions. Both treatment groups showed significant symptom reductions as compared with the wait-list control group on primary disorder-unspecific measures of anxiety, depression, and general symptomatology and on secondary anxiety disorder-specific measures. Based on the intention-to-treat sample, mean between-group effect sizes were d = 0.80 for the tailored treatment and d = 0.82 for the standardized treatment, versus wait-list controls. Treatment gains were maintained at 6-month follow-up. No differences were found between the 2 active treatment conditions on any of the measures, including a telephone-administered diagnostic interview conducted at posttreatment. The findings suggest that both Internet-based tailored guided self-help treatments and Internet-based standardized treatments are promising treatment options for several anxiety disorders
Resumo:
BACKGROUND: Tumor bed stereotactic radiosurgery (SRS) after resection of brain metastases is a new strategy to delay or avoid whole-brain irradiation (WBRT) and its associated toxicities. This retrospective study analyzes results of frameless image-guided linear accelerator (LINAC)-based SRS and stereotactic hypofractionated radiotherapy (SHRT) as adjuvant treatment without WBRT. MATERIALS AND METHODS: Between March 2009 and February 2012, 44 resection cavities in 42 patients were treated with SRS (23 cavities) or SHRT (21 cavities). All treatments were delivered using a stereotactic LINAC. All cavities were expanded by ≥ 2 mm in all directions to create the clinical target volume (CTV). RESULTS: The median planning target volume (PTV) for SRS was 11.1 cm(3). The median dose prescribed to the PTV margin for SRS was 17 Gy. Median PTV for SHRT was 22.3 cm(3). The fractionation schemes applied were: 4 fractions of 6 Gy (5 patients), 6 fractions of 4 Gy (6 patients) and 10 fractions of 4 Gy (10 patients). Median follow-up was 9.6 months. Local control (LC) rates after 6 and 12 months were 91 and 77 %, respectively. No statistically significant differences in LC rates between SRS and SHRT treatments were observed. Distant brain control (DBC) rates at 6 and 12 months were 61 and 33 %, respectively. Overall survival (OS) at 6 and 12 months was 87 and 63.5 %, respectively, with a median OS of 15.9 months. One patient treated by SRS showed symptoms of radionecrosis, which was confirmed histologically. CONCLUSION: Frameless image-guided LINAC-based adjuvant SRS and SHRT are effective and well tolerated local treatment strategies after resection of brain metastases in patients with oligometastatic disease.
Resumo:
AIM To investigate age- and gender-related differences in non-culprit versus culprit coronary vessels assessed with virtual histology intravascular ultrasound (VH-IVUS). METHODS In 390 patients referred for coronary angiography to a single center (Luzerner Kantonsspital, Switzerland) between May 2007 and January 2011, 691 proximal vessel segments in left anterior descending, circumflex and/or right coronary arteries were imaged by VH-IVUS. Plaque burden and plaque composition (fibrous, fibro-fatty, necrotic core and dense calcium volumes) were analyzed in 3 age tertiles, according to gender and separated for vessels containing non-culprit or culprit lesions. To classify as vessel containing a culprit lesion, the patient had to present with an acute coronary syndrome, and the VH-IVUS had to be performed in a vessel segment containing the culprit lesion according to conventional coronary angiography. RESULTS In non-culprit vessels the plaque burden increased significantly with aging (in men from 37% ± 12% in the lowest to 46% ± 10% in the highest age tertile, P < 0.001; in women from 30% ± 9% to 40% ± 11%, P < 0.001); men had higher plaque burden than women at any age (P < 0.001 for each of the 3 age tertiles). In culprit vessels of the lowest age tertile, plaque burden was significantly higher than that in non-culprit vessels (in men 48% ± 6%, P < 0.001 as compared to non-culprit vessels; in women 44% ± 18%, P = 0.004 as compared to non-culprit vessels). Plaque burden of culprit vessels did not significantly change during aging (plaque burden in men of the highest age tertile 51% ± 9%, P = 0.523 as compared to lowest age tertile; in women of the highest age tertile 49% ± 8%, P = 0.449 as compared to lowest age tertile). In men, plaque morphology of culprit vessels became increasingly rupture-prone during aging (increasing percentages of necrotic core and dense calcium), whereas plaque morphology in non-culprit vessels was less rupture-prone and remained constant during aging. In women, necrotic core in non-culprit vessels was very low at young age, but increased during aging resulting in a plaque morphology that was very similar to men. Plaque morphology in culprit vessels of young women and men was similar. CONCLUSION This study provides evidence that age- and gender-related differences in plaque burden and plaque composition significantly depend on whether the vessel contained a non-culprit or culprit lesion.
