984 resultados para Tibial arteries
Resumo:
BACKGROUND: Only about half the patients with xanthelasma are hyperlipidemic. The clinical significance of xanthelasma as a marker of cardiovascular disease is not yet well defined. OBJECTIVE: To determine the risk of cardiovascular disease in patients with normolipidemic and hyperlipidemic xanthelasma. METHODS: Carotid ultrasonography (7 MHz using B-mode images, Advanced Technology Laboratories) was used to detect carotid plaques and measure the intima-media thickness (IMT) of the common carotid arteries. Seventeen patients with normolipidemic and hyperlipidemic xanthelasma were examined and compared with 21 age-matched normal subjects. RESULTS: The risk of cardiovascular disease was significantly increased in patients with xanthelasma. Carotid plaques were more frequent in patients with xanthelasma than in controls (64.7% and 23.8%, respectively; P = 0.020), and IMT was significantly higher (mean +/- SD: 1.1 +/- 0.1 and 0.6 +/- 0.2 mm, respectively; P < 0.001). The difference of carotid IMT between normolipidemic xanthelasma and hyperlipidemic xanthelasma was not statistically different (mean +/- SD: 1.1 +/- 0.1 and 1.1 +/- 0.2 mm, respectively; P = 0.577). CONCLUSION: Premature carotid atherosclerosis is observed in patients with normolipidemic and hyperlipidemic xanthelasma. Patients with xanthelasma should be considered to have an increased risk of cardiovascular disease independently to the level of plasma lipids. A larger number of patients is, however, needed to confirm this preliminary study.
Resumo:
OBJECT: Reversible cerebral vasoconstriction syndrome (RCVS) is described as a clinical and radiological entity characterized by thunderclap headaches, a reversible segmental or multifocal vasoconstriction of cerebral arteries with or without focal neurological deficits or seizures. The purpose of this study is to determine risk factors of poor outcome in patients presented a RCVS. METHODS: A retrospective multi-center review of invasive and non-invasive neurovascular imaging between January 2006 and January 2011 has identified 10 patients with criterion of reversible segmental vasoconstriction syndrome. Demographics data, vascular risks and evolution of each of these patients were analyzed. RESULTS: Seven of the ten patients were females with a mean age of 46 years. In four patients, we did not found any causative factors. Two cases presented RCVS in post-partum period between their first and their third week after delivery. The other three cases were drug-induced RCVS, mainly vaso-active drugs. Cannabis was found as the causative factor in two patient, Sumatriptan identified in one patient while cyclosporine was the causative agent in also one patient. The mean duration of clinical follow-up was 10.2 months (range: 0-28 months). Two patients had neurological sequelae: one patient kept a dysphasia and the other had a homonymous lateral hemianopia. We could not find any significant difference of the evolution between secondary RCVS and idiopathic RCVS. The only two factors, which could be correlated to the clinical outcome were the neurological status at admission and the presence of intraparenchymal abnormalities (ischemic stroke, hematoma) in brain imaging. CONCLUSIONS: Fulminant vasoconstriction resulting in progressive symptoms or death has been reported in exceptional frequency. Physicians had to remember that such evolution could happen and predict them by identifying all factors of poor prognosis (neurological status at admission, the presence of intraparenchymal abnormalities).
Resumo:
The purpose of this study was to evaluate helical CT angiography in the assessment of occlusive arterial disease of abdominal aorta and the lower extremities. Sixteen patients underwent both transcatheter angiography and helical CT. Helical CT was inconclusive in 6.2% of segments whereas angiography was inconclusive in 5%. The overall sensitivity of helical CT was 91% and specificity 93%. Segmental analysis found a sensitivity of 43% in infrapopliteal arteries, and a specificity of 86%.
Resumo:
A male infant showed a humeral diaphysis fracture at 5 months of age and a distal tibial physis fracture at 2 years of age. A specialized consultant ruled out child abuse. This child had the characteristic features of type I osteogenesis imperfecta: blue sclerae, osseous fragility, and presumably autosomal dominant inheritance, as his father suffered from similar disorders. Later on, multiple painful osteochondromas were also found and some of these were surgically treated. The child's mother showed several peripheral osteochondromas. We describe the follow-up of this patient up to the age of 18 years. To our knowledge, the fortuitous association of these two inherited conditions has not been reported in medical literature.
