984 resultados para opto-electronic materials


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Comparison of donor-acceptor electronic couplings calculated within two-state and three-state models suggests that the two-state treatment can provide unreliable estimates of Vda because of neglecting the multistate effects. We show that in most cases accurate values of the electronic coupling in a π stack, where donor and acceptor are separated by a bridging unit, can be obtained as Ṽ da = (E2 - E1) μ12 Rda + (2 E3 - E1 - E2) 2 μ13 μ23 Rda2, where E1, E2, and E3 are adiabatic energies of the ground, charge-transfer, and bridge states, respectively, μij is the transition dipole moments between the states i and j, and Rda is the distance between the planes of donor and acceptor. In this expression based on the generalized Mulliken-Hush approach, the first term corresponds to the coupling derived within a two-state model, whereas the second term is the superexchange correction accounting for the bridge effect. The formula is extended to bridges consisting of several subunits. The influence of the donor-acceptor energy mismatch on the excess charge distribution, adiabatic dipole and transition moments, and electronic couplings is examined. A diagnostic is developed to determine whether the two-state approach can be applied. Based on numerical results, we showed that the superexchange correction considerably improves estimates of the donor-acceptor coupling derived within a two-state approach. In most cases when the two-state scheme fails, the formula gives reliable results which are in good agreement (within 5%) with the data of the three-state generalized Mulliken-Hush model

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electronic coupling Vda is one of the key parameters that determine the rate of charge transfer through DNA. While there have been several computational studies of Vda for hole transfer, estimates of electronic couplings for excess electron transfer (ET) in DNA remain unavailable. In the paper, an efficient strategy is established for calculating the ET matrix elements between base pairs in a π stack. Two approaches are considered. First, we employ the diabatic-state (DS) method in which donor and acceptor are represented with radical anions of the canonical base pairs adenine-thymine (AT) and guanine-cytosine (GC). In this approach, similar values of Vda are obtained with the standard 6-31 G* and extended 6-31++ G* basis sets. Second, the electronic couplings are derived from lowest unoccupied molecular orbitals (LUMOs) of neutral systems by using the generalized Mulliken-Hush or fragment charge methods. Because the radical-anion states of AT and GC are well reproduced by LUMOs of the neutral base pairs calculated without diffuse functions, the estimated values of Vda are in good agreement with the couplings obtained for radical-anion states using the DS method. However, when the calculation of a neutral stack is carried out with diffuse functions, LUMOs of the system exhibit the dipole-bound character and cannot be used for estimating electronic couplings. Our calculations suggest that the ET matrix elements Vda for models containing intrastrand thymine and cytosine bases are essentially larger than the couplings in complexes with interstrand pyrimidine bases. The matrix elements for excess electron transfer are found to be considerably smaller than the corresponding values for hole transfer and to be very responsive to structural changes in a DNA stack

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study we report on the electronic and vibrational (hyper)polarizabilities of donor–acceptorsubstituted azobenzene. It is observed that both electronic and vibrational contributions to the electricdipole first hyperpolarizability of investigated photoactive molecule substantially depend on the conformation. The contributions to the nuclear relaxation first hyperpolarizability are found to be quite important in the case of two considered isomers (cis and trans). Although the double-harmonic term is found to be the largest in terms of magnitude, it is shown that the total value of the nuclear relaxation contribution to vibrational first hyperpolarizability is a result of subtle interplay of higher-order contributions. As a part of the study, we also assess the performance of long-range-corrected densityfunctional theory in determining vibrational contributions to electric dipole (hyper)polarizabilities. In most cases, the applied long-range-corrected exchange correlation potentials amend the drawbacks of their conventional counterparts

