964 resultados para Traffic flow parameter
Resumo:
Background: Cerebral autoregulation (CA) is a protective mechanism which maintains the steadiness of the cerebral blood flow (CBF) through a broad range of systemic blood pressure (BP). Acute hypertension has been shown to reduce the cerebrovascular adaptation to BP variations. However, it is still unknown whether CA is impaired in chronic hypertension. This study evaluated whether a strict control of BP affects the CA in patients with chronic hypertension, and compared a valsartan-based regimen to a regimen not inhibiting the renin-angiotensin-aldosterone system (non-RAAS). Methods: Eighty untreated patients with isolated systolic hypertension were randomized to valsartan 320 mg or to a non-RAAS regimen during 6 months. The medication was upgraded to obtain BP <140/90 mm Hg. Continuous recordings of arterial BP and CBF velocity (transcranial Doppler) were performed during periods of 5 minutes, at rest, and at different levels of alveolar CO(2) pressure provided by respiratory maneuvers. The dominant frequency of CBF oscillations was determined for each patient. Dynamic CA was measured as the mean phase shift between BP and CBF by cross-spectral analysis in the medium frequency and in the dominant CBF frequency. Results: Mean ambulatory 24-hour BP fell from 144/87 to 127/79 mm Hg in the valsartan group and from 144/87 to 134/81 mm Hg in the non-RAAS group (p = 0.13). Both groups had a similar reduction in the central BP and in the carotido-femoral pulse wave velocity. The average phase shift between BP fluctuations and CBF response at rest was normal at randomization (1.82 ± 0.08 s), which is considered a preserved autoregulation and increased to 1.91 ± 0.12 s at the end of study (p = 0.45). The comparison of both treatments showed no significant difference (-0.01 ± 0.17 s vs. 0.16 ± 0.16 s, p = 0.45) for valsartan versus non-RAAS groups. The plasmatic level of glycosylated hemoglobin decreased in the valsartan arm compared to the non-RAAS arm (-0.23 ± 0.06 vs. -0.08 ± 0.07%, p = 0.07). Conclusions: In elderly hypertensive men with isolated chronic systolic hypertension, CA seems efficient at baseline and is not significantly affected by 6 months of BP-lowering treatment. This suggests that the preventive effects of BP medication against stroke are not mediated through a restoration of the CA.
Resumo:
La peau est sujette à un vieillissement intrinsèque (processus naturel et chronologique) et extrinsèque (processus induit par l'environnement et notamment les rayons UV). Plusieurs études ont montré que le vieillissement cutané s'accompagne d'une réduction de la densité capillaire au sein du derme et d'une dégradation de plusieurs protéines de la matrice extracellulaire. Cette atteinte morphologique est associée à une diminution de la capacité vasodilatatrice maximale de la microcirculation dermique et en particulier, de la réponse maximale du flux sanguin cutané à un échauffement local de la surface cutanée à des températures avoisinant les 43-44°C. Cette réponse, appelée hyperémie locale induite par la chaleur (local thermal hyperemia), est facilement mesurable par des investigations non invasives, telles que le laser Doppler. Nous avons entrepris cette étude afin d'investiguer les effets de l'âge sur la réactivité de la microcirculation dermique dans des zones cutanées exposées différemment aux rayons UV. Pour ce faire, nous avons étudié, chez des patients jeunes (18 à 30 ans, n=13) et des patients âgés (> 60 ans, n=13), la vasodilatation cutanée induite par réchauffement local de la peau, au niveau de 3 sites anatomiques différents (la cuisse, l'avant- bras et le front). Les mesures ont été effectuées au moyen d'un laser Doppler. Pour chaque sujet et chaque site, la température cutanée fut tout d'abord amenée à 34°C par 2 corps de chauffe (A et B), disposés de manière adjacente sur la peau. La température fut ensuite augmentée à 39°C (corps de chauffe A) et à 41°C (corps de chauffe B) pour une durée de 30 minutes, dans l'optique d'induire une vasodilatation sous- maximale. Ensuite, la température fut augmentée à 43 °C (corps de chauffe A et B) pour 15 minutes supplémentaires. Enfin, la vasodilatation maximale a été induite par un échauffement local à 44°C pour 15 minutes supplémentaires (corps de chauffe A et B). L'enregistrement séquentiel du flux sanguin cutané, effectué chaque minute par laser Doppler imager, donne des images sur lesquelles peut être calculé le flux sanguin cutané (unités de perfusion, PU). Par la suite, nous avons calculé les conductances vasculaires cutanées (CVC), en divisant le flux sanguin (PU) par la tension artérielle moyenne (mmHg), afin de permettre une normalisation entre les différents sujets. Les