923 resultados para adjustable moment and rotation speed
Resumo:
Introduction. Gait becomes the individual independence for their daily activities. The functional deficit caused by central lesion as stroke, makes difficult this motor independence, mainly the locomotion. Objective. Analyze the kinematics gait in stroke patients. Method. It was included 8 patients with clinical diagnosis of stroke, 4 with hemiparesia on the right and 4 on the left. It was analyzed gait spatial-temporal parameters as: length, duration and average speed of the step, using the register in videotape and the software of image 6.3 Dvideow Barros. Results. All patients presented alterations in the kinematics standards of the gait, with lesser duration and length of step, and greater speed than normal subjects. Conclusion. The motor disorder caused by the central lesions produces alterations in the kinematics standards of the gait, in order to adapt the neuro-sensorial sequels, the demands of the task and the way where they live.
Resumo:
The aim of this paper is to verify the correlation between environmental indicators and behaviors expressed by laying hens kept in cages. The birds react to a severe environment through their behaviors, end the behaviors can be monitored to identify the birds' welfare conditions. The behaviors birds display ere the result of stress caused by the combination of environmental temperature, relative humidity, radiant heat, and air speed (environmental temperature being the most important). In order to check the influence of the environment, an experiment was carried out on a commercial poultry farm, located in the city of Bastos. The study was initiated in March 2007, during four non-consecutive weeks. The birds' behaviors were recorded using video, by cameras installed in the cages. The birds behaviors were identified and noted for the frequency of occurrence for each bird, and the average duration of each behavior (in seconds), using video samples of 15 minutes recorded from 1 PM to 4 PM. The environmental variables collected were: air temperature, concentration of ammonia, relative air humidity, velocity of the air, noise, roof temperature, and light intensity. The observed behaviors were: opening wings, stretching, threatening, ruffling feathers, drinking water, aggressive pecking, eating, running, lying down, stretching head out of the cage, preening, mounting and prostrating. Principal Components Analysis was used to determine associations between the behavior variables and environmental variables described above. In this experiment, there were no significant correlations between behavioral variables and environmental variables.
Resumo:
Standard Test Methods (e.g. ASTM, DIN) for materials characterization in general, and for fatigue in particular, do not contemplate specimens with complex geometries, as well as the combination of axial and in-plane bending loads in their methodologies. The present study refers to some patents and the new configuration or configurations of specimens (non-standardized by the status quo of test methods) and a device developed to induce axial and bending combined forces resultants from axial loads applied by any one test equipment (dynamic or monotonic) which possesses such limitation, towards obtaining more realistic results on the fatigue behavior, or even basic mechanical properties, from geometrically complex structures. Motivated by a specific and geometrically complex aeronautic structure (motor-cradle), non-standardized welded tubular specimens made from AISI 4130 steel were fatigue-tested at room temperature, by using a constant amplitude sinusoidal load of 20 Hz frequency, load ratio R = 0.1 with and without the above referred auxiliary fatigue apparatus. The results showed the fatigue apparatus was efficient for introducing higher stress concentration factor at the welded specimen joints, consequently reducing the fatigue strength when compared to other conditions. From the obtained results it is possible to infer that with small modifications the proposed apparatus will be capable to test a great variety of specimen configurations such as: squared tubes and plates with welded or melted junctions, as well as other materials such as aluminum, titanium, composites, polymeric, plastics, etc. © 2009 Bentham Science Publishers Ltd.
Resumo:
The current study evaluated equine gas exchange responses through spirometry, by measuring oxygen uptake (VO2), carbon dioxide production (VCO2), respiratory exchange ratio (R) and maximum oxygen uptake (VO2max) of Arabian horses during a standard incremental exercise test performed on a high-speed treadmill. Six clinically healthy Arabian horses were submitted to a standard incremental exercise test, performed on a high-speed treadmill at a 6% slope, and initial speed of 1,8 m.s-1 for 5 minutes, then 4,0 m.s-1 for 3 minutes, 6,0 m.s-1 for 2 minutes and 8,0 m.s-1, 9,0 m.s-1, 10,0 m.s-1 and 11,0 m.s-1 for one minute for each of these speed. The end of the exercise test was defined as the point in which the horse was no longer able to keep pace with the treadmill. Gas exchange was measured through respiratory analyses horse mask on the last 10 seconds at the end of each speed transition and at 1, 2 and 3 minutes after the end of the exercise, defined as experiment moments. During exercise, it was noticed an increase on both VO2 and VCO2 with linear relationship between exercise and speed. Arabian horses VO2max was 114,9 mL.kg-1.min-1. The respiratory exchange ratio increased over 1,0 by the speed of 9,0 m.s-1, indicating the preponderance of the anaerobic metabolism, and remains at a high level on the post-exercise period.
