976 resultados para transitive calibration


Relevância:

10.00% 10.00%

Publicador:

Resumo:

H-2 and O-2 multiplex coherent anti-stokes Raman spectroscopy (CARS) employing a single dye laser has been explored to simultaneously determine the temperature and concentrations of H-2 and O-2 in a hydrogen-fueled supersonic combustor. Systematic calibrations were performed through a well-characterized H-2/air premixed flat-flame burner. In particular, temperature measurement was accomplished using the intensity ratio of the H-2 S(5) and S(6) rotational lines, whereas extraction of the H-2 and O-2 concentrations was obtained from the H-2 S(6) and O-2 Q-branch, respectively. Details of the calibration procedure and data reduction are discussed. Quantification of the supersonic mixing and combustion characteristics applying the present technique has been demonstrated to be feasible. The associated detection limits as well as possible improvements are also identified.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Theoretical predictions of the diameters of continuous ink-jets downstream of long nozzles are generalized to include the important cases of ink-jet fluids and shorter nozzles where the velocity profile at the nozzle exit is undeveloped (non-parabolic). Comparisons of the new predictions with experiments and simulations are made for fairly long nozzles with tapered profiles and short nozzles with conical profiles; experimental and simulated profiles are also compared downstream of the nozzle exit for both industrial and large scale ink-jet print heads. Precise measurements of the un-modulated jet diameters downstream of the nozzle exit can set really useful limits to the possible shapes of the flow profile right at the nozzle exit, and in particular allow some assessment of the axial velocity gradients and fluid shear rates at the nozzle exit where direct speed measurement is usually impractical. Simulations allow further study of the relaxation of the velocity profile downstream of the nozzle exit, and are reported for both un-modulated and modulated CIJ jetting. Implications of this work include speeding up CIJ simulations, absolute calibration of the applied CIJ system modulation, and the likely magnitude of dynamic surface tension effects on observed CIJ satellite speeds.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The viscometer presented in this paper is suit-able for measuring the viscosity of liquids in micro-litre quantities. It consists of a micro-flow experimental system with a thermostat. Using the measurements of the flow rates and pressure drops of a liquid passing through a microtube, the liquid's viscosity can be calculated from on Hagen-Poiseuille theory. After calibration, the viscometer was used to measure viscosities of deionized water and ethyl alcohol at temperatures ranging from 0 to 40 "C. For both test liquids, the relative deviation of the measured values from those quoted in the literature (obtained using other viscometers) was less than 2.6o/o. The relative uncertainty of the experimental system was reduced to +-l.8% using the relative measuring method. Due to the micro-scale of the test section, only a micro-litre quantity of liquid is needed for a test, this is a potential advantage for measurement of bio-liquid viscosities.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A moving-coil designed micro-mechanics tester, named as MicroUTM (universal testing machine), is in-house developed in this paper for micro-mechanics tests. The main component is a moving coil suspended in a uniform magnetic field through a set of springs. When a current passes through the coil, the electromagnetic force is proportional to the magnitude of the current, so the load can easily be measured by the current. The displacement is measured using a capacitive sensor. The load is calibrated using a Sartorius BP211D analytical balance, with a resolution/range of 0.01 mg/80 g or 0.1 mg/210 g. The displacement is calibrated using a HEIDENHAIN CT-6002 length gauge with an accuracy of +/- 0.1 mu m. The calibration results show that the load range is +/- 1 N and the displacement range is +/- 300 mu m. The noise levels of the load and displacement are 50 mu N and 150 nm, respectively. The nonlinearity of the load is only 0.2%. Several in-plane load tests of the MEMS micro-cantilever are performed using this tester. Experimental results, with excellent repeatability, demonstrate the reliability of the load measurement as well as the flexible function of this tester.