991 resultados para Vision Screening


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background

Diabetic macular oedema (DMO) is a thickening of the central retina, or the macula, and is associated with long-term visual loss in people with diabetic retinopathy (DR). Clinically significant macular oedema (CSMO) is the most severe form of DMO. Almost 30 years ago, the Early Treatment Diabetic Retinopathy Study (ETDRS) found that CSMO, diagnosed by means of stereoscopic fundus photography, leads to moderate visual loss in one of four people within three years. It also showed that grid or focal laser photocoagulation to the macula halves this risk. Recently, intravitreal injection of antiangiogenic drugs has also been used to try to improve vision in people with macular oedema due to DR.Optical coherence tomography (OCT) is based on optical reflectivity and is able to image retinal thickness and structure producing cross-sectional and three-dimensional images of the central retina. It is widely used because it provides objective and quantitative assessment of macular oedema, unlike the subjectivity of fundus biomicroscopic assessment which is routinely used by ophthalmologists instead of photography. Optical coherence tomography is also used for quantitative follow-up of the effects of treatment of CSMO.

Objectives

To determine the diagnostic accuracy of OCT for detecting DMO and CSMO, defined according to ETDRS in 1985, in patients referred to ophthalmologists after DR is detected. In the update of this review we also aimed to assess whether OCT might be considered the new reference standard for detecting DMO.

Search methods

We searched the Cochrane Database of Systematic Reviews (CDSR), the Database of Abstracts of Reviews of Effects (DARE), the Health Technology Assessment Database (HTA) and the NHS Economic Evaluation Database (NHSEED) (The Cochrane Library 2013, Issue 5), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to June 2013), EMBASE (January 1950 to June 2013), Web of Science Conference Proceedings Citation Index - Science (CPCI-S) (January 1990 to June 2013), BIOSIS Previews (January 1969 to June 2013), MEDION and the Aggressive Research Intelligence Facility database (ARIF). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 25 June 2013. We checked bibliographies of relevant studies for additional references.

Selection Criteria

We selected studies that assessed the diagnostic accuracy of any OCT model for detecting DMO or CSMO in patients with DR who were referred to eye clinics. Diabetic macular oedema and CSMO were diagnosed by means of fundus biomicroscopy by ophthalmologists or stereophotography by ophthalmologists or other trained personnel.

Data collection and analysis

Three authors independently extracted data on study characteristics and measures of accuracy. We assessed data using random-effects hierarchical sROC meta-analysis models.

Main results

We included 10 studies (830 participants, 1387 eyes), published between 1998 and 2012. Prevalence of CSMO was 19% to 65% (median 50%) in nine studies with CSMO as the target condition. Study quality was often unclear or at high risk of bias for QUADAS 2 items, specifically regarding study population selection and the exclusion of participants with poor quality images. Applicablity was unclear in all studies since professionals referring patients and results of prior testing were not reported. There was a specific 'unit of analysis' issue because both eyes of the majority of participants were included in the analyses as if they were independent.In nine studies providing data on CSMO (759 participants, 1303 eyes), pooled sensitivity was 0.78 (95% confidence interval (CI) 0.72 to 0.83) and specificity was 0.86 (95% CI 0.76 to 0.93). The median central retinal thickness cut-off we selected for data extraction was 250 µm (range 230 µm to 300 µm). Central CSMO was the target condition in all but two studies and thus our results cannot be applied to non-central CSMO.Data from three studies reporting accuracy for detection of DMO (180 participants, 343 eyes) were not pooled. Sensitivities and specificities were about 0.80 in two studies and were both 1.00 in the third study.Since this review was conceived, the role of OCT has changed and has become a key ingredient of decision-making at all levels of ophthalmic care in this field. Moreover, disagreements between OCT and fundus examination are informative, especially false positives which are referred to as subclinical DMO and are at higher risk of developing clinical CSMO.

