990 resultados para polymer actuators
Resumo:
Nonisothermal and isothermal melt crystallization kinetics of a novel aryl ether ketone polymer containing meta-phenylene linkages, PEKEKK (T/I), were studied by differential scanning calorimetry (DSC). The Avrami equation modified by Jeziorny and a new approach by combining the Avrami equation with the Ozawa equation could describe the nonisothermal crystallization. Isothermal crystallization could also be described by the Avrami equation. The activation energies were 187 and 159 kJ/mol for nonisothermal and isothermal crystallization, respectively. Using the Hoffman-Weeks method, the equilibrium melting point T-m(o) was estimated as 353 degrees C. From the spherulitic growth equation proposed by Hoffman and Lauritzen, the nucleation parameter K-g of the isothermal melt crystallization was estimated as 5.49 x 10(5) K-2. The crystallization characteristics of PEKEKK (T/I) were compared with those of all-para PEKEKK. The differences were explained by differences in the chain flexibility of the two polymers.
Resumo:
Monte Carlo method has been applied to investigate the kinetic of grafting reaction in free radical copolymerization. The simulation is quits in agreement with that of theoretical and experimental results. It proves that the Monte Carlo simulation is an effective method for investigating the grafting reaction of free radical copolymerization. (C) 2000 Elsevier Science Ltd. All rights reserved.
Resumo:
Using poly(styrene-co-maleic anhydride) as the backbone and poly(ethylene glycol) methyl ether as side chains,three kinds of comblike polymers of different side chain length were synthesized. The Li-salt complexes and their firms were prepared. The dynamic mechanical properties were investigated. It was found that the main chain was rigid and the side chain was flexible in this comblike polymer system. Based on the time-temperature equivalence principle, a master curve was constructed. By selecting T-alpha as reference temperature, Arrhenius plots of shift factor and iso-free-volume plots were attained. The values of WLF parameters C-1 and C-2 increase with increasing salt concentration. By reference to T-0 = 50 degrees C, the relation between the average relaxation time 1g tau(c) and Li-salt concentration C is linear. The master curves are displaced progressively to higher frequencies as the M-w of side chains is increased. The relation between the average relaxation time 1g tau(n) and M-w of side chains is also linear. And the master curves are movable with the change of salts. It shows the effect of different kinds of salt on relaxation time.
Resumo:
The crystal of the title compound (C10H18N2O9SZn M-r=407.69) belongs to the hexagonal system, space group P 6(5) with cell parameters: a=11.411 (2), c=20.908(4) Angstrom, V=2357.7(7) Angstrom(3), Z=6, D-c=1.723g/cm(3), F(000)=1260, mu(MoKa)=1.743mm(-1). The final R and omega R factors are 0.072 and 0.178 respectively for 1335 observed reflections. in the structure, zinc ions are bridged by 4,4'-bipyridine to form infinite chains. The sheets containing parallel chains stack along a 65 screw axis to give a helical staircase motif. The helical structure is mainly controlled by the hydrogen bonds.
Resumo:
Optically pumped stimulated emission behavior in an organic film was demonstrated in this study. The gain material consists of a laser dye perylene doped into polystyrene (PS) matrix in an appropriate weight ratio. The sample was transversely pumped by the three harmonic output of a mode-locked Nd:YAG laser. The change of the emission spectra showed a clear threshold action and gain narrowing phenomenon when increasing the excitation intensity. Three emission peaks were observed below the excitation threshold, which are locate at 446, 475 and 506 nm, respectively. However, only the gain narrowing peak centered at 475 nm could be detected above the threshold. The spectra narrowing observed results from the amplified spontaneous emission (ASE) in the gain material. (C) 2000 Elsevier Science S.A. All rights reserved.
