989 resultados para blood examination


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multilayer samples of white architectural paint potentially have very high evidential value in forensic casework, because the probability that two unrelated samples will have the same sequence of layers is extremely low. However, discrimination between the different layers using optical microscopy is often difficult or impossible. Here, lateral scanning Raman spectroscopy has been used to chemically map the cross-sections of multilayer white paint chips. It was found that the spectra did allow the different layers to be delineated on the basis of their spectral features. The boundaries between different layers were not as sharp as expected, with transitions occurring over length scales of > 20 µm, even with laser spot diameters <4 µm. However, the blurring of the boundaries was not so large as to prevent recording and identification of spectra from each of the layers in the samples. This method clearly provides excellent discrimination between different multilayer white paint samples and can readily be incorporated into existing procedures for examination of paint transfer evidence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study examined the effects of polymeric components on the physical state of chlorhexidine within bioadhesive, semisolid formulations using Raman spectroscopy. Semisolid formulations were prepared in which chlorhexidine base (CHX, 5%w/w, particle size

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel approach has been developed to determine ranitidine in paediatric samples using dried blood spots (DBS) on Guthrie cards (Whatman 903). A selective and sensitive HPLC-MS/MS assay has been developed and validated using small volumes of blood (30µl). A 6mm disc was punched from each DBS and extracted with methanolic solution of the internal standard (IS) nizatidine. This was further subjected to solid phase extraction (SPE), followed by reversed phase HPLC separation, using a XBridge™ C18 column and mobile phase 10mM ammonium acetate/methanol (98:2 v/v) with a flow rate of 0.3mL/min. This was combined with multiple reaction monitoring (MRM) mass detection using electrospray ionisation (ESI). The calibration curve for ranitidine was found linear over the range 10-500ng/mL (r=0.996). The limit of quantification (LOQ) of the method was validated at 10ng/mL. Accuracy and precision values for within and between days were

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hypertension, a key risk factor for stroke, cardiovascular disease and dementia, is associated with chronic vascular inflammation, and although poorly understood, putative mechanisms include proinflammatory responses induced by mechanical stretching, with cytokine release and associated upregulated expression of adhesion molecules. Because blood pressure increases with age, we measured baseline and tumour necrosis alpha (TNF-a)-stimulated CD11b/CD18 adhesion molecule expression on leucocytes to assess any association between the two. In 38 subjects (mean age 85 years), consecutively enrolled from Belfast Elderly Longitudinal Free-Living Aging Study (BELFAST), baseline and TNF-a-stimulated CD11b/CD18 expression on separated monocytes and neutrophils increased with systolic blood pressure >120 mmHg (p=0.05) and for lymphocytes, with diastolic blood pressure >80 mmHg (p<0.05).These findings show increased potential stickiness of intravascular cells with increasing blood pressure which is accentuated by TNF-a, and suggest mechanistic reasons why better hypertension control is important. 

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Automated examination timetabling has been addressed by a wide variety of methodologies and techniques over the last ten years or so. Many of the methods in this broad range of approaches have been evaluated on a collection of benchmark instances provided at the University of Toronto in 1996. Whilst the existence of these datasets has provided an invaluable resource for research into examination timetabling, the instances have significant limitations in terms of their relevance to real-world examination timetabling in modern universities. This paper presents a detailed model which draws upon experiences of implementing examination timetabling systems in universities in Europe, Australasia and America. This model represents the problem that was presented in the 2nd International Timetabling Competition (ITC2007). In presenting this detailed new model, this paper describes the examination timetabling track introduced as part of the competition. In addition to the model, the datasets used in the competition are also based on current real-world instances introduced by EventMAP Limited. It is hoped that the interest generated as part of the competition will lead to the development, investigation and application of a host of novel and exciting techniques to address this important real-world search domain. Moreover, the motivating goal of this paper is to close the currently existing gap between theory and practice in examination timetabling by presenting the research community with a rigorous model which represents the complexity of the real-world situation. In this paper we describe the model and its motivations, followed by a full formal definition.