Resumo:
BACKGROUND Stereotactic navigation technology can enhance guidance during surgery and enable the precise reproduction of planned surgical strategies. Currently, specific systems (such as the CAS-One system) are available for instrument guidance in open liver surgery. This study aims to evaluate the implementation of such a system for the targeting of hepatic tumors during robotic liver surgery. MATERIAL AND METHODS Optical tracking references were attached to one of the robotic instruments and to the robotic endoscopic camera. After instrument and video calibration and patient-to-image registration, a virtual model of the tracked instrument and the available three-dimensional images of the liver were displayed directly within the robotic console, superimposed onto the endoscopic video image. An additional superimposed targeting viewer allowed for the visualization of the target tumor, relative to the tip of the instrument, for an assessment of the distance between the tumor and the tool for the realization of safe resection margins. RESULTS Two cirrhotic patients underwent robotic navigated atypical hepatic resections for hepatocellular carcinoma. The augmented endoscopic view allowed for the definition of an accurate resection margin around the tumor. The overlay of reconstructed three-dimensional models was also used during parenchymal transection for the identification of vascular and biliary structures. Operative times were 240 min in the first case and 300 min in the second. There were no intraoperative complications. CONCLUSIONS The da Vinci Surgical System provided an excellent platform for image-guided liver surgery with a stable optic and instrumentation. Robotic image guidance might improve the surgeon's orientation during the operation and increase accuracy in tumor resection. Further developments of this technological combination are needed to deal with organ deformation during surgery.
Resumo:
PURPOSE Images from computed tomography (CT), combined with navigation systems, improve the outcomes of local thermal therapies that are dependent on accurate probe placement. Although the usage of CT is desired, its availability for time-consuming radiological interventions is limited. Alternatively, three-dimensional images from C-arm cone-beam CT (CBCT) can be used. The goal of this study was to evaluate the accuracy of navigated CBCT-guided needle punctures, controlled with CT scans. METHODS Five series of five navigated punctures were performed on a nonrigid phantom using a liver specific navigation system and CBCT volumetric dataset for planning and navigation. To mimic targets, five titanium screws were fixed to the phantom. Target positioning accuracy (TPECBCT) was computed from control CT scans and divided into lateral and longitudinal components. Additionally, CBCT-CT guidance accuracy was deducted by performing CBCT-to-CT image coregistration and measuring TPECBCT-CT from fused datasets. Image coregistration was evaluated using fiducial registration error (FRECBCT-CT) and target registration error (TRECBCT-CT). RESULTS Positioning accuracies in lateral directions pertaining to CBCT (TPECBCT = 2.1 ± 1.0 mm) were found to be better to those achieved from previous study using CT (TPECT = 2.3 ± 1.3 mm). Image coregistration error was 0.3 ± 0.1 mm, resulting in an average TRE of 2.1 ± 0.7 mm (N = 5 targets) and average Euclidean TPECBCT-CT of 3.1 ± 1.3 mm. CONCLUSIONS Stereotactic needle punctures might be planned and performed on volumetric CBCT images and controlled with multidetector CT with positioning accuracy higher or similar to those performed using CT scanners.
Resumo:
OBJECTIVE Angiographic C-arm CT may allow performing percutaneous stereotactic tumor ablations in the interventional radiology suite. Our purpose was to evaluate the accuracy of using C-arm CT for single and multimodality image fusions and to compare the targeting accuracy of liver lesions with the reference standard of MDCT. MATERIALS AND METHODS C-arm CT and MDCT scans were obtained of a nonrigid rapid prototyping liver phantom containing five 1-mm targets that were placed under skin-simulating deformable plastic foam. Target registration errors of image fusion were evaluated for single-modality and multimodality image fusions. A navigation system and stereotactic aiming device were used to evaluate target positioning errors on postinterventional scans with the needles in place fused with the C-arm CT or MDCT planning images. RESULTS Target registration error of the image fusion showed no significant difference (p > 0.05) between both modalities. In five series with a total of 25 punctures for each modality, the lateral target positioning error (i.e., the lateral distance between the needle tip and the planned trajectory) was similar for C-arm CT (mean [± SD], 1.6 ± 0.6 mm) and MDCT (1.82 ± .97 mm) (p = 0.33). CONCLUSION In a nonrigid liver phantom, angiographic C-arm CT may provide similar image fusion accuracy for comparison of intra- and postprocedure control images with the planning images and enables stereotactic targeting accuracy similar to that of MDCT.