Resumo:
The present report deals with some results on phase behavior, miscibility and phase separation for several polymer blends casting from solutions. These blends are grouped as the amorphous polymer blends, blends containing a crystalline polymer or two crystalline polymers. The blends of PMMA/PVAc were miscible and underwent phase separation at elevated temperature, exhibited LCST behavior. The benzoylated PPO has both UCST and LCST nature. For the systems composed of crystalline polymer poly(ethylene oxide) and amorphous polyurethane, of two crystalline polymers poly(epsilon-caprolactone) and poly[3,3,-bis-(chloromethyl) oxetane], appear a single T-g, indicating these blends are miscible. The interaction parameter B's were determined to be -14 J cm(-3), -15 J cm(-3) respectively. Phase separation of phenolphthalein poly(ether ether sulfone)/PEO blends were discussed in terms of thermal properties, such as their melting and crystallization behavior.
Resumo:
The comblike polymers based on poly (styrene-co-maleic anhydride) backbone with poly (ethylene glycol) methyl ether as side chains were synthesized and characterized by H-1 NMR. with the result compared with that of 1R. It is found that it is both feasible and simple to synthesize this kind of compounds with the help of H-1 NMR.
Resumo:
This paper studies the radiation properties of the immiscible blend of nylon1010 and HIPS. The gel fraction increased with increasing radiation dose. The network was found mostly in nylon1010, the networks were also found in both nylon1010 and HIPS when the dose reaches 0.85 MGy or more. We used the Charleby-Pinner equation and the modified Zhang-Sun-Qian equation to simulate the relationship with the dose and the sol fraction. The latter equation fits well with these polymer blends and the relationship used by it showed better linearity than the one by the Charleby-Pinner equation. We also studied the conditions of formation of the network by the mathematical expectation theorem for the binary system. Thermal properties of polymer blend were observed by DSC curves. The crystallization temperature decreases with increasing dose because the cross-linking reaction inhibited the crystallization procession and destroyed the crystals. The melting temperature also reduced with increasing radiation dose. The dual melting peak gradually shifted to single peak and the high melting peak disappeared at high radiation dose. However, the radiation-induced crystallization was observed by the heat of fusion increasing at low radiation dose. On the other hand, the crystal will be damaged by radiation. A similar conclusion may be drawn by the DSC traces when the polymer blends were crystallized. When the radiation dose increases, the heat of fusion reduces dramatically and so does the heat of crystallization. (C) 1999 Elsevier Science Ltd. All rights reserved.
Resumo:
Full Paper: The phase, behavior of A-B-random copolymer/C-homopolymer, blends with special interaction was studied by a. Monte, Carlo simulation in two dimensions. The interaction between I segment A and segment C was repulsive, whereas it was attractive between segment B and segment C. The simulation results showed that the blend became two large co-continuous phase domains at lower segment-B component compositions, indicating that the blend showed spinodal decomposition. With an increase of the segment-B component, the miscibility between the copolymer,and the polymer was gradually improved up to being miscible. In addition, it was found that segment B tended to move to the surface of the copolymer phase in the case of a lower component of segment B. On the other hand, if was observed that the average, end-to-end distances ((h) over bar) for both copolymer and polymer changed slowly with increasing segment-B component of the copolymer up to 40%, thereafter they increased considerably with increasing segment B component. Moreover, it was found that the (h) over bar of the copolymer was obviously shorter than that of the homopolymer for the segment-B composition, region from 0% to 80%. Finally, a, phase diagram showing I phase and - II phase regions under the condition of constant-temperature is presented.
Resumo:
A simple route to the fabrication of multilayer films containing Pd nanoparticles is described. Following layer-by-layer assembly of PdCl42- and polycation, QPVP-Os (a quaternized poly(4-vinylpyridine) complexed with [Os(bpy)(2)Cl](2+/+)), on 4-aminobenzoic acid-modified glassy carbon electrodes, the three-dimensional Pd nanoparticle multilayer films are directly formed on electrode surfaces via electrochemical reduction of PdCl42- sandwiched between polymers. The growth of PdCl42- is easy on electrode surfaces by electrostatic interaction, and the assembly processes are monitored by cyclic voltammetry and UV-vis spectroscopy. The depth profile analyses by X-ray photoelectron spectroscopy verify the constant composition of the Pd nanoparticle multilayer films. Atomic force microscopy proves that the as-prepared Pd nanoparticles are uniformly distributed with an average particle diameter of 3-7 mn. The resulting Pd nanoparticle multilayer-modified electrode possesses high catalytic activity for the reduction of dissolved oxygen and oxidation of hydrazine compounds in aqueous solution.
