970 resultados para Valve Repair
Resumo:
PURPOSE: To compare two techniques used to create a larger animal model of venous valve incompetence. MATERIALS AND METHODS: To achieve vein dilatation as the primary cause of valve incompetence, common carotid jugular vein (JV) fistulas were created and optional filters were placed into the JV of sheep. Altogether, nine inferior vena cava filters were placed in three sheep in two stages. Six filters were placed caudal to the most caudal JV valve in three sheep and removed 6 weeks later. Then, three filters were placed across the most caudal valve in two sheep with competent valves and removed 3 weeks later. A common carotid artery-JV fistula was created in three sheep and followed-up for 1-3 weeks. Ascending and descending venograms were obtained to determine the JV sizes and function of their valves. The JVs removed at necropsy were studied with venoscopy. RESULTS: Only one of the six JVs with filters caudal to the most caudal valve had incompetent valves after filter removal at 6 weeks. In addition, only one of three JVs with the filter across the valve had incompetent valves after filter removal at 3 weeks. At 1-3-week follow-up of the group with common carotid artery-JV fistula, all three JVs had incompetent valves in the cephalad vein portion, but only one JV had an incompetent valve in its caudal portion. At venoscopy, the incompetent valves showed various degrees of damage ranging from shortening to the destruction of valve leaflets. CONCLUSION: Dilation of the valve annulus with a removable vena cava filter failed to produce valve incompetence. The promising results with the common carotid artery-JV fistula justify further detailed research.
Percutaneous autologous venous valve transplantation: short-term feasibility study in an ovine model
Resumo:
BACKGROUND: Limited experience with bioprosthetic venous valve percutaneously inserted into femoral veins in 15 patients has been promising in short-term results only to show disappointing long-term results. Percutaneous autogenous venous valve (PAVV) transplantation was explored in an ovine model as a possible alternative treatment. METHODS: PAVV consisted of a vein segment containing a valve that was attached to a stent template. The stent templates (n = 9) were designed and hand made in our research laboratory. They consist of two stainless steel square stents 13 or 15 mm in diameter to fit the ovine jugular veins (JV), which ranges from 10 to 15 mm in diameter. A valve-containing segment of JV was harvested and attached with sutures and barbs inside the stent template (n = 9). The valve devices were then manually folded and front loaded inside the 4 cm chamber of the 13F delivery sheath and delivered into the contralateral JV by femoral vein approach. Transplanted PAVVs were studied by immediate and 3 months venograms. Animals were euthanized at 3 months, and jugular veins harvested to perform angioscopic evaluations in vitro. RESULTS: PAVV transplantation was successful in all nine animals. Good valve function with no reflux was observed on immediate and 3 months venograms in eight valves. The transplanted maximal JV diameter ranged from 10.2 mm to 15.4 mm (mean 13.1 +/- 1.5 mm). Venoscopic examination revealed intact, flexible, nonthickened valve leaflets in eight specimens. One PAVV exhibited normal function of one leaflet only; the other cusp was accidentally cut during the transplantation procedure. All transplanted autologous valves were free of thrombus and incorporated into the vein wall of the host vessel. CONCLUSION: This study demonstrated that autogenous valve transplants remained patent and competent without long-term anticoagulation for up to 3 months. The percutaneous autogenous venous valve may provide in future minimally invasive treatment for patients with chronic deep venous insufficiency, but long-term studies need to be done to document its continued patency and function.
Resumo:
Percutaneous valve replacement for severe aortic stenosis has shown to be an alternative treatment option for non-surgical candidates. We report on the first successful valve in valve procedure in an 80-year-old patient with a severe regurgitation of a degenerated aortic bioprosthesis using the Corevalve Revalving system.