CVC, évaluées au temps de départ (température 34°C) et après vasodilatation maximale (température 44°C), étaient plus hautes au niveau du front qu'au niveau des 2 autres sites anatomiques. Sur les 3 sites, la CVC maximale (température 44°C) diminuait avec l'âge mais de façon moins importante au niveau du front, en comparaison avec les 2 autres sites. La réponse aux températures sous-maximales (température 39 et 41°C), exprimée en pourcentage de la CVC maximale, ne variait pas avec l'âge ni en fonction du site anatomique étudié. En conclusion, cette étude est la première à étudier simultanément l'hyperémie locale induite par la chaleur sur 3 sites ayant une exposition différente aux rayons UV. Le processus utilisé (laser Doppler imager) est également unique dans la littérature concernant les altérations de la microcirculation cutanée en lien avec l'âge. Cette étude confirme ainsi que le vieillissement cutané intrinsèque et/ou extrinsèque réduit la capacité vasodilatatrice maximale de la microcirculation dermique. Par contre, la réactivité à réchauffement local à des températures moindres ne semble pas être affectée.
Resumo:
Giardia duodenalis (syn. lamblia; syn. intestinalis) susceptibility testing is not routinely performed because the classical culture methods are very time-consuming and laborious. We developed a novel flow cytometry (FC) assay to evaluate the susceptibility of G. duodenalis trophozoites to metronidazole (MTZ). Different concentrations of MTZ were added to cultures of trophozoites (10 5 /mL) and the cultures were incubated for different periods. The 50% inhibitory concentration was calculated and propidium iodide (PI) was used to quantify the number of dead cells. After treatment, PI-positive trophozoites increased with increasing drug concentration and exposure time. An excellent correlation was found between FC and the classical method. A novel, accurate and reliable method is now available to evaluate G. duodenalis viability.
Resumo:
PROPÒSIT: Estudiar l'efecte de la cirurgia LASIK en la llum dispersa i la sensibilitat al contrast. MÈTODES: Vint-i-vuit pacients van ser tractats amb LASIK. La qualitat visual es va avaluar abans de l'operació i dos mesos després. RESULTATS: La mitjana de llum dispersa i la sensibilitat al contrast abans de l'operació no va canviar en dos mesos després. Només un ull tenia un marcat augment en la llum dispersa. Nou ulls van presentar una lleugera disminució en la sensibilitat al contrast. S'han trobat dues complicacions. CONCLUSIÓ: Després de LASIK la majoria dels pacients (80%) no van tenir complicacions i van mantenir la seva qualitat visual. Uns pocs pacients (16%) van tenir una mica de qualitat visual disminuïda. Molt pocs (4%) van tenir complicacions clíniques amb disminució en la qualitat visual.
Resumo:
In previous work we proposed a multi-objective traffic engineering scheme (MHDB-S model) using different distribution trees to multicast several flows. In this paper, we propose a heuristic algorithm to create multiple point-to-multipoint (p2mp) LSPs based on the optimum sub-flow values obtained with our MHDB-S model. Moreover, a general problem for supporting multicasting in MPLS networks is the lack of labels. To reduce the number of labels used, a label space reduction algorithm solution is also considered
Resumo:
In this paper, we perform a societal and economic risk assessment for debris flows at the regional scale, for lower Valtellina, Northern Italy. We apply a simple empirical debris-flow model, FLOW-R, which couples a probabilistic flow routing algorithm with an energy line approach, providing the relative probability of transit, and the maximum kinetic energy, for each cell. By assessing a vulnerability to people and to other exposed elements (buildings, public facilities, crops, woods, communication lines), and their economic value, we calculated the expected annual losses both in terms of lives (societal risk) and goods (direct economic risk). For societal risk assessment, we distinguish for the day and night scenarios. The distribution of people at different moments of the day was considered, accounting for the occupational and recreational activities, to provide a more realistic assessment of risk. Market studies were performed in order to assess a realistic economic value to goods, structures, and lifelines. As terrain unit, a 20 m x 20 m cell was used, in accordance with data availability and the spatial resolution requested for a risk assessment at this scale. Societal risk the whole area amounts to 1.98 and 4.22 deaths/year for the day and the night scenarios, respectively, with a maximum of 0.013 deaths/year/cell. Economic risk for goods amounts to 1,760,291 ?/year, with a maximum of 13,814 ?/year/cell.
