964 resultados para Time Factors


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: This study investigated the effect of experimental photopolymerized coatings, containing zwitterionic or hydrophilic monomers, on the hydrophobicity of a denture base acrylic resin and on Candida albicans adhesion. Methods: Acrylic specimens were prepared with rough and smooth surfaces and were either left untreated (control) or coated with one of the following experimental coatings: 2-hydroxyethyl methacrylate (HE); 3-hydroxypropyl methacrylate (HP); and 2-trimethylammonium ethyl methacrylate chloride (T); and sulfobetaine methacrylate (S). The concentrations of these constituent monomers were 25%, 30% or 35%. Half of the specimens in each group (control and experimentals) were coated with saliva and the other half remained uncoated. The surface free energy of all specimens was measured, regardless of the experimental condition. C. albicans adhesion was evaluated for all specimens, both saliva conditioned and unconditioned. The adhesion test was performed by incubating specimens in C. albicans suspensions (1 × 10 7 cell/mL) at 37 °C for 90 min. The number of adhered yeasts were evaluated by XTT (2,3-bis[2-methoxy-4-nitro-5-sulfophenyl]-5-[{phenylamino} carbonyl]-2H-tetrazolium-hydroxide) method. Results: For rough surfaces, coatings S (30 or 35%) and HP (30%) resulted in lower absorbance values compared to control. These coatings exhibited more hydrophilic surfaces than the control group. Roughness increased the adhesion only in the control group, and saliva did not influence the adhesion. The photoelectron spectroscopy analysis (XPS) confirmed the chemical changes of the experimental specimens, particularly for HP and S coatings. Conclusions: S and HP coatings reduced significantly the adhesion of C. albicans to the acrylic resin and could be considered as a potential preventive treatment for denture stomatitis. © 2012 Elsevier Ltd.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aims The macrophage migration inhibitory factor (MIF) is an intracellular inhibitor of the central nervous system actions of angiotensin II on blood pressure. Considering that angiotensin II actions at the nucleus of the solitary tract are important for the maintenance of hypertension in spontaneously hypertensive rats (SHRs), we tested if increased MIF expression in the nucleus of the solitary tract of SHR alters the baseline high blood pressure in these rats.Methods and resultsEight-week-old SHRs or normotensive rats were microinjected with the vector AAV2-CBA-MIF into the nucleus of the solitary tract, resulting in MIF expression predominantly in neurons. Rats also underwent recordings of the mean arterial blood pressure (MAP) and heart rate (via telemetry devices implanted in the abdominal aorta), cardiac- and baroreflex function. Injections of AAV2-CBA-MIF into the nucleus of the solitary tract of SHRs produced significant decreases in the MAP, ranging from 10 to 20 mmHg, compared with age-matched SHRs that had received identical microinjections of the control vector AAV2-CBA-eGFP. This lowered MAP in SHRs was maintained through the end of the experiment at 31 days, and was associated with an improvement in baroreflex function to values observed in normotensive rats. In contrast to SHRs, similar increased MIF expression in the nucleus of the solitary tract of normotensive rats produced no changes in baseline MAP and baroreflex function.ConclusionThese results indicate that an increased expression of MIF within the nucleus of the solitary tract neurons of SHRs lowers blood pressure and restores baroreflex function. © 2012 Published on behalf of the European Society of Cardiology. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to investigate the effect of fatigue induced by an exhaustive laboratory-based soccer-specific exercise on different hamstrings/quadriceps (H:Q) ratios of soccer players. Twenty-two male professional soccer players (23·1 ± 3·4 year) performed maximal eccentric (ecc) and concentric (con) contractions for knee extensors (KE) and flexors (KF) at 60° s-1 and 180° s-1 to assess conventional (Hcon:Qcon) and functional (Hecc:Qcon) ratios. Additionally, they performed maximal voluntary isometric contraction for KE and KF, from which the maximal muscle strength, rate of force development (RFD) and RFD H:Q strength ratio (RFDH:Q) were extracted. Thereafter, subjects were performed an exhaustive laboratory-based soccer-specific exercise and a posttest similar to the pretest. There was significant reduction in Hcon:Qcon (0·60 ± 0·06 versus 0·58 ± 0·06, P<0·05) and in Hecc:Qcon (1·29 ± 0·2 versus 1·16 ± 0·2, P<0·01) after the soccer-specific exercise. However, no significant difference between Pre and Post exercise conditions was found for RFDH:Q at 0-50 (0·53 ± 0·23 versus 0·57 ± 0·24, P>0·05) and 0-100 ms (0·53 ± 0·17 versus 0·55 ± 0·17, P>0·05). In conclusion, H:Q strength ratios based on peak force values are more affected by fatigue than RFDH:Q obtained during early contraction phase. Thus, fatigue induced by soccer-specific intermittent protocol seems not reduce the potential for knee joint stabilization during the initial phase of voluntary muscle contraction. copy; 2012 Scandinavian Society of Clinical Physiology and Nuclear Medicine.