941 resultados para Threshold intensities


Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE. To assess the safety of transcorneal electrical stimulation (TES) and explore its efficacy in various subjective and objective parameters of visual function in patients with retinitis pigmentosa (RP). METHODS. Twenty-four patients in this prospective, randomized, partially blinded, good-clinical-practice study underwent TES (5-ms biphasic pulses; 20 Hz; DTL electrodes) 30 minutes per week for 6 consecutive weeks. The patients were randomly assigned to one of three groups: sham, 66%, or 150% of individual electrical phosphene threshold (EPT). Visual acuity (VA), visual field (VF; kinetic, static), electroretinography (Ganzfeld, multifocal), dark-adaptation (DA), color discrimination, and EPTs were assessed at all visits or four times, according to the study plan. RESULTS. TES using DTL electrodes was tolerated well; all patients finished the study. Two adverse (foreign body sensation), but no serious adverse events were encountered. There was a tendency for most functional parameters to improve (8/18) or to remain constant (8/18) in the 150% group. VF area and scotopic b-wave amplitude reached statistical significance (P < 0.027 and P < 0.001, respectively). Only desaturated color discrimination and VF mean sensitivity decreased. There was no obvious trend in the 66% group. CONCLUSIONS. TES was found to be safe in RP patients. Positive trends were discovered, but due to the small sample size of this exploratory study, statistical significance was reached only for VF area and scotopic b-wave amplitude. Further studies with larger sample sizes and longer duration are needed to confirm the findings and to define optimal stimulation parameters. (ClinicalTrials.gov number, NCT00804102.) (Invest Ophthalmol Vis Sci. 2011;52:4485-4496) DOI:10.1167/iovs.10-6932

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background. The natural history of congenital cytomegalovirus (CMV) infection is scarcely known in populations with high maternal CMV seroprevalence. This study evaluated the birth prevalence, clinical findings at birth, and hearing outcome in CMV-infected children from such a population. Methods. Consecutively born infants were screened for the presence of CMV in urine and/or saliva specimens during the first 2 weeks after birth. Neonatal clinical findings were recorded, and CMV-infected children were tested to document hearing function during follow-up. A subset of mothers of CMV-infected infants were prenatally tested for the presence of anti-CMV immunoglobulin G antibodies. Results. Congenital CMV infection was confirmed in 87 (1.08%; 95% confidence interval [CI], 0.86%-1.33%) of 8047 infants. Seven infants (8.1%; 95% CI, 3.3%-15.9%) had at least 1 clinical finding suggestive of CMV infection, and 4 (4.6%; 95% CI, 1.3%-11.3%) had 13 findings of systemic disease. Sensorineural hearing loss was found in 5 (8.6%; 95% CI, 2.9%-19.0%) of 58 children tested at a median age of 21 months. Bilateral profound hearing loss was observed in 2 children, and the hearing threshold was 160 decibels in all 5 children with hearing loss, including 2 children born to mothers with probable nonprimary CMV infection. Conclusions. The results of this large newborn screening study in a population with high CMV seroimmunity provide additional evidence that congenital CMV disease occurs in populations with high seroprevalence rates, with a similar incidence of CMV-related hearing loss to that reported in the offspring of women from populations in developed countries with lower rates of seroimmunity to CMV.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

P>Cholinergic agonists and acetylcholinesterase inhibitors, such as neostigmine, produce a muscarinic receptor-mediated antinociception in several animal species that depends on activation of spinal cholinergic neurons. However, neostigmine causes antinociception in sheep only in the early, and not late, postoperative period. In the present study, a model of postoperative pain was used to determine the antinociceptive effects of bethanechol (a muscarinic agonist) and neostigmine administered intrathecally 2, 24 or 48 h after a plantar incision in a rat hind paw. Changes in the threshold to punctate mechanical stimuli were evaluated using an automated electronic von Frey apparatus. Mechanical hyperalgesia was obtained following plantar incision, the effect being stronger during the immediate (2 h) than the late post-surgical period. Bethanechol (15-90 mu g/5 mu L) or neostigmine (1-3 mu g/5 mu L) reduced incision-induced mechanical hyperalgesia, the effects of both drugs being more intense during the immediate (2 h) than the late post-surgical period. The ED(50) for bethanechol injected at 2, 24 and 48 h was 5.6, 51.9 and 82.5 mu g/5 mu L, respectively. The corresponding ED(50) for neostigmine was 1.62, 3.02 and 3.8 mu g/5 mu L, respectively. The decline in the antinociceptive potency of neostigmine with postoperative time is interpreted as resulting from a reduction in pain-induced activation of acetylcholine-releasing descending pathways. However, the similar behaviour of bethanechol in the same model points to an additional mechanism involving intrinsic changes in spinal muscarinic receptors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