Resumo:
The steady-state fluorescence properties of naphthalene-labeled polymers dispersed in poly(methyl methacrylate) (PMMA) cast films were studied under tensile loadings at 80 degreesC. The labeled polymers were composed of methyl methacrylate (MMA) and 1-naphthylmethyl methacrylate (NMMA). Three of the copolymers were used in this work, and the contents of NMMA were 0.59 mol % (CP1), 22.0 mol % (CP2), and 56.7 mol % (CP3), respectively. The fluorescence spectra of the films containing CP1 and CP2were unchanged during elongation. For the film containing CP3, the excited monomer emission of naphthyl groups at around 337 nm decreased with increasing applied tensile strain. The strain enhanced the emission ascribed to the excimer of the naphthyl groups in the region of 390-420 nm. The ratio of fluorescence intensities at 400 nm and 337 mn, I-400/I-337, increased with the applied strain, which indicates that CP3 is a sensitive probe for detecting the structural changes of polymer matrices. The obtained results mean that the excimer-forming sites in the PMMA films during elongation depend both on the applied strain and the concentration of naphthyl groups in the dispersed polymer probes. (C) 2001 John Wiley & Sons, Inc.
Resumo:
The morphology of films of isotactic polypropylene poly (3-dodecylthiophene) and iPP/P3DDT blend formed in electrostatic fields has been investigated by using scanning electron microscope. The experiment results show that the micro-crystal morphology of polymer films was strongly dependent on electrostatic fields. It was found that the effect of the electrostatic field led to the formation of dendrite crystals aligned in the field direction, and some branches of P3DDT ruptured. However, the micro-crystals in these films grew into spherulites without electrostatic field,and have no crystal orientation.
Resumo:
The micro-crystal morphology of the films of isotactic polypropylene (iPP), poly(3-dodecylthiophene) (P3DDT) and iPP/P3DDT blend grown in different electrostatic environments has been investigated by using scanning electron microscope. The experimental results show that the micro-crystal morphology of polymer films was strongly dependent on electrostatic field. It was found that the micro-crystal morphology of the films of iPP, P3DDT and iPP/P3DDT blend grown in the electrostatic field was in the form of dendrite crystals, in which main stems were aligned in the field direction, and some branches of P3DDT were ruptured. However, the micro-crystals of the films of iPP, P3DDT and iPP/P3DDT blend have no crystal orientation in the absence of electrostatic field. (C) 2001 Elsevier Science Ltd. All rights reserved.
Resumo:
A composite polymer electrolyte of Polyethylene oxide (PEO)-LiClO4 containing fine Al2O3 particles was studied by using differential scanning calorimetry, infrared spectroscopy and electrochemical impedance spectroscopy. Compared with the polymer electrolyte without Al2O3 particles, the glass transition temperature and the degree of crystallinity were decreased, and the room temperature conductivity of PEO-LiClO4-Al2O3 composite polymer electrolyte was considerably enhanced. Moreover, the equivalent circuits and the effect of dc potential on impedance spectroscopy were discussed.
Resumo:
The effect of PMR-polyimide(POI) as the interfacial agent on the interface characteristics, morphology features and crystallization of poly (ether sulfone) /poly (phenylene sulfide) (PES/PPS) and poly(ether ether ketone)/poly (ether sulfone) (PEEK/PES) partly miscible blends were investigated by means of the scanning electron microscopy, WAXD and XPS surface analysis. It is found that the interfacial adhesion was enhanced remarkably, the size of the dispersed phase particles was reduced significantly and the miscibility was improved by the addition of POI. During melt blending cross-link and/or grafting reaction of POI with PES, PEEK and PPS homopolymers was detected, however the reaction activity of POI with PPS was much higher than that of PES and PEEK. It was also found that POI was an effective nucleation agent of the crystallization of PPS.