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study determined if dentin proteases are denatured by phosphoric acid (PA) used in etch-and-rinse dentin adhesives. Dentin beams were completely demineralized with EDTA for 30 days. We acid-etched experimental groups by exposing the demineralized dentin beams to 1, 10, or 37 mass% PA for 15 sec or 15 min. Control beams were not exposed to PA but were incubated in simulated body fluid for 3 days to assay their total endogenous telopeptidase activity, by their ability to solubilize C-terminal crosslinked telopeptides ICTP and CTX from insoluble dentin collagen. Control beams released 6.1 ± 0.8 ng ICTP and 0.6 ± 0.1 ng CTX/mg dry-wt/3 days. Positive control beams pre-incubated in p-aminophenylmercuric acetate, a compound known to activate proMMPs, released about the same amount of ICTP peptides, but released significantly less CTX. Beams immersed in 1, 10, or 37 mass% PA for 15 sec or 15 min released amounts of ICTP and CTX similar to that released by the controls (p > 0.05). Beams incubated in galardin, an MMP inhibitor, or E-64, a cathepsin inhibitor, blocked most of the release of ICTP and CTX, respectively. It is concluded that PA does not denature endogenous MMP and cathepsin activities of dentin matrices. © 2013 International & American Associations for Dental Research.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fluoride levels in the public water supplies of 40 Brazilian cities were analyzed and classified on the basis of risk/benefit balance. Samples were collected monthly over a seven-year period from three sites for each water supply source. The samples were analyzed in duplicate in the laboratory of the Center for Research in Public Health - UNESP using an ion analyzer coupled to a fluoride-specific electrode. A total of 19,533 samples were analyzed, of which 18,847 were artificially fluoridated and 686 were not artificially fluoridated. In samples from cities performing water fluoridation, 51.57% (n=9,720) had fluoride levels in the range of 0.55 to 0.84 mg F/L; 30.53% (n=5,754) were below 0.55 mg F/L and 17.90% (n=3,373) were above 0.84 mg F/L (maximum concentration=6.96 mg F/L). Most of the cities performing fluoridation that had a majority of samples with fluoride levels above the recommended parameter had deep wells and more than one source of water supply. There was some variability in the fluoride levels of samples from the same site and between collection sites in the same city. The majority of samples from cities performing fluoridation had fluoride levels within the range that provides the best combination of risks and benefits, minimizing the risk of dental fluorosis while preventing dental caries. The conduction of studies about water distribution systems is suggested in cities with high natural fluoride concentrations in order to optimize the use of natural fluoride for fluoridation costs and avoid the risk of dental fluorosis.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The posterior position in the arches is one of the factors that underlies the poor prognosis of molar teeth (M). It is speculated that M do not benefit from the oral hygiene routine as well as non-molars (NM) do. This study evaluated the response of M and NM to supragingival control during a 6-month period in 25 smokers (S) and 25 never-smokers (NS) with moderate-to-severe periodontitis. One calibrated examiner assessed visible plaque (VPI) and gingival bleeding (GBI) indexes, periodontal probing depth (PPD), bleeding on probing (BOP), and clinical attachment loss (CAL) at days 0 (baseline), 30 and 180. At baseline, M showed significantly higher mean values of VPI (p = 0.017) and PPD (p < 0.001) compared with NM; CAL was also greater in M (p < 0.001) and was affected by smoking (p = 0.007). The reductions obtained for periodontal indicators at day 180 showed similar responses between M and NM. For CAL, M (NS 0.57 ± 0.50; S 0.67 ± 0.64) and NM (NS 0.38 ± 0.23; S 0.50 ± 0.33) reached an almost significant difference (p = 0.05). Smoking did not influence the response to treatment. Multilevel analysis revealed that, only for PDD reductions, the interaction between sites, teeth and patient was significant (p < 0.001). It was concluded that M benefit from an adequate regimen of supragingival biofilm control; therefore, supragingival condition should be considered in the prognosis of molar teeth.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

