949 resultados para low dose irradiation
Resumo:
PURPOSE: Early assessment of radiotherapy (RT) quality in the ongoing EORTC trial comparing primary temozolomide versus RT in low-grade gliomas. MATERIALS AND METHODS: RT plans provided for dummy cases were evaluated and compared against expert plans. We analysed: (1) tumour and organs-at-risk delineation, (2) geometric and dosimetric characteristics, (3) planning parameters, compliance with dose prescription and Dmax for OAR (4) indices: RTOG conformity index (CI), coverage factor (CF), tissue protection factor (PF); conformity number (CN = PF x CF); dose homogeneity in PTV (U). RESULTS: Forty-one RT plans were evaluated. Only two (5%) centres were requested to repeat CTV-PTV delineations. Three (7%) plans had a significant under-dosage and dose homogeneity in one deviated > 10%. Dose distribution was good with mean values of 1.5, 1, 0.68, and 0.68 (ideal values = 1) for CI, CF, PF, and CN, respectively. CI and CN strongly correlated with PF and they correlated with PTV. Planning with more beams seems to increase PTV(Dmin), improving CF. U correlated with PTV(Dmax). CONCLUSION: Preliminary results of the dummy run procedure indicate that most centres conformed to protocol requirements. To quantify plan quality we recommend systematic calculation of U and either CI or CN, both of which measure the amount of irradiated normal brain tissue.
Resumo:
In vivo dosimetry is a way to verify the radiation dose delivered to the patient in measuring the dose generally during the first fraction of the treatment. It is the only dose delivery control based on a measurement performed during the treatment. In today's radiotherapy practice, the dose delivered to the patient is planned using 3D dose calculation algorithms and volumetric images representing the patient. Due to the high accuracy and precision necessary in radiation treatments, national and international organisations like ICRU and AAPM recommend the use of in vivo dosimetry. It is also mandatory in some countries like France. Various in vivo dosimetry methods have been developed during the past years. These methods are point-, line-, plane- or 3D dose controls. A 3D in vivo dosimetry provides the most information about the dose delivered to the patient, with respect to ID and 2D methods. However, to our knowledge, it is generally not routinely applied to patient treatments yet. The aim of this PhD thesis was to determine whether it is possible to reconstruct the 3D delivered dose using transmitted beam measurements in the context of narrow beams. An iterative dose reconstruction method has been described and implemented. The iterative algorithm includes a simple 3D dose calculation algorithm based on the convolution/superposition principle. The methodology was applied to narrow beams produced by a conventional 6 MV linac. The transmitted dose was measured using an array of ion chambers, as to simulate the linear nature of a tomotherapy detector. We showed that the iterative algorithm converges quickly and reconstructs the dose within a good agreement (at least 3% / 3 mm locally), which is inside the 5% recommended by the ICRU. Moreover it was demonstrated on phantom measurements that the proposed method allows us detecting some set-up errors and interfraction geometry modifications. We also have discussed the limitations of the 3D dose reconstruction for dose delivery error detection. Afterwards, stability tests of the tomotherapy MVCT built-in onboard detector was performed in order to evaluate if such a detector is suitable for 3D in-vivo dosimetry. The detector showed stability on short and long terms comparable to other imaging devices as the EPIDs, also used for in vivo dosimetry. Subsequently, a methodology for the dose reconstruction using the tomotherapy MVCT detector is proposed in the context of static irradiations. This manuscript is composed of two articles and a script providing further information related to this work. In the latter, the first chapter introduces the state-of-the-art of in vivo dosimetry and adaptive radiotherapy, and explains why we are interested in performing 3D dose reconstructions. In chapter 2 a dose calculation algorithm implemented for this work is reviewed with a detailed description of the physical parameters needed for calculating 3D absorbed dose distributions. The tomotherapy MVCT detector used for transit measurements and its characteristics are described in chapter 3. Chapter 4 contains a first article entitled '3D dose reconstruction for narrow beams using ion chamber array measurements', which describes the dose