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The objective of this study was to evaluate the long-term safety and pharmacokinetic profile of a dexamethasone-loaded poly-epsilon-caprolactone (PCL) intravitreous implant. METHODS: The PCL devices were prepared by compression and were inserted into the vitreous of pigmented rabbits. At different time points, vitreous samples were retrieved, and dexamethasone concentration was analyzed by high-performance liquid chromatography. The biodegradation of the implants was evaluated by scanning electron microscopy, and the dexamethasone remaining was evaluated at the end of follow-up. Clinical and histologic examinations were performed to evaluate the implant's tolerance. RESULTS: The PCL implant allows for a controlled and prolonged delivery of dexamethasone in rabbits eyes since it released the drug within the therapeutic range for at least 55 weeks. At 55 weeks approximately 79% of the drug was still present in the implant. Biodegradation study showed that PCL implants degradation is very slow. Clinical and histologic observations showed that the devices were very well tolerated in the rabbit eye. CONCLUSIONS: This study demonstrates the feasibility and tolerance of intravitreous PCL drug delivery systems, which can offer a wide range of applications for intraocular drug delivery because of their controlled and prolonged release over months or even years.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: Atomic force microscopy nanoindentation of myofibers was used to assess and quantitatively diagnose muscular dystrophies from human patients. MATERIALS & METHODS: Myofibers were probed from fresh or frozen muscle biopsies from human dystrophic patients and healthy volunteers, as well as mice models, and Young's modulus stiffness values were determined. RESULTS: Fibers displaying abnormally low mechanical stability were detected in biopsies from patients affected by 11 distinct muscle diseases, and Young's modulus values were commensurate to the severity of the disease. Abnormal myofiber resistance was also observed from consulting patients whose muscle condition could not be detected or unambiguously diagnosed otherwise. DISCUSSION & CONCLUSION: This study provides a proof-of-concept that atomic force microscopy yields a quantitative read-out of human muscle function from clinical biopsies, and that it may thereby complement current muscular dystrophy diagnosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El projecte Microscòpia d'alta resolució aplicada a anàlisis traceològiques, tafonòmiques y zooarqueològiques ha permès donar continuïtat i ampliar la xarxa científica posada en marxa gràcies a dos projectes PBR anteriors entre l’IPHES i quatre centres anglesos: l’Institute of Archaeology del University College of London, el Dept of Prehistory and Europe del British Museum, el Dept of Palaeontology del Natural History Museum, i el Lithic Microwear Research Laboratory de la University of Bradford. El tema tractat ha estat l’avaluació de la resolució i de la possible complementarietat de diferents tècniques avançades de microscòpia per a l’anàlisi de les superfícies d’ossos i eines de pedra prehistòriques: microscòpia òptica, electrònica (SEM i ESEM), microscòpia làser confocal (LSCM) i el sistema Alicona 3D Infinite Imaging. Les diverses accions de mobilitat entre Catalunya i el Regne Unit realitzades han permès satisfactòriament posar en comú els procediments emprats pels diferents especialistes de cada centre. Les proves realitzades sobre materials de jaciments arqueològics clau tant britànics com de l’estat espanyol han permès avaluar els avantatges i limitacions que cada tècnica presentava segons la mostra estudiada (eines de pedra, ossos, dents...) i segons els requeriments específics de l’estudi plantejat. En termes generals, s’ha posat en evidència que les diferents tècniques explorades són força complementàries. És a dir, la gran capacitat d’augments i de resolució d’imatge dels microscopis electrònics es complementa amb unes meravelloses prestacions quant anàlisi de textures, de perfils i de reconstrucció 3D dels altres aparells. La principal conclusió que podem extreure, doncs, és que l’estudi d’aquest tipus d’objectes arqueològics requereix de l’ús combinat de diferents aparells de microscòpia. Tant els treballs realitzats com els contactes entre especialistes establerts al llarg del projecte s’han plasmat ja en treballs concrets, alguns d’ells ja publicats o en fase final de publicació.