993 resultados para aneurisma de aorta torácica


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Traditionally, the transcatheter aortic valve replacement is performed through a transapical, a transfemoral or a trans-subclavian approach. Recently, the transaortic approach for transcatheter aortic valve replacement through the distal part of the ascending aorta was successfully implemented in order to avoid peripheral vascular access-related complications and apical life-threatening haemorrhage. The Sapien? stent valve has great transaortic potential because it can be loaded 'upside down' in different generations of delivery systems. However, because of their health regulatory systems and despite the launch, in 2012, of the latest generation of the Ascendra? delivery system, the Ascendra+?, specifically designed for transapical and transaortic valve placements, several countries are still using the first generations of Ascendra? (Ascendra? 1 and 2). This device was specifically designed for transapical procedures, and retrograde stent-valve positioning through the stenotic aortic valve may be very challenging and risk the integrity of the aorta. We describe the manoeuvre required in order to pass the stenotic aortic valve safely in a retrograde direction using the Sapien? stent valve and the first generations of Ascendra?.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to evaluate a free-breathing three-dimensional (3D) dual inversion-recovery (DIR) segmented k-space gradient-echo (turbo field echo [TFE]) imaging sequence at 3T for the quantification of aortic vessel wall dimensions. The effect of respiratory motion suppression on image quality was tested. Furthermore, the reproducibility of the aortic vessel wall measurements was investigated. Seven healthy subjects underwent 3D DIR TFE imaging of the aortic vessel wall with and without respiratory navigator. Subsequently, this sequence with respiratory navigator was performed twice in 10 healthy subjects to test its reproducibility. The signal-to-noise (SNR), contrast-to-noise ratio (CNR), vessel wall sharpness, and vessel wall volume (VWV) were assessed. Data were compared using the paired t-test, and the reproducibility of VWV measurements was evaluated using intraclass correlation coefficients (ICCs). SNR, CNR, and vessel wall sharpness were superior in scans performed with respiratory navigator compared to scans performed without. The ICCs concerning intraobserver, interobserver, and interscan reproducibility were excellent (0.99, 0.94, and 0.95, respectively). In conclusion, respiratory motion suppression substantially improves image quality of 3D DIR TFE imaging of the aortic vessel wall at 3T. Furthermore, this optimized technique with respiratory motion suppression enables assessment of aortic vessel wall dimensions with high reproducibility.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Summary Cells in tissues and organs coordinate their activities by communicating with each other through intercellular channels named gap junctions. These channels are conduits between the cytoplasmic compartments of adjacent cells, allowing the exchange of small molecules which may be crucial for hormone secretion. Renin is normally secreted in a regulated manner by specific cells of the juxtaglomerular apparatus located within the renal cortex. Gap junctional communication may be requisite to maintain an accurate functioning in coordination of renin-producing cells, more especially as renin is of paramount importance for the control of blood pressure. Connexin43 (Cx43) and Cx40 form gap junctions that link in vivo the cells of the juxtaglomerular apparatus. Cx43 links the endothelial cells, whereas gap junctions made of Cx40 connect the endothelial cells, the renin secreting cells, as well as the endothelial cells of to the renin-secreting cells of the afferent arteriole. The observation that loss of Cx40 results in chronic hypertension associated with altered vasomotion and signal conduction along arterioles, has lead us to suggest that connexins may contribute to control blood pressure by participating to the integration of various mechanical, osmotic and electrochemical stimuli involved in the control of renin secretion and by mediating the adaptive changes of the vascular wall induced by elevated blood pressure and mechanical stress. We therefore postulated that the absence of Cx40 could have deleterious effects on the coordinated functioning of the renin-containing cells, hence accounting for hypertension. In the first part of my thesis, we reported that Cx40-deficient mice (Cx40) are hypertensive due to increased plasma renin levels and numbers of renin-producing cells. Besides, we demonstrated that prostaglandins and nitric oxide, which are possible mediators in the regulation of renin secretion by the macula densa, exert a critical role in the mechanisms controlling blood pressure ín Cx40 knockout hypertensive mice. In view of previous studies that stated avessel-specifc increase in the expression of Cx43 during renin-dependent hypertension, we hypothesized that Cx43 channels are particularly well-matched to integrate the response of cells constituting the vascular wall to hypertensive conditions. Using transgenic mice in which Cx43 was replaced by Cx32, we revealed that the replacement of Cx43 by Cx32 is associated with decreased expression and secretion of renin and prevent the renin-dependent hypertension which is normally induced in the 2K1C model. To gain insights into the regulation