903 resultados para force majeure


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to analyze central motor output changes in relation to contraction force during motor fatigue. The triple stimulation technique (TST, Magistris et al. in Brain 121(Pt 3):437-450, 1998) was used to quantify a central conduction index (CCI = amplitude ratio of central conduction response and peripheral nerve response, obtained simultaneously by the TST). The CCI removes effects of peripheral fatigue from the quantification. It allows a quantification of the percentage of the entire target muscle motor unit pool driven to discharge by a transcranial magnetic stimulus. Subjects (n = 23) performed repetitive maximal voluntary contractions (MVC) of abductor digiti minimi (duration 1 s, frequency 0.5 Hz) during 2 min. TST recordings were obtained every 15 s, using stimulation intensities sufficient to stimulate all cortical motor neurons (MNs) leading to the target muscle, and during voluntary contractions of 20% of the MVC to facilitate the responses. TST was also repetitively recorded during recovery. This basic exercise protocol was modified in a number of experiments to further characterize influences on CCI of motor fatigue (4 min exercise at 50% MVC; delayed fatigue recovery during local hemostasis, "stimulated exercise" by 20 Hz trains of 1 s duration at 0.5 Hz during 2 min). In addition, the cortical silent period was measured during the basic exercise protocol. Force fatigued to approximately 40% of MVC in all experiments and in all subjects. In all subjects, CCI decreased during exercise, but this decrease varied markedly between subjects. On average, CCI reductions preceded force reductions during exercise, and CCI recovery preceded force recovery. Exercising at 50% for 4 min reduced muscle force more markedly than CCI. Hemostasis induced by a cuff delayed muscle force recovery, but not CCI recovery. Stimulated exercise reduced force markedly, but CCI decreased only marginally. Summarized, force reduction and reduction of the CCI related poorly quantitatively and in time, and voluntary drive was particularly critical to reduce the CCI. The fatigue induced reduction of CCI may result from a central inhibitory phenomenon. Voluntary muscle activation is critical for the CCI reduction, suggesting a primarily supraspinal mechanism.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Wear of attachments leads to a loss of retention and potentially reduces the function of complete dentures. This study evaluated the retention force changes of different prefabricated attachment systems for implant-supported overdentures to estimate the wear constancy and applicability in clinical practice. METHODS: Four prefabricated attachment systems were tested [Group SG: retentive ball attachment (Straumann, Switzerland) with gold matrix, Group ST: retentive ball attachment (Straumann, Switzerland) with titanium spring matrix, Group IB: UNOR i-Ball with Ecco matrix (UNOR, Switzerland) and Group IMZ: IMZ-TwinPlus ball attachment with gold matrix (DENTSPLY Friadent, Germany)]. Ten samples of each system were subjected to 10,000 insertion-separation cycles. RESULTS: Results showed that all types of attachments showed wear, which led to a loss of retention force after an initial increase at the beginning of the wear simulation. Attachments with a plastic retention insert or gold matrices underwent the smallest changes in retention force. The titanium spring system showed the largest changes in retention force and a greater variation between the different cycles and specimen. This behaviour is probably caused by a large fitting tolerance of the titanium spring. CONCLUSIONS: Attachment systems which possess a male and female component of different material composition are preferable. They show smaller changes in the retention force. For retention force increase and wear compensation, an attachment system should be adjustable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article reports the most recent work of the OMERACT Ultrasound Task Force (post OMERACT 8) and highlights of future research priorities discussed at the OMERACT 9 meeting, Kananaskis, Canada, May 2008. Results of 3 studies were presented: (1) assessing intermachine reliability; (2) applying the scoring system developed in the hand to other joints most commonly affected in rheumatoid arthritis (RA); and (3) assessing interobserver reliability on a deep target joint (shoulder). Results demonstrated good intermachine reliability between multiple examiners, and good applicability of the scoring system for the hand on other joints (including shoulder). Study conclusions were discussed and a future research agenda was generated, notably the further development of a Global OMERACT Sonography Scoring (GLOSS) system in RA, emphasizing the importance of testing feasibility and added value over standard clinical variables. Future disease areas of importance to develop include a scoring system for enthesitis and osteoarthritis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Insulated atomic force microscopy probes carrying gold conductive tips were fabricated and employed as bifunctional force and current sensors in electrolyte solutions under electrochemical potential control. The application of the probes for current-sensing imaging, force and current–distance spectroscopy as well as scanning electrochemical microscopy experiments was demonstrated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the action items arising from the work of the Campus Climate Implementation Team and the President’s Advisory Committee on Diversity was a request from the President to the Provost to review the Dialogues on Diversity course. The Provost instructed this Task Force to review the current Dialogues on Diversity course to determine how it should be continued for optimal impact and to determine whether it is appropriate to add a “Dialogues—Part 2” to the curriculum. The Provost’s charge to the Task Force also asked for recommendations that include details on the following components of the current program: goals and objectives of the revised course administration and recommended department home for the revised course possibility of and need for a second course optimal coordination with other programs/initiatives on campus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Contact force (CF) is an important determinant of lesion formation for atrial endocardial radiofrequency ablation. There are minimal published data on CF and ventricular lesion formation. We studied the impact of CF on lesion formation using an ovine model both endocardially and epicardially. METHODS AND RESULTS Twenty sheep received 160 epicardial and 160 endocardial ventricular radiofrequency applications using either a 3.5-mm irrigated-tip catheter (Thermocool, Biosense-Webster, n=160) or a 3.5 irrigated-tip catheter with CF assessment (Tacticath, Endosense, n=160), via percutaneous access. Power was delivered at 30 watts for 60 seconds, when either catheter/tissue contact was felt to be good or when CF>10 g with Tacticath. After completion of all lesions, acute dimensions were taken at pathology. Identifiable lesion formation from radiofrequency application was improved with the aid of CF information, from 78% to 98% on the endocardium (P<0.001) and from 90% to 100% on the epicardium (P=0.02). The mean total force was greater on the endocardium (39±18 g versus 21±14 g for the epicardium; P<0.001) mainly because of axial force. Despite the force-time integral being greater endocardially, epicardial lesions were larger (231±182 mm(3) versus 209±131 mm(3); P=0.02) probably because of the absence of the heat sink effect of the circulating blood and covered a greater area (41±27 mm(2) versus 29±17 mm(2); P=0.03) because of catheter orientation. CONCLUSIONS In the absence of CF feedback, 22% of endocardial radiofrequency applications that are thought to have good contact did not result in lesion formation. Epicardial ablation is associated with larger lesions.