Resumo:
OBJECTIVES: We sought to determine both the procedural performance and safety of percutaneous implantation of the second (21-French [F])- and third (18-F)-generation CoreValve aortic valve prosthesis (CoreValve Inc., Irvine, California). BACKGROUND: Percutaneous aortic valve replacement represents an emerging alternative therapy for high-risk and inoperable patients with severe symptomatic aortic valve stenosis. METHODS: Patients with: 1) symptomatic, severe aortic valve stenosis (area <1 cm2); 2) age > or =80 years with a logistic EuroSCORE > or =20% (21-F group) or age > or =75 years with a logistic EuroSCORE > or =15% (18-F group); or 3) age > or =65 years plus additional prespecified risk factors were included. Introduction of the 18-F device enabled the transition from a multidisciplinary approach involving general anesthesia, surgical cut-down, and cardiopulmonary bypass to a truly percutaneous approach under local anesthesia without hemodynamic support. RESULTS: A total of 86 patients (21-F, n = 50; 18-F, n = 36) with a mean valve area of 0.66 +/- 0.19 cm2 (21-F) and 0.54 +/- 0.15 cm2 (18-F), a mean age of 81.3 +/- 5.2 years (21-F) and 83.4 +/- 6.7 years (18-F), and a mean logistic EuroSCORE of 23.4 +/- 13.5% (21-F) and 19.1 +/- 11.1% (18-F) were recruited. Acute device success was 88%. Successful device implantation resulted in a marked reduction of aortic transvalvular gradients (mean pre 43.7 mm Hg vs. post 9.0 mm Hg, p < 0.001) with aortic regurgitation grade remaining unchanged. Acute procedural success rate was 74% (21-F: 78%; 18-F: 69%). Procedural mortality was 6%. Overall 30-day mortality rate was 12%; the combined rate of death, stroke, and myocardial infarction was 22%. CONCLUSIONS: Treatment of severe aortic valve stenosis in high-risk patients with percutaneous implantation of the CoreValve prosthesis is feasible and associated with a lower mortality rate than predicted by risk algorithms.
Resumo:
BACKGROUND: Purpose of this study was to compare the correlation of statin use with long-term mortality in patients with abdominal (AAA) and thoracic aortic aneurysm (TAA). PATIENTS AND METHODS: We compared long-term survival of 731 AAA and 59 TAA patients undergoing elective endovascular repair (EVAR). Kaplan-Meier survival curves were compared by the log-rank method. Propensity score-adjusted multivariable logistic regression models were used to determine independent associations of statin use on vital status after EVAR. RESULTS: Statin use was associated with decreased long-term mortality in AAA patients in bivariate and multivariable regression analysis, in which the effect of propensity to receive a statin was considered (adjusted HR: .613, 95%-CI: .379- .993, p = .047) whereas mortality of TAA patients was not associated with use of statins (adjusted HR: 1.795, 95%-CI: .147 -21.942, p = .647). CONCLUSIONS: Use of statins is an independent predictor of decreased mortality after elective EVAR in AAA, but not in TAA patients. These findings indirectly support the concept of a distinct pathogenesis of AAA and TAA.
Resumo:
Continuing aortic neck dilatation, most probably an expression of ongoing aneurysmal wall degeneration of the infrarenal aortic segment, has been shown to seriously impair clinical results after endovascular abdominal aortic aneurysm repair. However, conflicting data on the extent and clinical relevance on this observation have recently been published. This article reviews the recent literature, summarizing our current understanding of the role of aortic neck dilatation after open surgical and endovascular abdominal aortic aneurysm repair. In addition, differences in methodology of studies on aortic neck dilatation are highlighted.