of connexins in two separate tissues exposed to the same fluid pressure, the second part of my thesis work was dedicated to the study of the impact of chronic hypertension and related hypertrophy on the expression of the cardiovascular connexins (Cx40, Cx37, Cx43 and Cx45) in mouse aorta and heart. Our results documented that the expression of connexins is differentially regulated in mouse aorta. according to the models of hypertension. Thus, blood pressure induces mechanical forces that differentially alter the expression of vascular connexins in order to respond to an adaptation of the aortic wall observed under pathological conditions. Altogether these data provide the first evidences that intercellular communication mediated by gap junctions is required for a proper renin secretion from the juxtaglomerular apparatus in order to control blood pressure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: The alpha1-adrenergic receptors (alpha1-ARs) play a key role in cardiovascular homeostasis. However, the functional role of alpha1-AR subtypes in vivo is still unclear. The aim of this study was to evaluate the cardiovascular influences of alpha1b-AR. METHODS AND RESULTS: In transgenic mice lacking alpha1-AR (KO) and their wild-type controls (WT), we evaluated blood pressure profile and cardiovascular remodeling induced by the chronic administration (18 days via osmotic pumps) of norepinephrine, angiotensin II, and subpressor doses of phenylephrine. Our results indicate that norepinephrine induced an increase in blood pressure levels only in WT mice. In contrast, the hypertensive state induced by angiotensin II was comparable between WT and KO mice. Phenylephrine did not modify blood pressure levels in either WT or KO mice. The cardiac hypertrophy and eutrophic vascular remodeling evoked by norepinephrine was observed only in WT mice, and this effect was independent of the hypertensive state because it was similar to that observed during subpressor phenylephrine infusion. Finally, the cardiac hypertrophy induced by thoracic aortic constriction was comparable between WT and KO mice. CONCLUSIONS: Our data demonstrate that the lack of alpha1b-AR protects from the chronic increase of arterial blood pressure induced by norepinephrine and concomitantly prevents cardiovascular remodeling evoked by adrenergic activation independently of blood pressure levels.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: The purpose of this study was to determine whether thoracic endovascular aortic repair (TEVAR) reduces death and morbidity compared with open surgical repair for descending thoracic aortic disease. BACKGROUND: The role of TEVAR versus open surgery remains unclear. Metaregression can be used to maximally inform adoption of new technologies by utilizing evidence from existing trials. METHODS: Data from comparative studies of TEVAR versus open repair of the descending aorta were combined through meta-analysis. Metaregression was performed to account for baseline risk factor imbalances, study design, and thoracic pathology. Due to significant heterogeneity, registry data were analyzed separately from comparative studies. RESULTS: Forty-two nonrandomized studies involving 5,888 patients were included (38 comparative studies, 4 registries). Patient characteristics were balanced except for age, as TEVAR patients were usually older than open surgery patients (p = 0.001). Registry data suggested overall perioperative complications were reduced. In comparative studies, all-cause mortality at 30 days (odds ratio [OR]: 0.44, 95% confidence interval [CI]: 0.33 to 0.59) and paraplegia (OR: 0.42, 95% CI: 0.28 to 0.63) were reduced for TEVAR versus open surgery. In addition, cardiac complications, transfusions, reoperation for bleeding, renal dysfunction, pneumonia, and length of stay were reduced. There was no significant difference in stroke, myocardial infarction, aortic reintervention, and mortality beyond 1 year. Metaregression to adjust for age imbalance, study design, and pathology did not materially change the results. CONCLUSIONS: Current data from nonrandomized studies suggest that TEVAR may reduce early death, paraplegia, renal insufficiency, transfusions, reoperation for bleeding, cardiac complications, pneumonia, and length of stay compared with open surgery. Sustained benefits on survival have not been proven.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To determine the lower limit of dose reduction with hybrid and fully iterative reconstruction algorithms in detection of endoleaks and in-stent thrombus of thoracic aorta with computed tomographic (CT) angiography by applying protocols with different tube energies and automated tube current modulation. MATERIALS AND METHODS: The calcification insert of an anthropomorphic cardiac phantom was replaced with an aortic aneurysm model containing a stent, simulated endoleaks, and an intraluminal thrombus. CT was performed at tube energies of 120, 100, and 80 kVp with incrementally increasing noise indexes (NIs) of 16, 25, 34, 43, 52, 61, and 70 and a 2.5-mm section thickness. NI directly controls radiation exposure; a higher NI allows for greater image noise and decreases radiation. Images were reconstructed with filtered back projection (FBP) and hybrid and fully iterative algorithms. Five radiologists independently analyzed lesion conspicuity to assess sensitivity and specificity. Mean attenuation (in Hounsfield units) and standard deviation were measured in the aorta to calculate signal-to-noise