Resumo:
Seven tesla (T) MR imaging is potentially promising for the morphologic evaluation of coronary arteries because of the increased signal-to-noise ratio compared to lower field strengths, in turn allowing improved spatial resolution, improved temporal resolution, or reduced scanning times. However, there are a large number of technical challenges, including the commercial 7 T systems not being equipped with homogeneous body radiofrequency coils, conservative specific absorption rate constraints, and magnified sample-induced amplitude of radiofrequency field inhomogeneity. In the present study, an initial attempt was made to address these challenges and to implement coronary MR angiography at 7 T. A single-element radiofrequency transmit and receive coil was designed and a 7 T specific imaging protocol was implemented, including significant changes in scout scanning, contrast generation, and navigator geometry compared to current protocols at 3 T. With this methodology, the first human coronary MR images were successfully obtained at 7 T, with both qualitative and quantitative findings being presented.
Resumo:
Magnetic resonance angiography (MRA) provides a noninvasive means to detect the presence, location and severity of atherosclerosis throughout the vascular system. In such studies, and especially those in the coronary arteries, the vessel luminal area is typically measured at multiple cross-sectional locations along the course of the artery. The advent of fast volumetric imaging techniques covering proximal to mid segments of coronary arteries necessitates automatic analysis tools requiring minimal manual interactions to robustly measure cross-sectional area along the three-dimensional track of the arteries in under-sampled and non-isotropic datasets. In this work, we present a modular approach based on level set methods to track the vessel centerline, segment the vessel boundaries, and measure transversal area using two user-selected endpoints in each coronary of interest. Arterial area and vessel length are measured using our method and compared to the standard Soap-Bubble reformatting and analysis tool in in-vivo non-contrast enhanced coronary MRA images.
Resumo:
Introduction: A hybrid intervention is a joint procedure involving the interventional cardiologist and the cardiac surgeon. At our institution we have opted for this type of approach in congenital heart disease since 2005. We report here our initial experience. Cases: 1. A 3 year old boy with double aortic arch and multiple muscular ventricular septal defects (VSD),was readdressed for pulmonary band (PAB) removal and residual VSD closure after previous palliation. After surgical removal of the PAB, the surgeon provided a minimal transventricular access for placement of a 6mm Amplatzer® muscular VSD occluder by the cardiologist under transoesophageal guidance. The patient was extubated the same day and discharged after 5 days. 2. An 8 year old girl with Williams syndrome was followed for two large VSDs and severe peripheral pulmonary arteries (PA) stenosis. The membranous VSD was closed surgically, the muscular VSD during the same operation by direct placement of a 12 mm Amplatzer® muscular VSD occluder. During rewarming, balloon angioplasty of peripheral PA stenosis was achieved under fluoroscopy. Patient was extubated the following day and discharged after 8 days. 3. A 9 year old boy post tetralogy of Fallot repair had severe distal stenosis of the right ventricular to PA conduit.With patient on partial cardiopulmonary bypass, an incision was made on the conduit and a CP 8 Zig 16 stent placed on the stenosis. The child passed on full bypass and the definitive placement of the stent achieved. The child was extubated at the end of the intervention and discharged after 6 days. 4. A newborn presented at 2 days life with complex aortic arch anatomy: left aortic arch and right descending thoracic aorta perfused directly from a right arterial duct and left PA atresia. The arterial duct was stented with a Genesis XD stent dilated at 7mm. Two days later the cardiac surgeon made banded the right PA. The child was extubated after the operation and discharged a week later. Conclusion: Hybrid approach opens new ways of correction or palliation in congenital heart disease with encouraging results and less morbidity.
