995 resultados para pure titanium


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mg-based metallic glass interpenetrating phase composites (IPCs) containing 30-70 vol% titanium was fabricated in this study. The effects of reinforced phase volume fraction and interspace on the mechanical properties were investigated systematically. With increasing the volume fraction of titanium, the fracture strength and strain increased up to 1860 MPa and 44%, respectively. The results showed that the critical volume fraction (around 40%) of Ti metal should be required for significantly improving plasticity of IPC. Decreasing the interspace of the titanium phase could lead to enhancement of yield and fracture strength. The deformation behavior and strengthening mechanisms were discussed in detail.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The fracture behavior of titanium open foam is characterized and the R-curves of crack propagation from pre-cracks are measured. The crack growth has been optically observed, the measured initiation toughness, JIC, has been analyzed and the effect of material morphology on the JIC is discussed. The fracture toughness was found to be dependent on the expanding crack bridging zone at the back of the crack tip. The compact tension specimens also have some plastic collapse along the ligaments and it has shown that the titanium foam with a higher relative density is tougher. The non-uniform stressing within the plastic zone at the crack tip and the plastic collapse of cell topology behind the tip was found to be the primary cause of the R-curve behavior in low relative density titanium foams.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The morphology of nanomaterials significantly affects their physical, chemical, and biological properties. In the present study, nano-hydroxyapatite coatings with different morphologies were produced on the surface of a titanium-niobium shape memory alloy via a hydrothermal process. The effect of the nano-hydroxyapatite coatings on the in vitro proliferation of SaOS-2 osteoblast-like cells was investigated. Factors including crystallinity, surface micro-roughness, and surface energy of the nano-hydroxyapatite coatings were discussed. Results show that in vitro proliferation of the osteoblast-like cells was significantly enhanced on the nano-hydroxyapatite-coated titanium-niobium alloy compared to the titanium-niobium alloy without coating. The cell numbers on the nano-hydroxyapatite-coated titanium-niobium alloy changed consistently with the surface energy of the hydroxyapatite coatings. This study suggests that surface energy as a characteristic parameter influencing the in vitro proliferation of osteoblast-like cells was predominant over the crystallinity and surface micro-roughness of the nano-hydroxyapatite coatings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new method was investigated to produce new multiscale fibrous nanocomposites comprised of titanium oxide (TiO2) nanofibers and silver (Ag) nanoparticles (NPs). The process involved electrospinning TiO2 precursor solution containing colloidal solution of Ag NPs, and organic solvent (dimethyl-n′n-formamide) to fabricate a porous, nonwoven, free-standing nanofiber mesh. Postprocess heating of the electrospun nanofibers entailed calcination in air environment at 500°C for 3 h. Microemulsion processing was used to generate NPs of Ag in a monodispersed distribution throughout the colloidal solution. X-ray diffraction data were consistent with the anatase phase of TiO2, while transmission electron microscopy and hydrogen desorption measurements revealed a very porous microstructure. It was demonstrated that NP colloidal stability is solvent dependent. It is anticipated that incorporation of metal particles in nanofibers will lead to enhanced photocurrent generation, when used in functional devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hydroxyapatite (HAp) is commonly used to coat titanium alloys (Ti–6Al–4V) for orthopedic implants. However, their poor adhesion strength and insufficient long-term stability limit their application. Novel sphene (CaTiSiO5) ceramics possess excellent chemical stability and cytocompatibility. The aim of this study is to use the novel sphene ceramics as coatings for Ti–6Al–4V. The sol–gel method was used to produce the coatings and the thermal properties, phase composition, microstructure, thickness, surface roughness and adhesion strength of sphene coatings were analyzed by differential thermal analysis–thermal gravity (DTA–TG), X-ray diffraction (XRD), scanning electron microscopy (SEM), atom force microscopy (AFM) and scratch test, respectively. DTA analysis confirmed that the temperature of the sphene phase formation is 875 °C and XRD analysis indicated pure sphene coatings were obtained. A uniform structure of the sphene coating was found across the Ti–6Al–4V surface, with a thickness and surface roughness of the coating of about 0.5–1 μm and 0.38 μm, respectively. Sphene-coated Ti–6Al–4V possessed a significantly improved adhesion strength compared to that for HAp coating and their chemical stability was evaluated by testing the profile element distribution and the dissolution kinetics of calcium (Ca) ions after soaking the sphene-coated Ti–6Al–4V in Tris–HCl solution. Sphene coatings had a significantly improved chemical stability compared to the HAp coatings. A layer of apatite formed on the sphene-coated Ti–6Al–4V after they were soaked in simulated body fluids (SBF). Our results indicate that sol–gel coating of novel sphene onto Ti–6Al–4V possessed improved adhesion strength and chemical stability, compared to HAp-coated Ti–6Al–4V prepared under the same conditions, suggesting their potential application as coatings for orthopedic implants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

pH-detachable poly(styrene) brushes formed on indium−tin oxide (ITO) glass substrates using metal complex chemistry and reversible addition−fragmentation chain transfer (RAFT) polymerization was described. These pH-detachable polymeric brushes were generated using both “graft-from” and “graft-to” methodologies. The methodologies involved either the surface self-assembly of catechol-functional RAFT agents (graft-from) or catechol-terminal polymer chains (graft-to) onto the ITO substrate via titanium−diol coordination. The stepwise functionalization of the ITO glass surfaces was characterized successfully using X-ray photoelectron spectroscopy (XPS) and contact angle measurement. Poly(styrene) brushes generated using the “graft-from” method were denser than those generated using the “graft-to” method, as exemplified by atom force microscopy (AFM) and quantified using cyclic voltammetry. Poly(styrene) brushes assembled using both methods could be detached easily by manipulating the pH of the brush environment. Cyclic voltammetry was utilized to calculate precisely the surface coverage of the RAFT functionality and polymeric brush density.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Similar and dissimilar butt joint welds comprising combinations of commercially pure grade 4 titanium (CP-Ti), Ti-6Al-4V (Ti-64) and Ti-5Al-5V-5Mo-3Cr (Ti-5553) were created using the electron beam process. The resultant welds were studied by means of metallography, optical microscopy, mechanical testing and scanning electron microscopy. Mechanical testing was performed on welded samples to study the joint integrity and fracture characteristics. A scanning electron microscope investigation was performed on the fracture surface to reveal their fracture modes. While all weldments were crack free and most weldments exhibited mechanical properties comparable to the base metal, negligible ductility was exhibited during tensile testing joints of Ti- 5553 welded to either Ti-64 or Ti-5553.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, analytical models of pure bending are developed to simulate a particular type of bend test and to determine possible errors arising from approximations used in analyzing experimental data. Analytical models proposed for steels include a theoretical solution of pure bending and a series of finite element models, based on the von Mises yield function, are subjected to different stress and strain conditions. The results show that for steel sheets the difference between measured and calculated results of the moment-curvature behaviour is small and the numerical results from the finite element models indicate that experimental results obtained from the test are acceptable in the range of the pure bending operation. Further for magnesium alloys, which exhibit unsymmetrical yielding, the algorithm of the yield function with a linear isotropic hardening model is implemented by programming a user subroutine in Abaqus for bending simulations of magnesium. The simulations using the proposed user subroutine extract better results than those using the von Mises yield function.