ratio (SNR). Attenuation and SNR of different protocols and algorithms were analyzed with analysis of variance or Welch test depending on data distribution. RESULTS: Both sensitivity and specificity were 100% for simulated lesions on images with 2.5-mm section thickness and an NI of 25 (3.45 mGy), 34 (1.83 mGy), or 43 (1.16 mGy) at 120 kVp; an NI of 34 (1.98 mGy), 43 (1.23 mGy), or 61 (0.61 mGy) at 100 kVp; and an NI of 43 (1.46 mGy) or 70 (0.54 mGy) at 80 kVp. SNR values showed similar results. With the fully iterative algorithm, mean attenuation of the aorta decreased significantly in reduced-dose protocols in comparison with control protocols at 100 kVp (311 HU at 16 NI vs 290 HU at 70 NI, P ≤ .0011) and 80 kVp (400 HU at 16 NI vs 369 HU at 70 NI, P ≤ .0007). CONCLUSION: Endoleaks and in-stent thrombus of thoracic aorta were detectable to 1.46 mGy (80 kVp) with FBP, 1.23 mGy (100 kVp) with the hybrid algorithm, and 0.54 mGy (80 kVp) with the fully iterative algorithm.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Suite à des essais cliniques randomisés démontrant l'efficacité du dépistage de l'anévrisme de l'aorte abdominale (AAA) par échographie, plusieurs recommandations ont été publiées dans de nombreux pays en faveur du dépistage dans une partie de la population générale. De plus, au-dede la rupture aortique, le dépistage d'un petit AAA semble être une bonne occasion d'appliquer les stratégies de prévention secondaire, permettant une amélioration globale du pronostic cardiovasculaire du patient. Ces recommandations sont cependant peu suivies; les campagnes de dépistage systématique sont rares, laissant la responsabilité du dépistage au médecin généraliste. Cet article se propose de discuter les raisons de la non-implantation du dépistage de l'AAA. [Abstract] Following the evidence of benefits of ultrasound screening for abdominal aorta aneurysms (AAA), several guidelines support this screening in population. Beyond the prompt diagnosis of AAA prior to its rupture of grim vital prognosis, small AAA can beconsidered as a prognostic marker for cardiovascular diseases (CVD). Yet, its detection is an opportunity for secondary prevention to reduce CVD mortality. Despite, these guidelines are poorly applied: systematic screening campaigns are infrequent, making the screening of family physicians responsibility. While the major benefit from this screening strategy is to reduce AAA-related death (but only trivial effect on long-term total mortality), this explains only partially the lack of guidelines implementation. The reasons of the poor implementation of these guidelines are discussed herein.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A cardiac-triggered free-breathing three-dimensional balanced fast field-echo projection magnetic resonance (MR) angiographic sequence with a two-dimensional pencil-beam aortic labeling pulse was developed for the renal arteries. For data acquisition during free breathing in eight healthy adults and seven consecutive patients with renal artery disease, real-time navigator technology was implemented. This technique allows high-spatial-resolution and high-contrast renal MR angiography and visualization of renal artery stenosis without exogenous contrast agent or breath hold. Initial promising results warrant larger clinical studies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

SUMMARY Inflammation has evolved as a mechanism to defend the body against invading microorganisms and to respond to injury. It requires the coordinated response of a large number of cell types from the whole organism in a time- and space-dependent fashion. This coordination involves several cell-cell communication mechanisms. Exchange of humoral mediators such as cytokines is a major one. Moreover, direct contact between cells happens and plays a primordial role, for example when macrophages present antigens to lymphocytes. Contact between endothelial cells and leucocytes occurs when the latter cross the blood vessel barrier and transmigrate to the inflammatory site. A particular way by which cells communicate with each other in the course of inflammation, which at this time starts to gain attention, is the intercellular communication mediated by gap junctions. Gap junctions are channels providing a direct pathway (i.e. without transit through the extracellular space) for the diffusion of small molecules between adjacent cells. This process is known as gap junctional intercellular communication (GJIC). The general aim of this thesis was to study a possible involvement of GJIC in the pathophysiology of inflammation. A first part of the work was dedicated to study the implication of GJIC in the modification of vascular endothelial function by inflammation. In a second part, we were interested in the possible role of GJIC in the transmigration of neutrophil polymorphonuclear leucocytes through the endothelium. The main positive finding of this work is that acute inflammation preferentially modulates the expression of connexin 40 (Cx40), a gap junction protein specifically expressed in vascular endothelium. The modulation could be towards overexpression (aortic endothelium of septic rats) or towards downregulation (acutely inflamed mouse lung). We put a lot of efforts in search of possible functions of these modulations, in two directions: a potential protective role of Cx40 increased expression against sepsis-induced endothelial dysfunction, and a facilitating role of Cx40 decreased expression in neutrophil transmigration. To pursue both directions, it seemed logical to study the impact of Cx40 deletion using knock-out mice. Concerning the potential protective role of Cx40 overexpression we encountered a roadblock as we observed, in the aorta, a Cx40 downregulation in wild type mouse whereas Cx40 was upregulated in the rat. Regarding the second direction and using an in vivo approach, we observed that pulmonary neutrophil transmigration was not affected by the genetic deletion of Cx40. In spite of their negative nature, these results are the very first ones regarding the potential implication of GJIC concerning leucocyte transmigration in vivo. Because this process involves such tight cell-cell physical contacts, the hypothesis for a role of GJIC remains attractive.