979 resultados para Thoracic computed tomography scan


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Computed tomography (CT) is one of the most used modalities for diagnostics in paediatric populations, which is a concern as it also delivers a high patient dose. Research has focused on developing computer algorithms that provide better image quality at lower dose. The iterative reconstruction algorithm Sinogram-Affirmed Iterative Reconstruction (SAFIRE) was introduced as a new technique that reduces noise to increase image quality. Purpose: The aim of this study is to compare SAFIRE with the current gold standard, Filtered Back Projection (FBP), and assess whether SAFIRE alone permits a reduction in dose while maintaining image quality in paediatric head CT. Methods: Images were collected using a paediatric head phantom using a SIEMENS SOMATOM PERSPECTIVE 128 modulated acquisition. 54 images were reconstructed using FBP and 5 different strengths of SAFIRE. Objective measures of image quality were determined by measuring SNR and CNR. Visual measures of image quality were determined by 17 observers with different radiographic experiences. Images were randomized and displayed using 2AFC; observers scored the images answering 5 questions using a Likert scale. Results: At different dose levels, SAFIRE significantly increased SNR (up to 54%) in the acquired images compared to FBP at 80kVp (5.2-8.4), 110kVp (8.2-12.3), 130kVp (8.8-13.1). Visual image quality was higher with increasing SAFIRE strength. The highest image quality was scored with SAFIRE level 3 and higher. Conclusion: The SAFIRE algorithm is suitable for image noise reduction in paediatric head CT. Our data demonstrates that SAFIRE enhances SNR while reducing noise with a possible reduction of dose of 68%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To determine whether using different combinations of kVp and mAs with additional filtration can reduce the effective dose to a paediatric phantom whilst maintaining diagnostic image quality. Methods: 27 images of a paediatric AP pelvis phantom were acquired with different kVp, mAs and additional copper filtration. Images were displayed on quality controlled monitors with dimmed lighting. Ten diagnostic radiographers (5 students and 5 experienced radiographers) had eye tests to assess visual acuity before rating the images. Each image was rated for visual image quality against a reference image using 2 alternative forced choice software using a 5-point Likert scale. Physical measures (SNR and CNR) were also taken to assess image quality. Results: Of the 27 images rated, 13 of them were of acceptable image quality and had a dose lower than the image with standard acquisition parameters. Two were produced without filtration, 6 with 0.1mm and 5 with 0.2mm copper filtration. Statistical analysis found that the inter-rater and intra-rater reliability was high. Discussion: It is possible to obtain an image of acceptable image quality with a dose that is lower than published guidelines. There are some areas of the study that could be improved. These include using a wider range of kVp and mAs to give an exact set of parameters to use. Conclusion: Additional filtration has been identified as amajor tool for reducing effective dose whilst maintaining acceptable image quality in a 5 year old phantom.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Since the first in vivo studies of cerebral function with radionuclides by Ingvar and Lassen, nuclear medicine (NM) brain applications have evolved dramatically, with marked improvements in both methods and tracers. Consequently it is now possible to assess not only cerebral blood flow and energy metabolism but also neurotransmission. Planar functional imaging was soon substituted by single-photon emission computed tomography (SPECT) and positron emission tomography (PET); it now has limited application in brain imaging, being reserved for the assessment of brain death.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A TC é um valioso método diagnóstico radiológico. O exame TC pode expor o paciente a uma dose elevada de exposição à radiação, causando risco acrescido. Uma das possíveis soluções para a redução da dose é o uso de técnicas de reconstrução iterativa (IR) em vez das reconstruções tradicionais (FBP). Com base nas suas capacidades de redução de ruído na imagem, a IR pode ter o potencial de reduzir significativamente a dose em pacientes submetidos a TC sem prejudicar a qualidade de imagem. Manter a qualidade de imagem clínica com um nível de qualidade aceitável e expondo o paciente à menor dose possível.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mestrado em Medicina Nuclear - Área de especialização: Tomografia por emissão de positrões