reconstruction method and presents tests of the methodology on phantoms irradiated with 6 MV narrow photon beams. Chapter 5 contains a second article 'Stability of the Helical TomoTherapy HiArt II detector for treatment beam irradiations. A dose reconstruction process specific to the use of the tomotherapy MVCT detector is presented in chapter 6. A discussion and perspectives of the PhD thesis are presented in chapter 7, followed by a conclusion in chapter 8. The tomotherapy treatment device is described in appendix 1 and an overview of 3D conformai- and intensity modulated radiotherapy is presented in appendix 2. - La dosimétrie in vivo est une technique utilisée pour vérifier la dose délivrée au patient en faisant une mesure, généralement pendant la première séance du traitement. Il s'agit de la seule technique de contrôle de la dose délivrée basée sur une mesure réalisée durant l'irradiation du patient. La dose au patient est calculée au moyen d'algorithmes 3D utilisant des images volumétriques du patient. En raison de la haute précision nécessaire lors des traitements de radiothérapie, des organismes nationaux et internationaux tels que l'ICRU et l'AAPM recommandent l'utilisation de la dosimétrie in vivo, qui est devenue obligatoire dans certains pays dont la France. Diverses méthodes de dosimétrie in vivo existent. Elles peuvent être classées en dosimétrie ponctuelle, planaire ou tridimensionnelle. La dosimétrie 3D est celle qui fournit le plus d'information sur la dose délivrée. Cependant, à notre connaissance, elle n'est généralement pas appliquée dans la routine clinique. Le but de cette recherche était de déterminer s'il est possible de reconstruire la dose 3D délivrée en se basant sur des mesures de la dose transmise, dans le contexte des faisceaux étroits. Une méthode itérative de reconstruction de la dose a été décrite et implémentée. L'algorithme itératif contient un algorithme simple basé sur le principe de convolution/superposition pour le calcul de la dose. La dose transmise a été mesurée à l'aide d'une série de chambres à ionisations alignées afin de simuler la nature linéaire du détecteur de la tomothérapie. Nous avons montré que l'algorithme itératif converge rapidement et qu'il permet de reconstruire la dose délivrée avec une bonne précision (au moins 3 % localement / 3 mm). De plus, nous avons démontré que cette méthode permet de détecter certaines erreurs de positionnement du patient, ainsi que des modifications géométriques qui peuvent subvenir entre les séances de traitement. Nous avons discuté les limites de cette méthode pour la détection de certaines erreurs d'irradiation. Par la suite, des tests de stabilité du détecteur MVCT intégré à la tomothérapie ont été effectués, dans le but de déterminer si ce dernier peut être utilisé pour la dosimétrie in vivo. Ce détecteur a démontré une stabilité à court et à long terme comparable à d'autres détecteurs tels que les EPIDs également utilisés pour l'imagerie et la dosimétrie in vivo. Pour finir, une adaptation de la méthode de reconstruction de la dose a été proposée afin de pouvoir l'implémenter sur une installation de tomothérapie. Ce manuscrit est composé de deux articles et d'un script contenant des informations supplémentaires sur ce travail. Dans ce dernier, le premier chapitre introduit l'état de l'art de la dosimétrie in vivo et de la radiothérapie adaptative, et explique pourquoi nous nous intéressons à la reconstruction 3D de la dose délivrée. Dans le chapitre 2, l'algorithme 3D de calcul de dose implémenté pour ce travail est décrit, ainsi que les paramètres physiques principaux nécessaires pour le calcul de dose. Les caractéristiques du détecteur MVCT de la tomothérapie utilisé pour les mesures de transit sont décrites dans le chapitre 3. Le chapitre 4 contient un premier article intitulé '3D dose reconstruction for narrow beams using ion chamber array measurements', qui décrit la méthode de reconstruction et présente des tests de la méthodologie sur des fantômes irradiés avec des faisceaux étroits. Le chapitre 5 contient un second article intitulé 'Stability of the Helical TomoTherapy HiArt II detector for treatment beam irradiations'. Un procédé de reconstruction de la dose spécifique pour l'utilisation du détecteur MVCT de la tomothérapie est présenté au chapitre 6. Une discussion et les perspectives de la thèse de doctorat sont présentées au chapitre 7, suivies par une conclusion au chapitre 8. Le concept de la tomothérapie est exposé dans l'annexe 1. Pour finir, la radiothérapie «informationnelle 3D et la radiothérapie par modulation d'intensité sont présentées dans l'annexe 2.