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report on a patient with Marfan syndrome who presented a Stanford type B dissection of the descending thoracic aorta in late pregnancy. After a cesarean section, the patient presented a severe obstruction of the mesenteric superior artery. An endovascular fenestration was performed (balloon and guidewire based fenestration). Computed tomography (CT) angiography revealed an intussusception 'like' image of the abdominal aortic layers as a consequence of the fenestration procedure. Because of aneurismal progression in the abdominal aorta, surgical repair of the abdominal aorta and intussusception material removal was achieved six weeks later. The patient is currently in good condition. We conclude that the intussusception could be induced by a guidewire. This fenestration procedure is not recommended in patients with structural aortic disorders.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Normalization of the increased vascular nitric oxide (NO) generation with low doses of NG-nitro-L-arginine methyl ester (L-NAME) corrects the hemodynamic abnormalities of cirrhotic rats with ascites. We have undertaken this study to investigate the effect of the normalization of vascular NO production, as estimated by aortic cyclic guanosine monophosphate (cGMP) concentration and endothelial nitric oxide synthase (eNOS) protein expression in the aorta and mesenteric artery, on sodium and water excretion. Rats with carbon tetrachloride-induced cirrhosis and ascites were investigated using balance studies. The cirrhotic rats were separated into two groups, one receiving 0.5 mg/kg per day of L-NAME (CIR-NAME) during 7 d, whereas the other group (CIR) was administrated the same volume of vehicle. Two other groups of rats were used as controls, one group treated with L-NAME and another group receiving the same volume of vehicle. Sodium and water excretion was measured on days 0 and 7. On day 8, blood samples were collected for electrolyte and hormone measurements, and aorta and mesenteric arteries were harvested for cGMP determination and nitric oxide synthase (NOS) immunoblotting. Aortic cGMP and eNOS protein expression in the aorta and mesenteric artery were increased in CIR as compared with CIR-NAME. Both cirrhotic groups had a similar decrease in sodium excretion on day 0 (0.7 versus 0.6 mmol per day, NS) and a positive sodium balance (+0.9 versus +1.2 mmol per day, NS). On day 7, CIR-NAME rats had an increase in sodium excretion as compared with the CIR rats (sodium excretion: 2.4 versus 0.7 mmol per day, P < 0.001) and a negative sodium balance (-0.5 versus +0.8 mmol per day, P < 0.001). The excretion of a water load was also increased after L-NAME administration (from 28+/-5% to 65+/-7, P < 0.05). Plasma renin activity, aldosterone and arginine vasopressin were also significantly decreased in the CIR-NAME, as compared with the CIR rats. The results thus indicate that normalization of aortic cGMP and eNOS protein expression in vascular tissue is associated with increased sodium and water excretion in cirrhotic rats with ascites.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIMS: Changes in circulating brain-derived neurotrophic factor (BDNF) levels were reported in patients with or at risk for cardiovascular diseases associated with endothelial dysfunction, suggesting a link between BDNF and endothelial functionality. However, little is known on cardiovascular BDNF. Our aim was to investigate levels/localization, function, and relevance of cardiovascular BDNF. METHODS AND RESULTS: BDNF levels (western blotting) and localization (immunostaining) were assessed in the heart and aorta from rats with impaired (spontaneously hypertensive rats [SHR]), normal (Wistar Kyoto rats [WKY]), and improved (SHR and WKY subjected to physical training) endothelial function. BDNF levels were also measured in cultured endothelial cells (CECs) subjected to low and high shear stress. The cardiovascular effects of BDNF were investigated in isolated aortic rings and hearts. The results showed high BDNF levels in the heart and aorta, the expression being prominent in endothelial cells as compared with other cell types. Exogenous BDNF vasodilated aortic rings but changed neither coronary flow nor cardiac contractility. Hypertension was associated with decreased expression of BDNF in the endothelium, whereas physical training led to endothelial BDNF up-regulation not only in WKY but also in SHR. Exposure of CECs to high shear stress stimulated BDNF production and secretion. CONCLUSION: Cardiovascular BDNF is mainly localized within endothelial cells in which its expression is dependent on endothelial function. These results open new perspectives on the role of endothelial BDNF in cardiovascular health.