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the influence of shorter- and longer-acting intra-articular anaesthetics on post-arthrographic pain. MATERIALS AND METHODS: 154 consecutive patients investigated by MR or CT arthrographies were randomly assigned to one of the following groups: 1--intra-articular contrast injection only; 2--lidocain 1% adjunction; or 3--bupivacain 0.25% adjunction. Pain was assessed before injection, at 15 min, 4 h, 1 day and 1 week after injection by visual analogue scale (VAS). RESULTS: At 15 min, early mean pain score increased by 0.96, 0.24 and 0 in groups 1, 2 and 3, respectively. Differences between groups 1 & 3 and 1 & 2 were statistically significant (p=0.003 and 0.03, respectively), but not between groups 2 & 3 (p=0.54). Delayed mean pain score increase was maximal at 4 h, reaching 1.60, 1.22 and 0.29 in groups 1, 2 and 3, respectively. Differences between groups 1 & 2 and 2 & 3 were statistically significant (p=0.002 and 0.02, respectively), but not between groups 1 & 2 (p=0.46). At 24 h and 1 week, the interaction of local anaesthetics with increase in pain score was no longer significant. Results were independent of age, gender and baseline VAS. CONCLUSION: Intra-articular anaesthesia may significantly reduce post-arthrographic pain. Bupivacain seems to be more effective than lidocain to reduce both early and delayed pain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Report for the scientific sojourn carried out at the Paul Drude Institut für Festkörperelektronik of the Stanford University, USA, from 2010 to 2012. The objective of this project is the transport and control of electronic charge and spin along GaAs-based semiconductor heterostructures. The electronic transport has been achieved by taking advantage of the piezolectric field induced by surface acoustic waves in non-centrosymmetric materials like GaAs. This piezolectric field separates photogenerated electrons and holes at different positions along the acoustic wave, where they acummulate and are transported at the same velocity as the wave. Two different kinds of structures have been studied: quantum wells grown along the (110) direction, both intrinsic and n-doped, as well as GaAs nanowires. The analysis of the charge acoustic transport was performed by micro-photoluminescence, whereas the detection of the spin transport was done either by analyzing the polarization state of the emitted photoluminescence or by Kerr reflectometry. Our results in GaAs quantum wells show that charge and spin transport is clearly observed at the non-doped structures,obtaining spin lifetimes of the order of several nanoseconds, whereas no acoutically induced spin transport was detected for the n-doped quantum wells. In the GaAs nanowires, we were able of transporting successfully both electrons and holes along the nanowire axis, but no conservation of the spin polarization has been observed until now. The photoluminescence emitted by these structures after acoustic transport, however, shows anti-bunching characteristics, making this system a very good candidate for its use as single photon emitters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: To update the pattern of cancer mortality in Europe. Materials and methods: We analysed cancer mortality in 34 European countries during 2000-2004, with an overview of trends in 1975-2004 using data from the World Health Organization. RESULTS: From 1990-1994 to 2000-2004, overall cancer mortality in the European Union declined from 185.2 to 168.0/100 000 (world standard, -9%) in men and from 104.8 to 96.9 (-8%) in women, with larger falls in middle age. Total cancer mortality trends were favourable, though to a variable degree, in all major European countries, including Russia, but not in Romania. The major determinants of these favourable trends were the decline of lung (-16%) and other tobacco-related cancers in men, together with the persistent falls in gastric cancer, and the recent appreciable falls in colorectal cancer. In women, relevant contributions came from the persistent decline in cervical cancer and the recent falls in breast cancer mortality, particularly in northern and western Europe. Favourable trends were also observed for testicular cancer, Hodgkin lymphomas, leukaemias, and other neoplasms amenable to treatment, though the reductions were still appreciably smaller in eastern Europe. CONCLUSION: This updated analysis of cancer mortality in Europe showed a persistent favourable trend over the last years.