Resumo:
A questionnaire was developed by the members of WG12 of EURADOS in order to establish an overview of the current status of eye lens radiation dose monitoring in hospitals. The questionnaire was sent to medical physicists and radiation protection officers in hospitals across Europe. Specific topics were addressed in the questionnaire such as: knowledge of the proposed eye lens dose limit; monitoring and dosimetry issues; training and radiation protection measures. The results of the survey highlighted that the new eye lens dose limit can be exceeded in interventional radiology procedures and that eye lens protection is crucial. Personnel should be properly trained in how to use protective equipment in order to keep eye lens doses as low as reasonably achievable. Finally, the results also highlighted the need to improve the design of eye dosemeters in order to ensure satisfactory use by workers.
Resumo:
Background In a previous study, the European Organisation for Research and Treatment of Cancer (EORTC) reported a scoring system to predict survival of patients with low-grade gliomas (LGGs). A major issue in the diagnosis of brain tumors is the lack of agreement among pathologists. New models in patients with LGGs diagnosed by central pathology review are needed. Methods Data from 339 EORTC patients with LGGs diagnosed by central pathology review were used to develop new prognostic models for progression-free survival (PFS) and overall survival (OS). Data from 450 patients with centrally diagnosed LGGs recruited into 2 large studies conducted by North American cooperative groups were used to validate the models. Results Both PFS and OS were negatively influenced by the presence of baseline neurological deficits, a shorter time since first symptoms (<30 wk), an astrocytic tumor type, and tumors larger than 5 cm in diameter. Early irradiation improved PFS but not OS. Three risk groups have been identified (low, intermediate, and high) and validated. Conclusions We have developed new prognostic models in a more homogeneous LGG population diagnosed by central pathology review. This population better fits with modern practice, where patients are enrolled in clinical trials based on central or panel pathology review. We could validate the models in a large, external, and independent dataset. The models can divide LGG patients into 3 risk groups and provide reliable individual survival predictions. Inclusion of other clinical and molecular factors might still improve models' predictions.
Resumo:
Introduction: Vitamin D plays a major role in bone metabolism and neuromuscular function. Supplementation with vitamin D is effective to reduce the risk of fall and of fracture. However adherence to oral daily vitamin D supplementation is low. Screening and correcting vitamin D insufficiency in a general rheumatologic population could improve both morbidity and quality of life in these patients with chronic painful disorders and at high risk of osteoporosis. After determining the prevalence of vitamin D deficiency in this population, we evaluated if supplementation with a single high dose of oral 25-OH vitamin D3 was sufficient to correct this abnormality. Methods: During one month (November 2009), levels of 25-OH vitamin D were systematically determined in our rheumatology outpatient clinic and classified into three groups: vitamin D deficiency (<10 μg/l), vitamin D insufficiency (10 to 30 μg/l) or normal vitamin D (>30 μg/l). Patients with insufficiency or deficiency received respectively a single high dose of 300000 IU or 600000 IU oral vitamin D3. In addition, all patients with osteoporosis were prescribed daily supplement of calcium (1 g) and vitamin D (800 IU). 25-OH vitamin D levels were reevaluated after 3 months. Results: Vitamin D levels were initially determined in 292 patients (mean age 53, 211 women, 87% Caucasian). 77% had inflammatory rheumatologic disease (IRD), 20% osteoporosis (OP) and 12% degenerative disease (DD). Vitamin D deficiency was present in 20 (6.8%), while 225 (77.1%) had insufficiency. Of the 245 patients with levels <30 μg/l, a new determination of vitamin D level was available in 173 (71%) at 3 months. Conclusion: Vitamin D insufficiency is highly prevalent in our rheumatologic population (84%), and is not adequately corrected by a single high dose of oral vitamin D3 in more than half of the patients with IRD and DD. In patients with OP, despite association of a single high dose with daily oral vitamin D supplementation, 40% of patients are still deficient when reevaluated at 3 months.
