994 resultados para calibration method


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Liquid scintillation counting (LSC) is one of the most widely used methods for determining the activity of 241Pu. One of the main challenges of this counting method is the efficiency calibration of the system for the low beta energies of 241Pu (Emax = 20.8 keV). In this paper we compare the two most frequently used methods, the CIEMAT/NIST efficiency tracing (CNET) method and the experimental quench correction curve method. Both methods proved to be reliable, and agree within their uncertainties, for the expected quenching conditions of the sources.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aortic stiffness is an independent predictor factor for cardiovascular risk. Different methods for determining pulse wave velocity (PWV) are used, among which the most common are mechanical methods such as SphygmoCor or Complior, which require specific devices and are limited by technical difficulty in obtaining measurements. Doppler guided by 2D ultrasound is a good alternative to these methods. We studied 40 patients (29 male, aged 21 to 82 years) comparing the Complior method with Doppler. Agreement of both devices was high (R = 0.91, 0.84-0.95, 95% CI). The reproducibility analysis revealed no intra-nor interobserver differences. Based on these results, we conclude that Doppler ultrasound is a reliable and reproducible alternative to other established methods for themeasurement of aortic PWV

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We performed a comprehensive study to assess the fit for purpose of four chromatographic conditions for the determination of six groups of marine lipophilic toxins (okadaic acid and dinophysistoxins, pectenotoxins, azaspiracids, yessotoxins, gymnodimine and spirolides) by LC-MS/MS to select the most suitable conditions as stated by the European Union Reference Laboratory for Marine Biotoxins (EURLMB). For every case, the elution gradient has been optimized to achieve a total run-time cycle of 12 min. We performed a single-laboratory validation for the analysis of three relevant matrices for the seafood aquaculture industry (mussels, pacific oysters and clams), and for sea urchins for which no data about lipophilic toxins have been reported before. Moreover, we have compared the method performance under alkaline conditions using two quantification strategies: the external standard calibration (EXS) and the matrix-matched standard calibration (MMS). Alkaline conditions were the only scenario that allowed detection windows with polarity switching in a 3200 QTrap mass spectrometer, thus the analysis of all toxins can be accomplished in a single run, increasing sample throughput. The limits of quantification under alkaline conditions met the validation requirements established by the EURLMB for all toxins and matrices, while the remaining conditions failed in some cases. The accuracy of the method and the matrix effects where generally dependent on the mobile phases and the seafood species. The MMS had a moderate positive impact on method accuracy for crude extracts, but it showed poor trueness for seafood species other than mussels when analyzing hydrolyzed extracts. Alkaline conditions with EXS and recovery correction for OA were selected as the most proper conditions in the context of our laboratory. This comparative study can help other laboratories to choose the best conditions for the implementation of LC-MS/MS according to their own necessities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

New zircon U-Pb ages are proposed for late Early and Middle Triassic volcanic ash layers from the Luolou and Baifeng formations (northwestern Guangxi, South China). These ages are based on analyses of single, thermally annealed and chemically abraded zircons. Calibration with ammonoid ages indicate a 250.6 +/- 0.5 Ma age for the early Spathian Tirolites/Columbites beds, a 248.1 +/- 0.4 Ma age for the late Spathian Neopopanoceras haugi Zone, a 246.9 +/- 0.4 Ma age for the early middle Anisian Acrochordiceras hyatti Zone, and a 244.6 +/- 0.5 Ma age for the late middle Anisian Balatonites shoshonensis Zone. The new dates and previously published U-Pb ages indicate a duration of ca. 3 my for the Spathian, and minimal durations of 4.5 +/- 0.6 my for the Early Triassic and of 6.6+0.7/-0.9 my for the Anisian. The new Spathian dates are in a better agreement with a 252.6 +/- 0.2 Ma age than with a 251.4 +/- 0.3 Ma age for the Permian-Triassic boundary. These dates also highlight the extremely uneven duration of the four Early Triassic substages (Griesbachian, Dienerian, Smithian, and Spathian), of which the Spathian exceeds half of the duration of the entire Early Triassic. The simplistic assumption of equal duration of the four Early Triassic subdivisions is no longer tenable for the reconstruction of recovery patterns following the end Permian mass extinction. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chromatin immunoprecipitation followed by deep sequencing (ChIP-seq) experiments are widely used to determine, within entire genomes, the occupancy sites of any protein of interest, including, for example, transcription factors, RNA polymerases, or histones with or without various modifications. In addition to allowing the determination of occupancy sites within one cell type and under one condition, this method allows, in principle, the establishment and comparison of occupancy maps in various cell types, tissues, and conditions. Such comparisons require, however, that samples be normalized. Widely used normalization methods that include a quantile normalization step perform well when factor occupancy varies at a subset of sites, but may miss uniform genome-wide increases or decreases in site occupancy. We describe a spike adjustment procedure (SAP) that, unlike commonly used normalization methods intervening at the analysis stage, entails an experimental step prior to immunoprecipitation. A constant, low amount from a single batch of chromatin of a foreign genome is added to the experimental chromatin. This "spike" chromatin then serves as an internal control to which the experimental signals can be adjusted. We show that the method improves similarity between replicates and reveals biological differences including global and largely uniform changes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Realistic rendering animation is known to be an expensive processing task when physically-based global illumination methods are used in order to improve illumination details. This paper presents an acceleration technique to compute animations in radiosity environments. The technique is based on an interpolated approach that exploits temporal coherence in radiosity. A fast global Monte Carlo pre-processing step is introduced to the whole computation of the animated sequence to select important frames. These are fully computed and used as a base for the interpolation of all the sequence. The approach is completely view-independent. Once the illumination is computed, it can be visualized by any animated camera. Results present significant high speed-ups showing that the technique could be an interesting alternative to deterministic methods for computing non-interactive radiosity animations for moderately complex scenarios