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Report for the scientific sojourn carried out at Massachusetts General Hospital Cancer Center-Harvard Medical School, Estats Units, from 2010 to 2011. The project aims to study the aggregation behavior of amphiphilic molecules in the continuous phase of highly concentrated emulsions, which can be used as templates for the synthesis of meso/macroporous materials. At this stage of the project, we have investigated the self-assembly of diblock and triblock surfactants under the effect of a confined geometry being surrounded by the droplets of the dispersed phase. These droplets limit the growth of the aggregates, deeply modify their orientation and hence alter their spatial arrangement as compared to the self-assembly taking place far enough from any boundary surface, that is in the bulk. By performing Monte Carlo simulations, we have showed that the interface between the dispersed and continuous phases as well as its shape has a significant impact on the structural order of the resulting aggregates and hence on the potential applications of highly concentrated emulsions as reaction media, drug delivery systems, or templates for meso/macroporous materials. Due to the combined effect of symmetry breaking and morphological frustration, very intriguing structures, such as square columnar liquid crystals, twisted X-shaped aggregates, and helical phases of cylindrical aggregates, never observed in the bulk for the same model surfactant, have been found. The presence of other more conventional structures, such as micelles and cubic and hexagonal liquid crystals, formed at low and high amphiphilic concentrations, respectively, further enhance the interest on this already rich aggregation behavior.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The aim of this study was to assess the outcome of patients with primary spinal myxopapillary ependymoma (MPE). MATERIALS AND METHODS: Data from a series of 85 (35 females, 50 males) patients with spinal MPE were collected in this retrospective multicenter study. Thirty-eight (45%) underwent surgery only and 47 (55%) received postoperative radiotherapy (RT). Median administered radiation dose was 50.4 Gy (range, 22.2-59.4). Median follow-up of the surviving patients was 60.0 months (range, 0.2-316.6). RESULTS: The 5-year progression-free survival (PFS) was 50.4% and 74.8% for surgery only and surgery with postoperative low- (<50.4 Gy) or high-dose (>or=50.4 Gy) RT, respectively. Treatment failure was observed in 24 (28%) patients. Fifteen patients presented treatment failure at the primary site only, whereas 2 and 1 patients presented with brain and distant spinal failure only. Three and 2 patients with local failure presented with concomitant spinal distant seeding and brain failure, respectively. One patient failed simultaneously in the brain and spine. Age greater than 36 years (p = 0.01), absence of neurologic symptoms at diagnosis (p = 0.01), tumor size >or=25 mm (p = 0.04), and postoperative high-dose RT (p = 0.05) were variables predictive of improved PFS on univariate analysis. In multivariate analysis, only postoperative high-dose RT was independent predictors of PFS (p = 0.04). CONCLUSIONS: The observed pattern of failure was mainly local, but one fifth of the patients presented with a concomitant spinal or brain component. Postoperative high-dose RT appears to significantly reduce the rate of tumor progression.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Estudi realitzat a partir d’una estada a l’ Institut für Komplexe Materialien, Leibniz-Institut für Festkörper- und Werkstoffforschung Dresden, entre 2010 i 2011. S'ha explorat l'efecte de les condicions i influència dels elements d'aleació en la capacitat de formació de vidre, l'estructura i les propietats tèrmiques i magnètiques de vidres metàl•lics massissos i materials nanocristal•lins en base Fe. La producció d'aquests materials en forma de cintes de unes 20 micres de gruix ha estat àmpliament estudiada i s'ha vist que presenten unes propietats excel•lents com a materials magnètics tous. El propòsit general d'aquest projecte era l'obtenció de composicions òptimes amb alta capacitat de formar vidre i amb excel•lents propietats magnètiques com a materials magnètics tous combinat amb bones propietats mecàniques. El projecte prenia com a punt de partida l'aliatge [FeCoBSi]96Nb4 ja que és el que