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Demonstra que a calibragem do salário mínimo desde sua criação, em julho de 1940, resultou mais de arbitramento político que de circunstâncias econômicas. Objetiva confirmar que, apesar de ter causado injunções à política do salário mínimo em diversos momentos, o risco econômico nunca foi seu determinante. Detecta-se, porém, certo descolamento entre ciclos da economia e curvas do salário mínimo. A falta de sincronia entre solidez econômica e valorização do mínimo ou entre crise econômica e achatamento do piso pode evidenciar que há uma razão não meramente econômica a operar a calibragem do salário mínimo. Essa justificativa, sua natureza, sua conformação, é o principal objeto da investigação e pode dar pistas interessantes sobre a evolução da democracia brasileira.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this article, we analyze how to evaluate fishery resource management under “ecological uncertainty”. In this context, an efficient policy consists of applying a different exploitation rule depending on the state of the resource and we could say that the stock is always in transition, jumping from one steady state to another. First, we propose a method for calibrating the growth path of the resource such that observed dynamics of resource and captures are matched. Second, we apply the calibration procedure proposed in two different fishing grounds: the European Anchovy (Division VIII) and the Southern Stock of Hake. Our results show that the role played by uncertainty is essential for the conclusions. For European Anchovy fishery (Division VIII) we find, in contrast with Del Valle et al. (2001), that this is not an overexploited fishing ground. However, we show that the Southern Stock of Hake is in a dangerous situation. In both cases our results are in accordance with ICES advice.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Report of Opening Session (pdf 0.07 Mb) Report of Governing Council (pdf 0.2 Mb) Report of the Finance and Administration Committee (pdf 0.07 Mb) Reports of Science Board and Committees Science Board inter-sessional meeting (pdf 0.07 Mb) Science Board (pdf 0.1 Mb) Biological Oceanography Committee (pdf 0.2 Mb) Fishery Science Committee (pdf 0.04 Mb) Marine Environmental Quality Committee (pdf 0.06 Mb) MONITOR Technical Committee (pdf 0.05 Mb) Physical Oceanography and Climate Committee (pdf 0.06 Mb) Technical Committee on Data Exchange (pdf 0.04 Mb) Reports of Sections, Working and Study Groups Section on Ecology of harmful algal blooms in the North Pacific (pdf 0.03 Mb) Section on Carbon and Climate Working Group 18 on Mariculture in the 21st century - The intersection between ecology, socio-economics and production (pdf 0.06 Mb) Working Group 19 on Ecosystem-based management science and its application to the North Pacific (pdf 0.03 Mb) Reports of the Climate Change and Carrying Capacity Program Implementation Panel on the CCCC Program (pdf 0.04 Mb) CFAME Task Team (pdf 0.04 Mb) MODEL Task Team (pdf 0.04 Mb) Reports of Advisory Panels Advisory Panel on Iron Fertilization Experiment in the Subarctic Pacific Ocean (pdf 0.04 Mb) Advisory Panel on Marine Birds and Mammals (pdf 0.03 Mb) Advisory Panel on Micronekton Sampling Inter-Calibration experiment (pdf 0.05 Mb) Summary of Scientific Sessions and Workshops (pdf 0.2 Mb) Membership List (pdf 0.07 Mb) List of Participants (pdf 0.07 Mb) List of Acronyms (pdf 0.03 Mb)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Report of Opening Session (pdf 0.07 Mb) Report of Governing Council (pdf 0.2 Mb) Report of the Finance and Administration Committee (pdf 0.08 Mb) Reports of Science Board and Committees Science Board inter-sessional meeting (pdf 0.05 Mb) Science Board (pdf 0.1 Mb) Biological Oceanography Committee (pdf 0.1 Mb) Fishery Science Committee (pdf 0.04 Mb) Marine Environmental Quality Committee (pdf 0.04 Mb) Physical Oceanography and Climate Committee (pdf 0.04 Mb) Technical Committee on Data Exchange (pdf 0.04 Mb) Reports of Sections, Working and Study Groups Harmful Algal Blooms Section (pdf 0.03 Mb) Working Group 17 on Biogeochemical data integration and synthesis (pdf 0.03 Mb) Working Group 18 on Mariculture in the 21st century - The intersection between ecology, socio-economics and production (pdf 0.06 Mb) Study Group on Ecosystem-based management science and its application to the North Pacific (pdf 0.04 Mb) Reports of the Climate Change and Carrying Capacity Program Implementation Panel on the CCCC Program (pdf 0.04 Mb) BASS Task Team (pdf 0.04 Mb) CFAME Task Team (pdf 0.04 Mb) MODEL Task Team (pdf 0.04 Mb) MONITOR Task Team (pdf 0.03 Mb) REX Task Team (pdf 0.04 Mb) Reports of Advisory Panels Advisory Panel on Continuous Plankton Recorder Survey in the North Pacific (pdf 0.4 Mb) Advisory Panel on Iron Fertilization Experiment in the Subarctic Pacific Ocean (pdf 0.03 Mb) Advisory Panel on Marine Birds and Mammals (pdf 0.04 Mb) Advisory Panel on Micronekton Sampling Inter-Calibration experiment (pdf 0.04 Mb) Summary of Scientific Sessions and Workshops (pdf 0.2 Mb) Membership List (pdf 0.07 Mb) List of Participants (pdf 0.09 Mb) List of Acronyms (pdf 0.03 Mb)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