Resumo:
The object of this study was to evaluate the contribution of carotid distensibilty on baroreflex sensitivity in patients with type 2 diabetes mellitus with at least 2 additional cardiovascular risk factors. Carotid distensibility was measured bilaterally at the common carotid artery in 79 consecutive diabetic patients and 60 matched subjects without diabetes. Spontaneous baroreflex sensitivity assessment was obtained using time and frequency methods. Baroreflex sensitivity was lower in diabetic subjects as compared with nondiabetic control subjects (5.25+/-2.80 ms/mm Hg versus 7.55+/-3.79 ms/mm Hg; P<0.01, respectively). Contrary to nondiabetic subjects, diabetic subjects showed no significant correlation between carotid distensibility and baroreflex sensitivity (r2=0.08, P=0.04 and r2=0.04, P=0.13, respectively). In diabetic subjects, baroreflex sensitivity was significantly lower in subjects with peripheral neuropathy than in those with preserved vibration sensation (4.1+/-0.5 versus 6.1+/-0.4 ms/mm Hg, respectively; P=0.005). Age in nondiabetic subjects, diabetes duration, systolic blood pressure, peripheral or sensitive neuropathy, and carotid distensibility were introduced in a stepwise multivariate analysis to identify the determinants of baroreflex sensitivity. In diabetic patients, neuropathy is a more sensitive determinant of baroreflex sensitivity than the reduced carotid distensibility (stepwise analysis; F ratio=5.1, P=0.028 versus F ratio=1.9, P=0.16, respectively). In diabetic subjects with 2 additional cardiovascular risk factors, spontaneous baroreflex sensitivity is not related to carotid distensibility. Diabetic subjects represent a particular population within the spectrum of cardiovascular risk situations because of the marked neuropathy associated with their metabolic disorder. Therefore, neuropathy is a more significant determinant of baroreflex sensitivity than carotid artery elasticity in patients with type 2 diabetes.
Resumo:
PURPOSE: To explore the use of telementoring for distant teaching and training in endovascular aortic aneurysm repair (EVAR). METHODS: According to a prospectively designed study protocol, 48 patients underwent EVAR: the first 12 patients (group A) were treated at a secondary care center by an experienced interventionist, who was training the local team; a further 12 patients (group B) were operated by the local team at their secondary center with telementoring by the experienced operator from an adjacent suite; and the last 24 patients (group C) were operated by the local team with remote telementoring support from the experienced interventionist at a tertiary care center. Telementoring was performed using 3 video sources; images were transmitted using 4 ISDN lines. EVAR was performed using intravascular ultrasound and simultaneous fluoroscopy to obtain road mapping of the abdominal aorta and its branches, as well as for identifying the origins of the renal arteries, assessing the aortic neck, and monitoring the attachment of the stent-graft proximally and distally. RESULTS: Average duration of telementoring was 2.1 hours during the first 12 patients (group B) and 1.2 hours for the remaining 24 patients (group C). There was no difference in procedural duration (127+/-59 minutes in group A, 120+/-4 minutes in group B, and 119+/-39 minutes in group C; p=0.94) or the mean time spent in the ICU (26+/-15 hours in group A, 22+/-2 hours in group B, and 22+/-11 hours for group C; p=0.95). The length of hospital stay (11+/-4 days in group A, 9+/-4 days in group B, and 7+/-1 days in group C; p=0.002) was significantly different only for group C versus A (p=0.002). Only 1 (8.3%) patient (in group A: EVAR performed by the experienced operator) required conversion to open surgery because of iliac artery rupture. This was the only conversion (and the only death) in the entire study group (1/12 in group A versus 0/36 in groups B + C, p=0.31). CONCLUSIONS: Telementoring for EVAR is feasible and shows promising results. It may serve as a model for development of similar projects for teaching other invasive procedures in cardiovascular medicine.
