981 resultados para flow over bottom topography


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Perennial rye-grass was subjected to two different14C labelling regimes to enable a partitioning of the carbon sources contributing to rhizosphere carbon-flow. Plant/soil microcosms were designed which enabled rye-grass plants to either receive a single pulse of14C-CO2 or to be pre-labelled using a series of14C-CO2 pulses, allowing the fate of newly photoassimilated carbon and carbon lost by root decomposition to be followed into the soil. For young rye-grass plants grown over a short period, rhizosphere carbon flow was found to be dominated by newly photoassimilated carbon. Evidence for this came from the observed percentage of the total14C budget (i.e. total14C-CO2 fixed by the plants) lost from the root/soil system, which was 30 times greater for the pulse labelled compared to pre-labelled plants. Root decomposition was found to be less at 10°C compared to 20-25°C, though input of14C into the soil was the same at both temperatures. © 1988 Kluwer Academic Publishers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes an investigation of various shroud bleed slot configurations of a centrifugal compressor using CFD with a manual multi-block structured grid generation method. The compressor under investigation is used in a turbocharger application for a heavy duty diesel engine of approximately 400hp. The baseline numerical model has been developed and validated against experimental performance measurements. The influence of the bleed slot flow field on a range of operating conditions between surge and choke has been analysed in detail. The impact of the returning bleed flow on the incidence at the impeller blade leading edge due to its mixing with the main through-flow has also been studied. From the baseline geometry, a number of modifications to the bleed slot width have been proposed, and a detailed comparison of the flow characteristics performed. The impact of slot variations on the inlet incidence angle has been investigated, highlighting the improvement in surge and choked flow capability. Along with this, the influence of the bleed slot on stabilizing the blade passage flow by the suction of the tip and over-tip vortex flow by the slot has been considered near surge.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Flow processing is a fundamental element of stateful traffic classification and it has been recognized as an essential factor for delivering today’s application-aware network operations and security services. The basic function within a flow processing engine is to search and maintain a flow table, create new flow entries if no entry matches and associate each entry with flow states and actions for future queries. Network state information on a per-flow basis must be managed in an efficient way to enable Ethernet frame transmissions at 40 Gbit/s (Gbps) and 100 Gbps in the near future. This paper presents a hardware solution of flow state management for implementing large-scale flow tables on popular computer memories using DDR3 SDRAMs. Working with a dedicated flow lookup table at over 90 million lookups per second, the proposed system is able to manage 512-bit state information at run time.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Glazed Double Skin Facades (DSF) offer the potential to improve the performance of all-glass building skins, common to commercial office buildings in which full facade glazing has almost become the standard. Single skin glazing results in increased heating and cooling costs over opaque walls, due to lower thermal resistance of glass, and the increased impact of solar gain through it. However, the performance benefit of DSF technology continues to be questioned and its operation poorly understood, particularly the nature of airflow through the cavity. This paper deals specifically with the experimental analysis of the air flow characteristics in an automated double skin façade. The benefit of the DSF as a thermal buffer, and to limit overheating is evaluated through analysis of an extensive set of parameters including air and surface temperatures at each level in the DSF, airflow readings in the cavity and at the inlet and outlet, solar and wind data, and analytically derived pressure differentials. The temperature and air-flow are monitored in the cavity of a DSF using wireless sensors and hot wire anemometers respectively. Automated louvre operation and building set-points are monitored via the BMS. Thermal stratification and air flow variation during changing weather conditions are shown to effect the performance of the DSF considerably and hence the energy performance of the building. The relative pressure effects due to buoyancy and wind are analysed and quantified. This research aims to developed and validate models of DSFs in the maritime climate, using multi-season data from experimental monitoring. This extensive experimental study provides data for training and validation of models.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Static timing analysis provides the basis for setting the clock period of a microprocessor core, based on its worst-case critical path. However, depending on the design, this critical path is not always excited and therefore dynamic timing margins exist that can theoretically be exploited for the benefit of better speed or lower power consumption (through voltage scaling). This paper introduces predictive instruction-based dynamic clock adjustment as a technique to trim dynamic timing margins in pipelined microprocessors. To this end, we exploit the different timing requirements for individual instructions during the dynamically varying program execution flow without the need for complex circuit-level measures to detect and correct timing violations. We provide a design flow to extract the dynamic timing information for the design using post-layout dynamic timing analysis and we integrate the results into a custom cycle-accurate simulator. This simulator allows annotation of individual instructions with their impact on timing (in each pipeline stage) and rapidly derives the overall code execution time for complex benchmarks. The design methodology is illustrated at the microarchitecture level, demonstrating the performance and power gains possible on a 6-stage OpenRISC in-order general purpose processor core in a 28nm CMOS technology. We show that employing instruction-dependent dynamic clock adjustment leads on average to an increase in operating speed by 38% or to a reduction in power consumption by 24%, compared to traditional synchronous clocking, which at all times has to respect the worst-case timing identified through static timing analysis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The market for table grapes is moving into mass production of specialty seed-less grapes in covered areas, aiming at obtaining premium prices with early or late production of high quality products. Production of quality seedless grapes is not straightforward since it is requires the correct combination of various independent characteristics, such as color, sugars, size and quantity at the right moment for successful harvesting and marketing. The present study was carried out at the two largest Portuguese producers located in Alentejo, and has the objective of studying the effect of irrigation management strategies and two different soils on the various relevant parameters for successful production and marketing. The management strategies were the application of ten day stress at the end of the cycle, in order to promote early maturing of the grapes. Three different timings of the stress were applied. Soil moisture, sap flow, bark thickness, as well as leaf water potential, stomatal conductance and chlorophyll content were measured regularly during the production season. The results indicate that the roots explore a rather large soil volume and the plants can successfully withstand reasonable periods of drought without significant changes to the plant physiology. Additionally late rains can mask the effect of any farmer applied drought and invalidate any farmer induced stress to the plants. Water-logged soils tend to cause early onset of maturity, but cause the ripening stage to extend over a longer period of time, and thus, in effect result in a delay in the harvest date. Topography also has some effect on the ripening, since hot air tends to accumulate under the plastic at the higher areas of the field. This work is funded by PRODER, 4.1, within the scope of project MORECRIMSON

