875 resultados para flexible portal frame


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The verification possibilities of dynamically collimated treatment beams with a scanning liquid ionization chamber electronic portal image device (SLIC-EPID) are investigated. The ion concentration in the liquid of a SLIC-EPID and therefore the read-out signal is determined by two parameters of a differential equation describing the creation and recombination of the ions. Due to the form of this equation, the portal image detector describes a nonlinear dynamic system with memory. In this work, the parameters of the differential equation were experimentally determined for the particular chamber in use and for an incident open 6 MV photon beam. The mathematical description of the ion concentration was then used to predict portal images of intensity-modulated photon beams produced by a dynamic delivery technique, the sliding window approach. Due to the nature of the differential equation, a mathematical condition for 'reliable leaf motion verification' in the sliding window technique can be formulated. It is shown that the time constants for both formation and decay of the equilibrium concentration in the chamber is in the order of seconds. In order to guarantee reliable leaf motion verification, these time constants impose a constraint on the rapidity of the image-read out for a given maximum leaf speed. For a leaf speed of 2 cm s(-1), a minimum image acquisition frequency of about 2 Hz is required. Current SLIC-EPID systems are usually too slow since they need about a second to acquire a portal image. However, if the condition is fulfilled, the memory property of the system can be used to reconstruct the leaf motion. It is shown that a simple edge detecting algorithm can be employed to determine the leaf positions. The method is also very robust against image noise.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Today electronic portal imaging devices (EPID's) are used primarily to verify patient positioning. They have, however, also the potential as 2D-dosimeters and could be used as such for transit dosimetry or dose reconstruction. It has been proven that such devices, especially liquid filled ionization chambers, have a stable dose response relationship which can be described in terms of the physical properties of the EPID and the pulsed linac radiation. For absolute dosimetry however, an accurate method of calibration to an absolute dose is needed. In this work, we concentrate on calibration against dose in a homogeneous water phantom. Using a Monte Carlo model of the detector we calculated dose spread kernels in units of absolute dose per incident energy fluence and compared them to calculated dose spread kernels in water at different depths. The energy of the incident pencil beams varied between 0.5 and 18 MeV. At the depth of dose maximum in water for a 6 MV beam (1.5 cm) and for a 18 MV beam (3.0 cm) we observed large absolute differences between water and detector dose above an incident energy of 4 MeV but only small relative differences in the most frequent energy range of the beam energy spectra. It is shown that for a 6 MV beam the absolute reference dose measured at 1.5 cm water depth differs from the absolute detector dose by 3.8%. At depth 1.2 cm in water, however, the relative dose differences are almost constant between 2 and 6 MeV. The effects of changes in the energy spectrum of the beam on the dose responses in water and in the detector are also investigated. We show that differences larger than 2% can occur for different beam qualities of the incident photon beam behind water slabs of different thicknesses. It is therefore concluded that for high-precision dosimetry such effects have to be taken into account. Nevertheless, the precise information about the dose response of the detector provided in this Monte Carlo study forms the basis of extracting directly the basic radiometric quantities photon fluence and photon energy fluence from the detector's signal using a deconvolution algorithm. The results are therefore promising for future application in absolute transit dosimetry and absolute dose reconstruction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The use of conventional implants for intramedullary nailing of humeral shaft fractures is associated with specific difficulties. During antegrade implantation structures of the rotator cuff can be affected leading to a reduced functional result of the shoulder. If the nail is implanted in a retrograde manner problems arise due to a relatively large hole close to or within the olecranon fossa, which is necessary for insertion of the nail. Supracondylar fractures as well as persistent elbow pain and loss of function are reported in the literature. To overcome these disadvantages a flexible nail has been developed that can be stiffened and locked after implantation. METHOD: Between October 2000 and February 2002, 34 patients were treated with the flexible nail at our institution; 29 were available for follow-up. Fracture healing was documented on radiographs and clinical outcome was evaluated with use of the Constant as well as the Kwasny score. RESULTS: Median duration until fracture consolidation was 10 weeks. In two patients fracture union was not achieved within the follow-up period. The median outcome measured with the Constant score was 93 points and 2.5 with the Kwasny score. Both values correspond to a very good functional outcome. CONCLUSION: We conclude that the flexible humeral nail is an excellent treatment option for humeral shaft fractures. Damage to the rotator cuff and the distal humerus can be avoided due to its unique flexible construction, improving the functional outcome of intramedullary nailing for the treatment of humeral shaft fractures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND/AIMS: It is postulated that nitric oxide (NO) is responsible for the hyperdynamic circulation of portal hypertension. Therefore, we investigated induction of fibrosis and hyperdynamic circulation in endothelial NO synthase knock-out (KO) mice. METHODS: Fibrosis was induced by bile duct ligation. Hemodynamic studies were performed after portal vein ligation. All studies were performed in wild-type (WT) and KO mice. RESULTS: Three to 4 weeks after bile duct ligation (BDL), both WT and KO groups had similar degrees of portal hypertension, 12 (9-14) and 11(8-15) mmHg, median (range), and liver function. Fibrosis increased from 0.0% in sham operated to 1.0 and 1.1% in WT and KO mice, respectively. Cardiac output was similar after portal vein ligation (20 and 17 ml/min in WT and KO mice, respectively). There was no difference in liver of mRNA for endothelin 1, inducible NO synthase (iNOS) and hem-oxygenase 1 (HO1); proteins of iNOS, HO1 and HO2; nor in endothelin A and B (EtA and EtB) receptor density between WT and KO mice after BDL. CONCLUSIONS: These results suggest that endothelial NO synthase is neither essential for the development of fibrosis and portal hypertension in bile duct ligated mice, nor for the hyperdynamic circulation associated with portal hypertension in the portal vein ligated mice.