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diagnosis of several neurological disorders is based on the detection of typical pathological patterns in the electroencephalogram (EEG). This is a time-consuming task requiring significant training and experience. Automatic detection of these EEG patterns would greatly assist in quantitative analysis and interpretation. We present a method, which allows automatic detection of epileptiform events and discrimination of them from eye blinks, and is based on features derived using a novel application of independent component analysis. The algorithm was trained and cross validated using seven EEGs with epileptiform activity. For epileptiform events with compensation for eyeblinks, the sensitivity was 65 +/- 22% at a specificity of 86 +/- 7% (mean +/- SD). With feature extraction by PCA or classification of raw data, specificity reduced to 76 and 74%, respectively, for the same sensitivity. On exactly the same data, the commercially available software Reveal had a maximum sensitivity of 30% and concurrent specificity of 77%. Our algorithm performed well at detecting epileptiform events in this preliminary test and offers a flexible tool that is intended to be generalized to the simultaneous classification of many waveforms in the EEG.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Platelet-rich plasma (PRP) is a volume of plasma fraction of autologous blood having platelet concentrations above baseline whole-blood values due to processing and concentration. PRP is used in various surgical fields to enhance soft-tissue and bone healing by delivering supra-physiological concentrations of autologous platelets at the site of tissue damage. These preparations may provide a good cellular source of various growth factors and cytokines, and modulate tissue response to injury. Common clinically available materials for blood preparations combined with a two-step centrifugation protocol at 280g each, to ensure cellular component integrity, provided platelet preparations which were concentrated 2-3 fold over total blood values. Costs were shown to be lower than those of other methods which require specific equipment and high-cost disposables, while safety and traceability can be increased. PRP can be used for the treatment of wounds of all types including burns and also of split-thickness skin graft donor sites, which are frequently used in burn management. The procedure can be standardized and is easy to adapt in clinical settings with minimal infrastructure, thus enabling large numbers of patients to benefit from a form of cellular therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Laparoscopic techniques have been proposed as an alternative to open surgery for therapy of peptic ulcer perforation. They provide better postoperative comfort and absence of parietal complications, but leakage occurs in 5% of cases. We describe a new method combining laparoscopy and endoluminal endoscopy, designed to ensure complete closure of the perforation. METHODS: Six patients with anterior ulcer perforations (4 duodenal, 2 gastric) underwent a concomitant laparoscopy and endoluminal endoscopy with closure of the orifice by an omental plug attracted into the digestive tract. RESULTS: All perforations were sealed. The mean operating time was 72 minutes. The mean hospital stay was 5.5 days. There was no morbidity and no mortality. At the 30-day evaluation all ulcers but one (due to Helicobacter pylori persistence) were healed. CONCLUSIONS: This method is safe and effective. Its advantages compared with open surgery or laparoscopic patching as well as its cost-effectiveness should be studied in prospective randomized trials.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Saffaj et al. recently criticized our method of monitoring carbon dioxide in human postmortem cardiac gas samples using Headspace-Gas Chromatography-Mass Spectrometry. According to the authors, their demonstration, based on the latest SFSTP guidelines (established after 2007 [1,2]) fitted for the validation of drug monitoring bioanalytical methods, has put in evidence potential errors. However, our validation approach was built using SFSTP guidelines established before 2007 [3-6]. We justify the use of these guidelines because of the post-mortem context of the study (and not clinical) and the gaseous state of the sample (and not solid or liquid). Using these guidelines, our validation remains correct.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An analytic method to evaluate nuclear contributions to electrical properties of polyatomic molecules is presented. Such contributions control changes induced by an electric field on equilibrium geometry (nuclear relaxation contribution) and vibrational motion (vibrational contribution) of a molecular system. Expressions to compute the nuclear contributions have been derived from a power series expansion of the potential energy. These contributions to the electrical properties are given in terms of energy derivatives with respect to normal coordinates, electric field intensity or both. Only one calculation of such derivatives at the field-free equilibrium geometry is required. To show the useful efficiency of the analytical evaluation of electrical properties (the so-called AEEP method), results for calculations on water and pyridine at the SCF/TZ2P and the MP2/TZ2P levels of theory are reported. The results obtained are compared with previous theoretical calculations and with experimental values

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O Lunney Scoring Method for Rating Accuracy of Nursing Diagnoses (LSM) é uma escala de diferencial semântico que foi desenvolvida por Lunney para estimar a acurácia dos diagnósticos de enfermagem. O objetivo deste estudo foi adaptar o LSM para a língua portuguesa e avaliar as sua propriedades psicométricas. A escala original foi traduzida para o português, revertida para o inglês e as duas versões em inglês foram comparadas para ajustar a versão em português que passou a ser denominada Escala de Acurácia de Diagnóstico de Enfermagem de Lunney - EADE. Quatro enfermeiras foram orientadas sobre a EADE e a aplicaram em 159 diagnósticos formulados para 26 pacientes de três estudos primários com base nos registros de entrevista e exame físico de cada paciente. Os índices Kappa de Cohen mostraram ausência de concordância entre as avaliadoras, o que indica que o instrumento adaptado não tem confiabilidade satisfatória. Em virtude desse resultado, não foi realizada estimativa de validade.