Authors' conclusions

Using retinal thickness thresholds lower than 300 µm and ophthalmologist's fundus assessment as reference standard, central retinal thickness measured with OCT was not sufficiently accurate to diagnose the central type of CSMO in patients with DR referred to retina clinics. However, at least OCT false positives are generally cases of subclinical DMO that cannot be detected clinically but still suffer from increased risk of disease progression. Therefore, the increasing availability of OCT devices, together with their precision and the ability to inform on retinal layer structure, now make OCT widely recognised as the new reference standard for assessment of DMO, even in some screening settings. Thus, this review will not be updated further.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Antimicrobial residues found to be present in milk can have both health and economic impacts. For these reasons, the widespread routine testing of milk is required. Due to delays with sample handling and test scheduling, laboratory-based tests are not always suited for making decisions about raw material intake and product release, especially when samples require shipping to a central testing facility. Therefore, rapid on-site screening tests that can produce results within a matter of minutes are required to facilitate rapid intake and product release processes. Such tests must be simple for use by non-technical staff. There is increasing momentum towards the development and implementation of multiplexing tests that can detect a range of important antimicrobial residues simultaneously. A simple in situ multiplexed planar waveguide device that can simultaneously detect chloramphenicol, streptomycin and desfuroylceftiofur in raw dairy milk, without sample preparation, has been developed. Samples are simply mixed with antibody prior to an aliquot being passed through the detection cartridge for 5 min before reading on a field-deployable portable instrument. Multiplexed calibration curves were produced in both buffer and raw milk. Buffer curves, for chloramphenicol, streptomycin and desfuroylceftiofur, showed linear ranges (inhibitory concentration (IC)20–IC80) of 0.1–0.9, 3–129 and 12–26 ng/ml, whilst linear range in milk was 0.13–0.74, 11–376 and 2–12 ng/ml, respectively, thus meeting European legislated concentration requirements for both chloramphenicol and streptomycin, in milk, without the need for any sample preparation. Desfuroylceftiofur-contaminated samples require only simple sample dilution to bring positive samples within the range of quantification. Assay repeatability and reproducibility were lower than 12 coefficient of variation (%CV), whilst blank raw milk samples (n = 9) showed repeatability ranging between 4.2 and 8.1 %CV when measured on all three calibration curves.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Invited talk, representing the Royal Society

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper explores the application of semi-qualitative probabilistic networks (SQPNs) that combine numeric and qualitative information to computer vision problems. Our version of SQPN allows qualitative influences and imprecise probability measures using intervals. We describe an Imprecise Dirichlet model for parameter learning and an iterative algorithm for evaluating posterior probabilities, maximum a posteriori and most probable explanations. Experiments on facial expression recognition and image segmentation problems are performed using real data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bovine Respiratory Disease (BRD) is considered to be one of the most significant causes of economic loss in cattle worldwide. The disease has multifactorial aetiology, where viral induced respiratory damage can predispose animals to developing secondary bacterial infections. Accurate identification of viral infected animals prior to the onset of bacterial infection is necessary to reduce the overuse of antimicrobial treatments and minimize further economic losses from reduced production capacity and death. This research focuses on Bovine Parainfluenza Virus Type 3 (BPIV-3), one of the viruses involved in generating BRD. Vaccination measures for BPIV-3 can induce a level of immunity preventing disease progression, however, not all animals respond equally and immunization can complicate disease diagnosis. Alternative diagnostic approaches are required to identify animals which fail to respond to vaccination during infection outbreaks and are therefore likely to be more susceptible to secondary bacterial infections. Mass spectrometry based metabolomics was employed to identify plasma markers capable of differentiating between vaccinated and non-vaccinated calves after challenge with BPIV-3. Differentiation of vaccinated and non-vaccinated study groups (n=6) was possible as early as day 2 post-BPIV-3 challenge up until day 20 using a panel of potential metabolite markers. This study illustrates the potential for metabolomics to provide more detailed information on animal vaccination status that could be used to develop tools for improved herd health management, reduce economic loss through rapid identification and isolation of animals without immune protection (improving herd level immunity) and help reduce the usage of antimicrobial therapeutic treatments in animals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND:
It is compulsory that domestic football/soccer teams in UEFA competitions organise players' pre-participation medicals. Although screening guidelines have been established, these remain controversial. The findings of medical examinations can have lasting consequences for athletes and doctors. No previous studies have reported UEFA pre-participation screening results in semi-professional footballers. This study aims to further knowledge regarding 'normal' data in this population.