Resumo:
PURPOSE: To compare clinical outcomes of endovascular and open aortic repair of abdominal aortic aneurysms (AAAs) in young patients at low risk. It was hypothesized that endovascular aneurysm repair (EVAR) compares favorably with open aneurysm repair (OAR) in these patients. MATERIALS AND METHODS: Twenty-five patients aged 65 years or younger with a low perioperative surgical risk profile underwent EVAR at a single institution between April 1994 and May 2007 (23 men; mean age, 62 years+/-2.8). A sex- and risk-matched control group of 25 consecutive patients aged 65 years or younger who underwent OAR was used as a control group (23 men; mean age, 59 years+/-3.9). Patient outcomes and complications were classified according to Society of Vascular Surgery/International Society for Cardiovascular Surgery reporting standards. RESULTS: Mean follow-up times were 7.1 years+/-3.2 after EVAR and 5.9 years+/-1.8 after OAR (P=.1020). Total complication rates were 20% after EVAR and 52% after OAR (P=.0378), and all complications were mild or moderate. Mean intensive care unit times were 0.2 days+/-0.4 after EVAR and 1.1 days+/-0.4 after OAR (P<.0001) and mean lengths of hospital stay were 2.3 days+/-1.0 after EVAR and 5.0 days+/-2.1 after OAR (P<.0001). Cumulative rates of long-term patient survival did not differ between EVAR and OAR (P=.144). No AAA-related deaths or aortoiliac ruptures occurred during follow-up for EVAR and OAR. In addition, no surgical conversions were necessary in EVAR recipients. Cumulative rates of freedom from secondary procedures were not significantly different between the EVAR and OAR groups (P=.418). Within a multivariable Cox proportional-hazards analysis adjusted for patient age, maximum AAA diameter, and cardiac risk score, all-cause mortality rates (odds ratio [OR], 0.125; 95% CI, 0.010-1.493; P=.100) and need for secondary procedures (OR, 5.014; 95% CI, 0.325-77.410; P=.537) were not different between EVAR and OAR. CONCLUSIONS: Results from this observational study indicate that EVAR offers a favorable alternative to OAR in young patients at low risk.
Resumo:
AIMS: To describe the procedural performance and 30-day outcomes following implantation using the 18 Fr CoreValve Revalving System (CRS) as part of the multicentre, expanded evaluation registry, 1-year after obtaining CE mark approval. METHODS AND RESULTS: Patients with symptomatic severe aortic stenosis and logistic Euroscore > or =15%, or age > or =75 years, or age > or =65 years associated with pre-defined risk factors, and for whom a physician proctor and a clinical specialist were in attendance during the implantation and who collected the clinical data, were included. From April 2007, to April 2008, 646 patients with a mean age of 81 +/- 6.6 years, mean aortic valve area 0.6 +/- 0.2 cm2, and logistic EuroSCORE of 23.1 +/- 13.8% were recruited. After valve implantation, the mean transaortic valve gradient decreased from 49.4 +/- 13.9 to 3 +/- 2 mmHg. All patients had paravalvular aortic regurgitation < or = grade 2. The rate of procedural success was 97%. The procedural mortality rate was 1.5%. At 30 days, the all-cause mortality rate (i.e, including procedural) was 8% and the combined rate of death, stroke and myocardial infarction was 9.3%. CONCLUSIONS: The results of this study demonstrate the high rate of procedural success and a low 30-day mortality in a large cohort of high-risk patients undergoing transcatheter aortic valve implantation (TAVI) with the CRS.
Resumo:
The rehabilitation of concrete structures, especially concrete bridge decks, is a major challenge for transportation agencies in the United States. Often, the most appropriate strategy to preserve or rehabilitate these structures is to provide some form of a protective coating or barrier. These surface treatments have typically been some form of polymer, asphalt, or low-permeability concrete, but the application of UHPC has shown promise for this application mainly due to its negligible permeability, but also as a result of its excellent mechanical properties, self-consolidating nature, rapid gain strength, and minimal creep and shrinkage characteristics. However, for widespread acceptance, durability and performance of the composite system must be fully understood, specifically the bond between UHPC and NSC often used in bridge decks. It is essential that the bond offers enough strength to resist the stress due to mechanical loading or thermal effects, while also maintaining an extended service-life performance. This report attempts to assess the bond strength between UHPC and NSC under different loading configurations. Different variables, such as roughness degree of the concrete substrates, age of bond, exposure to freeze-thaw cycles and wetting conditions of the concrete substrate, were included in this study. The combination of splitting tensile test with 0, 300, 600 and 900 freeze-thaw cycles was carried out to assess the bond performance under severe ambient conditions. The slant-shear test was utilized with different interface angles to provide a wide understanding of the bond performance under different combinations of compression and shear stresses. The pull-off test is the most accepted method to evaluate the bond strength in the field. This test which studies the direct tensile strength of the bond, the most severe loading condition, was used to provide data that can be correlated with the other tests that only can be used in the laboratory. The experimental program showed that the bond performance between UHPC and NSC is successful, as the strength regardless the different degree of roughness of the concrete substrate, the age of the composite specimens, the exposure to freeze-thaw cycles and the different loading configurations, is greater than that of concrete substrate and largely satisfies with ACI 546.3R-06.
