965 resultados para artificial linear structures


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study presents an experimental program to assess the tensile strain distribution along prestressed carbon fiber reinforced polymer (CFRP) reinforcement flexurally applied on the tensile surface of RC beams according to near surface mounted (NSM) technique. Moreover, the current study aims to propose an analytical formulation, with a design framework, for the prediction of distribution of CFRP tensile strain and bond shear stress and, additionally, the prestress transfer length. After demonstration the good predictive performance of the proposed analytical approach, parametric studies were carried out to analytically evaluate the influence of the main material properties, and CFRP and groove cross section on the distribution of the CFRP tensile strain and bond shear stress, and on the prestress transfer length. The proposed analytical approach can also predict the evolution of the prestress transfer length during the curing time of the adhesive by considering the variation of its elasticity modulus during this period.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work proposes a constitutive model to simulate nonlinear behaviour of cement based materials subjected to different loading paths. The model incorporates a multidirectional fixed smeared crack approach to simulate crack initiation and propagation, whereas the inelastic behaviour of material between cracks is treated by a numerical strategy that combines plasticity and damage theories. For capturing more realistically the shear stress transfer between the crack surfaces, a softening diagram is assumed for modelling the crack shear stress versus crack shear strain. The plastic damage model is based on the yield function, flow rule and evolution law for hardening variable, and includes an explicit isotropic damage law to simulate the stiffness degradation and the softening behaviour of cement based materials in compression. This model was implemented into the FEMIX computer program, and experimental tests at material scale were simulated to appraise the predictive performance of this constitutive model. The applicability of the model for simulating the behaviour of reinforced concrete shear wall panels submitted to biaxial loading conditions, and RC beams failing in shear is investigated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Timber connections represent the crucial part of a timber structure and a great variability exists in terms of types of connections and mechanisms. Taking as case study the widespread traditional timber frame structures, in particular the Portuguese Pombalino buildings, one of the most common timber connection is the half-lap joint. Connections play a major role in the overall behaviour of a structure, particularly when assessing their seismic response, since damage is concentrated at the connections. For this reason, an experimental campaign was designed and distinct types of tests were carried out on traditional half-lap joints to assess their in-plane response. In particular, pull-out and in-plane cyclic tests were carried out on real scale unreinforced connections. Subsequently, the connections were retrofitted, using strengthening techniques such as self-tapping screws, steel plates and GFRP sheets. The tests chosen were meant to capture the hysteretic behaviour and dissipative capacity of the connections and characterise their response and, therefore, their influence on the seismic response of timber frame walls, particularly concerning their uplifting and rotation capacity, that could lead to rocking in the walls. In this paper, the results of the experimental campaign are presented in terms of hysteretic curves, dissipated energy and equivalent viscous damping ratio. Moreover, recommendations are provided on the most appropriate retrofitting solutions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Existing masonry structures are usually associated to a high seismic vulnerability, mainly due to the properties of the materials, weak connections between floors and load-bearing walls, high mass of the masonry walls and flexibility of the floors. For these reasons, the seismic performance of existing masonry structures has received much attention in the last decades. This study presents the parametric analysis taking into account the deviations on features of the gaioleiro buildings - Portuguese building typology. The main objective of the parametric analysis is to compare the seismic performance of the structure as a function of the variations of its properties with respect to the response of a reference model. The parametric analysis was carried out for two types of structural analysis, namely for the non-linear dynamic analysis with time integration and for the pushover analysis with distribution of forces proportional to the inertial forces of the structure. The Young's modulus of the masonry walls, Young's modulus of the timber floors, the compressive and tensile non-linear properties (strength and fracture energy) were the properties considered in both type of analysis. Additionally, in the dynamic analysis, the influences of the vis-cous damping and of the vertical component of the earthquake were evaluated. A pushover analysis proportional to the modal displacement of the first mode in