Resumo:
The aim was to propose a strategy for finding reasonable compromises between image noise and dose as a function of patient weight. Weighted CT dose index (CTDI(w)) was measured on a multidetector-row CT unit using CTDI test objects of 16, 24 and 32 cm in diameter at 80, 100, 120 and 140 kV. These test objects were then scanned in helical mode using a wide range of tube currents and voltages with a reconstructed slice thickness of 5 mm. For each set of acquisition parameter image noise was measured and the Rose model observer was used to test two strategies for proposing a reasonable compromise between dose and low-contrast detection performance: (1) the use of a unique noise level for all test object diameters, and (2) the use of a unique dose efficacy level defined as the noise reduction per unit dose. Published data were used to define four weight classes and an acquisition protocol was proposed for each class. The protocols have been applied in clinical routine for more than one year. CTDI(vol) values of 6.7, 9.4, 15.9 and 24.5 mGy were proposed for the following weight classes: 2.5-5, 5-15, 15-30 and 30-50 kg with image noise levels in the range of 10-15 HU. The proposed method allows patient dose and image noise to be controlled in such a way that dose reduction does not impair the detection of low-contrast lesions. The proposed values correspond to high- quality images and can be reduced if only high-contrast organs are assessed.
Resumo:
BACKGROUND: Low-molecular-weight heparin (LMWH) appears to be safe and effective for treating pulmonary embolism (PE), but its cost-effectiveness has not been assessed. METHODS: We built a Markov state-transition model to evaluate the medical and economic outcomes of a 6-day course with fixed-dose LMWH or adjusted-dose unfractionated heparin (UFH) in a hypothetical cohort of 60-year-old patients with acute submassive PE. Probabilities for clinical outcomes were obtained from a meta-analysis of clinical trials. Cost estimates were derived from Medicare reimbursement data and other sources. The base-case analysis used an inpatient setting, whereas secondary analyses examined early discharge and outpatient treatment with LMWH. Using a societal perspective, strategies were compared based on lifetime costs, quality-adjusted life-years (QALYs), and the incremental cost-effectiveness ratio. RESULTS: Inpatient treatment costs were higher for LMWH treatment than for UFH (dollar 13,001 vs dollar 12,780), but LMWH yielded a greater number of QALYs than did UFH (7.677 QALYs vs 7.493 QALYs). The incremental costs of dollar 221 and the corresponding incremental effectiveness of 0.184 QALYs resulted in an incremental cost-effectiveness ratio of dollar 1,209/QALY. Our results were highly robust in sensitivity analyses. LMWH became cost-saving if the daily pharmacy costs for LMWH were < dollar 51, if > or = 8% of patients were eligible for early discharge, or if > or = 5% of patients could be treated entirely as outpatients. CONCLUSION: For inpatient treatment of PE, the use of LMWH is cost-effective compared to UFH. Early discharge or outpatient treatment in suitable patients with PE would lead to substantial cost savings.
Resumo:
Introduction: Vitamin D plays a major role in bone metabolism and neuromuscular function. Supplementation with vitamin D is effective to reduce the risk of fall and of fracture. However adherence to oral daily vitamin D supplementation is low. Screening and correcting vitamin D insufficiency in a general rheumatologic population could improve both morbidity and quality of life in these patients with chronic painful disorders and at high risk of osteoporosis. After determining the prevalence of vitamin D deficiency in this population, we evaluated if supplementation with a single high dose of oral 25-OH vitamin D3 was sufficient to correct this abnormality. Methods: During one month (November 2009), levels of 25-OH vitamin D were systematically determined in our rheumatology outpatient clinic and classified into three groups: vitamin D deficiency (<10 µg/l), vitamin D insufficiency (10 to 30µg/l) or normal vitamin D (>30 µg/l). Patients with insufficiency or deficiency received respectively a single high dose of 300'000 IU or 600'000 IU oral vitamin D3. In addition, all patients with osteoporosis were prescribed daily supplement of calcium (1g) and vitamin D (800 IU). 25-OH vitamin D levels were reevaluated after 3 months. Results: Vitamin D levels were initially determined in 292 patients (mean age 53, 211 women, 87% Caucasian). 77% had inflammatory rheumatologic disease (IRD), 20% osteoporosis (OP) and 12% degenerative disease (DD). Vitamin D deficiency was present in 20 (6.8%), while 225 (77.1%) had insufficiency. Of the 245 patients with levels <30µg/l, a new determination of vitamin D level was available in 173 (71%) at 3 months (table 1). Conclusion: Vitamin D insufficiency is highly prevalent in our rheumatologic population (84%), and is not adequately corrected by a single high dose of oral vitamin D3 in more than half of the patients with IRD and DD. In patients with OP, despite association of a single high dose with daily oral vitamin D supplementation, 40% of patients are still deficient when reevaluated at 3 months.