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A antropologia forense é uma disciplina das ciências forenses que trata da análise de restos cadavéricos humanos para fins legais. Uma das suas aplicações mais populares é a identificação forense que consiste em determinar o perfil biológico (idade, sexo, ancestralidade e estatura) de um indivíduo. No entanto, este processo muitas vezes é dificultado quando o corpo se encontra em avançado estado de decomposição apenas existindo restos esqueléticos. Neste caso, áreas médicas comummente utilizadas na identificação de cadáveres, como a patologia, tem de ser descartadas e surge a necessidade de aplicar outras técnicas. Neste contexto, muitos métodos antropométricos são propostos de forma a caracterizar uma pessoa através do seu esqueleto. Contudo, constata-se que a maioria dos procedimentos sugeridos é baseada em equipamentos básicos de medição, não usufruindo da tecnologia contemporânea. Assim, em parceria com a Delegação Norte do NMLCF, I. P., esta Tese teve na sua génese a criação de um sistema computacional baseado em imagens de Tomografia Computorizada (TC) de ossadas que, através de ferramentas open source, permita a realização de identificação forense. O trabalho apresentado baseia-se no processo de gestão de informação, aquisição, processamento e visualização de imagens TC. No decorrer da realização da presente Tese foi desenvolvida uma base de dados que permite organizar a informação de cada ossada e foram implementados algoritmos que levam a uma extracção de características muito mais vasta que a efetuada manualmente com os equipamentos de medição clássicos. O resultado final deste estudo consistiu num conjunto de técnicas que poderão ser englobadas num sistema computacional de identificação forense e deste modo criar uma aplicação com vantagens tecnológicas evidentes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: Coronary artery disease are associated with decreased levels of physical activity, contributing to increases in abdominal fat and consequently the metabolic risk. The use of microcurrents is an innovative and effective method to increase lipolytic rate of abdominal adipocytes. This study aims to investigate the effects of microcurrents with a homebased exercise program on total, subcutaneous and visceral abdominal adipose tissue in subjects with coronary artery disease. Methods: This controlled trial included 44 subjects with myocardial infarction, randomly divided into Intervention Group 1 (IG1; n = 16), Intervention Group 2 (IG2; n = 12) and Control Group (CG; n = 16). IG1 performed a specific exercise program at home during 8 weeks, and IG2 additionally used microcurrents on the abdominal region before the exercise program. All groups were subjected to health education sessions. Computed Tomography was used to evaluate abdominal, subcutaneous and visceral fat, accelerometers to measure habitual physical activity and the semiquantitative Food Frequency Questionnaire for dietary intake. Results: After 8 weeks, IG2 showed a significantly decreased in subcutaneous fat (p ≤ 0.05) when compared to CG. Concerning visceral fat, both intervention groups showed a significant decrease in comparison to the CG (p ≤ 0.05). No significant changes were found between groups on dietary intake and habitual physical activity, except for sedentary activity that decreased significantly in IG2 in comparison with CG (p ≤ 0.05). Conclusions: This specific exercise program showed improvements in visceral fat in individuals with coronary artery disease. Microcurrent therapy associated with a home-based exercise program suggested a decreased in subcutaneous abdominal fat.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

RESUMO - A preocupação com os conhecimentos, atitudes, crenças e práticas, no que concerne à utilização de radiações ionizantes para fins de diagnóstico, e a sensibilização de todos os agentes envolvidos, médicos, técnicos, físicos, utentes e responsáveis pela Saúde Publica, relativamente aos níveis de radiação emitida nos exames de Tomografia Computorizada (TC), assume particular importância no domínio da Saúde Pública, na medida em que é necessário influenciar o desenvolvimento de práticas que promovam, auditem e garantam a prestação do controlo da qualidade radiológica e dosimétrica nos serviços de Radiologia a nível Nacional. Para tal, e no âmbito da publicação de estudos já realizados ao nível da União Europeia, ―Orientações Europeias dos Critérios de Qualidade