Resumo:
BACKGROUND: So far, none of the existing methods on Murray's law deal with the non-Newtonian behavior of blood flow although the non-Newtonian approach for blood flow modelling looks more accurate. MODELING: In the present paper, Murray's law which is applicable to an arterial bifurcation, is generalized to a non-Newtonian blood flow model (power-law model). When the vessel size reaches the capillary limitation, blood can be modeled using a non-Newtonian constitutive equation. It is assumed two different constraints in addition to the pumping power: the volume constraint or the surface constraint (related to the internal surface of the vessel). For a seek of generality, the relationships are given for an arbitrary number of daughter vessels. It is shown that for a cost function including the volume constraint, classical Murray's law remains valid (i.e. SigmaR(c) = cste with c = 3 is verified and is independent of n, the dimensionless index in the viscosity equation; R being the radius of the vessel). On the contrary, for a cost function including the surface constraint, different values of c may be calculated depending on the value of n. RESULTS: We find that c varies for blood from 2.42 to 3 depending on the constraint and the fluid properties. For the Newtonian model, the surface constraint leads to c = 2.5. The cost function (based on the surface constraint) can be related to entropy generation, by dividing it by the temperature. CONCLUSION: It is demonstrated that the entropy generated in all the daughter vessels is greater than the entropy generated in the parent vessel. Furthermore, it is shown that the difference of entropy generation between the parent and daughter vessels is smaller for a non-Newtonian fluid than for a Newtonian fluid.
Resumo:
BACKGROUND: Combined simultaneous occlusion of the central retinal artery and central retinal vein occurs very rarely and has been observed in patients with systemic disorders such as leukaemia. CASE REPORT: We report a case of a young man who suffered a combined retinal vascular occlusion with occlusion of the posterior ciliary arteries following blunt trauma to the face with massive haematoma of the lids. To our knowledge, this is the first time that such a sequence of events has been recorded.
Resumo:
Accurate measurement of knee kinematics during functional activities suffers mainly from soft tissue artifact (STA): the combination of local surface deformations and rigid movement of markers relative to the underlying bone (also called rigid STA movement: RSTAM). This study proposes to assess RSTAM on the thigh, shank, and knee joint and to observe possible features between subjects. Nineteen subjects with knee arthroplasty were asked to walk on a treadmill while a biplane fluoroscopic system (X-rays) and a stereophotogrammetric system (skin markers) recorded their knee movement. The RSTAM was defined as the rigid movement of the cluster of skin markers relative to the prosthesis. The results showed that RSTAM amplitude represents approximately 80-100% of the STA. The vertical axis of the anatomical frame of the femur was influenced the most by RSTAM. Combined with tibial error, internal/external rotation angle and distraction-compression were the knee kinematics parameters most affected by RSTAM during the gait cycle, with average rms values of 3.8° and 11.1 mm. This study highlighted higher RSTAM during the swing phase particularly in the thigh segment and suggests new features for RSTAM such as the particular shape of some RSTAM waveforms and the absence of RSTAM in certain kinematics during the gait phases. The comparison of coefficient of multiple correlations showed some similarities of RSTAM between subjects, while some correlations were found with gait speed and BMI. These new insights could potentially allow the development of new methods of compensation to avoid STA.
Resumo:
OBJECTIVE: Transcranial Doppler (TCD) is widely used to monitor the temporal course of vasospasm after subarachnoid hemorrhage (SAH), but its ability to predict clinical deterioration or infarction from delayed cerebral ischemia (DCI) remains controversial. We sought to determine the prognostic utility of serial TCD examination after SAH. METHODS: We analyzed 1877 TCD examinations in 441 aneurysmal SAH patients within 14 days of onset. The highest mean blood flow velocity (mBFV) value in any vessel before DCI onset was recorded. DCI was defined as clinical deterioration or computed tomographic evidence of infarction caused by vasospasm, with adjudication by consensus of the study team. Logistic regression was used to calculate adjusted odds ratios for DCI risk after controlling for other risk factors. RESULTS: DCI occurred in 21% of patients (n = 92). Multivariate predictors of DCI included modified Fisher computed tomographic score (P = 0.001), poor clinical grade (P = 0.04), and female sex (P = 0.008). After controlling for these variables, all TCD mBFV thresholds between 120 and 180 cm/s added a modest degree of incremental predictive value for DCI at nearly all time points, with maximal sensitivity by SAH day 8. However, the sensitivity of any mBFV more than 120 cm/s for subsequent DCI was only 63%, with a positive predictive value of 22% among patients with Hunt and Hess grades I to III and 36% in patients with Hunt and Hess grades IV and V. Positive predictive value was only slightly higher if mBFV exceeded 180 cm/s. CONCLUSION: Increased TCD flow velocities imply only a mild incremental risk of DCI after SAH, with maximal sensitivity by day 8. Nearly 40% of patients with DCI never attained an mBFV more than 120 cm/s during the course of monitoring. Given the poor overall sensitivity of TCD, improved methods for identifying patients at high risk for DCI after SAH are needed.
