895 resultados para Test-retest Reliability
Resumo:
Helicobacter pylori was investigated in 189 patients for culture, microscopic visualization of campylobacter-like organisms (CLO) and a ten minute urease test. In 136 (72%) the bacteria was isolated, and in 98 of them CLO were histologically detected. Specificity, sensitivity, positive and negative predictive values of microscopic visualization of CLO were: 0.77, 0.73, 0.97 and 0.51, respectively; 98 culture-positive patients were urease test positive. Specificity, sensitivity, positive and negative predictive values of the urease test were: 0.83, 0.72, 0.92 and 0.54, respectively. Comparing the urease test with culture of H. pylori combined with microscopic visualization of CLO, its specificity, sensitivity, positive and negative predictive values were: 0.95, 0.71, 0.98 and 0.48, respectively. Probably, these values are not real, since bacteria different from H. pylori could be misclassified as CLO.
Resumo:
The performance of an antigen of L. major-like promastigotes for the serological diagnosis of mucocutaneous leishmaniasis in the IgG-immunofluorescent test was compared to that of an antigen of L. braziliensis braziliensis. Each antigen was used to test two hundred and twenty-four sera of etiologies such as mucocutaneous leishmaniasis, deep mycoses, toxoplasmosis, malaria, Chagas' disease, visceral leishmaniasis, anti-nuclear factor, schistosomaiasis, rheumatoid factor and normal controls. Agreement between responses to each antigen was high: 77.2% of leishmaniases sera agreed on a positive or a negative result to both antigens and 91.1 % of control sera. Cross reactivity was restricted to Chagas' disease sera, visceral leishmaniasis, anti-nuclear factor and paracoccidiodomycosis. The quantitative response of leishmaniasis and Chagas' disease sera to both antigens was evaluated by a linear regression; although the y-intercept and the slope were different for each antigen, neither was better than the other in the disclosure of anti-Leishmania antibodies. In the case of Chagas' disease sera the L. major-like antigen was better than L. b. braziliensis' to disclose cross-reacting antibodies.
Resumo:
A relação entre consciência fonológica e consciência morfológica e a contribuição independente de cada uma para a aprendizagem da leitura não reúnem ainda consenso na literatura. Alguns autores argumentam que a consciência morfológica não contribui de forma independente da consciência fonológica para a aprendizagem da leitura. No entanto, outros encontraram dados que indicam que a consciência morfológica tem um papel específi co na progressão da aprendizagem da leitura. Todavia, para além da variedade de tarefas usadas não permitir a comparação de resultados, a ausência de estudos prévios sobre a validade e a fi delidade das mesmas conduz a resultados cuja confi abilidade pode ser posta em causa. Este estudo tem como objetivo apresentar uma análise das qualidades psicométricas da PCM - Prova de Consciência Morfológica. A amostra é constituída por 243 crianças do 2.º (n = 79), 3.º (n = 83) e 4.º (n = 81) anos frequentando escolas públicas, urbanas, do distrito do Porto (norte de Portugal). Os resultados revelaram que a PCM possui uma elevada consistência interna (α = .95). Na análise em componentes principais, foi extraído um único fator, com valor próprio igual a 10.88, que explica 54.42% da variância total dos resultados. Os itens são todos saturados no fator, variando as saturações fatoriais entre um mínimo de .42 e o máximo de .91
Resumo:
Safety is one of the major concerns of process safety engineers in most industrial facilities all over the world. To this scope, some events play an important role once the effect of their consequences can be assumed as totally undesirable. One of these events refers to the occurrence of a fire. Such event can result in catastrophic consequences for life, equipment, and continuity of activities or even leading to environmental damage. A fire protection equipment with low reliability means that this equipment are often unavailable and thus the risk of a fire increases. Maintenance of fire protection equipment is very important because this kind of systems is mostly in a dormant mode, which gives uncertainty about their operability when demanded in a real situation of fire. This article outlines the importance of tests, inspection, and maintenance operations in the context of a fire sprinkler system and proposes a methodology based on international standards and supported by test/inspection reports to correct the frequency of these actions according to the level of degradation of the components and regarding safety purposes. © 2015 American Institute of Chemical Engineers.
Resumo:
Se evaluó la utilidad de la prueba de aglutinación directa (AD) para diagnosticar el Mal de Caderas. Se emplearon cuarenta y cuatro sueros provenientes de dos lotes de equinos naturalmente infectados con el Trypanosoma evansi (Lote 1 y Lote 2). La AD fue positiva (Aglutinación > 1:512) en 13 de 16 equinos (81.2%), de los que se aislaron los parásitos. En doce de estos animales (92%) se detectaron IgM anti T. evansi mediante la AD realizada con 2-mercaptoetanol (AD + 2-ME). La AD fue positiva en 17 de los 28 equinos que resultaron negativos al diagnóstico parasitológico. Un tercer lote de cinco equinos infectados con T. evansi que presentaba elevados títulos de AD, fue tratado con Suramina Sódica (Nagano1-Bayer). La AD + 2-ME evidenció en cuatro animales que, gran parte de estos anticuerpos se ubicaban en la fracción IgM. Posterior al tratamiento farmacológico y, en concordancia de la negativización de la parasitemia, la detección de la IgM anti T. evansi no fue posible, mientras que los anticuerpos IgG continuaron detectándose a los doce meses post-tratamiento en valores de 1:512, en tres animales. Cincuenta sueros de equinos de una zona libre del parásito, que se emplearon como controles, fueron negativos a la AD. Se recomienda la utilización de la AD y AD + 2-ME para el uso de rutina en el diagnóstico del Mal de Caderas de los equinos, en combinación con otros métodos parasitológicos sensibles.