ESTEVES, A. M., M. T. DE MELLO, M. PRADELLA-HALLINAN, and S. TUFIK. Effect of Acute and Chronic Physical Exercise on Patients with Periodic Leg Movements. Med. Sci. Sports Exerc., Vol. 41, No. 1,. pp. 237-242, 2009. Purpose: Nonpharmacological interventions may lead to an improvement in sleep quality. The objective of our study was to evaluate the effects of acute intensive exercise and chronic exercise on sleep patterns in patients with periodic leg movements (PLM). Methods: The study involved acute and chronic exercise. The acute intensive exercise group consisted of 22 volunteers who underwent a maximum effort test and a polysomnography (PSG) on the same night. The chronic exercise group included. 11 patients who performed 72 physical training sessions undergoing three PSG studies on the night of sessions 1, 36, and 72. Blood samples were collected from both acute and chronic groups for beta-endorphin dosage. Results: Our results showed that both forms of physical exercise lowered PLM levels. The acute physical exercise increased sleep efficiency, rapid eye movement (REM) sleep, and reduced wake after sleep onset, whereas the chronic physical exercise increased sleep efficiency, REM sleep, and reduced sleep latency. We also found a significant negative correlation between beta-endorphin release after acute intensive exercise and PLM levels (r = -0.63). Conclusion: Physical exercise may improve sleep patterns and reduce PLM levels. The correlation between beta-endorphin release after acute intensive exercise and PLM levels might be associated with the impact physical exercise has on the opiodergic system. We suggest that physical exercise may be a useful nonpharmacological treatment for PLM.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The magnitude of the basic reproduction ratio R(0) of an epidemic can be estimated in several ways, namely, from the final size of the epidemic, from the average age at first infection, or from the initial growth phase of the outbreak. In this paper, we discuss this last method for estimating R(0) for vector-borne infections. Implicit in these models is the assumption that there is an exponential phase of the outbreaks, which implies that in all cases R(0) > 1. We demonstrate that an outbreak is possible, even in cases where R(0) is less than one, provided that the vector-to-human component of R(0) is greater than one and that a certain number of infected vectors are introduced into the affected population. This theory is applied to two real epidemiological dengue situations in the southeastern part of Brazil, one where R(0) is less than one, and other one where R(0) is greater than one. In both cases, the model mirrors the real situations with reasonable accuracy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sloths (Bradypus sp.) are extremely sensitive animals that suffer with the destruction and fragmentation of forests. They present a low population growth rate and need to be further studied for the preservation of the specie. Thus, the aim of this study was to establish an efficient semen collection protocol as well as characterize sperm concentration, motility and morphology in order to contribute with information about the reproductive traits of this specie, which has never been described in the literature before. For that, nine Bradypus tridactylus males were captured during the wet season and six during the dry season, in Manaus (AM), located in the north region of Brazil, semen was collected by electroejaculation with shocks given in sequences of progressive intensities (minimum 20 mA and maximum 60 mA). All animals ejaculated small volumes of semen and in some of them, the volume ejaculated was not enough for a complete spermiogram. Physical characteristics observed on the collections of the wet season were different from those seen in the specimen collected in the dry season. Motility an vigor was very low and did not show forward progression, only oscillatory movement. After Spermac stain, spermatozoa presented a wide variety of defects; however, the differences in morphology were not significant between seasons. The morphology assessed by scanning electron microscopy shows that the head in both groups could be elongated, short or could have a base narrower than the apex and the midpiece narrowed abruptly, forming a nip in its transition to the tail. Although further studies are necessary to verify our preliminary findings concerning seasonal variation in sperm quality, these results demonstrate that semen can be safely collected from sloths by electroejaculation and provide the first reports of semen characteristics in this species. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The susceptibility of cattle and buffalos to chronic copper poisoning (CCP) was compared by using cattle (n = 10) and buffalo (n = 10) steers distributed into two copper supplemented (n = 6) and two control (n = 4) groups. Supplemented animals received 2 mg copper (Cu)/kg body weight daily for one week, with an additional 2 mg weekly until the end of the experiment (day 105). Three liver biopsies (day 0, 45, and 105) were obtained for mineral analyses; clinical examinations and blood samples were obtained every 15 days. Three supplemented cattle and two buffalos with typical manifestations of CCP died. There were no differences in the frequency of mortality between cattle and buffalos; hepatic copper concentration was higher in cattle than buffalos. These findings suggest that buffalos and cattle might be equally susceptible to CCP. However, buffalos accumulate less liver copper than cattle and have a lower threshold of hepatic Cu accumulation, which leads to clinical manifestation of CCP. (c) 2009 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: The purpose of this study was to compare 2 different interventions, global postural reeducation (GPR) and static stretching exercises (SS), in the treatment of women with temporomandibular disorders (TMDs). Methods: A total of 28 subjects with TMDs were randomized into 2 treatment groups: GPR, where therapy involved muscle global chain stretching, or SS, with conventional static stretching; but only 24 completed the study. Eight treatment sessions lasting 40 minutes each (weekly) were performed. Assessments were conducted at baseline, immediately after treatment end, and 2 months later. Measurements included pain intensity at the temporomandibular joint, headache, cervicalgia, teeth clenching, ear symptoms, restricted sleep, and difficulties for mastication, using a visual analogue scale. In addition, electromyographic activity and pain thresholds were measured at the masseter, anterior temporalis, stemocleidomastoid, and upper trapezius muscles. Two-way analysis of variance with Tukey post hoc test was used for between-group comparisons. Significance level was .05. Results: Comparing the pain assessments using the visual analogue scale, no significant differences were seen with the exception of severity of headaches at treatment end (GPR, 3.92 +/- 2.98 cm; SS, 1.64 +/- 1.66 cm; P < .024). In addition, no significant differences were seen for pain thresholds and for electromyographic activity (P > .05). Conclusions: For the subjects in this study, both GPR and SS were similarly effective for the treatment of TMDs with muscular component. They equally reduced pain intensity, increased pain thresholds, and decreased electromyographic activity. (J Manipulative Physiol Ther 2010;33:500-507)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective was to compare fracture toughness (K(Ic)), stress corrosion susceptibility coefficient (n), and stress intensity factor threshold for crack propagation (K(I0)) of two porcelains [VM7/Vita (V) and d.Sign/Ivoclar (D)], two glass-ceramics [Empress/Ivolcar (E1) and Empress2/Ivlocar (E2)] and a glass-infiltrated alumina composite [In-Ceram Alumina/Vita (IC)]. Disks were constructed according to each manufacturer`s processing method, and polished before induction of cracks by a Vickers indenter. Crack lengths were measured under optical microscopy at times between 0.1 and 100 h. Specimens were stored in artificial saliva at 37A degrees C during the whole experiment. K(Ic) and n were determined using indentation fracture method. K(I0) was determined by plotting log crack velocity versus log K(I). Microstructure characterization was carried out under SEM, EDS, X-ray diffraction and X-ray fluorescence. IC and E2 presented higher K(Ic) and K(I0) compared to E1, V, and D. IC presented the highest n value, followed by E2, D, E1, and V in a decreasing order. V and D presented similar K(Ic), but porcelain V showed higher K(I0) and lower n compared to D. Microstructure features (volume fraction, size, aspect ratio of crystalline phases and chemical composition of glassy matrix) determined K(Ic). The increase of K(Ic) value favored the increases of n and K(I0).