METHOD:
Retrospective audit and analysis of records of pre-season medicals for all male first-team players at one semi-professional Northern Ireland Premiership team between 2009-2012. Medicals were conducted by the club doctor following the UEFA proforma. Height, weight, blood pressure (BP), full blood count (FBC), dipstick urinalysis and resting electrocardiogram (ECG) were conducted by an independent nurse. Only one ECG must be documented during a player's career; other tests are repeated yearly.

RESULTS:
89 medicals from 47 players (6 goalkeepers, 11 defenders, 22 midfielders and 8 attackers; mean age 25.0 years (SD 4.86)) were reviewed. Mean height of the players was 179.3 cm (SD 5.90) with a mean weight of 77.6 kg (SD 10.5). Of 89 urine dipsticks, 7 were positive for protein; all 7 were normal on repeat testing following 48 hours of rest. Of 40 ECGs (mean ventricular rate 61.2 bpm (SD 11.6)), one was referred to cardiology (right bundle branch block; prolonged Q-T interval). No players were excluded from participation.

CONCLUSIONS:
This study provides important information about 'normal' values in a population of semi-professional footballers. Urinalysis showing protein is not uncommon but is likely to be normal on repeat testing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A single-step lateral flow immunoassay (LFIA) was developed and validated for the rapid screening of paralytic shellfish toxins (PSTs) from a variety of shellfish species, at concentrations relevant to regulatory limits of 800 μg STX-diHCl equivalents/kg shellfish meat. A simple aqueous extraction protocol was performed within several minutes from sample homogenate. The qualitative result was generated after a 5 min run time using a portable reader which removed subjectivity from data interpretation. The test was designed to generate noncompliant results with samples containing approximately 800 μg of STX-diHCl/kg. The cross-reactivities in relation to STX, expressed as mean ± SD, were as follows: NEO: 128.9% ± 29%; GTX1&4: 5.7% ± 1.5%; GTX2&3: 23.4% ± 10.4%; dcSTX: 55.6% ± 10.9%; dcNEO: 28.0% ± 8.9%; dcGTX2&3: 8.3% ± 2.7%; C1&C2: 3.1% ± 1.2%; GTX5: 23.3% ± 14.4% (n = 5 LFIA lots). There were no indications of matrix effects from the different samples evaluated (mussels, scallops, oysters, clams, cockles) nor interference from other shellfish toxins (domoic acid, okadaic acid group). Naturally contaminated sample evaluations showed no false negative results were generated from a variety of different samples and profiles (n = 23), in comparison to reference methods (MBA method 959.08, LC-FD method 2005.06). External laboratory evaluations of naturally contaminated samples (n = 39) indicated good correlation with reference methods (MBA, LC-FD). This is the first LFIA which has been shown, through rigorous validation, to have the ability to detect most major PSTs in a reliable manner and will be a huge benefit to both industry and regulators, who need to perform rapid and reliable testing to ensure shellfish are safe to eat.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: Cataract surgery is one of the most common surgeries performed, but its overuse has been reported. The threshold for cataract surgery has become increasingly lenient; therefore, the selection process and surgical need has been questioned. The aim of this study was to evaluate the changes associated with cataract surgery in patient-reported vision-related quality of life (VR-QoL).