para a Tomografia Computorizada (1999) ‖, é proposto estabelecer orientações na realização de estudos que permitam, numa primeira fase, estabelecer a comparação com os resultados obtidos pelos mecanismos de Controlo da Qualidade (CQ), analisar e proceder aos ajustes (se necessário) e, numa segunda fase, implementar uma moldura sistemática de avaliação periódica dos níveis de dose de radiação por exame TC e que permita a monitorização dos dados. Nesse sentido, propõe-se a realização de um Estudo Nacional que envolva a rede hospitalar pública, privada e universitária, partindo da metodologia utilizada em estudos prévios noutros países da Europa, como seja, selecção do equipamento de TC existente na Instituição Hospitalar, onde serão reunidas informações através do preenchimento de questionários relativos ao equipamento a utilizar. Serão recolhidos dados relativos ao utente, ao equipamento e parâmetros de aquisição de imagem, que permitam identificar os níveis de referência de diagnóstico (NRD) em TC, na realidade Portuguesa. Foi efectuado um estudo piloto numa instituição EPE e os valores obtidos não são significativos, nem podem assumir valor preditivo dado o reduzido tamanho da amostra. Apesar disso, sugerem a existência de parâmetros que podem ser alterados e com isso podem fazer variar a dose de radiação utilizada. ENSP/UNL Maria de Fátima Vaz de Carvalho 5 Espera-se obter com este estudo, como foi referido, a base do estabelecimento dos NRD em TC em Portugal. ----------------- ABSTRACT - The purpose of this study, in an empirical point of view, emerges from concern with the knowledge, attitudes, beliefs and practices regarding the use of ionizing radiation for diagnostic purposes and awareness of all actors involved, medical physical, technical, and responsible public health for the development of practices that promote, audited and ensure the provision of radiological quality control and dosing in radiology service at national level. In view of the complexity and characteristics involved in relation to ionizing radiation, all assume their part in protecting the physical integrity of each user and a global perspective, to ensure the safeguarding of public health, while global and globalizing factor. To this end, and in the context of the publication of studies already carried out at European Union level, "European guidelines for quality criteria for computed tomography", it is proposed to establish guidelines in conducting studies to initially establish the comparison with the results obtained by QC and make adjustments if necessary, and subsequently implement a systematic periodic assessment frame that allows monitoring of data. Accordingly, it is proposed to conduct a national study involving the public network, private and University hospitals, that extends from the methodology used in previous studies in other countries of Europe, as is, selection of equipment of existing CT in Hospital Institution, where information will be gathered by filling out questionnaires concerning the equipment to be used. Data will be collected for the wearer, equipment and parameters of image acquisition, identifying diagnostic reference levels (NRD) in CT in Portuguese fact. A pilot study was carried out in an institution EPE and the values obtained are not significant, nor can they take predictive value given the small sample size. Despite this, suggest the existence of parameters that can be changed and this can vary the dose of radiation used It is hoped to get with this study, as mentioned, the basis of the establishment of NRD in CT in Portugal.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Orbital myositis is a subgroup of the nonspecific inflammatory syndrome or orbital pseudotumor and is characterized by a primary inflammation of extraocular muscles. The authors describe a 70-year-old patient with acute proptosis, ocular pain and right ophthalmoplegia, whose orbital computed tomographic scan showed enlargement of the homolateral extraocular muscles. Clinical presentation and complementary tests were compatible with the diagnosis of orbital myositis however, because of the particular aspects, which included retinal central vein occlusion, optic nerve lesion, distension of the superior ophthalmic vein and the homolateral cavernous sinus, the differential diagnosis with cavernous sinus pathology and thyroid ophthalmopathy was considered. The importance of a rapid diagnosis and treatment is stressed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Non-Hodgkin's lymphomas (NHL) are the second most frequent malignancies in AIDS patients. The majority of NHL associated with