People increasingly desire tooth whitening. Considering the wide range of whitening products on the market, this study evaluated the efficacy of whitening toothpastes and mouth rinses compared with the 10% carbamide peroxide (CP) whitening gel. We obtained 120 cylindrical specimens from bovine teeth, which were darkened for 24 hours in a coffee solution. The color measurement was performed by a spectrophotometer using the CIE L*a*b* system, and specimens were divided into six groups according to the use of the following agents: group 1, conventional fluoridated toothpaste; group 2, Close Up White Now; group 3, Listerine Whitening; group 4, Colgate Plax Whitening; group 5, experimental mouth rinse with Plasdone; and group 6, 10% CP Whiteness Perfect. After the simulation of 12 weeks of treatment for groups 1 to 5 and 14 days of treatment for group 6, the specimens were subjected to a new color reading. Data were subjected to one-way analysis of variance (α=0.05), which showed significant differences among groups after 12 weeks for ΔE (p=0.001). Results of the Tukey test revealed that groups 3, 4, and 6 presented significantly higher color alteration than groups 1, 2, and 5. The whitening toothpaste Close Up White Now and the experimental mouth rinse with Plasdone showed similar color alteration as conventional toothpaste after a 12-week treatment simulation. These groups presented significantly lower color alteration compared with whitening mouth rinses Listerine and Colgate Plax Whitening, which showed similar results to those observed after 14 days of bleaching with 10% CP treatment.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aim: This study evaluates bond strength between dentin and composite using adhesives with different solvents to dry and wet dentin. Materials and methods: Ninety bovine incisors were used; the vestibular surfaces were worn by the exposure of an area with a diameter of 4 mm of dentin. The specimens were divided into 6 groups, according to the type of adhesive used and hydratation stals: Group SB-wet: Single Bond 2 in wet dentin, Group SBdry: Single Bond 2 in dry dentin, Group SL-wet: Solobond M in wet dentin, Group SL-dry: Solobond M in dentin dry. Group XPwet: XP Bond in wet dentin, Group XP-dry: XP Bond in dentin dry. They were cut to obtain specimens in the shape of stick with 1 × 1 mm and subjected to microtensile test in universal testing machine with a cross speed of 1mm/min. The data were analyzed with ANOVA and Tukey's tests (5%). Results: ANOVA showed significant differences for surface treatment and interaction, but no difference was found for adhesive factor. The Tukey's test showed that the samples with wet dentin shown higher values of bond strength. Conclusion: The adhesive did not influence in the bond strength. The groups with wet dentin showed higher values of bond strength than groups with dry dentin.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aim: The aim of this study was to compare the microtensile bond strength of three adhesive systems, using different methods of dentin preparation. Materials and methods: A hundred and eight bovine teeth were used. The dentin from buccal face was exposed and prepared with three different methods, divided in 3 groups: Group 1 (DT)- diamond tip on a high-speed handpiece; Group 2 (CVD)-CVD tip on a ultrasonic handpiece; Group 3 (LA)-Er: YAG laser. The teeth were divided into 3 subgroups, according adhesive systems used: Subgroup 1-Adper Single Bond Plus/3M ESPE (SB) total-etch adhesive; Subgroup 2-Adper Scotchbond SE/3M ESPE (AS) selfetching adhesive; Subgroup 3-Clearfil SE Bond/Kuraray (CS) selfetching adhesive. Blocks of composite (Filtek Z250-3M ESPE) 4 mm high were built up and specimens were stored in deionized water for 24 hours at 37°C. Serial mesiodistal and buccolingual cuts were made and stick-like specimens were obtained, with transversal section of 1.0 mm2. The samples were submitted to microtensile test at 1 mm/min and load of 10 kg in a universal testing machine. Data (MPa) were subjected to ANOVA and Tukey's tests (p < 0.05). Results and conclusion: Surface treatment with Diamond or CVD tips associated with Clearfil SE Bond adhesive produced significantly lower bond strength values compared to other groups. Surface treatment with Er: YAG laser associated with Single Bond Plus or Clearfil SE Bond adhesives and surface treatment with CVD