996 resultados para total hemocyte count
Resumo:
Several extraction procedures are described for the determination of exchangeable and fixed ammonium, nitrate + nitrite, total exchangeable nitrogen and total nitrogen in certified reference soils and petroleum reservoir rock samples by steam distillation and indophenol method. After improvement of the original distillation system, an increase in worker safety, a reduction in time consumption, a decrease of 73% in blank value and an analysis without ammonia loss, which could possibly occur, were achieved. The precision (RSD < 8%, n = 3) and the detection limit (9 mg kg-1 NH4+-N) are better than those of published procedures.
Resumo:
Engineering and pricing of large recovery boiler were studied in this work. Engineering was carried out with Anita 4.2 which is an engineering program of Andritz. Key initial values were chosen with previous studies. Primary target of this work was to find out the consequences that furnace dimensions and furnace screen vertical part has to boiler pricing. Boilers that were engineered had different rate of furnace width and depth and different heat transfer plate count. Boiler balances were invariable. Boilers with different vertical screen construction were also calculated. First variation was boiler with vertical screen up to furnace roof. Other variation was to connect vertical screen to Pre-boiler generating bank inlet tubes. Total prices were calculated to engineered boilers. Pricing was sort out to heat transfers, high pressure pipes, steel structures, auxiliary equipments and civil/structural costs. This study did not notice parts of the boiler which costs do not vary with the construction of the boiler. Heat transfers had the largest share of costs. Boiler building had the most significant differences between the boilers. Furnace screen had also significant role especially to costs of the boiler building.
Resumo:
In this work a fast method for the determination of the total sugar levels in samples of raw coffee was developed using the near infrared spectroscopy technique and multivariate regression. The sugar levels were initially obtained using gravimety as the reference method. Later on, the regression models were built from the near infrared spectra of the coffee samples. The original spectra were pre-treated according to the Kubelka-Munk transformation and multiplicative signal correction. The proposed analytical method made possible the direct determination of the total sugar levels in the samples with an error lower by 8% with respect to the conventional methodology.
Resumo:
Total Hg content in soils of Baixada Santista, affected by different sources of pollution, and Cardoso Island, which is almost free of anthropogenic activities, were determined by CVAAS. To explain the fate of Hg in the ecosystem, pH, Eh, AVS, Stotal and Total Organic Carbon were also obtained throughout the soil profiles. With the exception of two sampling sites the average content of Hg in samples obtained for Baixada Santista was 0.34 ± 0.20 mg kg-1, which was close to the average data at Cardoso Island (0.30 ± 0.21 mg kg-1). Both of them were below the limit established by CETESB - 0.50 mg kg-1.
Resumo:
Valtimotautiriskin arviointi verenpainepotilailla Valtimotaudit ovat yleisin kuolinsyy koko maailmassa. Väestön elintapojen muuttuminen ja ikääntyminen uhkaavat edelleen lisätä valtimotautien esiintyvyyttä. Kokemäenjokilaakson valtimotautien ehkäisyprojektin tavoitteena oli löytää 45–70-vuotiaasta väestöstä henkilöt, joilla on kohonnut riski sairastua valtimotauteihin. Kaksivaiheisen seulontamenetelmän avulla voitiin terveydenhoitajan antama elintapaneuvonta kohdistaa riskihenkilöihin ja rajoittaa lääkärin vastaanoton tarve niihin potilaisiin, jotka todennäköisesti hyötyvät ennaltaehkäisevästä lääkityksestä. Suomalainen tyypin 2 diabeteksen sairastumisriskin arviointikaavake ja hoitajan toteama kohonnut verenpaine osoittautuivat käytännöllisiksi menetelmiksi seuloa väestöstä riskihenkilöitä. Valtimotautien ehkäisyprojektissa Harjavallassa ja Kokemäellä todettiin verenpainetauti 1 106 henkilöllä, jotka eivät sairastaneet valtimotautia tai aiemmin todettua diabetesta. Heidän tutkimustulostensa avulla voidaan arvioida kohonneen verenpaineen vaikutusta sokeriaineenvaihduntaan ja verenpaineen aiheuttamiin kohde-elinvaurioihin. Sokeriaineenvaihdunnan häiriöt ovat verenpainetautia sairastavilla yleisempiä kuin väestössä muutoin. Käyttämällä metabolisen oireyhtymän kriteerejä sokerirasituskokeen suorittamisen edellytyksenä voidaan tutkimusten määrää vähentää kolmanneksella ja silti löytää lähes kaikki diabetesta tai sen esiastetta sairastavat verenpainepotilaat. Verenpainepotilaista etenkin metabolista oireyhtymää sairastavilla naisilla on suurentunut munuaisten vajaatoiminnan riski. Jos verenpainepotilaan munuaisten toimintaa arvioidaan pelkästään plasman kreatiniini -arvon perusteella, kolme neljästä munuaisten vajaatoimintaa potevasta jää toteamatta verrattuna laskennallisen glomerulusten suodattumisnopeuden määritykseen seulontamenetelmänä. Joka kolmannella verenpainetautia sairastavalla voidaan todeta alaraajavaltimoiden kovettumista; useammin niillä, joiden ylä- ja alaverenpaineen erotus, pulssipaine on yli 65 mmHg. Verenpainetauti on itsenäinen perifeerisen valtimotaudin vaaratekijä. Tutkimuksessa käytetty menetelmä nilkka-olkavarsipainesuhteen määrittämiseksi soveltunee hyvin perusterveydenhuollon käyttöön riskihenkilöiden löytämiseksi. Valtimotautien kokonaisriskin arviointimenetelmät tai uuden riskitekijän, herkän C-reaktiivisen proteiinin määritys eivät voi korvata kohde-elinvaurioiden mittaamista verenpainepotilaan valtimotautiriskin huolellisessa arvioinnissa.