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article examines prison education in England and Wales arguing that a disjuncture exists between the policy rhetoric of entitlement to education in prison at the European level and the playing out of that entitlement in English and Welsh prisons. Caught between conflicting discourses around a need to combat recidivism and a need for incarceration, prison education in England exists within a policy context informed, in part, by an international human rights agenda on the one hand and global recession, financial cutbacks, and a moral panic about crime on the other. The European Commission has highlighted a number of challenges facing prison education in Europe including over‐crowded institutions, increasing diversity in prison populations, the need to keep pace with pedagogical changes in mainstream education and the adoption of new technologies for learning (Hawley et al., 2013). These are challenges confronting all policy makers involved in prison education in England and Wales in a policy context that is messy, contradictory and fiercely contested. The article argues that this policy context, exacerbated by socio‐economic discourses around neo‐liberalism, is leading to a race‐to‐the‐bottom in the standards of educational provision for prisoners in England and Wales.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nowadays, vector sensors which measure both acoustic pressure and particle velocity begin to be available in underwater acoustic systems, normally configured as vector sensor arrays (VSA). The spatial filtering capabilities of a VSA can be used, with advantage over traditional pressure only hydrophone arrays, for estimating acoustic field directionality as well as arrival times and spectral content, which could open up the possibility for its use in bottom properties' estimation. An additional motivation for this work is to test the possibility of using high frequency probe signals (say above 2 kHz) for reducing size and cost of actual sub bottom profilers and current geoacoustic inversion methods. This work studies the bottom related structure of the VSA acquired signals, regarding the emitted signal waveform, frequency band and source-receiver geometry in order to estimate bottom properties, specially bottom reflection coefficient characteristics. Such a system was used during the Makai 2005 experiment, off Kauai I., Hawai (USA) to receive precoded signals in a broad frequency band from 8 up to 14 kHz. The agreement between the observed and the modelled acoustic data is discussed and preliminary results on the bottom reflection estimation are presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Tese dout., Ciências do Mar (Ecologia Marinha), Faculdade de Ciências e Tecnologia, Univ. do Algarve, 2010

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Tese de doutoramento, Geografia (Geografia Física), Universidade de Lisboa, Instituto de Geografia e Ordenamento do Território, 2014

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Thesis (Ph.D.)--University of Washington, 2014

