931 resultados para implant frameworks
Resumo:
A set of terms, definitions, and recommendations is provided for use in the classification of coordination polymers, networks, and metal–organic frameworks (MOFs). A hierarchical terminology is recommended in which the most general term is coordination polymer. Coordination networks are a subset of coordination polymers and MOFs a further subset of coordination networks. One of the criteria an MOF needs to fulfill is that it contains potential voids, but no physical measurements of porosity or other properties are demanded per se. The use of topology and topology descriptors to enhance the description of crystal structures of MOFs and 3D-coordination polymers is furthermore strongly recommended.
Resumo:
The construction industry is characterised by fragmentation and suffers from lack of collaboration, often adopting adversarial working practices to achieve deliverables. For the UK Government and construction industry, BIM is a game changer aiming to rectify this fragmentation and promote collaboration. However it has become clear that there is an essential need to have better controls and definitions of both data deliverables and data classification. Traditional methods and techniques for collating and inputting data have shown to be time consuming and provide little to improve or add value to the overall task of improving deliverables. Hence arose the need in the industry to develop a Digital Plan of Work (DPoW) toolkit that would aid the decision making process, providing the required control over the project workflows and data deliverables, and enabling better collaboration through transparency of need and delivery. The specification for the existing Digital Plan of Work (DPoW) was to be, an industry standard method of describing geometric, requirements and data deliveries at key stages of the project cycle, with the addition of a structured and standardised information classification system. However surveys and interviews conducted within this research indicate that the current DPoW resembles a digitised version of the pre-existing plans of work and does not push towards the data enriched decision-making abilities that advancements in technology now offer. A Digital Framework is not simply the digitisation of current or historic standard methods and procedures, it is a new intelligent driven digital system that uses new tools, processes, procedures and work flows to eradicate waste and increase efficiency. In addition to reporting on conducted surveys above, this research paper will present a theoretical investigation into usage of Intelligent Decision Support Systems within a digital plan of work framework. Furthermore this paper will present findings on the suitability to utilise advancements in intelligent decision-making system frameworks and Artificial Intelligence for a UK BIM Framework. This should form the foundations of decision-making for projects implemented at BIM level 2. The gap identified in this paper is that the current digital toolkit does not incorporate the intelligent characteristics available in other industries through advancements in technology and collation of vast amounts of data that a digital plan of work framework could have access to and begin to develop, learn and adapt for decision-making through the live interaction of project stakeholders.
Resumo:
The presence of a highly tunable porous structure and surface chemistry makes metal–organic framework (MOF) materials excellent candidates for artificial methane hydrate formation under mild temperature and pressure conditions (2 °C and 3–5 MPa). Experimental results using MOFs with a different pore structure and chemical nature (MIL-100 (Fe) and ZIF-8) clearly show that the water–framework interactions play a crucial role in defining the extent and nature of the gas hydrates formed. Whereas the hydrophobic MOF promotes methane hydrate formation with a high yield, the hydrophilic one does not. The formation of these methane hydrates on MOFs has been identified for the first time using inelastic neutron scattering (INS) and synchrotron X-ray powder diffraction (SXRPD). The results described in this work pave the way towards the design of new MOF structures able to promote artificial methane hydrate formation upon request (confined or non-confined) and under milder conditions than in nature.
Resumo:
La reconstruction en deux étapes par expanseur et implant est la technique la plus répandue pour la reconstruction mammmaire post mastectomie. La formation d’une capsule périprothétique est une réponse physiologique universelle à tout corps étranger présent dans le corps humain; par contre, la formation d’une capsule pathologique mène souvent à des complications et par conséquent à des résultats esthétiques sous-optimaux. Le microscope électronique à balayage (MEB) est un outil puissant qui permet d’effectuer une évaluation sans pareille de la topographie ultrastructurelle de spécimens. Le premier objectif de cette thèse est de comparer le MEB conventionnel (Hi-Vac) à une technologie plus récente, soit le MEB environnemental (ESEM), afin de déterminer si cette dernière mène à une évaluation supérieure des tissus capsulaires du sein. Le deuxième objectif est d‘appliquer la modalité de MEB supérieure et d’étudier les modifications ultrastructurelles des capsules périprothétiques chez les femmes subissant différents protocoles d’expansion de tissus dans le contexte de reconstruction mammaire prothétique. Deux études prospectives ont été réalisées afin de répondre à nos objectifs de recherche. Dix patientes ont été incluses dans la première, et 48 dans la seconde. La modalité Hi-Vac s’est avérée supérieure pour l’analyse compréhensive de tissus capsulaires mammaires. En employant le mode Hi-Vac dans notre protocole de recherche établi, un relief 3-D plus prononcé à été observé autour des expanseurs BIOCELL® dans le groupe d’approche d’intervention retardée (6 semaines). Des changements significatifs n’ont pas été observés au niveau des capsules SILTEX® dans les groupes d’approche d’intervention précoce (2 semaines) ni retardée.