AIDS involves extranodal sites, especially the digestive tract and the central nervous system. Primary liver lymphoma (PLL) is an uncommon neoplasm among these patients. Ultrasonography and computed tomography scans may be helpful in the diagnosis of focal hepatic lymphoma. Image-guided fine-needle biopsy with histopathology of the liver lesions is the gold standard for the diagnosis of hepatic lymphoma. We report a case of PLL as the initial manifestation of AIDS in a patient without any previous infection by hepatitis C or B virus, presented as multiple and large hepatic masses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Sera from 88 patients from Santa Catarina and São Paulo states of Brazil, with epileptic seizures who underwent cerebral computed tomography (CT) were analyzed for the detection of antibodies to T. solium cysticercus by ELISA and Immunoblot (IB) with the following antigens: Taenia solium cysticercus total saline (Tso), Taenia crassiceps cysticercus vesicular fluid (Tcra-vf) and T. crassiceps cysticercus glycoproteins (Tcra-gp). ELISA carried out with Tso, Tcra-vf and Tcra-gp antigens showed 95%, 90% and 80% sensitivities, respectively, and 68%, 85% and 93% specificities, respectively. In the epileptic patients group, ELISA positivity was 30%, 51% and 35% with Tso, Tcra-vf and Tcra-gp antigens respectively. Considering the IB as the confirmatory test, the positivity was 16% (14/88) in the epileptic patients total group and 22% (12/54) in the epileptic patients with positive CT and signals of cysticercosis. We found a significant statistical correlation among ELISA or IB results and the phase of the disease when any antigens were used (p < 0.05). We emphasize the need to introduce in the laboratory routine the search for neurocysticercosis (NC) in patients presenting with epileptic seizures because of the high risk of acquiring NC in our region and its potential cause of epilepsy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to develop a bone substitute material capable of preventing or treating osteomyelitis through a sustainable release of vancomycin and simultaneously inducing bone regeneration. Porous heparinized nanohydroxyapatite (nanoHA)/collagen granules were characterized using scanning electron microscopy, micro-computed tomography and attenuated total reflectance Fourier transform infrared spectroscopy. After vancomycin adsorption onto the granules, its releasing profile was studied by UV molecular absorption spectroscopy. The heparinized granules presented a more sustainable release over time, in comparison with nonheparinized nanoHA and nanoHA/collagen granules. Vancomycin was released for 360 h and proved to be bioactive until 216 h. Staphylococcus aureus adhesion was higher on granules containing collagen, guiding the bacteria to the material with antibiotic, improving their eradication. Moreover, cytotoxicity of the released vancomycin was assessed using osteoblast cultures, and after 14 days of culture in the presence of vancomycin, cells were able to remain viable, increasing their metabolic activity and colonizing the granules, as observed by scanning electron microscopy and confocal laser scanning microscopy. These findings suggest that heparinized nanoHA/collagen granules are a promising material to improve the treatment of osteomyelitis, as they are capable of releasing vancomycin, eliminating the bacteria, and presented morphological and chemical characteristics to induce bone regeneration.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction Coronary artery disease is associated with decreased levels of physical activity, contributing to increases in abdominal fat and consequently increasing metabolic risk. The innovative use of microcurrents may be an effective method to increase the lipolytic rate of abdominal adipocytes. This study aimed to investigate the effects of utilizing microcurrents in a home-based exercise program in subjects with coronary artery disease to assess changes in total, subcutaneous and visceral abdominal adipose tissue. Methods This controlled trial included 44 subjects with myocardial infarction, randomly divided into Intervention Group 1 (IG1; n = 16), Intervention Group 2 (IG2; n = 12) and Control Group (CG; n = 16). IG1 performed a specific exercise program at home during 8 weeks, and IG2 additionally used microcurrents on the abdominal region before the exercise program. All groups were given health education sessions. Computed tomography was used to evaluate abdominal, subcutaneous and visceral fat, accelerometers to measure habitual physical activity and the semi-quantitative food frequency questionnaire for dietary intake. Results After 8 weeks, IG2 showed a significantly decrease in subcutaneous fat (p ≤ 0.05) when compared to CG. Concerning visceral fat, both intervention groups showed a significant decrease in comparison to the CG (p ≤ 0.05). No significant changes were found between groups on dietary intake and habitual physical activity, except for sedentary activity that decreased significantly for IG2 in comparison with CG (p ≤ 0.05). Conclusion This specific home-based exercise program using microcurrent therapy for individuals with coronary artery disease showed improvements in visceral and subcutaneous abdominal fat.