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The reduction of luvastatin (FLV) at a hanging mercury-drop electrode (HMDE) was studied by square-wave adsorptive-stripping voltammetry (SWAdSV). FLV can be accumulated and reduced at the electrode, with a maximum peak current intensity at a potential of approximately 1.26V vs. AgCl=Ag, in an aqueous electrolyte solution of pH 5.25. The method shows linearity between peak current intensity and FLV concentration between 1.0 10 8 and 2.7 10 6 mol L 1. Limits of detection (LOD) and quantification (LOQ) were found to be 9.9 10 9 mol L 1 and 3.3 10 8 mol L 1, respectively. Furthermore, FLV oxidation at a glassy carbon electrode surface was used for its hydrodynamic monitoring by amperometric detection in a flow-injection system. The amperometric signal was linear with FLV concentration over the range 1.0 10 6 to 1.0 10 5 mol L 1, with an LOD of 2.4 10 7 mol L 1 and an LOQ of 8.0 10 7 mol L 1. A sample rate of 50 injections per hour was achieved. Both methods were validated and showed to be precise and accurate, being satisfactorily applied to the determination of FLV in a commercial pharmaceutical.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To assess the variability of the response to exogenous atrial natriuretic peptide (ANP), it was infused at the rate of 1 microgram/min for 2 h in 6 salt-loaded normal volunteers under controlled conditions on 2 occasions at an interval of 1 week. The effect on solute excretion and the haemodynamic and endocrine actions were highly reproducible. The constant ANP infusion caused a delayed and prolonged excretion of sodium, chloride and calcium, no change in potassium or phosphate excretion or in glomerular filtration rate but a marked decrease in renal plasma flow. Blood pressure, heart rate and the plasma levels of angiotensin II, aldosterone, arginine vasopressin and plasma renin activity were unaltered. The effect of a 2-h infusion of ANP 0.5 microgram/min or its vehicle on apparent hepatic blood flow (HBF) was also studied in 14 normal volunteers by measuring the indocyanine green clearance. A 21% decrease in HBF was observed in subjects who received the ANP infusion (p less than 0.01 vs vehicle). Thus, ANP infused at a dose that did not lower blood pressure decreased both renal and liver blood flow in normotensive volunteers. The renal and endocrine responses to ANP were reproducible over a 1-week interval.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Crawford Lake is a meromictic lake, which is 24 m deep and has an area of 2.5 ha, and has never been reported to have mixed below 16 m. Lady Evelyn Lake, which became a reservoir when a dam was built in 1916, is dimictic with a maximum depth of about 35 m. 1 My research proved that both native chlorophylls and the ratio of chlorophyll derivatives to total carotenoids were better preserved in the shallower lake (Crawford Lake) because it was meromictic. Thus the anaerobic conditions in Crawford Lake below 16 m (monimolimnion) provide excellent conditions for pigment preservation. Under such conditions, the preservation of both chlorophylls and carotenoids, including oscillaxanthin and myxoxanthophyll, are extremely good compared with those of Lady Evelyn Reservoir, in which anaerobic conditions are rarely encountered at the mud-water interface. During the period from 1500 to 1900 A. D. in Crawford Lake, the accumulation rates of oscillaxanthin and myxoxanthophyll were extremely high, but those of chlorophyll derivatives and total carotenoids were relatively low. This was correlated with the presence of a dense benthic mat of cyanobacteria near the lake's chemocline. Competition for light between the deep dwelling cyanobacteria and overlying phytoplankton in this meromictic lake would have been intensified as the lake became more and more eutrophic (1955-1991 A. D.). During the period from 1955 to 1991 A. D., the accumulation rates of chlorophyll derivatives and total carotenoids in the sediment core from Crawford Lake (0-7.5 cm, 1955-present) increased. During this same period, the accumulation rates of cyanobacterial pigments (Le. oscillaxanthin and myxoxanthophyll) declined as the lake became more eutrophic. Because the major cyanobacteria in Crawford Lake are benthic mat forming Lyngbya and Oscillatoria and not phytoplankton, eutrophication resulted in a decline of the mat forming algal pigments. This is important because in previous palaeolimnological studies the concentrations of oscillaxanthin and myxoxanthophyll have been used as correlates with lake trophic levels. The results of organic carbon a13c analysis on the Crawford Lake sediment core supported the conclusions from the pigment study as noted above. High values of a13c at the depth of 34-48 cm (1500-1760 A. D.) were related to a dense population of benthic Oscillatoria and Lyngbya living on the bottom of the lake during that period. The Oscillatoria and Lyngbya utilized the bicarbonate, which had a high a 13C value. Very low values were found at 0-7 cm in the Crawford sediment core. At this time phytoplankton was the main primary producer, which enriched 12C by photosynthetic assimilation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Flow injection analysis (FIA) was applied to the determination of both chloride ion and mercury in water. Conventional FIA was employed for the chloride study. Investigations of the Fe3 +/Hg(SCN)2/CI-,450 nm spectrophotometric system for chloride determination led to the discovery of an absorbance in the 250-260 nm region when Hg(SCN)2 and CI- are combined in solution, in the absence of iron(III). Employing an in-house FIA system, absorbance observed at 254 nm exhibited a linear relation from essentially 0 - 2000 Jlg ml- 1 injected chloride. This linear range spanning three orders of magnitude is superior to the Fe3+/Hg(SCN)2/CI- system currently employed by laboratories worldwide. The detection limit obtainable with the proposed method was determin~d to be 0.16 Jlg ml- 1 and the relative standard deviation was determined to be 3.5 % over the concentration range of 0-200 Jig ml- 1. Other halogen ions were found to interfere with chloride determination at 254 nm whereas cations did not interfere. This system was successfully applied to the determination of chloride ion in laboratory water. Sequential injection (SI)-FIA was employed for mercury determination in water with the PSA Galahad mercury amalgamation, and Merlin mercury fluorescence detection systems. Initial mercury in air determinations involved injections of mercury saturated air directly into the Galahad whereas mercury in water determinations involved solution delivery via peristaltic pump to a gas/liquid separator, after reduction by stannous chloride. A series of changes were made to the internal hardware and valving systems of the Galahad mercury preconcentrator. Sequential injection solution delivery replaced the continuous peristaltic pump system and computer control was implemented to control and integrate all aspects of solution delivery, sample preconcentration and signal processing. Detection limits currently obtainable with this system are 0.1 ng ml-1 HgO.