891 resultados para limits of visual detection


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ethyl carbamate (EC) is a common substance in fermented foods and drinks, and its quantification is important because of its carcinogenic nature and its usually presence in alcoholic beverages. The present work involved the development and validation of an analytical method for the evaluation of EC in cachaça by HPLC-FLD after previous derivatization with xanthydrol. The method presented a mean recovery of 94.88%, an intra-day precision of 4.19% (30.0 μg L−1) and 3.32% (75.0 μg L−1), a coefficient of determination (r2) equal to 0.9985, and limits of detection and quantification equal to 6.39 and 21.32 μg L−1, respectively. The results show that the analytical method is accurate, reproducible and linear over the concentration range from 5.0 to 160 μg of EC per litre. The method was applied to the analysis of EC in cachaça, the analyses being rapid and efficient.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Sugar is widely consumed worldwide and Brazil is the largest producer, consumer, and exporter of this product. To guarantee proper development and productivity of sugar cane crops, it is necessary to apply large quantities of agrochemicals, especially herbicides and pesticides. The herbicide tebuthiuron (TBH) prevents pre- and post-emergence of infesting weed in sugarcane cultures. Considering that it is important to ensure food safety for the population, this paper proposes a reliable method to analyse TBH in sugar matrixes (brown and crystal) using square wave voltammetry (SWV) and differential pulse voltammetry (DPV) at bare glassy carbon electrode and investigate the electrochemical behavior of this herbicide by cyclic voltammetry (CV). Our results suggest that TBH or the product of its reaction with a supporting electrolyte is oxidized through irreversible transfer of one electron between the analyte and the working electrode, at a potential close to +1.16 V vs. Ag |AgClsat in 0.10 mol L-1 KOH as supporting electrolyte solution. Both DPV and SWV are satisfactory for the quantitative analysis of the analyte. DPV is more sensitive and selective, with detection limits of 0.902, 0.815 and 0.578 mg kg-1, and quantification limits of 0.009, 0.010 and 0.008 mg kg-1 in the absence of the matrix and in the presence of crystal and brown sugar matrix, respectively. Repeatability lay between 0.53 and 13.8%, precision ranged between 4.14 and 15.0%, and recovery remained between 84.2 and 113% in the case of DPV conducted in the absence of matrix and in the presence of the crystal sugar matrix, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Procymidone, a potentially carcinogenic and mutagenic pesticide, can contribute to environmental and human contamination when applied to apple crops. In this work, we propose a reliable and sensitive method to determine procymidone in Brazilian apples. The method involves differential pulse (DPV) and square-wave voltammetry (SWV) techniques on a glassy carbon electrode. In a supporting electrolyte solution of 0.5 mol L−1 NaOH, procymidone undergoes an irreversible one-electron oxidation at +1.42 V by cyclic voltammetric vs. Ag|AgCl, KCl 3 M reference electrode. The proposed DPV and SWV methods have a good linear response in the 8.00–20.0 mg L−1 range, with limits of detection (LOD) of 0.678 and 0.228 mg L−1, respectively, in the absence of the matrix. We obtained improved LOD (0.097 mg L−1) in the presence of apple matrix and the supporting electrolyte solution. We used three commercial apple samples to evaluate recovery, and we achieved recovery percentages ranging from 94.6 to 110 % for procymidone determinations. We also tested the proposed voltammetric method for reproducibility, repeatability, and potential interferents, and the results were satisfactory for electroanalytical purposes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cachaça is a distiled beverage obtained from the fermentation of sugar cane syrup that, depending on the production procedures, may be susceptible to contamination by polycyclic aromatic hydrocarbons (PAHs). These compounds present carcinogenic and/or mutagenic properties and offer a risk to human health. Sixteen PAHs were determined in cachaças that had been stored in glass bottles and in polyethylene tank by gas chromatography coupled with mass spectrometry. The quantification of the PAHs utilised an internal standard. The limits of detection and quantification varied from 0.05 to 0.10 μg L−1 and 0.20 to 0.30 μg L−1, respectively. A total PAH concentration of 51.57 μg L−1 was found in the beverages that were stored in the tank, while the concentration in the cachaça stored in glass jugs was 6.07 μg L−1. These results indicate that the polyethylene tank is a source for PAHs in cachaça.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have developed an eletroanalytical method that employs Cu2+ solutions to determine arsenic in sugarcane brandy using an electrode consisting of carbon paste modified with carbon nanotubes (CNTPE) and polymeric resins. We used linear sweep (LSV) and differential-pulse (DPV) voltammetry with cathodic stripping for CNTPE containing mineral oil or silicone as binder. The analytical curves were linear from 30 to 110 μg L−1 and from 10 to 110 μg L−1 for LSV and DPV, respectively. The limits of detection (L.O.D.) and quantification (L.O.Q.) of CNTPE were 10.3 and 34.5 μg L−1 for mineral oil and 3.4 and 11.2 μg L−1 for silicone. We applied this method to determine arsenic in five commercial sugarcane brandy samples. The results agreed well with those obtained by hydride generation combined with atomic absorption spectrometry (HG AAS).