Methods: A prospective cohort study was conducted. Consecutive patients referred to cataract clinics in an NHS unit in Scotland were identified. Those listed for surgery were invited to complete a validated questionnaire (TyPE) to measure VR-QoL pre- and post-operatively. TyPE has five different domains (near vision, distance vision, daytime driving, night-time driving, and glare) and a global score of vision. The influence of pre-operative visual acuity (VA) levels, vision, and lens status of the fellow eye on changes in VR-QoL were explored. 

Results: A total of 320 listed patients were approached, of whom 36 were excluded. Among the 284 enrolled patients, 229 (81%) returned the questionnaire after surgery. Results revealed that the mean overall vision improved, as reported by patients. Improvements were also seen in all sub-domains of the questionnaire.

Conclusion: The majority of patients appear to have improvement in patient-reported VR-QoL, including those with good pre-operative VA and previous surgery to the fellow eye. VA thresholds may not capture the effects of the quality of life on patients. This information can assist clinicians to make more informed decisions when debating over the benefits of listing a patient for cataract extraction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: This article uses conventional and newly extended solubility parameter (δ) methods to identify polymeric materials capable of forming amorphous dispersions with itraconazole (itz). Methods: Combinations of itz and Soluplus, Eudragit E PO (EPO), Kollidon 17PF (17PF) or Kollidon VA64 (VA64) were prepared as amorphous solid dispersions using quench cooling and hot melt extrusion. Storage stability was evaluated under a range of conditions using differential scanning calorimetry and powder X-ray diffraction. Key findings: The rank order of itz miscibility with polymers using both conventional and novel δ-based approaches was 17PF > VA64 > Soluplus > EPO, and the application of the Flory–Huggins lattice model to itz–excipient binary systems corroborated the findings. The solid-state characterisation analyses of the formulations manufactured by melt extrusion correlated well with pre-formulation screening. Long-term storage studies showed that the physical stability of 17PF/vitamin E TPGS–itz was poor compared with Soluplus and VA64 formulations, and for EPO/itz systems variation in stability may be observed depending on the preparation method. Conclusion: Results have demonstrated that although δ-based screening may be useful in predicting the initial state of amorphous solid dispersions, assessment of the physical behaviour of the formulations at relevant temperatures may be more appropriate for the successful development of commercially acceptable amorphous drug products.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Title
Visual and deaf awareness training is it app.ropriate
Purpose
Some of our most vulnerable patients have a sensory deficit. An app which focused on patients with a vision and/or hearing loss was developed for healthcare students. The intent was to embed the core values necessary for students to provide appropriate care for patients with a sensory deficit.
Setting
Queen’s University Belfast, School of Nursing and Midwifery.
Methods
Stage 1
A review of current sensory awareness training in the United Kingdom
Stage 2
Application for funding
Stage 3
Development of a teaching tool template with the essential aspects required for sensory awareness training
Stage 4
Collaboration with others: Royal National Institute for the Blind, Action on Hearing Loss, Computer technician.
Stage 5
Production and transfer of multimedia outputs onto a software application system.
Stage 6
App Piloted with a sample of lecturers (n=5), undergraduate nursing students (n=20), service users (n=5)
Stage 7
Editing
Stage 8
App made available to all undergraduate nursing students
Stage 9
App evaluation (n=300)



Results
Overall nursing students positively evaluated the app, 100% of students rated the app between good and excellent. Qualitative evidence from service users and practice partnerships was extremely positive:
"At last I feel listened too in respect to my hearing loss and empowered. I don't feel like I am complaining I am actually helping to create something which should benefit staff and all of us with a hearing or vision loss". Patient
“Very insightful into the lives of those with a disability will be so useful in practice as an aid to jog my memory". 1st year nursing student
Conclusion
It is hoped that further evaluation and implementation of the app will show an improved quality to the care delivered to those with a sensory deficit. We believe that by working in partnership with service users we have helped to create an innovative tool that benefits both staff and patients.
Financial disclosure Yes
Funding of £2700 was awarded in 2014 through the Martha McMenamin Memorial Northern Ireland Scholarship.