Resumo:
Rb-82cardiac PET has been used to non-invasively assess myocardial blood flow (MBF)and myocardial flow reserve (MFR). The impact of MBF and MFR for predictingmajor adverse cardiovascular events (MACE) has not been investigated in aprospective study, which was our aim. MATERIAL AND METHODS: In total, 280patients (65±10y, 36% women) with known or suspected CAD were prospectivelyenrolled. They all underwent both a rest and adenosine stress Rb-82 cardiacPET/CT. Dynamic acquisitions were processed with the FlowQuant 2.1.3 softwareand analyzed semi-quantitatively (SSS, SDS) and quantitatively (MBF, MFR) andreported using the 17-segment AHA model. Patients were stratified based on SDS,stress MBF and MFR and allocated into tertiles. For each group, annualizedevent rates were computed by dividing the number of annualized MACE (cardiacdeath, myocardial infarction, revascularisation or hospitalisation forcardiac-related event) by the sum of individual follow-up periods in years.Outcome were analysed for each group using Kaplan-Meier event-free survivalcurves and compared using the log-rank test. Multivariate analysis wasperformed in a stepwise fashion using Cox proportional hazards regressionmodels (p<0.05 for model inclusion). RESULTS: In a median follow-up of 256days (range 168-440d), 44 MACE were observed. Ischemia (SDS≥2) was observed in95 patients who had higher annualized MACE rate as compared to those without(55% vs. 9.8%, p<0.0001). The group with the lowest MFR tertile (MFR<1.76)had higher MACE rate than the two highest tertiles (51% vs. 9% and 14%,p<0.0001). Similarly, the group with the lowest stress MBF tertile(MBF<1.78mL/min/g) had the highest annualized MACE rate (41% vs. 26% and 6%,p=0.0002). On multivariate analysis, the addition of MFR or stress MBF to SDSsignificantly increased the global χ2 (from 56 to 60, p=0.04; and from56 to 63, p=0.01). The best prognostic power was obtained in a model combiningSDS (p<0.001) and stress MBF (p=0.01). Interestingly, the integration ofstress MBF enhanced risk stratification even in absence of ischemia.CONCLUSIONS: Quantification of MBF or MFR in Rb-82 cardiac PET/CT providesindependent and incremental prognostic information over semi-quantitativeassessment with SDS and is of value for risk stratification.
Resumo:
Exposure to fine particles and noise has been linked to cardiovascular diseases and elevated cardiovascular mortality affecting the worldwide population. Residence and/or work in proximity to emission sources as for example road traffic leads to an elevated exposure and a higher risk for adverse health effects. Highway maintenance workers spend most of their work time in traffic and are exposed regularly to particles and noise. The aims of this thesis were to provide a better understanding of the workers' mixed exposure to particles and noise and to assess cardiopulmonary short term health effects in relation to this exposure. Exposure and health data were collected in collaboration with 8 maintenance centers of the Swiss Road Maintenance Services located in the cantons Bern, Fribourg and Vaud in western Switzerland. Repeated measurements with 18 subjects were conducted during 50 non-consecutive work shifts between Mai 2010 and February 2012, equally distributed over all seasons. In the first part of this thesis we tested and validated measurements of ultrafine particles with a miniature diffusion size classifier (miniDiSC) - a novel particle counting device that was used for the exposure assessment during highway maintenance work. We found that particle numbers and average particle size measured by the miniDiSC were highly correlated with data from the P-TRAK, a condensation particle counter (CPC), as well as from a scanning mobility particle sizer (SMPS). However, the miniDiSC measured significantly more particles than the P-TRAK and significantly less than the SMPS in its full size range. Our data suggests that the instrument specific cutoffs were the main reason for the different particle counts. The first main objective of this thesis was to investigate the exposure of highway maintenance workers to air pollutants and noise, in relation to the different maintenance activities. We have seen that the workers are regularly exposed to high particle and noise levels. This was a consequence of close proximity to highway traffic and the use of motorized working equipment such as brush cutters, chain saws, generators and pneumatic hammers during which the highest exposure levels occurred. Although exposure to air pollutants were not critical if compared to occupational exposure limits, the elevated exposure to particles and noise may lead to a higher risk for cardiovascular diseases in this worker population. The second main objective was to investigate cardiopulmonary short-term health effects in relation to the particle and noise exposure during highway maintenance work. We observed a PM2.5 related increase of the acute-phase inflammation markers C-reactive protein and serum amyloid A and a decrease of TNFa. Heart rate variability increased as a consequence of particle as well as noise exposure. Increased high frequency power indicated a stronger parasympathetic influence on the heart. Elevated noise levels during recreational time, after work, were related to increased blood pressure. Our data confirmed that highway maintenance workers are exposed to elevated levels of particles and noise as compared to the average population. This exposure poses a cardiovascular health risk and it is therefore important to make efforts to better protect the workers health. The use of cleaner machines during maintenance work would be a major step to improve the workers' situation. Furthermore, regulatory policies with the aim of reducing combustion and non-combustion emissions from road traffic are important for the protection of workers in traffic environments and the entire population.