each direction was also carried out. The results shows that the Young's modulus of the masonry walls, the Young's modulus of the timber floors and the compressive non-linear properties are the pa-rameters that most influence the seismic performance of this type of tall and weak existing masonry structures. Furthermore, it is concluded that that the stiffness of the floors influences significantly the strength capacity and the collapse mecha-nism of the numerical model. Thus, a study on the strengthening of the floors was also carried out. The increase of the thickness of the timber floors was the strengthening technique that presented the best seismic performance, in which the reduction of the out-of-plane displacements of the masonry walls is highlighted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The structural analysis involves the definition of the model and selection of the analysis type. The model should represent the stiffness, the mass and the loads of the structure. The structures can be represented using simplified models, such as the lumped mass models, and advanced models resorting the Finite Element Method (FEM) and Discrete Element Method (DEM). Depending on the characteristics of the structure, different types of analysis can be used such as limit analysis, linear and non-linear static analysis and linear and non-linear dynamic analysis. Unreinforced masonry structures present low tensile strength and the linear analyses seem to not be adequate for assessing their structural behaviour. On the other hand, the static and dynamic non-linear analyses are complex, since they involve large time computational requirements and advanced knowledge of the practitioner. The non-linear analysis requires advanced knowledge on the material properties, analysis tools and interpretation of results. The limit analysis with macro-blocks can be assumed as a more practical method in the estimation of maximum load capacity of structure. Furthermore, the limit analysis require a reduced number of parameters, which is an advantage for the assessment of ancient and historical masonry structures, due to the difficult in obtaining reliable data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Earthworks involve the levelling or shaping of a target area through the moving or processing of the ground surface. Most construction projects require earthworks, which are heavily dependent on mechanical equipment (e.g., excavators, trucks and compactors). Often, earthworks are the most costly and time-consuming component of infrastructure constructions (e.g., road, railway and airports) and current pressure for higher productivity and safety highlights the need to optimize earthworks, which is a nontrivial task. Most previous attempts at tackling this problem focus on single-objective optimization of partial processes or aspects of earthworks, overlooking the advantages of a multi-objective and global optimization. This work describes a novel optimization system based on an evolutionary multi-objective approach, capable of globally optimizing several objectives simultaneously and dynamically. The proposed system views an earthwork construction as a production line, where the goal is to optimize resources under two crucial criteria (costs and duration) and focus the evolutionary search (non-dominated sorting genetic algorithm-II) on compaction allocation, using linear programming to distribute the remaining equipment (e.g., excavators). Several experiments were held using real-world data from a Portuguese construction site, showing that the proposed system is quite competitive when compared with current manual earthwork equipment allocation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Given the fact that using timber frame structures has proven to improve the seismic behavior of vernacular architecture, as has been reported in past earthquakes in many countries, its preservation as a traditional earthquake resistant practice is important. This paper firstly intends to evaluate whether the use of timber frames as a traditional seismic resistant technique for vernacular architecture in the South of Portugal, traditionally a seismic region, is still active. Secondly, the city of Vila Real de Santo António was selected as a case study because it also followed a Pombaline development contemporary to the reconstruction of Lisbon. The plan included the provision of timber frame partition walls for some of the buildings and, thus, an overview of the type of constructions originally conceived is provided. Finally, the alterations done in the original constructions and the current state of the city center are described and the effect of these changes on the seismic vulnerability of the city is discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Archeology and related areas have a special interest on cultural heritage sites since they provide valuable information about past civilizations. However, the ancient buildings present in these sites are commonly found in an advanced state of degradation which difficult the professional/expert analysis. Virtual reconstructions of such buildings aim to provide a digital insight of how these historical places could have been in ancient times. Moreover, the visualization of such models has been explored by some Augmented Reality (AR) systems capable of providing support to