Resumo:
The present work investigated the effect of coprecipitation-oxidant synthesis on the specific surface area of perovskite-type oxides LaBO3 (B= Mn, Ni, Fe) for total oxidation of ethanol. The perovskite-type oxides were characterized by X-ray diffraction, nitrogen adsorption (BET method), thermogravimetric analysis (TGA-DTA), TPR and X-ray photoelectron spectroscopy (XPS). Through method involving the coprecipitation-oxidant was possible to obtain catalysts with different BET specific surface areas, of 33-51 m²/g. The results of the catalytic test confirmed that all oxides investigated in this work have specific catalytic activity for total oxidation of ethanol, though the temperatures for total conversion change for each transition metal.
Resumo:
Ozonation tests with and without prior filtration by means of a 50 micron mesh cartridge filter were conducted with primary sanitary effluents. Filtration led to increased inactivation efficiencies with regard to total and thermotolerant coliforms but it did not seem to influence heterotrophic plate count (HPC) bacteria inactivation efficiencies significantly. Application of the Chick-Watson model to experimental data obtained in the situation of constant inactivation showed that the ozone dosage was more important to bacterial inactivation than the contact time with regard to the cases of thermotolerant coliform inactivation in filtered samples and HPC bacteria and total coliform inactivation in non-filtered samples.
Resumo:
Water treatment uses chlorine for disinfection causing formation of trihalomethanes. In this work, an electrolytic water pre-treatment was studied and applied to the water from a fountainhead. The action against microorganisms was evaluated using cast-iron and aluminum electrodes. Assays were made in laboratory using the electrolytic treatment. After 5 min of electrolysis the heterotrophic bacteria count was below 500 cfu/mL and complete elimination of total and fecal coliforms was observed. Using electrolytic treatment as a pretreatment of conventional tap water treatment is proposed.
Resumo:
Diffuse reflectance near-infrared (DR-NIR) spectroscopy associated with partial least squares (PLS) multivariate calibration is proposed for a direct, non-destructive, determination of total nitrogen in wheat leaves. The procedure was developed for an Analytical Instrumental Analysis course, carried out at the Institute of Chemistry of the State University of Campinas. The DR-NIR results are in good agreement with those obtained by the Kjeldhal standard procedure, with a relative error of less than ± 3% and the method may be used for teaching purposes as well as for routine analysis.
Resumo:
The high sensitivity and excellent timing accuracy of Geiger mode avalanche photodiodes makes them ideal sensors as pixel detectors for particle tracking in high energy physics experiments to be performed in future linear colliders. Nevertheless, it is well known that these sensors suffer from dark counts and afterpulsing noise, which induce false hits (indistinguishable from event detection) as well as an increase of the necessary area of the readout system. In this work, we present a comparison between APDs fabricated in a high voltage 0.35 µm and a high integration 0.13 µm commercially available CMOS technologies that has been performed to determine which of them best fits the particle collider requirements. In addition, a readout circuit that allows low noise operation is introduced. Experimental characterization of the proposed pixel is also presented in this work.
Resumo:
This work reports an alternative, fast and robust method, for the determination of total As, As(III) and As(V) by HG-AAS without the use of prereductants. The method is based on the different rates of arsine formation of the inorganic As species and the effect of As(III) in the signal obtained for total As. Groundwater and mineral spiked waters were used to sample preservation evaluation. The method was validated by the determination of As in SRM 1640 and used in the determination of total As and its inorganic species in groundwater samples collected from mines in the Iron Quadrangle - MG.
Resumo:
Different methods to determine total fat (TF) and fatty acids (FA), including trans fatty acids (TFA), in diverse foodstuffs were evaluated, incorporating gravimetric methods and gas chromatography with flame ionization detector (GC/FID), in accordance with a modified AOAC 996.06 method. Concentrations of TF and FA obtained through these different procedures diverged (p< 0.05) and TFA concentrations varied beyond 20 % of the reference values. The modified AOAC 996.06 method satisfied both accuracy and precision, was fast and employed small amounts of low toxicity solvents. Therefore, the results showed that this methodology is viable to be adopted in Brazil for nutritional labeling purposes.
Resumo:
Mercury distribution and geochemical support on the Continental Margin was evaluated at the Campos Basin, Rio de Janeiro state, Brazil. The average concentrations for all analyzed elements were, respectively, 20 ± 5 ng g-1 (Hg); 30 ± 14 mg g-1 (Al); 16 ± 6 mg g-1 (Fe), and 254 ± 83 µg g-1 (Mn). Silt and clay content, total carbonate and Hg, and organic carbon increased with depth. Finally, the relationship between Hg and silt clay showed significant positive correlation. Total Hg concentrations are the background level described primarily (~40 ng g-1).
Resumo:
Mercury is a toxic metal used in a variety of substances over the course history. One of its more dubious uses is in dental amalgam restorations. It is possible to measure very small concentrations of this metal in the urine of exposed subjects by the cold vapor atomic absorption technique. The present work features the validation as an essential tool to confirm the suitability of the analytical method chosen to accomplish such determination. An initial analysis will be carried out in order to evaluate the environmental and occupational levels of exposure to mercury in 39 members of the auxiliary dental staff at public consulting rooms in the city of Araguaína (TO).
Resumo:
Interlaboratorial comparison of the determination of hardness and chloride in water had been performed by 38 and 37 laboratories, respectively. In all cases the participating laboratories used its routine methods. Homogeneity and stability testing were performed on the samples sent to the laboratories. The codified results are graphically reported and compared to assigned value, determined by the consensus of the laboratories. Satisfactory results were obtained for 71 and 73% of the laboratories, considering hardness and chloride determination, respectively.