Resumo:
PURPOSE This double-blind, multicenter trial compared the efficacy and safety of a single daily oral dose of moxifloxacin with oral combination therapy in low-risk febrile neutropenic patients with cancer. PATIENTS AND METHODS Inclusion criteria were cancer, febrile neutropenia, low risk of complications as predicted by a Multinational Association for Supportive Care in Cancer (MASCC) score > 20, ability to swallow, and ≤ one single intravenous dose of empiric antibiotic therapy before study drug treatment initiation. Early discharge was encouraged when a set of predefined criteria was met. Patients received either moxifloxacin (400 mg once daily) monotherapy or oral ciprofloxacin (750 mg twice daily) plus amoxicillin/clavulanic acid (1,000 mg twice daily). The trial was designed to show equivalence of the two drug regimens in terms of therapy success, defined as defervescence and improvement in clinical status during study drug treatment (< 10% difference). Results Among the 333 patients evaluated in an intention-to-treat analysis, therapy success was observed in 80% of the patients administered moxifloxacin and in 82% of the patients administered combination therapy (95% CI for the difference, -10% to 8%, consistent with equivalence). Minor differences in tolerability, safety, and reasons for failure were observed. More than 50% of the patients in the two arms were discharged on protocol therapy, with 5% readmissions among those in either arm. Survival was similar (99%) in both arms. CONCLUSION Monotherapy with once daily oral moxifloxacin is efficacious and safe in low-risk febrile neutropenic patients identified with the help of the MASCC scoring system, discharged early, and observed as outpatients.
Resumo:
Introduction: As imatinib pharmacokinetics are highly variable, plasma levels differ largely between patients under the same dosage. Retrospective studies in chronic myeloid leukemia (CML) patients showed significant correlations between low levels and suboptimal response, as well as between high levels and poor tolerability. Monitoring of trough plasma levels, targeting 1000 μg/L and above, is thus increasingly advised. Our study was launched to assess prospectively the clinical usefulness of systematic imatinib TDM in CML patients. This preliminary analysis addresses the appropriateness of the dosage adjustment approach applied in this study, which targets the recommended trough level and allows an interval of 4-24 h after last drug intake for blood sampling. Methods: Blood samples from the first 15 patients undergoing 1st TDM were obtained 1.5-25 h after last dose. Imatinib plasma levels were measured by LC-MS/MS and the concentrations were extrapolated to trough based on a Bayesian approach using a population pharmacokinetic model. Trough levels were predicted to differ significantly from the target in 12 patients (10 <750 μg/L; 2 >1500 μg/L along with poor tolerance) and individual dose adjustments were proposed. 8 patients underwent a 2nd TDM cycle. Trough levels of 1st and 2nd TDM were compared, the sample drawn 1.5 h after last dose (during distribution phase) was excluded from the analysis. Results: Individual dose adjustments were applied in 6 patients. Observed concentrations extrapolated to trough ranged from 360 to 1832 μg/L (median 725; mean 810, CV 52%) on 1st TDM and from 720 to 1187 μg/L (median 950; mean 940, CV 18%) on 2nd TDM cycle. Conclusions: These preliminary results suggest that TDM of imatinib using a Bayesian interpretation is able to target the recommended trough level of 1000 μg/L and to reduce the considerable differences in trough level exposure between patients (with CV decreasing from 52% to 18%). While this may simplify blood collection in daily practice, as samples do not have to be drawn exactly at trough, the largest possible interval to last drug intake yet remains preferable to avoid sampling during distribution phase leading to biased extrapolation. This encourages the evaluation of the clinical benefit of a routine TDM intervention in CML patients, which the randomized Swiss I-COME trial aims to.