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cutaneous leishmaniasis (CL) includes different clinical manifestations displaying diverse intensities of dermal Inflammatory infiltrate Diffuse CL (DCL) cases are hyporesponsive and lesions show very few lymphocytes and a predominance of macrophages In contrast localized CL (LCL) cases are responsive to leishmanial antigen and lesions exhibit granulocytes and mononuclear cell infiltration in the early phases changing to a pattern with numerous lymphocytes and macrophages later in the lesion Therefore different chemokines may affect the predominance of cell infiltration in distinct clinical manifestations In lesions from LCL patients we examined by flow cytometry the presence of different chemokines and their receptors in T cells and we verified a higher expression of CXCR3 in the early stages of LCL (less than 30 days of infection) and a higher expression of CCR4 in the late stages of disease (more than 60 days of infection) We also observed a higher frequency of T cells producing IL-10 in the late stage of LCL Using immunohistochemistry we observed a higher expression of CCL7 CCL17 in lesions from late LCL as well as CCR4 suggesting a preferential recruitment of regulatory T cells in the late LCL Comparing lesions from LCL and DCL patients we observed a higher frequency of CCL7 in DCL lesions These results point out the Importance of the chemokines defining the different types of cells recruited to the site of the infection which could be related to the outcome of infection as well as the clinical form observed (C) 2010 American Society for Histocompatibility and Immunogenetics Published by Elsevier Inc All rights reserved

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Detection and quantification of human papillomavirus (HPV) may help in predicting the evolution of HPV infection and progression of associated lesions. Objectives: We propose a novel protocol using consensus primers GP5+/6+ in a SYBR Green quantitative real-time (Q-RT) polymerase chain reaction (PCR). The strategy permits screening for HPV infection and viral load quantification simultaneously. Study design: DNA from 153 archived cervical samples, previously tested for HPV detection by GP5+/6+ PCR and typed by EIA-RLB (enzyme immunoassay-reverse line blot) or sequence analysis, was analysed using SYBR Green Q-RT PCR. Melting temperature assay (T(m)) and cycle threshold (C(t)) were used to evaluate HPV positivity and viral load. The T(m) in the range of 77-82 degrees C was considered to be positive for HPV-DNA. HPV results generated through GP5+/6+ conventional PCR were considered the gold standard against which sensitivity and specificity of our assay were measured. Results: Out of 104 HPV positive samples, 100 (96.2%) were also determined as positive by SYBR Green Q-RT PCR; of the 49 HPV-negative samples, all were determined as negative. There was an excellent positivity agreement (K = 0.94) between the SYBR Green Q-RT and the previous methods employed. The specificity and sensitivity were 100% and 96.2%, respectively. Comparison of SYBR Green Q-RT and TaqMan oligo-probe technologies gave an excellent concordance (pc = 0.95) which validated the proposed strategy. Conclusions: We propose a sensitive and easy-to-perform technique for HPV screening and viral load quantification simultaneously. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The electrical stimulation generated by the Cochlear Implant (CI) may improve the neural synchrony and hence contribute to the development of auditory skills in patients with Auditory Neuropathy / Auditory Dyssynchrony (AN/AD). Aim: Prospective cohort cross-sectional study to evaluate the auditory performance and the characteristics of the electrically evoked compound action potential (ECAP) in 18 children with AN/AD and cochlear implants. Material and methods: The auditory perception was evaluated by sound field thresholds and speech perception tests. To evaluate ECAP`s characteristics, the threshold and amplitude of neural response were evaluated at 80Hz and 35Hz. Results: No significant statistical difference was found concerning the development of auditory skills. The ECAP`s characteristics differences at 80 and 35Hz stimulation rate were also not statistically significant. Conclusion: The CI was seen as an efficient resource to develop auditory skills in 94% of the AN/AD patients studied. The auditory perception benefits and the possibility to measure ECAP showed that the electrical stimulation could compensate for the neural dyssynchrony caused by the AN/AD. However, a unique clinical procedure cannot be proposed at this point. Therefore, a careful and complete evaluation of each AN/AD patient before recommending a Cochlear Implant is advised. Clinical Trials: NCT01023932