Resumo:
The main purpose of this project is to understand the process of engine simulation using the open source CFD code called KIVA. This report mainly discusses the simulation of the 4-valve Pentroof engine through KIVA 3VR2. KIVA is an open source FORTRAN code which is used to solve the fluid flow field in the engines with the transient 2D and 3D chemically reactive flow with spray. It also focuses on the complete procedure to simulate an engine cycle starting from pre- processing until the final results. This report will serve a handbook for the using the KIVA code.
Resumo:
Various treatment options for deep cartilage defects are presently available. The efficacy of bone marrow stimulation with microfracture, of mosaicplasty and of various autologous chondrocyte implantation (ACI) techniques has been subject to numerous studies recently. Magnetic resonance imaging (MRI) has gained a major role in the assessment of cartilage repair. The introduction of high-field MRI to clinical routine makes high resolution and three-dimensional imaging readily available. New quantitative MRI techniques that directly visualize the molecular structure of cartilage may further advance our understanding of cartilage repair. The clinical evaluation of cartilage repair tissue is a complex issue, and MR imaging will become increasingly important both in research and in clinical routine. This article reviews the clinical aspects of microfracture, mosaicplasty, and ACI and reports the recent technical advances that have improved MRI of cartilage. Morphological evaluation methods are recommended for each of the respective techniques. Finally, an overview of T2 mapping and delayed gadolinium-enhanced MR imaging of cartilage in cartilage repair is provided.
Resumo:
Morphological and biochemical magnetic resonance imaging (MRI) is due to high field MR systems, advanced coil technology, and sophisticated sequence protocols capable of visualizing articular cartilage in vivo with high resolution in clinical applicable scan time. Several conventional two-dimensional (2D) and three-dimensional (3D) approaches show changes in cartilage structure. Furthermore newer isotropic 3D sequences show great promise in improving cartilage imaging and additionally in diagnosing surrounding pathologies within the knee joint. Functional MR approaches are additionally able to provide a specific measure of the composition of cartilage. Cartilage physiology and ultra-structure can be determined, changes in cartilage macromolecules can be detected, and cartilage repair tissue can thus be assessed and potentially differentiated. In cartilage defects and following nonsurgical and surgical cartilage repair, morphological MRI provides the basis for diagnosis and follow-up evaluation, whereas biochemical MRI provides a deeper insight into the composition of cartilage and cartilage repair tissue. A combination of both, together with clinical evaluation, may represent a desirable multimodal approach in the future, also available in routine clinical use.
Resumo:
PURPOSE: To use magnetization transfer (MT) imaging in the visualization of healthy articular cartilage and cartilage repair tissue after different cartilage repair procedures, and to assess global as well as zonal values and compare the results to T2-relaxation. MATERIALS AND METHODS: Thirty-four patients (17 after microfracture [MFX] and 17 after matrix-associated autologous cartilage transplantation [MACT]) were examined with 3T MRI. The MT ratio (MTR) was calculated from measurements with and without MT contrast. T2-values were evaluated using a multiecho, spin-echo approach. Global (full thickness of cartilage) and zonal (deep and superficial aspect) region-of-interest assessment of cartilage repair tissue and normal-appearing cartilage was performed. RESULTS: In patients after MFX and MACT, the global MTR of cartilage repair tissue was significantly lower compared to healthy cartilage. In contrast, using T2, cartilage repair tissue showed significantly lower T2 values only after MFX, whereas after MACT, global T2 values were comparable to healthy cartilage. For zonal evaluation, MTR and T2 showed a significant stratification within healthy cartilage, and T2 additionally within cartilage repair tissue after MACT. CONCLUSION: MT imaging is capable and sensitive in the detection of differences between healthy cartilage and areas of cartilage repair and might be an additional tool in biochemical cartilage imaging. For both MTR and T2 mapping, zonal assessment is desirable.