experts. Their compelling and appealing environments have also been applied to promote the social and cultural participation of general public. The existing AR solutions regarding this thematic rarely explore the potential of realism, due to the following lacks: the exploration of mixed environments is usually only supported for indoors or outdoors, not both in the same system; the adaptation of the illumination conditions to the reconstructed structures is rarely addressed causing a decrease of credibility. MixAR [1] is a system concerned with those challenges, aiming to provide the visualization of virtual buildings augmented upon real ruins, allowing soft transitions among its interiors and exteriors and using relighting techniques for a faithful interior illumination, while the user freely moves in a given cultural heritage site, carrying a mobile unit. Regarding the focus of this paper, we intend to report the current state of MixAR mobile unit prototype, which allows visualizing virtual buildings – properly aligned with real-world structures – based on user's location, during outdoor navigation. In order to evaluate the prototype performance, a set of tests were made using virtual models with different complexities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An organization manages to regulate, standardize and optimize its operations in a way that places health and safety first by considering Health, Safety, Environment and Ergonomics (HSEE). In order to provide a theoretical foundation for Companies’ Occupational Health and Safety Internal Structures (COHSIS) allowing the focus on safety, COHSIS and its fundamentals were reviewed and described based on a brief literature review, which have included both papers published in journals, as well as works made available by selected organizations with mature safety culture. Three COHSIS were defined for description of its fundamentals, enabling improve the usability of its terminologies and provide the mentioned theoretical foundation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Técnicas de sensoriamento remoto são fundamentais para o monitoramento das mudanças de uso da terra, principalmente em áreas extensas como a Amazônia. O mapeamento de uso da terra, geralmente é realizado por métodos de classificação manual ou digital pixel a pixel, os quais consomem muito tempo. Este estudo aborda a aplicação do modelo linear de mistura em uma imagem Landsat-TM segmentada para o mapeamento das classes de uso da terra na região do reservatório de Tucuruí-PA para os anos de 1996 e 2001.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Existem muitas preocupações ecológicas do impacto que a construção de grandes lagos na Amazônia podem provocar, principalmente relacionadas ao microclima. Este estudo visa aumentar o conhecimento científico sobre a distribuição de chuvas antes e depois da formação do lago artificial da UHE Tucuruí-PA. Foram utilizados dados diários de precipitação dos períodos de 1972 a 1983 (pré-enchimento) e de 1984 a 1996 (pós-enchimento) para as cidades de Tucuruí e Marabá-PA. Comparando-se os totais mensais (pré e pós-enchimento), não se observam diferenças estatisticamente significantes (foram aplicados os testes de Fisher e Man-Whitney). Analisando-se a ocorrência de dias com precipitação superior a 5 e 25 mm.dia-1, também não se observam diferenças estatisticamente significativas. Há um leve aumento do número de dias com chuvas leves no final período sêco após a formação do lago, talvez devido a alta evaporação do lago artificial. Também não se observou modificações do início ou final da estação chuvosa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tese de Doutoramento - Civil Engineering

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo desta pesquisa foi avaliar os dados do sensor MODIS para detectar e monitorar cicatrizes de áreas recém queimadas. Utilizamos imagens da reflectância de superfície do sensor MODIS: produto MOD09 (dia 5 de outubro) e produto MOD13A1 (meses de outubro e novembro). Foi avaliada também uma série temporal de um ano dos índices de vegetação (IV) EVI e NDVI (produto MOD13A1). Uma imagem do sensor ETM+ (dia 5 de outubro) foi utilizada como base para a delimitação dos polígonos amostrais e avaliação dos dados MODIS devido a sua melhor resolução espacial. A metodologia focou na aplicação do modelo linear de mistura espectral nas imagens reflectância para a geração das imagens fração sombra. Análises de regressão foram efetuadas para comparação entre o percentual de sombra derivado da imagem ETM+ e das imagens MODIS. As alterações multitemporais nas imagens IV foram avaliadas com base no teste de Tukey. Os resultados mostraram que a imagem fração sombra gerada a partir do produto MOD09 apresentou um R² = 0,66 (p < 0,01) em relação aos dados ETM+. Para as imagens do produto MOD13A1 não foram identificadas relações significativas. Os IV dentro dos mesmos polígonos apresentaram uma variação sazonal durante o ano. No entanto, não houve uma diminuição significativa dos valores destes índices nos meses onde foram observadas as cicatrizes de áreas recém queimadas. Portanto, o produto MOD09 mostrou-se mais eficiente que o produto MOD13A1 para a detecção de cicatrizes de áreas recém queimadas. A análise multitemporal dos IV sugeriu que não foi possível detectar este mesmo padrão na área de estudo.