tip associated with Adper Scotchbond SE adhesive produced significantly lower bond strength values compared to surface treatment with diamond or CVD tips associated with Single Bond Plus or Adper Scotchbond SE adhesives. Clinical significance: Interactions between laser and the CVD tip technologies and the different adhesive systems can produce a satisfactory bonding strength result, so that these associations may be beneficial and enhance the clinical outcomes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aims and objectives: The behavior of polymer-matrix composite is dependent on the degree of conversion. The aim of this study was to evaluate the degree of conversion of two resin cements following storage at 37°C immediately, 24 and 48 hours, and 7 days after light-curing by FTIR analysis. Materials and methods: The specimens were made in a metallic mold and cured with blue LED with power density of 500 mW/cm2 for 30 seconds. The specimens were pulverized, pressed with KBr and analyzed with FTIR following storage times. Statistical analysis used: ANOVA (two-way) and Tukey's post hoc. Results: To the polymer-matrix composites between 24 and 48 hours does not show a significant increase (p > 0.05), however, the highest values were found after 7 days. Conclusion: The polymer-matrix composites used in this study showed similarity on the degree of conversion and increased of according to the time of storage.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Two series of new chitosan derivatives were synthesized by reaction of deacetylated chitosan (CH) with propyl (CH-Propyl) and pentyl (CH-Pentyl) trimethylammonium bromides to obtain derivatives with increasing degrees of substitution (DS). The derivatives were characterized by 1H NMR and potentiometric titration techniques and their antifungal activities on the mycelial growth of Aspergillus flavus were investigated in vitro. The antifungal activities increase with DS and the more substituted derivatives of both series, CH-Propyl and CH-Pentyl, exhibited antifungal activities respectively three and six times higher than those obtained with commercial and deacetylated chitosan. The minimum inhibitory concentrations (MIC) were evaluated at 24, 48 and 72h by varying the polymer concentration from 0.5 to 16g/L and the results showed that the quaternary derivatives inhibited the fungus growth at polymer concentrations four times lower than that obtained with deacetylated chitosan (CH). The chitosans modified with pentyltrimethylammonium bromide exhibited higher activity and results are discussed taking into account the degree of substitution (DS). © 2012 Elsevier GmbH.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Osteonecrosis of the jaw (ONJ) following the use of bisphosphonates has become of increased interest in the scientific community, due in particular to its as-yet-unsolved pathogenesis. An experimental model of ONJ was induced in normal male rats [alendronate (ALN); 1 mg/Kg/day; n = 10] and matched controls (saline solution; n = 10). After 60 days of drug treatment, all animals were subjected to extractions of the left first lower molars and were euthanized at 3 and 28 days postsurgery. The following analyses were performed: (i) descriptive and quantitative (scores) histological evaluation, (ii) stereometry of distal sockets and (iii) biochemical measurement of C-telopeptide cross-linked collagen type I (CTX) and bone-specific alkaline phosphatase (BALP). The results showed that 28 days postsurgery the animals treated with ALN had areas of exposed and necrotic bone, associated with significant infection, especially in the interalveolar septum area and crestal regions, compared with controls. The levels of CTX, BALP and bone volume, as well as the degrees of inflammation and vascularization, were significantly reduced in these animals. Therefore, analysis of the data presented suggests that ALN therapy is associated with the development of osteonecrosis in the jaws of rodents after tooth extraction. © 2012 International Journal of Experimental Pathology.