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The main issue regarding pediatric audiology diagnosis is determining procedures to configure reliable results which can be used to predict frequency-specific hearing thresholds. Aim: To investigate the correlation between auditory steady-state response (ASSR) with other tests in children with sensorineural hearing loss. Methods: Prospective cross-sectional contemporary cohort study. Twenty-three children (ages 1 to 7; mean, 3 years old) were submitted to ASSR, behavioral audiometry, click audiometry brain stem response (ABR), tone burst ABR, and predicting hearing level from the acoustic reflex. Results: the correlation between behavioral thresholds and ASSR was (0.70- 0.93), for the ABR tone burst it was (0.73 -0.93), for the ABR click it was (0.83-0.89) only at 2k and 4 kHz. The match between the ASSR and the hearing threshold prediction rule was considered moderate. Conclusion: there was a significant correlation between the ASSR and audiometry, as well as between ABR click (2k and 4 kHz) and for the ABR tone burst. The acoustic reflex can be used to add information to diagnosis in children.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The aim of this research was to evaluate the fatigue behavior and reliability of monolithic computer-aided design/computer-assisted manufacture (CAD/CAM) lithium disilicate and hand-layer-veneered zirconia all-ceramic crowns. Materials and Methods: A CAD-based mandibular molar crown preparation, fabricated using rapid prototyping, served as the master die. Fully anatomically shaped monolithic lithium disilicate crowns (IPS e.max CAD, n = 19) and hand-layer-veneered zirconia-based crowns (IPS e.max ZirCAD/Ceram, n = 21) were designed and milled using a CAD/CAM system. Crowns were cemented on aged dentinlike composite dies with resin cement. Crowns were exposed to mouth-motion fatigue by sliding a WC-indenter (r = 3.18 mm) 0.7 mm lingually down the distobuccal cusp using three different step-stress profiles until failure occurred. Failure was designated as a large chip or fracture through the crown. If no failures occurred at high loads (> 900 N), the test method was changed to staircase r ratio fatigue. Stress level probability curves and reliability were calculated. Results: Hand-layer-veneered zirconia crowns revealed veneer chipping and had a reliability of < 0.01 (0.03 to 0.00, two-sided 90% confidence bounds) for a mission of 100,000 cycles and a 200-N load. None of the fully anatomically shaped CAD/CAM-fabricated monolithic lithium disilicate crowns failed during step-stress mouth-motion fatigue (180,000 cycles, 900 N). CAD/CAM lithium disilicate crowns also survived r ratio fatigue (1,000,000 cycles, 100 to 1,000 N). There appears to be a threshold for damage/bulk fracture for the lithium disilicate ceramic in the range of 1,100 to 1,200 N. Conclusion: Based on present fatigue findings, the application of CAD/CAM lithium disilicate ceramic in a monolithic/fully anatomical configuration resulted in fatigue-resistant crowns, whereas hand-layer-veneered zirconia crowns revealed a high susceptibility to mouth-motion cyclic loading with early veneer failures. Int J Prosthodont 2010; 23: 434-442.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The objective of this study was to evaluate the stress on the cortical bone around single body dental implants supporting mandibular complete fixed denture with rigid (Neopronto System-Neodent) or semirigid splinting system (Barra Distal System-Neodent). Methods and Materials: Stress levels on several system components were analyzed through finite element analysis. Focusing on stress concentration at cortical bone around single body dental implants supporting mandibular complete fixed dentures with rigid ( Neopronto System-Neodent) or semirigid splinting system ( Barra Distal System-Neodent), after axial and oblique occlusal loading simulation, applied in the last cantilever element. Results: The results showed that semirigid implant splinting generated lower von Mises stress in the cortical bone under axial loading. Rigid implant splinting generated higher von Mises stress in the cortical bone under oblique loading. Conclusion: It was concluded that the use of a semirigid system for rehabilitation of edentulous mandibles by means of immediate implant-supported fixed complete denture is recommended, because it reduces stress concentration in the cortical bone. As a consequence, bone level is better preserved, and implant survival is improved. Nevertheless, for both situations the cortical bone integrity was protected, because the maximum stress level findings were lower than those pointed in the literature as being harmful. The maximum stress limit for cortical bone (167 MPa) represents the threshold between plastic and elastic state for a given material. Because any force is applied to an object, and there is no deformation, we can conclude that the elastic threshold was not surpassed, keeping its structural integrity. If the force is higher than the plastic threshold, the object will suffer permanent deformation. In cortical bone, this represents the beginning of bone resorption and/or remodeling processes, which, according to our simulated loading, would not occur. ( Implant Dent 2010; 19:39-49)