876 resultados para essence of operation
Resumo:
The present work consists in the analysis of tribologycal properties of basic and multifunctional knitted fabrics. This knowledge has fundamental importance for the textile industry since it can quantify, in an objective way, the tactil. The fabrics used were characterized by friction and mechanical tests for determining the viscoelastic region, wear resistance and friction coefficient of the fabrics used. The stress-strain curve was obtained by the method Kawabata, KES-FB1. Wear tests performed with the aid of equipment Martindale. The measurement of friction coefficient, two methods were used and analyzed comparatively. The first was a method already established worldwide known as KES-FB4 and the second was an innovative method called FRICTORQ, developed by the University of Minho. These two methods were compared taking into account the relative motion between the tribologycal pairs are different from each method. While the first motion is translational, the second is rotational. It was formal that the knitted had a multifunctional fabrics tribologycal performance which was better than the basic knitted fabrics, as the viscoelastic region, was laager highlighting a multifunctional structure, with greater wear resistance mainly on the back side of the knitted fabrics and lower friction coefficient. Performing a comparative analysis between two methods used to measure the friction coefficient, it was formal that both methods were consistent in terms of results. In operational terms, the FRICTORQ showed ease of operation and increased reproducibility of results
Resumo:
We studied the feasibility of using a system of Solar Water Heating (SAS) with low cost, for three configurations. In configurations I and II have the collector grid absorber composed of six PVC tubes placed in parallel on the tile cement. In configuration II, the PVC tubes were transparent cover made of plastic bottles. Configuration III uses a collector composed of 12 black HDPE pipes, supported on four cement tiles 2.44 m x 0.50 m, two by two overlapping and interspersed with a filling of glass wool, comprising an area exposed to the global radiation incident of 2.44 m2, with the top two tiles painted matte black. In this configuration, the HDPE pipes replace conventional PVC pipes painted black. The total cost of SAS for configuration III, the most economical, was around $ 150.00. For the configurations tested the system of operation was thermosyphon collector. The study showed that the proposed systems have good thermal efficiency, are easy to install and handle and have low cost compared to conventional.
Resumo:
Low voltage solar panels increase the reliability of solar panels due to reduction of in series associations the configurations of photovoltaic cells. The low voltage generation requires DCDC converters devices with high efficiency, enabling raise and regulate the output voltage. This study analyzes the performance of a photovoltaic panel of Solarex, MSX model 77, configured to generate an open circuit voltage of 10.5 V, with load voltage of 8.5 V, with short circuit current of 9 A and a power of 77 W. The solar panel was assembled in the isolated photovoltaic system configuration, with and without energy storage as an interface with a DCDC converter, Booster topology. The converter was designed and fabricated using SMD (Surface Mounted Devices) technology IC (integrated circuit) that regulates its output voltage at 14.2 V, with an efficiency of 87% and providing the load a maximum power of 20.88 W. The system was installed and instrumented for measurement and acquisition of the following data: luminosities, average global radiation (data of INPE Instituto Nacional de Pesquisas Espaciais), solar panel and environment temperatures, solar panel and DC-DC converter output voltages, panel, inverter, and battery charge output currents. The photovoltaic system was initially tested in the laboratory (simulating its functioning in ideal conditions of operation) and then subjected to testing in real field conditions. The panel inclination angle was set at 5.5°, consistent with the latitude of Natal city. Factors such as climatic conditions (simultaneous variations of temperature, solar luminosities and ra diation on the panel), values of load resistance, lower limit of the maximum power required by the load (20.88 W) were predominant factors that panel does not operate with energy efficiency levels greater than 5 to 6%. The average converter efficiency designed in the field test reached 95%
Resumo:
In the oil industry the mixture oil/water occurs in the operations of production, transportation and refining, as well as during the use of its derivatives. The amount of water produced associated with the oil varies and can reach values of 90% in volume in the case of mature phase of the production fields. The present work deals with the development of new design of the Mixer Settler based on Phase Inversion (MDIF) in a laboratory scale. We envisage this application in industrial scale so the phases of project, construction and operation are considered. The modifications most significant, in comparison with the original prototype, include the materials of construction and the substitution of the equipment used in the mixing stage of the process. It was tested the viability of substitution of the original system of mechanical mixing by a static mixer. A statistical treatment by means of an experimental design of composed central type was used in order to evaluate the behavior of the main variables of the separation process as function of the efficiency of separation for the new device. This procedure is useful to delimit an optimal region of operation with the equipment. The variables of process considered on the experimental design were: oil concentration in the feeding water (mg/L); Total volumetric flow rate (L/h); Ratio organic/water on volumetric basis (O/A). The separation efficiency is calculated by comparison of the content of oil and greases in the inlet and outlet of the equipment. For determination of TOG (Total Oil and Grease), the method used was based in the absorption of radiation in the infra-red region. The equipment used for these determinations was InfraCal® TOG/TPH Model HATR-T2 of the Wilks Enterprise, Incorporation. It´s important to stand out that this method of measure has being used by PETROBRAS S.A. Results of global efficiency of separation oil/water varied from 75.3 to 97.7% for contaminated waters containing up to 1664,1 mg/L of oil. By means of tests carried out with a real sample of contaminated water supplied by PETROBRAS we have got an effluent specified in terms of the legal standards required for discharging. Thus, the new design of equipment constitutes a real alternative for the conventional systems of treatment of produced water in the oil industry
Resumo:
The increasing demand for energy and the environment consequences derived from the use of fossil energy, beyond the future scarcity of the oil that currently is the main power plant of the world, it stimulated the research around the production of biodiesel. In this work the synthesis of biodiesel of cotton in the methyl route was carried through, for had been in such a way used catalyst commercial homogeneous, Na-Methylat and the K-Methylat, aiming to the evaluation of the efficiency of them. An experimental planning 23 was elaborated aiming to evaluate the influence of the variable (molar reason oil/alcohol, % of catalyst and temperature) in the process as well as indicating the excellent point of operation in each case. The biodiesel was analyzed by gaseous chromatography, indicating a conversion of 96,79% when used Na-Methylat® as catalytic, and 95,65% when the K-Methylat® was used. Optimum result found with regard to the conversion was obtained at the following conditions: molar reason oil/alcohol (1:8), temperature of 40°C and 1% of catalyst Na-Methylat, reaching a 96,79% conversion, being, therefore, above of the established for the European norm (96.5%). The analysis of regression showed that the only significant effect for a confidence level of 95%, was of the changeable temperature. The variance analysis evidenced that the considered model is fitted quite to the experimental response, being statistically significant; however it does not serve inside for make forecasts of the intervals established for each variable. The best samples were analyzed by infra-red (IR) that identified the strong bands of axial deformation C=O of methylic ester, characterized through analyses physicochemical that had indicated conformity with the norms of the ANP, that with the thermal and rheological analyses had together evidenced that biodiesel can be used as combustible alternative in substitution to diesel
Resumo:
The rotary dryer is one of the most used equipments in processing industries. Its automatic control mode of operation is important specially to keep the moisture content of the final product in the desired value. The classical control strategies, like PID (proportional integral derivative) control, are largely used in the industrial sector because of its robustness and because they are easy to be implemented. In this work, a data acquisition system was implemented for monitoring the most relevant process variables, like: both inlet and outlet drying air temperature, dryer rotation, outlet air speed and humidity, and mass of the final product. Openloop tests were realized to identify a mathematical model able to represent the drying process for the rotary system. From this model, a PID controller was tuned using a direct synthesis method, assuming a first order trajectory. The PID controller was implemented in the system in order to control the inlet drying air temperature. By the end, closedloop tests (operating in automatic mode) were realized to observe the controller performance, and, after setting the best tune, experiments were realized using passion fruit seeds as raw material. The experiments realized in closedloop showed a satisfactory performance by the implemented control strategy for the drying air temperature of the rotary system