presenta millor capacitat de formar vidre i presenta una alta imantació de saturació i baix camp coercitiu. S'ha fet un estudi dels factors fonamentals que intervenen en la formació de l'estat vitri. La composició abans esmentada ha estat variada amb l'addició d'altres elements per estudiar com afecten aquests nous elements a les propietats, la formació de vidre i l'estructura dels aliatges resultants amb l'objectiu de millorar-ne les propietats magnètiques i la capacitat de formació de vidre. Entre altres s'ha usat el Zr, Mo, Y i el Gd per millorar la formació de vidre; i el Co i el Ni per millorar les propietats magnètiques a alta temperatura. S'han estudiat les relacions entre la capacitat de formació de vidre i la seva estabilitat tèrmica, la resistència a la cristal•lització i la estructura de l'aliatge resultant després del procés de solidificació. Per aquest estudi s'han determinat els mecanismes que controlen la transformació i la seva cinètica així com les fases que es formen durant el tractament tèrmic permetent la formulació de models predictius.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RATIONALE AND OBJECTIVES: To systematically review and meta-analyze published data about the diagnostic accuracy of fluorine-18-fluorodeoxyglucose ((18)F-FDG) positron emission tomography (PET) and PET/computed tomography (CT) in the differential diagnosis between malignant and benign pleural lesions. METHODS AND MATERIALS: A comprehensive literature search of studies published through June 2013 regarding the diagnostic performance of (18)F-FDG-PET and PET/CT in the differential diagnosis of pleural lesions was carried out. All retrieved studies were reviewed and qualitatively analyzed. Pooled sensitivity, specificity, positive and negative likelihood ratio (LR+ and LR-) and diagnostic odds ratio (DOR) of (18)F-FDG-PET or PET/CT in the differential diagnosis of pleural lesions on a per-patient-based analysis were calculated. The area under the summary receiver operating characteristic curve (AUC) was calculated to measure the accuracy of these methods. Subanalyses considering device used (PET or PET/CT) were performed. RESULTS: Sixteen studies including 745 patients were included in the systematic review. The meta-analysis of 11 selected studies provided the following results: sensitivity 95% (95% confidence interval [95%CI]: 92-97%), specificity 82% (95%CI: 76-88%), LR+ 5.3 (95%CI: 2.4-11.8), LR- 0.09 (95%CI: 0.05-0.14), DOR 74 (95%CI: 34-161). The AUC was 0.95. No significant improvement of the diagnostic accuracy considering PET/CT studies only was found. CONCLUSIONS: (18)F-FDG-PET and PET/CT demonstrated to be accurate diagnostic imaging methods in the differential diagnosis between malignant and benign pleural lesions; nevertheless, possible sources of false-negative and false-positive results should be kept in mind.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Vaccines targeting tumor associated antigens are in development for bladder cancer. Most of these cancers are nonmuscle invasive at diagnosis and confined in the mucosa and submucosa. However, to our knowledge how vaccination may induce the regression of tumors at such mucosal sites has not been examined previously. We compared different immunization routes for the ability to induce vaccine specific antitumor CD8 T cells in the bladder and bladder tumor regression in mice. MATERIALS AND METHODS: In the absence of a murine bladder tumor model expressing a tumor antigen relevant for human use we established an orthotopic model expressing the HPV-16 tumor antigen E7 as a model. We used an adjuvant E7 polypeptide to induce CD8 T cell mediated tumor regression. RESULTS: Subcutaneous and intravaginal but not intranasal vaccination induced a high number of TetE7(+)CD8(+) T cells in the bladder as well as bladder tumor regression. The entry of vaccine specific T cells in the bladder was not the only key since persistent regression of established bladder tumors by intravaginal or subcutaneous immunization was associated with tumor infiltration of total CD4 and CD8 T cells. This resulted in an increase in TetE7(+)CD8(+) T cells and a decrease in T regulatory cells, leading to an increased number of effector interferon-γ secreting vaccine specific CD8 T cells in the regressing bladder tumor. CONCLUSIONS: These data show that immunization routes should be tailored to each mucosal tumor site. Subcutaneous or intravaginal vaccination may be of additional value to treat patients with bladder cancer.