972 resultados para combustione biomasse materiale particolato (PM) idrocarburi policiclici aromatici (IPA) stufe a pellet


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The negative impacts of ambient aerosol particles, or particulate matter (PM), on human health and climate are well recognized. However, owing to the complexity of aerosol particle formation and chemical evolution, emissions control strategies remain difficult to develop in a cost effective manner. In this work, three studies are presented to address several key issues currently stymieing California's efforts to continue improving its air quality.

Gas-phase organic mass (GPOM) and CO emission factors are used in conjunction with measured enhancements in oxygenated organic aerosol (OOA) relative to CO to quantify the significant lack of closure between expected and observed organic aerosol concentrations attributable to fossil-fuel emissions. Two possible conclusions emerge from the analysis to yield consistency with the ambient organic data: (1) vehicular emissions are not a dominant source of anthropogenic fossil SOA in the Los Angeles Basin, or (2) the ambient SOA mass yields used to determine the SOA formation potential of vehicular emissions are substantially higher than those derived from laboratory chamber studies. Additional laboratory chamber studies confirm that, owing to vapor-phase wall loss, the SOA mass yields currently used in virtually all 3D chemical transport models are biased low by as much as a factor of 4. Furthermore, predictions from the Statistical Oxidation Model suggest that this bias could be as high as a factor of 8 if the influence of the chamber walls could be removed entirely.

Once vapor-phase wall loss has been accounted for in a new suite of laboratory chamber experiments, the SOA parameterizations within atmospheric chemical transport models should also be updated. To address the numerical challenges of implementing the next generation of SOA models in atmospheric chemical transport models, a novel mathematical framework, termed the Moment Method, is designed and presented. Assessment of the Moment Method strengths and weaknesses provide valuable insight that can guide future development of SOA modules for atmospheric CTMs.

Finally, regional inorganic aerosol formation and evolution is investigated via detailed comparison of predictions from the Community Multiscale Air Quality (CMAQ version 4.7.1) model against a suite of airborne and ground-based meteorological measurements, gas- and aerosol-phase inorganic measurements, and black carbon (BC) measurements over Southern California during the CalNex field campaign in May/June 2010. Results suggests that continuing to target sulfur emissions with the hopes of reducing ambient PM concentrations may not the most effective strategy for Southern California. Instead, targeting dairy emissions is likely to be an effective strategy for substantially reducing ammonium nitrate concentrations in the eastern part of the Los Angeles Basin.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Über die positive Entwicklung des Kabeljaubestandes unter Westgrönland, ab Mitte der 80iger Jahre wurde bereits im Vorjahr berichtet. Die mit FFS "Walther Herwig" im Herbst 1987 erzielten Surveyergebnisse dokumentieren einen steilen Anstieg der Bestandsgröße sowohl hinsichtlich der Individuenzahl (Abundanz) als auch des Bestandsgewichts (Biomasse) um das 4-fache auf 583 Millionen Fische bzw. um das 6-fache auf 464000 Tonnen. Diese Bestandszunahme war zahlenmäßig zu 88% und gewichtsmäßig zu 85% auf die Rekrutierung der 3 jährigen Kabeljau des starken Nachwuchsjahrganges 1984 zurückzuführen.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This report is a product of close industry-academia collaboration between British Aerospace and the Cambridge Engineering Design Centre (EDC). British Aerospace designs and integrates some of the most complex systems in the world, and its expertise in this field has enabled the company to become the United Kingdom's largest exporter. However, to stay at the forefront of the highly competitive aerospace industry it is necessary to seek new ways to work more effectively and more efficiently. The Cambridge EDC has played a part in supporting these needs by providing access to the methods and tools that it has developed for improving the process of designing mechanical systems. The EDC has gained an international reputation for the quality of its work in this subject. Thus, the collaboration is between two organisations each of whom are leaders in their respective fields. The central aim of the project has been to demonstrate how a systematic design process can be applied to a real design task identified by industry. The task selected was the design of a flight refuelling probe which would enable a combat aircraft to refuel from a "flying tanker". However, the systematic approach, methods and tools described in this report are applicable to most engineering design tasks. The findings presented in this report provide a sound basis for comparing the recommended systematic design process with industrial practice. The results of this comparison would enable the company to define ways in which its existing design process can be improved. This research project has a high degree of industrial relevance. The value of the work may be judged in terms of the opportunities it opens up for positive changes to the company's engineering operations. Several members of the EDC have contributed to the project. These include Dr Lucienne Blessing, Dr Stuart Burgess, Dr Amaresh Chakrabarti, Major Mark Nowack, Aylmer Johnson and Dr Paul Weaver. At British Aerospace special thanks must go to Alan Dean and David Halliday for their interest and the support they have given. The project has been managed by Dr Nigel Upton of British Aerospace during a 3 year secondment to the EDC.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

采用溶胶-凝胶法制作波导环形谐振腔, 讨论了环形谐振腔器件的传输特性。测量了在不同物质、不同体积分数的挥发性有机化合物(VOC)蒸气气氛下器件的传输光谱的敏感性。结果表明, 谐振波长随甲醇、乙醇、丙醇等醇类化合物, 以及丙酮、甲醛等蒸气体积分数的上升而向长波方向移动, 具有高的灵敏度, 且两者基本呈线性关系。其中, 对丙醇最敏感, 灵敏度达到1.403 pm/10-6。对甲烷和二甲苯也有微弱反应, 但是其灵敏度很低。也测量了水蒸气对传输谱特性的影响。观察到传输谱衬比度对不同挥发性有机化合物物质蒸气的不同敏

Relevância:

10.00% 10.00%

Publicador:

Resumo:

介绍了一种基于3×3和2×2光纤耦合器构成的非平衡马赫-曾德尔干涉仪的波长解调方案。理论分析和数据对比表明,相对于由两个2×2光纤耦合器构成的马赫-曾德尔干涉仪,本干涉仪具有宽谱的灵敏度、能跟踪波长的变化方向和相位展开的优点,实验方案用于测量固定在悬臂梁上的传感光纤布拉格光栅(FBG)的峰值波长变化,获得了±1pm的静态波长解调精度,在10Hz处的动态分辨率为27nε/√Hz。相位展开算法使得应变测量范围达到了2014με,对应的相位变化为3.22π。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We introduce an in vitro diagnostic magnetic biosensing platform for immunoassay and nucleic acid detection. The platform has key characteristics for a point-of-use (POU) diagnostic: portability, low-power consumption, low cost, and multiplexing capability. As a demonstration of capabilities, we use this platform for the room temperature, amplification-free detection of a 31 bp DNA oligomer and interferon-gamma (a protein relevant for tuberculosis diagnosis). Reliable assay measurements down to 100 pM for the DNA and 1 pM for the protein are demonstrated. We introduce a novel "magnetic freezing" technique for baseline measurement elimination and to enable spatial multiplexing. We have created a general protocol for adapting integrated circuit (IC) sensors to any of hundreds of commercially available immunoassay kits and custom designed DNA sequences.

We also introduce a method for immunotherapy treatment of malignant gliomas. We utilize leukocytes internalized with immunostimulatory nanoparticle-oligonucleotide conjugates to localize and retain immune cells near the tumor site. As a proof-of-principle, we develop a novel cell imaging and incubation chamber for in vitro magnetic motility experiments. We use the apparatus to demonstrate the controlled movement of magnetically loaded THP-1 leukocytes.

Finally, we introduce an IC transmitter and power ampli er (PA) that utilizes electronic digital infrastructure, sensors, and actuators to self-heal and adapt to process, dynamic, and environmental variation. Traditional IC design has achieved incredible degrees of reliability by ensuring that billions of transistors on a single IC die are all simultaneously functional. Reliability becomes increasingly difficult as the size of a transistor shrinks. Self-healing can mitigate these variations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O objetivo deste estudo foi comparar in vitro o desgaste dental de pré-molares (PM) e molares (M) e sua relação com o valor de dureza Vickers dos materiais utilizados como antagonistas em uma máquina de abrasão simulada para provocar o desgaste nos dentes testados. Os materiais antagonistas utilizados foram VeraBond II (liga de Ni-Cr), Solidex (resina composta) e IPS Empress 2 (cerâmica). Para cada ensaio de dureza, foram preparados seis corpos-de-prova de cada material, os quais foram polidos sob refrigeração, com ciclo de 20 min para cada granulação. Num microdurômetro (HMV-2), foram realizadas três mossas por quadrante, cada uma sob carga de 19,614 N por 30 s, totalizando 12 mossas de base quadrada com ângulo de 136 entre os planos. O teste de abrasão foi realizado numa máquina simuladora de abrasão, freqüência de 265 ciclos/min e 4,4 Hz, com um percurso do antagonista de 10 mm à velocidade de 88 mm/s. Cada dente foi testado em oposição a um antagonista (foram 6 pares dente/material para cada grupo), em água deionizada, sob carga de 5 N, por 150 min, num total de 39.750 ciclos. Foram utilizados dezenove dentes 1 pré-molares, dezenove 3 molares e confeccionados doze antagonistas em cada material em forma de pastilha. Cada grupo de seis dentes foi testado em oposição a seis antagonistas do mesmo material. Ademais, um dente 1 pré-molar (PM) e um dente 3 molar (M) foram testados em oposição ao Plexiglass. Com relação ao desgaste do esmalte dentário (PM+M) segundo o material antagonista, o teste de Kruskal-Wallis evidenciou diferença significativa com p-valor < 0,001 e o teste de Mann-Whitney evidenciou diferença significativa nas comparações PM+M/resina X PM+M/metal (p-valor < 0,001), PM+M/resina X PM+M/cerâmica (p-valor < 0,001) e PM+M/metal X PM+M/cerâmica (p-valor = 0,002). A análise isolada, considerando pré-molares e molares separadamente, encontrou diferença significativa em relação ao desgaste do esmalte dentário no teste de Kruskall-Wallis, porém não detectou diferença significativa no teste de comparação múltipla Mann-Whitney quando comparou o desgaste sofrido pelo PM/metal em relação ao PM/cerâmica. Em relação à dureza Vickers detectou-se diferença significativa da dureza dos materiais no teste de Kruskall-Wallis (p-valor < 0,001) e também no teste de Mann-Whitney nas comparações múltiplas com p-valor = 0,002. Comparando-se a dureza com a perfilometria, observou-se uma correlação estatisticamente significativa (p ≤ 0,05) na correlação negativa (ρ= -0,829) entre a dureza do metal como material antagonista e o desgaste do esmalte dentário do dente molar. Os resultados sugeriram que todo material restaurador indireto estudado causou desgaste ao esmalte dentário quando submetido a forças de simulação de abrasão com carga. Embora tenha sido observada correlação entre dureza e resistência à abrasão, essa correlação foi pouco significativa.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

单长周期光栅迈克耳孙(Michelson)干涉仪是由尾纤端面蒸镀高反膜的单根长周期光纤光栅构成。入射光经长周期光栅后,部分被耦合到包层中传输。经过包层和纤芯传输的光信号经尾纤端面反射后,重新耦合回到长周期光栅中,在光栅区域形成干涉。通过理论计算分析了各种因素对其光谱响应的影响。从实验上得到了干涉光谱的谐振峰波长位移与光纤段温度变化成良好的线性关系,测得其温度系数为31.3pm/℃。表明这种结构可用于高温传感或作为波分复用滤波器。