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The presence of human papillomavirus (HPV) was evaluated in 65 samples of prostate tumours and six samples of prostates with benign prostatic hyperplasia from individuals from Northern Brazil. We used a highly sensitive test, the Linear Array HPV Genotyping Test, to detect 37 high and low-risk HPV types. In this study, only 3% of tumour samples showed HPV infection. Our findings support the conclusion that, despite the high incidence of HPV infection in the geographic regions studied, HPV was not associated with a higher risk of prostate cancer. To our knowledge, this is the first study evaluating the frequency of HPV detection in prostatic tissue of individuals from Brazil.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Metric features and modular and laminar distributions of intrinsic projections of area 17 were studied in Cebus apella. Anterogradely and retrogradely labeled cell appendages were obtained using both saturated pellets and iontophoretic injections of biocytin into the operculum. Laminar and modular distributions of the labeled processes were analyzed using Nissl counterstaining, and/or cytochrome oxidase and/or NADPH-diaphorase histochemistry. We distinguished three labeled cell types: pyramidal, star pyramidal and stellate cells located in supragranular cortical layers (principally in layers IIIa, IIIb α, IIIb ß and IIIc). Three distinct axon terminal morphologies were found, i.e., Ia, Ib and II located in granular and supragranular layers. Both complete and partial segregation of group I axon terminals relative to the limits of the blobs of V1 were found. The results are compatible with recent evidence of incomplete segregation of visual information flow in V1 of Old and New World primates.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Visual perception and action are strongly linked with parallel processing channels connecting the retina, the lateral geniculate nucleus, and the input layers of the primary visual cortex. Achromatic vision is provided by at least two of such channels formed by the M and P neurons. These cell pathways are similarly organized in primates having different lifestyles, including species that are diurnal, nocturnal, and which exhibit a variety of color vision phenotypes. We describe the M and P cell properties by 3D Gábor functions and their 3D Fourier transform. The M and P cells occupy different loci in the Gábor information diagram or Fourier Space. This separation allows the M and P pathways to transmit visual signals with distinct 6D joint entropy for space, spatial frequency, time, and temporal frequency. By combining the M and P impacts on the cortical neurons beyond V1 input layers, the cortical pathways are able to process aspects of visual stimuli with a better precision than it would be possible using the M or P pathway alone. This performance fulfils the requirements of different behavioral tasks.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study compared the effectiveness of the multifocal visual evoked cortical potentials (mfVEP) elicited by pattern pulse stimulation with that of pattern reversal in producing reliable responses (signal-to-noise ratio >1.359). Participants were 14 healthy subjects. Visual stimulation was obtained using a 60-sector dartboard display consisting of 6 concentric rings presented in either pulse or reversal mode. Each sector, consisting of 16 checks at 99% Michelson contrast and 80 cd/m2 mean luminance, was controlled by a binary m-sequence in the time domain. The signal-to-noise ratio was generally larger in the pattern reversal than in the pattern pulse mode. The number of reliable responses was similar in the central sectors for the two stimulation modes. At the periphery, pattern reversal showed a larger number of reliable responses. Pattern pulse stimuli performed similarly to pattern reversal stimuli to generate reliable waveforms in R1 and R2. The advantage of using both protocols to study mfVEP responses is their complementarity: in some patients, reliable waveforms in specific sectors may be obtained with only one of the two methods. The joint analysis of pattern reversal and pattern pulse stimuli increased the rate of reliability for central sectors by 7.14% in R1, 5.35% in R2, 4.76% in R3, 3.57% in R4, 2.97% in R5, and 1.78% in R6. From R1 to R4 the reliability to generate mfVEPs was above 70% when using both protocols. Thus, for a very high reliability and thorough examination of visual performance, it is recommended to use both stimulation protocols.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study evaluated the bioaccumulation of tributyltin (TBT) by the blue crab (Callinectes sapidus). Animals were fed with contaminated food containing 30 µg g-1 of TBT expressed as Sn. The analytes were determined in the gills, hepatopancreas and muscle. Acid digestion was used in the total Sn determination, and a solid-phase extraction technique was used for the selective determination of TBT. Limits of detection of 44.6 and 4.46 ng g-1 were found for HG-ICP OES (hydride generation-inductively coupled plasma optical emission spectroscopy) and ICP-MS (ICP-mass spectrometry), respectively. The results for non-contaminated animals were below 50 ng g-1, while the animals subjected to the contaminated food showed higher tissue concentrations of Sn (until 6229 ng g-1) and TBT (until 3357 ng g-1) related to the number of exposure days. According to the results, Sn is bioaccumulated by the blue crab in higher concentrations in the hepatopancreas. For most of these animals, the results suggest that Sn is bioaccumulated as TBT.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)