Resumo:
Résumé: La qualité de l'implantation d'une prothèse totale du genou est un facteur essentiel déterminant le résultat clinique à long terme. L'alignement postopératoire des membres inférieurs est considéré comme le facteur influençant le plus la survie à long terme d'une arthroplastie du genou. Au vu du haut degré de corrélation entre les complications post-opératoires et les malpositionnements prothétiques, les chirurgiens ont tenté de développer durant ces deux dernières décennies des instruments chirurgicaux améliorant la précision d'implantation. Depuis le début des années 90, de nouvelles instrumentations assistées par ordinateur ont été proposées. Actuellement, en chirurgie prothétique du genou, la plus utilisée de ces techniques est le système de navigation OrthoPilot® qui permet, grâce à une station de navigation et des émetteurs infrarouges, de contrôler en continu pendant l'opération, l'axe mécanique du membre inférieur et de vérifier la précision des coupes osseuses. Le but de cette étude de cohorte appareillée rétrospective est de comparer les résultats clinique et radiologiques de deux collectifs de patients (32 patients dans chaque groupe) comparables (âge, sexe, BMI, degré d'arthrose, recul postopératoire), opérés avec le même type de prothèse (prothèse à glissement tricompartimental postérieurement stabilisée), soit avec le système de navigation Orthopilot®, soit à l'aide de l'instrumentation ancillaire mécanique classique. Les résultats obtenus montrent que la technique chirurgicale supportée par le système de navigation Orthopilot® est fiable et aisément reproductible. Par rapport à l'instrumentation manuelle, l'instrumentation assistée améliore significativement la précision de pose du composant tibial dans le plan frontal. Cependant entre des mains expérimentées, la technique d'alignement mécanique classique, plus simple, reste performante (coût modique, temps opératoire plus court et sans risque de défaillance technique).
Resumo:
PURPOSE: Determine the effect of repeated intravitreal injections of ranibizumab (0.5 mg; 0.05 ml) on retrobulbar blood flow velocities (BFVs) using ultrasound imaging quantification in twenty patients with exudative age-related macular degeneration treated for 6 months. METHODS: Visual acuity (ETDRS), central macular thickness (OCT), peak-systolic, end-diastolic and mean-BFVs in central retinal (CRA), temporal posterior ciliary (TPCA) and ophthalmic (OA) arteries were measured before, 2 days, 3 weeks and 6 months after the first injection. Patients were examined monthly and received 1-5 additional injections depending on ophthalmologic examination results. RESULTS: Six months after the first injection, a significant increase in visual acuity 50.9 ± 25.9 versus 44.4 ± 21.7 (p < 0.01) and decrease in mean central macular thickness 267 ± 74 versus 377 ± 115 μm (p < 0.001) were observed compared to baseline. Although mean-BFVs decreased by 16%±3% in CRA and 20%±5% in TPCA (p < 0.001) 2 days after the first injection, no significant change was seen thereafter. Mean-BFVs in OA decreased by 19%±5% at week 3 (p < 0.001). However, the smallest number of injections (two injections) was associated with the longest time interval between the last injection and month 6 (20 weeks) and with the best return to baseline levels for mean-BFVs in CRA, suggesting that ranibizumab had reversible effects on native retinal vascular supply after its discontinuation. Moreover, a significant correlation between the number of injections and percentage of changes in mean-BFVs in CRA was observed at month 6 (R = 0.74, p < 0.001) unlike TPCA or OA. CONCLUSION: Ranibizumab could impair the native choroidal and retinal vascular networks, but its effect seems reversible after its discontinuation.