Resumo:
Some methadone maintenance treatment (MMT) programs prescribe inadequate daily methadone doses. Patients complain of withdrawal symptoms and continue illicit opioid use, yet practitioners are reluctant to increase doses above certain arbitrary thresholds. Serum methadone levels (SMLs) may guide practitioners dosing decisions, especially for those patients who have low SMLs despite higher methadone doses. Such variation is due in part to the complexities of methadone metabolism. The medication itself is a racemic (50:50) mixture of 2 enantiomers: an active "R" form and an essentially inactive "S" form. Methadone is metabolized primarily in the liver, by up to five cytochrome P450 isoforms, and individual differences in enzyme activity help explain wide ranges of active R-enantiomer concentrations in patients given identical doses of racemic methadone. Most clinical research studies have used methadone doses of less than 100 mg/day [d] and have not reported corresponding SMLs. New research suggests that doses ranging from 120 mg/d to more than 700 mg/d, with correspondingly higher SMLs, may be optimal for many patients. Each patient presents a unique clinical challenge, and there is no way of prescribing a single best methadone dose to achieve a specific blood level as a "gold standard" for all patients. Clinical signs and patient-reported symptoms of abstinence syndrome, and continuing illicit opioid use, are effective indicators of dose inadequacy. There does not appear to be a maximum daily dose limit when determining what is adequately "enough" methadone in MMT.
Resumo:
BACKGROUND: We did a randomised phase 3 trial assessing the benefit of addition of long-term androgen suppression with a luteinising-hormone-releasing hormone (LHRH) agonist to external irradiation in patients with prostate cancer with high metastatic risk. In this report, we present the 10-year results. METHODS: For this open-label randomised trial, eligible patients were younger than 80 years and had newly diagnosed histologically proven T1-2 prostatic adenocarcinoma with WHO histological grade 3 or T3-4 prostatic adenocarcinoma of any histological grade, and a WHO performance status of 0-2. Patients were randomly assigned (1:1) to receive radiotherapy alone or radiotherapy plus immediate androgen suppression. Treatment allocation was open label and used a minimisation algorithm with institution, clinical stage of the disease, results of pelvic-lymph-node dissection, and irradiation fields extension as minimisation factors. Patients were irradiated externally, once a day, 5 days a week, for 7 weeks to a total dose of 50 Gy to the whole pelvis, with an additional 20 Gy to the prostate and seminal vesicles. The LHRH agonist, goserelin acetate (3·6 mg subcutaneously every 4 weeks), was started on the first day of irradiation and continued for 3 years; cyproterone acetate (50 mg orally three times a day) was given for 1 month starting a week before the first goserelin injection. The primary endpoint was clinical disease-free survival. Analysis was by intention to treat. The trial is registered at ClinicalTrials.gov, number NCT00849082. FINDINGS: Between May 22, 1987, and Oct 31, 1995, 415 patients were randomly assigned to treatment groups and were included in the analysis (208 radiotherapy alone, 207 combined treatment). Median follow-up was 9·1 years (IQR 5·1-12·6). 10-year clinical disease-free survival was 22·7% (95% CI 16·3-29·7) in the radiotherapy-alone group and 47·7% (39·0-56·0) in the combined treatment group (hazard ratio [HR] 0·42, 95% CI 0·33-0·55, p<0·0001). 10-year overall survival was 39·8% (95% CI 31·9-47·5) in patients receiving radiotherapy alone and 58·1% (49·2-66·0) in those allocated combined treatment (HR 0·60, 95% CI 0·45-0·80, p=0·0004), and 10-year prostate-cancer mortality was 30·4% (95% CI 23·2-37·5) and 10·3% (5·1-15·4), respectively (HR 0·38, 95% CI 0·24-0·60, p<0·0001). No significant difference in cardiovascular mortality was noted between treatment groups both in patients who had cardiovascular problems at study entry (eight of 53 patients in the combined treatment group had a cardiovascular-related cause of death vs 11 of 63 in the radiotherapy group; p=0·60) and in those who did not (14 of 154 vs six of 145; p=0·25). Two fractures were reported in patients allocated combined treatment. INTERPRETATION: In patients with prostate cancer with high metastatic risk, immediate androgen suppression with an LHRH agonist given during and for 3 years after external irradiation improves 10-year disease-free and overall survival without increasing late cardiovascular toxicity.
Resumo:
Lymph node cells derived from A.TH or A.TL mice primed with beef cytochrome c show striking patterns of reactivity when assayed in vitro for antigen-induced T cell proliferation. Whereas cells from A.TH mice respond specifically to beef cytochrome c or peptides composed of amino acids 1-65 and 81-104, cells from A.TL mice respond neither to beef cytochrome c nor to peptide 1-65, but proliferate following exposure to either peptide 81-104 or to a cytochrome c hybrid molecule in which the N-terminal peptide of beef (1-65) was substituted by a similar peptide obtained from rabbit cytochrome c. Thus, T cells from mice phenotypically unresponsive to beef cytochrome may, in fact, contain populations of lymphocytes capable of responding to a unique peptide, the response to which is totally inhibited when the same fragment is presented in the sequence of the intact protein.