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Long-term follow-up after endovascular aneurysm repair (EVAR) is very scarce, and doubt remains regarding the durability of these procedures. We designed a retrospective cohort study to assess long-term clinical outcome and morphologic changes in patients with abdominal aortic aneurysms (AAAs) treated by EVAR using the Excluder endoprosthesis (W. L. Gore and Associates, Flagstaff, Ariz). METHODS: From 2000 to 2007, 179 patients underwent EVAR in a tertiary institution. Clinical data were retrieved from a prospective database. All patients treated with the Excluder endoprosthesis were included. Computed tomography angiography (CTA) scans were retrospectively analyzed preoperatively, at 30 days, and at the last follow-up using dedicated tridimensional reconstruction software. For patients with complications, all remaining CTAs were also analyzed. The primary end point was clinical success. Secondary end points were freedom from reintervention, sac growth, types I and III endoleak, migration, conversion to open repair, and AAA-related death or rupture. Neck dilatation, renal function, and overall survival were also analyzed. RESULTS: Included were 144 patients (88.2% men; mean age, 71.6 years). Aneurysms were ruptured in 4.9%. American Society of Anesthesiologists classification was III/IV in 61.8%. No patients were lost during a median follow-up of 5.0 years (interquartile range, 3.1-6.4; maximum, 11.2 years). Two patients died of medical complications ≤ 30 days after EVAR. The estimated primary clinical success rates at 5 and 10 years were 63.5% and 41.1%, and secondary clinical success rates were 78.3% and 58.3%, respectively. Sac growth was observed in 37 of 142 patients (26.1%). Cox regression showed type I endoleak during follow-up (hazard ratio, 3.74; P = .008), original design model (hazard ratio, 3.85; P = .001), and preoperative neck diameter (1.27 per mm increase, P = .006) were determinants of sac growth. Secondary interventions were required in 32 patients (22.5%). The estimated 10-year rate of AAA-related death or rupture was 2.1%. Overall life expectancy after AAA repair was 6.8 years. CONCLUSIONS: EVAR using the Excluder endoprosthesis provides a safe and lasting treatment for AAA, despite the need for maintained surveillance and secondary interventions. At up to 11 years, the risk of AAA-related death or postimplantation rupture is remarkably low. The incidences of postimplantation sac growth and secondary intervention were greatly reduced after the introduction of the low-permeability design in 2004.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A metastização óssea para a cabeça e pescoço é rara. Em 20-35% dos casos, pode ser a primeira manifestação de uma neoplasia oculta. No caso específico do osso temporal, as metástases são originárias, mais frequentemente, da mama, pulmão, rim, próstata e estômago. Apresenta-se o caso clínico de uma doente, do sexo feminino, 71 anos, com Diagnóstico de Carcinoma Ductal tipo Cribiforme na mama esquerda, tendo sido submetida a mastectomia total, quimioterapia e radioterapia. À observação apresentava um quadro clínico de otalgia esquerda, associada a paralisia facial da hemiface ipsilateral, sem outros sintomas otológicos. Foi-lhe diagnosticada Otite Média Crónica agudizada, tendo sido medicada e pedida Tomografia Computorizada ao Ouvido Esquerdo, que demonstrou exuberante espessamento dos tecidos moles epicranianos temporo-parieto-occipitais à esquerda com extensão ao canal auditivo externo do mesmo lado. Por agravamento da sintomatologia, foi internada no Serviço de Otorrinolaringologia deste hospital para administração de terapêutica endovenosa, tendo-se admitido a hipótese diagnóstica de Otite Externa Maligna. Por manutenção do quadro, apesar de terapêutica optimizada, foi submetida a intervenção cirúrgica onde foi efectuada biopsia temporal, tendo sido diagnosticado lesão metastática por carcinoma invasivo da mama.