Resumo:
Aim. The purpose of this study was to compare the anaerobic threshold speed (AT) obtained from fixed lactate blood concentrations (AT 4 mM and AT 3.5 mM), lactate minimum speed (LM) and critical speed (CS), determined from different distances in fifteen Brazilian national level swimmers (10 boys = 14.8 ± 0.6 years old and 5 girls = 14.6 ±0.8 year-old). Methods. The tests to determine the AT 4 mM, AT 3.5 mM, LM and CS were performed in a 25 m swimming pool and consisted of 7 or 8 evaluations separated by 24-48 h intervals. Data were submitted to analysis of variance (ANOVA) for repeated measures, followed by the post hoc Scheffé test and Pearson correlation coefficients. Significance was set at P<0.01. Results. There were no significant differences among the values for AT 4 mM and CS1 (1.34 ± 0.05 vs. 1.33 ± 0.05 m.s -1, respectively). However, AT 4 mM and CS1 were significantly higher than AT 3.5 mM (1.28 ± 0.04 m.s -1), LM (1.27 ± 0.05 m.s -1), CS2 (1.26 ± 0.06 m.s -1), CS3 (1.27 ± 0.06 m.s -1) and CS4 (1.25 ± 0.07 m.s -1). There were no significant differences among the values for AT 3.5 mM, LM, CS2, CS3 and CS4. Conclusion. The results obtained in this study suggest that the anaerobic threshold determined by a fixed lactate concentration of 3.5 mM, as well as the LM and the CS methods determined by different distances, seem to be the most appropriate indexes for the evaluation of aerobic capacity in adolescent swimmers.
Resumo:
Includes bibliography
Resumo:
Incluye Bibliografía
Resumo:
The aim of this paper was to compare the dentin-pulp complex response to cavity preparation in human teeth using ultrasonic chemical vapor deposition (CVD) diamond tip and high-speed diamond bur. Class V buccal cavities were randomly prepared in 40 premolars from 14 patients aged 11 to 15 years. The cutting time was recorded and the cavities had the axial walls protected with gutta-percha and were filled with glass ionomer cement. The teeth were extracted at intervals of 0, 5, 10 and 20 days, and were decalcified, sectioned and stained by Hematoxylin & Eosin, Masson's Trichrome and Brown & Brenn techniques. The inflammatory response and cell disorganization were blindly evaluated by two examiners. The remaining dentin thickness (RDT) was measured by a linear scale using computer software. Statistical analysis by one-way ANOVA showed no statistically significant difference (P≤0.05) among the cavities prepared with either type of instrument, with mean RDT of 1132.50 mm. Cutting time and the pulp-dentin complex responses were analyzed statistically by Kruskal-Wallis and Dunn tests (P≤0.05). The ultrasonic CVD diamond tip took 5 times longer to prepare the cavities and there were no typical inflammatory pulp responses in cavities prepared with either type of cutting instrument, only mild to moderate cell disorganization was present. Even taking longer to cut the dental substrate, the ultrasonic CVD diamond tip produced similar pulp response compared to the conventional high-speed diamond bur.
Resumo:
Taking into account the bone repair process in pigs has shown a greater similarity among the histological variables studied compared to other biological models, the present study has as its aim to evaluate the histological bone repair process of osteotomy performed on alveolar and extra-alveolar bones, using drilling tools with liquid refrigeration. Material and method: Eighteen Large White pigs weighing between 20 and 25 Kg were divided into three groups of six animals in order to evaluate the osteotomy repairs with low and high speed in the alveolar bone and threes in the extra-alveolar area, study periods of 7, 14 and 28 days. Results: It was observed that in the alveolar bone at the postoperative times of 14 and 28 days, the best repair results were in the osteotomy performed with low speed, while in the 7 day postoperative period, the results with high speed were slightly better, in alveolar areas as well as extra-alveolar areas. There no statistically significant differences between the alveolar and extra-alveolar bone repair process. Conclusions: The repair process, by means of microscopic analysis in the alveolar and extra-alveolar areas, are similar with better results observed in osteotomies performed with low speed drills in the 14 and 28 day study periods, and at 7 days postoperative the results with high speed drills and refrigeration were slightly better. Research works using pigs as an animal model are perfectly viable. © 2011 SECOM.