Resumo:
A first assessment of debris flow susceptibility at a large scale was performed along the National Road N7, Argentina. Numerous catchments are prone to debris flows and likely to endanger the road-users. A 1:50,000 susceptibility map was created. The use of a DEM (grid 30 m) associated to three complementary criteria (slope, contributing area, curvature) allowed the identification of potential source areas. The debris flow spreading was estimated using a process- and GISbased model (Flow-R) based on basic probabilistic and energy calculations. The best-fit values for the coefficient of friction and the mass-to-drag ratio of the PCM model were found to be ? = 0.02 and M/D = 180 and the resulting propagation on one of the calibration site was validated using the Coulomb friction model. The results are realistic and will be useful to determine which areas need to be prioritized for detailed studies.
Resumo:
Like numerous torrents in mountainous regions, the Illgraben creek (canton of Wallis, SW Switzerland) produces almost every year several debris flows. The total area of the active catchment is only 4.7 km², but large events ranging from 50'000 to 400'000 m³ are common (Zimmermann 2000). Consequently, the pathway of the main channel often changes suddenly. One single event can for instance fill the whole river bed and dig new several-meters-deep channels somewhere else (Bardou et al. 2003). The quantification of both, the rhythm and the magnitude of these changes, is very important to assess the variability of the bed's cross section and long profile. These parameters are indispensable for numerical modelling, as they should be considered as initial conditions. To monitor the channel evolution an Optech ILRIS 3D terrestrial laser scanner (LIDAR) was used. LIDAR permits to make a complete high precision 3D model of the channel and its surroundings by scanning it from different view points. The 3D data are treated and interpreted with the software Polyworks from Innovmetric Software Inc. Sequential 3D models allow for the determination of the variation in the bed's cross section and long profile. These data will afterwards be used to quantify the erosion and the deposition in the torrent reaches. To complete the chronological evolution of the landforms, precise digital terrain models, obtained by high resolution photogrammetry based on old aerial photographs, will be used. A 500 m long section of the Illgraben channel was scanned on 18th of August 2005 and on 7th of April 2006. These two data sets permit identifying the changes of the channel that occurred during the winter season. An upcoming scanning campaign in September 2006 will allow for the determination of the changes during this summer. Preliminary results show huge variations in the pathway of the Illgraben channel, as well as important vertical and lateral erosion of the river bed. Here we present the results of a river bank on the left (north-western) flank of the channel (Figure 1). For the August 2005 model the scans from 3 viewpoints were superposed, whereas the April 2006 3D image was obtained by combining 5 separate scans. The bank was eroded. The bank got eroded essentially on its left part (up to 6.3 m), where it is hit by the river and the debris flows (Figures 2 and 3). A debris cone has also formed (Figure 3), which suggests that a part of the bank erosion is due to shallow landslides. They probably occur when the river erosion creates an undercut slope. These geometrical data allow for the monitoring of the alluvial dynamics (i.e. aggradation and degradation) on different time scales and the influence of debris flows occurrence on these changes. Finally, the resistance against erosion of the bed's cross section and long profile will be analysed to assess the variability of these two key parameters. This information may then be used in debris flow simulation.