Resumo:
Objective: To implement a carotid sparing protocol using helical Tomotherapy(HT) in T1N0 squamous-cell laryngeal carcinoma.Materials/Methods: Between July and August 2010, 7 men with stage T1N0 laryngeal carcinoma were included in this study. Age ranged from 47-74 years. Staging included endoscopic examination, CT-scan and MRI when indicated.Planned irradiation dose was 70 Gy in 35 fractions over 7 weeks. A simple treatment planning algorithm for carotidsparing was used: maximum point dose to the carotids 35 Gy, to the spinal cord 30 Gy, and 100% PTV volume to becovered with 95% of the prescribed dose. Carotid volume of interest extended to 1 cm above and below of the PTV.Doses to the carotid arteries, critical organs, and planned target volume (PTV) with our standard laryngealirradiation protocol was compared. Daily megavoltage scans were obtained before each fraction. When necessary, thePlanned Adaptive? software (TomoTherapy Inc., Madison, WI) was used to evaluate the need for a re-planning,which has never been indicated. Dose data were extracted using the VelocityAI software (Atlanta, GA), and datanormalization and dosevolume histogram (DVH) interpolation were realized using the Igor Pro software (Portland,OR).Results: A significant (p < 0.05) carotid dose sparing compared to our standard protocol with an average maximum point dose of 38.3 Gy (standard devaition [SD] 4.05 Gy), average mean dose of 18.59 Gy (SD 0.83 Gy) was achieved.In all patients, 95% of the carotid volume received less than 28.4 Gy (SD 0.98 Gy). The average maximum point doseto the spinal cord was 25.8 Gy (SD 3.24 Gy). PTV was fully covered with more than 95% of the prescribed dose forall patients with an average maximum point dose of 74.1 Gy and the absolute maximum dose in a single patient of75.2 Gy. To date, the clinical outcomes have been excellent. Three patients (42%) developed stage 1 mucositis that was conservatively managed, and all the patients presented a mild to moderate dysphonia. All adverse effectsresolved spontaneously in the month following the end of treatment. Early local control rate is 100% considering a 4-5months post treatment follow-up.Conclusions: HT allows a clinically significant decrease of carotid irradiation dose compared tostandard irradiation protocols with an acceptable spinal cord dose tradeoff. Moreover, this technique allows the PTV to be homogenously covered with a curative irradiation dose. Daily control imaging brings added security marginsespecially when working with high dose gradients. Further investigations and follow-up are underway to better evaluatethe late clinical outcomes especially the local control rate, late laryngeal and vascular toxicity, and expected potentialimpact on cerebrovascular events.
Resumo:
Lymphatic vessels transport fluid, antigens, and immune cells to the lymph nodes to orchestrate adaptive immunity and maintain peripheral tolerance. Lymphangiogenesis has been associated with inflammation, cancer metastasis, autoimmunity, tolerance and transplant rejection, and thus, targeted lymphatic ablation is a potential therapeutic strategy for treating or preventing such events. Here we define conditions that lead to specific and local closure of the lymphatic vasculature using photodynamic therapy (PDT). Lymphatic-specific PDT was performed by irradiation of the photosensitizer verteporfin that effectively accumulates within collecting lymphatic vessels after local intradermal injection. We found that anti-lymphatic PDT induced necrosis of endothelial cells and pericytes, which preceded the functional occlusion of lymphatic collectors. This was specific to lymphatic vessels at low verteporfin dose, while higher doses also affected local blood vessels. In contrast, light dose (fluence) did not affect blood vessel perfusion, but did affect regeneration time of occluded lymphatic vessels. Lymphatic vessels eventually regenerated by recanalization of blocked collectors, with a characteristic hyperplasia of peri-lymphatic smooth muscle cells. The restoration of lymphatic function occurred with minimal remodeling of non-lymphatic tissue. Thus, anti-lymphatic PDT allows control of lymphatic ablation and regeneration by alteration of light fluence and photosensitizer dose.