CHAP 1 - Introduction to the Guide CHAP 2 - Solution chemistry of carbon dioxide in sea water CHAP 3 - Quality assurance CHAP 4 - Recommended standard operating procedures (SOPs) SOP 1 - Water sampling for the parameters of the oceanic carbon dioxide system SOP 2 - Determination of total dissolved inorganic carbon in sea water SOP 3a - Determination of total alkalinity in sea water using a closed-cell titration SOP 3b - Determination of total alkalinity in sea water using an open-cell titration SOP 4 - Determination of p(CO2) in air that is in equilibrium with a discrete sample of sea water SOP 5 - Determination of p(CO2) in air that is in equilibrium with a continuous stream of sea water SOP 6a - Determination of the pH of sea water using a glass/reference electrode cell SOP 6b - Determination of the pH of sea water using the indicator dye m-cresol purple SOP 7 - Determination of dissolved organic carbon and total dissolved nitrogen in sea water SOP 7 en Español - Determinacion de carbono organico disuelto y nitrogeno total disuelto en agua de mar SOP 11 - Gravimetric calibration of the volume of a gas loop using water SOP 12 - Gravimetric calibration of volume delivered using water SOP 13 - Gravimetric calibration of volume contained using water SOP 14 - Procedure for preparing sodium carbonate solutions for the calibration of coulometric CT measurements SOP 21 - Applying air buoyancy corrections SOP 22 - Preparation of control charts SOP 23 - Statistical techniques used in quality assessment SOP 24 - Calculation of the fugacity of carbon dioxide in the pure gas or in air CHAP 5 - Physical and thermodynamic data Errata - to the hard copy of the Guide to best practices for ocean CO2 measurements

Relevância:

10.00% 10.00%

Publicador:

Resumo:

基于Oliver与Pharr方法的纳米压痕实验以其简单方便获得广泛的应用,但众多因素对压痕实验结果的影响范围并无明确的结论.其中压痕接触面积的确定是一个重要环节,该因素对实验结果,特别是小深度下的实验结果具有重要影响.仔细分析了Oliver与Pharr方法并进行了几种材料的纳米压痕实验,针对该方法在接触深度确定、不同深度范围下方法的适用性进行了说明.分析结果表明,对所有的材料使用统一的面积公式,只有在大压痕深度时才是适用的,而在小压痕深度时可能带来较大的误差.因此,应慎重使用由Oliver与Pharr方法得到的小压痕深度的硬度数据.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The concept of biosensor with imaging ellipsometry was proposed about ten years ago. It has become an automatic analysis technique for protein detection with merits of label-free, multi-protein analysis, and real-time analysis for protein interaction process, etc. Its principle, andrelated technique units, such as micro-array, micro-fluidic and bio-molecule interaction cell, sampling unit and calibration for quantitative detection as well as its applications in biomedicine field are presented here.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There is a clear need to develop fisheries independent methods to quantify individual sizes, density, and three dimensional characteristics of reef fish spawning aggregations for use in population assessments and to provide critical baseline data on reproductive life history of exploited populations. We designed, constructed, calibrated, and applied an underwater stereo-video system to estimate individual sizes and three dimensional (3D) positions of Nassau grouper (Epinephelus striatus) at a spawning aggregation site located on a reef promontory on the western edge of Little Cayman Island, Cayman Islands, BWI, on 23 January 2003. The system consists of two free-running camcorders mounted on a meter-long bar and supported by a SCUBA diver. Paired video “stills” were captured, and nose and tail of individual fish observed in the field of view of both cameras were digitized using image analysis software. Conversion of these two dimensional screen coordinates to 3D coordinates was achieved through a matrix inversion algorithm and calibration data. Our estimate of mean total length (58.5 cm, n = 29) was in close agreement with estimated lengths from a hydroacoustic survey and from direct measures of fish size using visual census techniques. We discovered a possible bias in length measures using the video method, most likely arising from some fish orientations that were not perpendicular with respect to the optical axis of the camera system. We observed 40 individuals occupying a volume of 33.3 m3, resulting in a concentration of 1.2 individuals m–3 with a mean (SD) nearest neighbor distance of 70.0 (29.7) cm. We promote the use of roving diver stereo-videography as a method to assess the size distribution, density, and 3D spatial structure of fish spawning aggregations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents the construction, mathematical modeling and testing of a scaled universal hydraulic Power Take-Off (PTO) device for Wave Energy Converters (WECs). A specific prototype and test bench were designed and built to carry out the tests. The results obtained from these tests were used to adjust an in-house mathematical model. The PTO was initially designed to be coupled to a scaled wave energy capture device with a low speed and high torque oscillating motion and high power fluctuations. Any Energy Capture Device (ECD) that fulfils these requirements can be coupled to this PTO, provided that its scale is adequately defined depending on the rated power of the full scale prototype. The initial calibration included estimation of the pressure drops in the different components, the pressurization time of the oil inside the hydraulic cylinders and the volumetric efficiency of the complete circuit. Since the overall efficiency measured during the tests ranged from 0.69 to 0.8 and the dynamic performance of the PTO was satisfactory, the results are really promising and it is believed that this solution might prove effective in real devices.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of self-contained, low-maintenance sensor systems installed on commercial vessels is becoming an important monitoring and scientific tool in many regions around the world. These systems integrate data from meteorological and water quality sensors with GPS data into a data stream that is automatically transferred from ship to shore. To begin linking some of this developing expertise, the Alliance for Coastal Technologies (ACT) and the European Coastal and Ocean Observing Technology (ECOOT) organized a workshop on this topic in Southampton, United Kingdom, October 10-12, 2006. The participants included technology users, technology developers, and shipping representatives. They collaborated to identify sensors currently employed on integrated systems, users of this data, limitations associated with these systems, and ways to overcome these limitations. The group also identified additional technologies that could be employed on future systems and examined whether standard architectures and data protocols for integrated systems should be established. Participants at the workshop defined 17 different parameters currently being measured by integrated systems. They identified that diverse user groups utilize information from these systems from resource management agencies, such as the Environmental Protection Agency (EPA), to local tourism groups and educational organizations. Among the limitations identified were instrument compatibility and interoperability, data quality control and quality assurance, and sensor calibration andlor maintenance frequency. Standardization of these integrated systems was viewed to be both advantageous and disadvantageous; while participants believed that standardization could be beneficial on many levels, they also felt that users may be hesitant to purchase a suite of instruments from a single manufacturer; and that a "plug and play" system including sensors from multiple manufactures may be difficult to achieve. A priority recommendation and conclusion for the general integrated sensor system community was to provide vessel operators with real-time access to relevant data (e.g., ambient temperature and salinity to increase efficiency of water treatment systems and meteorological data for increased vessel safety and operating efficiency) for broader system value. Simplified data displays are also required for education and public outreach/awareness. Other key recommendations were to encourage the use of integrated sensor packages within observing systems such as 100s and EuroGOOS, identify additional customers of sensor system data, and publish results of previous work in peer-reviewed journals to increase agency and scientific awareness and confidence in the technology. Priority recommendations and conclusions for ACT entailed highlighting the value of integrated sensor systems for vessels of opportunity through articles in the popular press, and marine science. [PDF contains 28 pages]

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A three day workshop on turbidity measurements was held at the Hawaii Institute of Marine Biology from August 3 1 to September 2, 2005. The workshop was attended by 30 participants from industry, coastal management agencies, and academic institutions. All groups recognized common issues regarding the definition of turbidity, limitations of consistent calibration, and the large variety of instrumentation that nominally measure "turbidity." The major recommendations, in order of importance for the coastal monitoring community are listed below: 1. The community of users in coastal ecosystems should tighten instrument design configurations to minimize inter-instrument variability, choosing a set of specifications that are best suited for coastal waters. The IS0 7027 design standard is not tight enough. Advice on these design criteria should be solicited through the ASTM as well as Federal and State regulatory agencies representing the majority of turbidity sensor end users. Parties interested in making turbidity measurements in coastal waters should develop design specifications for these water types rather than relying on design standards made for the analysis of drinking water. 2. The coastal observing groups should assemble a community database relating output of specific sensors to different environmental parameters, so that the entire community of users can benefit from shared information. This would include an unbiased, parallel study of different turbidity sensors, employing a variety of designs and configuration in the broadest range of coastal environments. 3. Turbidity should be used as a measure of relative change in water quality rather than an absolute measure of water quality. Thus, this is a recommendation for managers to develop their own local calibrations. See next recommendation. 4. If the end user specifically wants to use a turbidity sensor to measure a specific water quality parameter such as suspended particle concentration, then direct measurement of that water quality parameter is necessary to correlate with 'turbidity1 for a particular environment. These correlations, however, will be specific to the environment in which they are measured. This works because there are many environments in which water composition is relatively stable but varies in magnitude or concentration. (pdf contains 22 pages)