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background:  Few studies have investigated potential differences between the opinions of educators and undergraduates regarding spirituality in patient care. Understanding these differences, could lead to better strategies for educational proposes. Purpose:  To compare the opinions of medical teachers (MTs) and medical students (MSs) regarding spirituality training in a Brazilian medical school. Methods:  A cross-sectional study was conducted. MTs and MSs filled out a questionnaire containing the Duke Religion Index, and questions regarding spirituality in clinical practice and at medical school. A comparison between early-curriculum MSs, late curriculum MSs and MTs was carried out. Chi-square (categorical) and Mann-Whitney (continuous/ordinal) tests were used. Results:  A total of 475 MSs and 44 MTs were evaluated. Results showed that MSs did not address spirituality as frequently as MTs (p<0.001), and that most participants did not feel prepared to address this issue, and believe that Brazilian medical schools are not giving all the required information in this field. Nevertheless, they believe MSs should be prepared to discuss these issues. Late-curriculum MSs believed that spirituality plays a more positive role in patient health (p=0.027), and were more prone to address this issue than early-curriculum MSs (p=0.023). Conclusion:  These findings revealed some of the challenges faced by spirituality medical training in Brazil, and differences between MTs and MSs regarding this issue. Further studies are needed to replicate these findings in other countries. © Blackwell Publishing Ltd 2013.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To comparatively and prospectively compare in a randomized clinical trial, dentin hypersensitivity after treatment with three in-office bleaching systems, based on hydrogen peroxide at different concentrations, with and without light source activation. Methods: 88 individuals were included according to inclusion and exclusion criteria. Subjects were randomly divided into the following three treatment groups: Group 1 was treated with three 15-minute applications of hydrogen peroxide at 15% with titanium dioxide (Lase Peroxide Lite) that was light-activated (Light Plus Whitening Lase) with five cycles of 1 minute and 30 seconds each cycle, giving a total treatment time of 45 minutes; Group 2 was treated with three 10-minute applications of hydrogen peroxide at 35% (Lase Peroxide Sensy), activated by light (LPWL) same activation cycles than Group 1, with a total treatment time of 30 minutes; Group 3 was treated with only one application for 45 minutes of hydrogen peroxide at 35% (Whitegold Office) without light activation. Each subject underwent one session of bleaching on the anterior teeth according to the manufacturers' instructions. Dentin sensitivity was recorded with a visual analogue scale (VAS) at baseline, immediately after, and at 7 and 30 days after treatment using a stimulus of an evaporative blowing triple syringe for 3 seconds on the upper central incisors from a distance of 1 cm. A Kruskal-Wallis test followed by Mann-Whitney test was performed for statistical analysis. Results: All groups showed increased sensitivity immediately after treatment. Group 1 displayed less changes relative to baseline with no significant differences (P= 0.104). At 7 and 30 days after treatment, a comparison of VAS values indicated no significant differences between all groups (P= 0.598 and 0.489, respectively).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The rat exposure test (RET) is a prey (mouse)-predator (rat) situation that activates brain defensive areas and elicits hormonal and defensive behavior in the mouse. Here, we investigated possible correlations between the spatiotemporal [time spent in protected (home chamber and tunnel) and unprotected (surface) compartments and frequency of entries into the three compartments] and ethological [e.g., duration of protected and unprotected stretched-attend postures (SAP), duration of contact with the rat's compartment] measures (Experiment 1). Secondly, we investigated the effects of systemic treatment with pro- or anti-aversive drugs on the behavior that emerged from the factor analysis (Experiment 2). The effects of chronic (21 days) imipramine and fluoxetine on defensive behavior were also investigated (Experiment 3). Exp. 1 revealed that the time in the protected compartment, protected SAP and rat contacts loaded on factor 1 (defensive behavior), while the total entries and unprotected SAP loaded on factor 2 (locomotor activity). Exp. 2 showed that alprazolam (but not diazepam) selectively changed the defensive factor. Caffeine produced a mild proaversive-like effect, whereas yohimbine only decreased locomotor activity (total entries). Fluoxetine (but not imipramine) produced a weak proaversive-like effect. 5-HT1A/5-HT2 receptor ligands did not change any behavioral measure. In Exp. 3, chronic fluoxetine (but not imipramine) attenuated the defensive behavior factor without changing locomotion. Given that the defensive factor was sensitive to drugs known to attenuate (alprazolam and chronic fluoxetine) and induce (caffeine) panic attack, we suggest the RET as a useful test to assess the effects of panicolytic and panicogenic drugs. © 2012 Elsevier B.V.