Resumo:
Beginning with a brief historical background, the chapter then offers the reader a practical overview of established procedures using image-guided surgery (IGS) in otorhinolaryngology. American and European recommendations for the use of IGS already exist and will be critically discussed in the light that a skilled hand and detailed knowledge of the anatomy by an experienced surgeon cannot yet be replaced by technology alone. Finally, a selected sample of new trends of experimental applications of intraoperative imaging and image-guided therapy will be given.
Resumo:
Magnetic resonance temperature imaging (MRTI) is recognized as a noninvasive means to provide temperature imaging for guidance in thermal therapies. The most common method of estimating temperature changes in the body using MR is by measuring the water proton resonant frequency (PRF) shift. Calculation of the complex phase difference (CPD) is the method of choice for measuring the PRF indirectly since it facilitates temperature mapping with high spatiotemporal resolution. Chemical shift imaging (CSI) techniques can provide the PRF directly with high sensitivity to temperature changes while minimizing artifacts commonly seen in CPD techniques. However, CSI techniques are currently limited by poor spatiotemporal resolution. This research intends to develop and validate a CSI-based MRTI technique with intentional spectral undersampling which allows relaxed parameters to improve spatiotemporal resolution. An algorithm based on autoregressive moving average (ARMA) modeling is developed and validated to help overcome limitations of Fourier-based analysis allowing highly accurate and precise PRF estimates. From the determined acquisition parameters and ARMA modeling, robust maps of temperature using the k-means algorithm are generated and validated in laser treatments in ex vivo tissue. The use of non-PRF based measurements provided by the technique is also investigated to aid in the validation of thermal damage predicted by an Arrhenius rate dose model.
Resumo:
The purpose of this study was to determine the perception and knowledge of targeted ultrasound in women who screen positive for Down syndrome in the first or second trimester, and to assess the perceived detection rate of Down syndrome by targeted ultrasound in this population. While several studies have reported patient perceptions’ of routine ultrasound, no study has specifically examined knowledge regarding the targeted ultrasound and its role in detecting Down syndrome. A targeted ultrasound is a special ultrasound during the second trimester offered to women who may be at a higher-than-average risk of having a baby with some type of birth defect or complication. The purpose of the ultrasound is to evaluate the overall growth and development of the baby as well as screen for birth defects and genetic conditions. Women under the age of 35 referred for an abnormal first or second trimester maternal serum screen to several Houston area clinics were asked to complete a questionnaire to obtain demographic and ultrasound knowledge information as well as assess perceived detection rate of Down syndrome by ultrasound. Seventy-seven women completed the questionnaire and participated in the study. Our findings revealed that women have limited background knowledge about the targeted ultrasound and its role in detecting Down syndrome. These findings are consistent with other studies that have reported a lack of understanding about the purpose of ultrasound examinations. One factor that seems to increase background knowledge about the targeted ultrasound is individuals having a higher level of education. However, most participants regardless of race, education, income, and exposure to targeted ultrasound information did not know the capabilities of a targeted ultrasound. This study confirmed women lack background knowledge about the targeted ultrasound and do not know enough about the technology to form a perception regarding its ability to detect Down syndrome. Additional studies to identify appropriate education techniques are necessary to determine how to best inform our patient population about targeted ultrasound.
Resumo:
PURPOSE: To determine whether a 3-mm isotropic target margin adequately covers the prostate and seminal vesicles (SVs) during administration of an intensity-modulated radiation therapy (IMRT) treatment fraction, assuming that daily image-guided setup is performed just before each fraction. MATERIALS AND METHODS: In-room computed tomographic (CT) scans were acquired immediately before and after a daily treatment fraction in 46 patients with prostate cancer. An eight-field IMRT plan was designed using the pre-fraction CT with a 3-mm margin and subsequently recalculated on the post-fraction CT. For convenience of comparison, dose plans were scaled to full course of treatment (75.6 Gy). Dose coverage was assessed on the post-treatment CT image set. RESULTS: During one treatment fraction (21.4+/-5.5 min), there were reductions in the volumes of the prostate and SVs receiving the prescribed dose (median reduction 0.1% and 1.0%, respectively, p<0.001) and in the minimum dose to 0.1 cm(3) of their volumes (median reduction 0.5 and 1.5 Gy, p<0.001). Of the 46 patients, three patients' prostates and eight patients' SVs did not maintain dose coverage above 70 Gy. Rectal filling correlated with decreased percentage-volume of SV receiving 75.6, 70, and 60 Gy (p<0.02). CONCLUSIONS: The 3-mm intrafractional margin was adequate for prostate dose coverage. However, a significant subset of patients lost SV dose coverage. The rectal volume change significantly affected SV dose coverage. For advanced-stage prostate cancers, we recommend to use larger margins or improve organ immobilization (such as with a rectal balloon) to ensure SV coverage.