Resumo:
The propagation of 'juçara' and 'açaí' is done by seeds, but there is a great desuniformity in the germination process. In this way, the objective of this study was to verify the effect of temperature, mechanical scarification and substrate on seed germination of both species. Two experiments were conducted in a completely randomized design, with four replications each consisting of 25 seeds. The first was conducted with 14 treatments in factorial scheme 7 x 2, seven temperatures (20, 25, 30, 35, 20-30 and 25-35 °C and natural condition), with and without mechanical scarification. The second was constituted of eight treatments in factorial scheme 4 x 2, four substrates (sand, vermiculite, coconut fiber and soil + manure), with and without mechanical scarification. Seeds of 'juçara' palm present the highest mean percentage and germination speed index in alternating temperatures of 20-30 and 25-35 °C and natural condition and in substrates sand, vermiculite and coconut fiber. Temperatures of 30, 35, 20-30 and 25-35 °C and natural condition in all substrates tested were the most favorable condition for 'açai' seeds. The scarification of the seeds was favorable to the germination process of 'juçara' whereas the seeds of açaí does not need to be scarified.
Resumo:
The amount and timing of nitrogen application can favor seed quality, such as increasing protein content, which is an important constituent for embryo development. The objective of this study was to evaluate the physiological quality of sweet corn seeds collected from plants cultivated with different dosages and timings of nitrogen top-dressing applications. Seeds of the BR 400 variety (Super Sweet) were used obtained from plants submitted to dosages of 0, 40, 80 and 120kg ha -1 of N in two top-dressing applications (vegetative and reproductive stages). The weight of 100 grains, germination, first count of germination test, dry weight of normal seedlings from the germination test, seedling growth, cold test, accelerated aging, tetrazolium vigor and electric conductivity and emergency speed rate were determined. Data was submitted to an analysis of variance using the F-test at the 5% level and second degree regression analysis. The dosage and time of application of nitrogen top-dressing did not affect seed weight or the germination of sweet corn seeds. An increase of the N top-dressing dosage, applied in the vegetative stage reduced the length of the aerial part, the root and the whole seedling.
Resumo:
[Purpose] The purpose of this study was to verify the effect on body sway during quiet standing of the habitual weight carried by students in a backpack. [Subjects] Forty-six students between the ages of 8 and 14 years volunteered. [Method] The percentage of body weight (% BW) of each student's backpack was calculated and the students were separated into three groups based on the results: Group A (0-7% BW), Group B (7.01-14% BW) and Group C (14.01-21%BW). [Results] The use of the backpack increased the area of the CoP sway, displacement and mean speed of the CoP data in the antero-posterior and medial-lateral directions in Group C. [Conclusion] Therefore, observed responses in the body posture changes caused by the weight of the backpack were similar to those reported in other studies conducted with different methodos of investigation.
Resumo:
Feathers are rich in amino acids and can be employed as a dietary protein supplement for animal feed. Microbial degradation is an alternative technology for improving the nutritional value of feathers. Other potential applications of keratinase include use in the leather industry, detergents and medicine as well as the pharmaceutical for the treatment of acne, psoriasis and calluses. A new keratinolytic enzyme production bacterium was isolated from a poultry processing plant. To improve keratinase yield, statistically based experimental designs were applied to optimize three significant variables: temperature, substrate concentration (feathers) and agitation speed. Response surface methodology demonstrated an increase in keratinolytic activity at temperature, agitation speed and substrate concentration of 26.6°C, 150 rpm and 2%, respectively. Liquid chromatography revealed the release of amino acids in the Bacillus amyloliquefaciens culture broth, thereby demonstrating the potential of feather meal in the animal feed industry. © Global Science Publications.
Resumo:
The aim of this study was to evaluate the influence of 2 different surface polishing procedures - glazing (GZ) and manual polishing (MP) - on the roughness of ceramics processed by computer-aided design/computer-aided manufacturing (CAD/CAM) and conventional systems (stratification technique). Eighty ceramic discs (diameter: 8 mm, thickness: 1 mm) were prepared and divided among 8 groups (n = 10) according to the type of ceramic disc and polishing method: 4 GZ and 4 MP. Specimens were glazed according to each manufacturer's recommendations. Two silicone polishing points were used on the ceramic surface for manual polishing. Roughness was measured using a surface roughness tester. The roughness measurements were made along a distance of 2 mm on the sample surface and the speed of reading was 0.1 mm/s. Three measurements were taken for each sample. The data (μm) were statistically analyzed using analysis of variance (ANOVA) and Tukey's test (α = 0.05). Qualitative analysis was performed using scanning electron microscopy (SEM). The mean (± SD) roughness values obtained for GZ were: 1.1 ± 0.40 μm; 1.0 ± 0.31 μm; 1.6 ± 0.31 μm; and 2.2 ± 0.73 μm. For MP, the mean values were: 0.66 ± 0.13 μm; 0.43 ± 0.14 μm; 1.6 ± 0.55 μm; and 2.0 ± 0.63 μm. The mean roughness values were significantly affected by the ceramic type (P = 0.0001) and polishing technique (P = 0.0047). The SEM images confirmed the roughness data. The manually polished glass CAD/CAM ceramics promoted lower surface roughness than did the glazed feldspathic dental ceramics.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)