Resumo:
Perfusion CT studies of regional cerebral blood flow (rCBF), involving sequential acquisition of cerebral CT sections during IV contrast material administration, have classically been reported to be achieved at 120 kVp. We hypothesized that using 80 kVp should result in the same image quality while significantly lowering the patient's radiation dose, and we evaluated this assumption. In five patients undergoing cerebral CT survey, one section level was imaged at 120 kVp and 80 kVp, before and after IV administration of iodinated contrast material. These four cerebral CT sections obtained in each patient were analyzed with special interest to contrast, noise, and radiation dose. Contrast enhancement at 80 kVp is significantly increased (P < .001), as well as contrast between gray matter and white matter after contrast enhancement (P < .001). Mean noise at 80 kVp is not statistically different (P = .042). Finally, performance of perfusion CT studies at 80 kVp, keeping mAs constant, lowers the radiation dose by a factor of 2.8. We, thus, conclude that 80 kVp acquisition of perfusion CT studies of rCBF will result in increased contrast enhancement and should improve rCBF analysis, with a reduced patient's irradiation.
Resumo:
PURPOSE: To determine the relationship between carotid intima-media thickness (IMT), coronary artery calcification (CAC), and myocardial blood flow (MBF) at rest and during vasomotor stress in type 2 diabetes mellitus (DM). METHODS: In 68 individuals, carotid IMT was measured using high-resolution vascular ultrasound, while the presence of CAC was determined with electron beam tomography (EBT). Global and regional MBF was determined in milliliters per gram per minute with (13)N-ammonia and positron emission tomography (PET) at rest, during cold pressor testing (CPT), and during adenosine (ADO) stimulation. RESULTS: There was neither a relationship between carotid IMT and CAC (r = 0.10, p = 0.32) nor between carotid IMT and coronary circulatory function in response to CPT and during ADO (r = -0.18, p = 0.25 and r = 0.10, p = 0.54, respectively). In 33 individuals, EBT detected CAC with a mean Agatston-derived calcium score of 44 +/- 18. There was a significant difference in regional MBFs between territories with and without CAC at rest and during ADO-stimulated hyperemia (0.69 +/- 0.24 vs. 0.74 +/- 0.23 and 1.82 +/- 0.50 vs. 1.95 +/- 0.51 ml/g/min; p < or = 0.05, respectively) and also during CPT in DM but less pronounced (0.81 +/- 0.24 vs. 0.83 +/- 0.23 ml/g/min; p = ns). The increase in CAC was paralleled with a progressive regional decrease in resting as well as in CPT- and ADO-related MBFs (r = -0.36, p < or = 0.014; r = -0.46, p < or = 0.007; and r = -0.33, p < or = 0.041, respectively). CONCLUSIONS: The absence of any correlation between carotid IMT and coronary circulatory function in type 2 DM suggests different features and stages of early atherosclerosis in the peripheral and coronary circulation. PET-measured MBF heterogeneity at rest and during vasomotor stress may reflect downstream fluid dynamic effects of coronary artery disease (CAD)-related early structural alterations of the arterial wall.
Resumo:
This paper deals with fault detection and isolation problems for nonlinear dynamic systems. Both problems are stated as constraint satisfaction problems (CSP) and solved using consistency techniques. The main contribution is the isolation method based on consistency techniques and uncertainty space refining of interval parameters. The major advantage of this method is that the isolation speed is fast even taking into account uncertainty in parameters, measurements, and model errors. Interval calculations bring independence from the assumption of monotony considered by several approaches for fault isolation which are based on observers. An application to a well known alcoholic fermentation process model is presented
Resumo:
In the context of Systems Biology, computer simulations of gene regulatory networks provide a powerful tool to validate hypotheses and to explore possible system behaviors. Nevertheless, modeling a system poses some challenges of its own: especially the step of model calibration is often difficult due to insufficient data. For example when considering developmental systems, mostly qualitative data describing the developmental trajectory is available while common calibration techniques rely on high-resolution quantitative data. Focusing on the calibration of differential equation models for developmental systems, this study investigates different approaches to utilize the available data to overcome these difficulties. More specifically, the fact that developmental processes are hierarchically organized is exploited to increase convergence rates of the calibration process as well as to save computation time. Using a gene regulatory network model for stem cell homeostasis in Arabidopsis thaliana the performance of the different investigated approaches is evaluated, documenting considerable gains provided by the proposed hierarchical approach.