Resumo:
Objective To provide 2-year clinical- and patient-oriented data with regard to mandibular overdenture assisted by 2 immediately loaded unsplinted implants. Material and methods In this pre-post design, Phase-I clinical trial, 18 edentate individuals (62.4 ± 7.7 years) received a new set of complete denture. Then, following standard procedures, 3 threaded implants (OsseoSpeed TX™, Dentsply Implants, Mölndal, Sweden) were placed in the mandible in each patient, and locator abutments (Zest Anchors LLC, Escondido, U.S.A.) were inserted on the right and left side implants. The midline implant served as a control for within-patient comparison. The immediate loading was conducted within 24 h of surgery. Data were collected at baseline (T0), 12 (T1) and 24 (T2) months after immediate loading. The clinical outcomes included implant survival rate, crestal bone level changes and implant stability. These criteria were assessed through clinical and radiographic examinations as well as resonance frequency analysis. Patient-centered outcomes included patient satisfaction and oral health-related quality of life measured using validated questionnaires. Brunner-Langer approach was used for statistical analysis. Results Implant survival rate for immediate loaded implants was 91.7% at 2-year follow-up. None of the unloaded implants failed. There was no statistically significant difference at baseline and follow-ups with regard to clinical outcomes between loaded and unloaded implants. Patient satisfaction and quality of life improved (p < 0.0001) from baseline to 2-year follow-up. Conclusion Immediate loading protocol did not negatively affect clinical outcomes, satisfaction and quality of life of patients wearing 2-unsplinted-implant mandibular overdenture for 2 years. This conclusion requires confirmation by randomized control trials. Clinical significance statement Mandibular overdenture assisted by two immediately-loaded unsplinted implants is successful treatment based on 2-year clinical and patient-based outcomes.
Resumo:
Poster presented at the 1st International Congress of CiiEM - From Basic Sciences to Clinical Research. 27-28 November 2015, Egas Moniz, Caparica, Portugal.
Resumo:
Poster presented at the 1st International Congress of CiiEM - From Basic Sciences to Clinical Research, 27-28 November 2015, Egas Moniz, Caparica, Portugal.
Resumo:
This briefing is an input to the discussions that will take place in the session “Privacy under mass surveillance: a multi-stakeholder international challenge” to be held on November 9th in João Pessoa, Brazil, during the “Day Zero” of the Internet Governance Forum. This document is one of the outputs of the first phase of the project “Privacy in the digital age: fostering the implementation of the bilateral German-Brazilian strategy in response to massive data collection”, jointly developed by the Center for Technology and Society of the Rio de Janeiro Law School of the Getulio Vargas Foundation and the German Institute for International and Security Affairs (SWP), with the support of FGV. The project Privacy in the Digital Age seeks to identify legal, political, technical, and economic incentives for the implementation of resolution 168/67 on Privacy in the Digital Age, proposed by Germany and Brazil, and approved by the United Nations General Assembly and to identify other potential areas of collaboration between Germany and Brazil in the field of Internet Governance.
Resumo:
Objective To provide 2-year clinical- and patient-oriented data with regard to mandibular overdenture assisted by 2 immediately loaded unsplinted implants. Material and methods In this pre-post design, Phase-I clinical trial, 18 edentate individuals (62.4 ± 7.7 years) received a new set of complete denture. Then, following standard procedures, 3 threaded implants (OsseoSpeed TX™, Dentsply Implants, Mölndal, Sweden) were placed in the mandible in each patient, and locator abutments (Zest Anchors LLC, Escondido, U.S.A.) were inserted on the right and left side implants. The midline implant served as a control for within-patient comparison. The immediate loading was conducted within 24 h of surgery. Data were collected at baseline (T0), 12 (T1) and 24 (T2) months after immediate loading. The clinical outcomes included implant survival rate, crestal bone level changes and implant stability. These criteria were assessed through clinical and radiographic examinations as well as resonance frequency analysis. Patient-centered outcomes included patient satisfaction and oral health-related quality of life measured using validated questionnaires. Brunner-Langer approach was used for statistical analysis. Results Implant survival rate for immediate loaded implants was 91.7% at 2-year follow-up. None of the unloaded implants failed. There was no statistically significant difference at baseline and follow-ups with regard to clinical outcomes between loaded and unloaded implants. Patient satisfaction and quality of life improved (p < 0.0001) from baseline to 2-year follow-up. Conclusion Immediate loading protocol did not negatively affect clinical outcomes, satisfaction and quality of life of patients wearing 2-unsplinted-implant mandibular overdenture for 2 years. This conclusion requires confirmation by randomized control trials. Clinical significance statement Mandibular overdenture assisted by two immediately-loaded unsplinted implants is successful treatment based on 2-year clinical and patient-based outcomes.
Resumo:
"BNL-NUREG-51419."
Resumo:
Mode of access: Internet.
Resumo:
Mode of access: Internet.