921 resultados para Tube-in-Tube-Reaktor


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Introduction: Prognostic factors are used in the Intensive Care Unit (ICU) to predict morbidity and mortality , especially in patients on mechanical ventilation (MV ) . Training protocols are used in MV patients with the aim of promoting the success of the weaning process. Objective: To assess which variables determine the outcome of patients undergoing mechanical ventilation and compare the effects of two protocols for weaning. Method: Patients under MV for more than 48 hours had collected the following information: sex, age , ideal weight, height , Acute Physiology and Chronic Health Evaluation (APACHE II), risk of mortality, Glasgow Coma Scale (GCS) and index Quick and perfunctory (IRRS) breathing. Patients with unsuccessful weaning performed one of weaning protocols: Progressive T - tube or tube - T + Threshold ® IMT. Patients were compared for outcome (death or non- death in the ICU ) and the protocols through the t test or Mann-Whitney test was considered significant when P <0.05. Results: Of 128 patients evaluated 56.25% were men, the mean age was 60.05 ± 17.85 years and 40.62 % patients died, and they had higher APACHE II scores, mortality risk, time VM and IRRS GCS and the lower value (p<0.05). The age, initial and final maximal inspiratory pressure, time of weaning and duration of MV was similar between protocols. Conclusion: The study suggests that the GCS, APACHE II risk of mortality, length of MV and IRRS variables determined the evolution of MV patients in this sample. Not found differences in the variables studied when comparing the two methods of weaning.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this paper we analyse the vacuum polarization effects due to a magnetic flux on massless fermionic fields in a cosmic string background. Three distinct configurations of magnetic fields are considered. In all of them the magnetic fluxes are confined in a long cylindrical tube of finite radius.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Aim To evaluate the inflammatory process induced by Biodentine and mineral trioxide aggregate (MTA) in rat subcutaneous tissues. Methodology A polyethylene tube filled with Biodentine (n = 20) or MTA (n = 20) was placed into the dorsal subcutaneous of forty male rats; in the control group (CG; n = 20), empty tubes were implanted. After 7, 15, 30 and 60 days, the polyethylene tubes surrounded by connective tissue were fixed and embedded in paraffin. The number of inflammatory cells was estimated in HE-stained sections; numerical density of interleukin-6 (IL-6)-immunolabelled cells was also performed. The differences amongst the groups were analysed statistically by Tukey's test (P ≤ 0.05). Results A high number of inflammatory cells and IL-6-positive cells were observed at 7 days, in all groups; however, in the Biodentine group, the number of inflammatory cells and IL-6-immunolabelled cells was significantly higher (P ≤ 0.05) in comparison with the other groups at 7 and 15 days. In the capsules of animals from all groups, a gradual and significant reduction (P ≤ 0.05) of these parameters was seen over time. At 60 days, the capsules exhibited numerous fibroblasts and bundles of collagen fibres; in addition, the number of IL-6-positive cells was not significantly different amongst Biodentine, MTA and control groups. Conclusions There was a significant regression in the inflammatory reaction in the capsules indicating, therefore, that Biodentine is a biocompatible material.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Myosins are molecular motors associated with the actin cytoskeleton that participate in the mechanisms of cellular motility. During the development of the nervous system, migration of nerve cells to specific sites, extension of growth cones, and axonal transport are dramatic manifestations of cellular motility. We demonstrate, via immunoblots, the expression of myosin Va during early stages of embryonic development in chicks, extending from the blastocyst period to the beginning of the fetal period. The expression of myosin Va in specific regions and cellular structures of the nervous system during these early stages was determined by immunocytochemistry using a polyclonal antibody. Whole mounts of chick embryos at 24-30-h stages showed intense immunoreactivity of the neural tube in formation along its full extent. Cross-sections at these stages of development showed strong labeling in neuroepithelial cells at the basal and apical regions of the neural tube wall. Embryos at more advanced periods of development (48h and 72 h) showed distinctive immunolabeling of neuroepithelial cells, neuroblasts and their cytoplasmic extensions in the mantle layer of the stratified neural tube wall, and neuroblasts and their cytoplasmic extensions in the internal wall of the optic cup, as well as a striking labeling of cells in the apparent nuclei of cranial nerves and budding fibers. These immunolocalization studies indicate temporal and site-specific expression of myosin Va during chick embryo development, suggesting that myosin Va expression is related to recruitment for specific cellular tasks.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This aim of the present study was to evaluate the pulp chamber penetration of 35% hydrogen peroxide activated by LED (light-emitting diode) or Nd:YAG laser in bovine teeth, after an in-office bleaching technique. Forty-eight bovine lateral incisors were divided into four groups, acetate buffer was placed into the pulp chamber and bleaching agent was applied as follows: for group A (n = 12), activation was performed by LED; for group B (n = 12), activation was performed by Nd:YAG laser (60 mJ, 20 Hz); group C (n = 12) received no light or laser activation; and the control group (n = 12) received no bleaching gel application or light or laser activation. The acetate buffer solution was transferred to a glass tube and Leuco Crystal Violet and horseradish peroxidase were added, producing a blue solution. The optical density of this solution was determined spectrophotometrically and converted into microgram equivalents of hydrogen peroxide. The results were analysed using ANOVA and Tukey's test (5%). It was verified that the effect of activation was significant, as groups activated by LED or laser presented greater hydrogen peroxide penetration into the pulp chamber (0.499 +/- 0.622 microg) compared with groups that were not (0.198 +/- 0.218 microg). There was no statistically significant difference in the penetration of hydrogen peroxide into the pulp chamber between the two types of activation (LED or laser). The results suggest that activation by laser or LED caused an increase in hydrogen peroxide penetration into the pulp chamber.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The objective of the present study was to optimize a radiographic technique for hand examinations using a computed radiography (CR) system and demonstrate the potential for dose reductions compared with clinically established technique. An exposure index was generated from the optimized technique to guide operators when imaging hands. Homogeneous and anthropomorphic phantoms that simulated a patient's hand were imaged using a CR system at various tube voltages and current settings (40-55 kVp, 1.25-2.8 mAs), including those used in clinical routines (50 kVp, 2.0 mAs) to obtain an optimized chart. The homogeneous phantom was used to assess objective parameters that are associated with image quality, including the signal difference-to-noise ratio (SdNR), which is used to define a figure of merit (FOM) in the optimization process. The anthropomorphic phantom was used to subjectively evaluate image quality using Visual Grading Analysis (VGA) that was performed by three experienced radiologists. The technique that had the best VGA score and highest FOM was considered the gold standard (GS) in the present study. Image quality, dose and the exposure index that are currently used in the clinical routine for hand examinations in our institution were compared with the GS technique. The effective dose reduction was 67.0%. Good image quality was obtained for both techniques, although the exposure indices were 1.60 and 2.39 for the GS and clinical routine, respectively.