Resumo:
A new serological test, the gelatin particle agglutination test (GPAT), was used for the serodiagnosis of schistosomiasis mansoni. This technique showed the sensitivity (90.6%) and specificity (97.8%) close to those of enzyme-linked immunosorbent assay. The GPAT can be easily and rapidly performed without specialized equipment, by using lyophilized antigen-coated gelatin particles. The test also seems to be useful for mass screening of Schistosoma infection in field conditions.
Resumo:
Eighty purulent cerebrospinal fluid (CSF) samples from patients with clinical evidence of meningitis were studied using the Directigen latex agglutination (LA) kit to determine the presence of bacterial antigen in CSF. The results showed a better diagnostic performance of the LA test than bacterioscopy by Gram stain, culture and counterimmunoelectrophoresis (CIE), as far as Neisseria meningitidis groups B and C, and Haemophilus influenzae type b are concerned, and a better performance than bacterioscopy and culture considering Streptococcus pneumoniae. Comparison of the results with those of culture showed that the LA test had the highest sensitivity for the Neisseria meningitidis group C. Comparing the results with those of CIE, the highest levels of sensitivity were detected for N. meningitidis groups B and C. Regarding specificity, fair values were obtained for all organisms tested. The degree of K agreement when the LA test was compared with CIE exhibited better K indices of agreement for N. meningitidis groups B and C.
Resumo:
Diversas alterações na concentração sérica dos hormônios tiroidianos têm sido descritas em associação a doenças crônicas não-tiroidianas. Com relação às doenças hepáticas crônicas, a síndrome do T3 baixo foi descrita em pacientes cirróticos, enquanto a síndrome do T4 elevado foi encontrada em esquistossomóticos com a forma hepatoesplênica compensada. Com o intuito de verificar se as alterações relatadas na esquistossomose mansônica eram de origem "periférica" ou "central", realizamos a prova do TRH-TSH em 12 pacientes esquistossomóticos "puros" (6 hepatointestinais e 6 hepatoesplênicos compensados) e em 5 indivíduos controle. Os resultados obtidos demonstram que o eixo hipotálamo-hipofisário é normal nas formas crônicas da esquistossomose e que provavelmente as alterações previamente relatadas devem ser '"periféricas" e não " centrais".
Resumo:
The rising usage of distributed energy resources has been creating several problems in power systems operation. Virtual Power Players arise as a solution for the management of such resources. Additionally, approaching the main network as a series of subsystems gives birth to the concepts of smart grid and micro grid. Simulation, particularly based on multi-agent technology is suitable to model all these new and evolving concepts. MASGriP (Multi-Agent Smart Grid simulation Platform) is a system that was developed to allow deep studies of the mentioned concepts. This paper focuses on a laboratorial test bed which represents a house managed by a MASGriP player. This player is able to control a real installation, responding to requests sent by the system operators and reacting to observed events depending on the context.
Resumo:
Most of distribution generation and smart grid research works are dedicated to the study of network operation parameters, reliability among others. However, many of this research works usually uses traditional test systems such as IEEE test systems. This work proposes a voltage magnitude study in presence of fault conditions considering the realistic specifications found in countries like Brazil. The methodology considers a hybrid method of fuzzy set and Monte Carlo simulation based on the fuzzyprobabilistic models and a remedial action algorithm which is based on optimal power flow. To illustrate the application of the proposed method, the paper includes a case study that considers a real 12 bus sub-transmission network.
Resumo:
A hemagglutination (HA) test was standardized using formalin- and tannin-treated gander red blood cells sensitized with a total salt extract of C. cellulosae (HA-Cc) and an antigenic extract of Cysticercus longicollis (HA-Cl) vesicular fluid. A total of 61 cerebrospinal fluid (CSF) samples were assayed, 41 from patients with neurocysticercosis and 20 from a control group, which were, respectively, reactive and non-reactive to ELISA using C. cellulosae. The CSF samples from the control group did not react and 35 (85.4%) and 34 (82.9%) CSF samples from patients were reactive to the HA-Cc and HA-Cl tests, respectively. The reagents ready for use were stable up to 6 months when stored at 4°C in 50% glycerol. The present results confirm that the reagent using Cysticercus longicollis stabilized with glycerol can be used as an alternative in the immunological diagnosis of neurocysticercosis
Resumo:
Most of distributed generation and smart grid research works are dedicated to network operation parameters studies, reliability, etc. However, many of these works normally uses traditional test systems, for instance, IEEE test systems. This paper proposes voltage magnitude and reliability studies in presence of fault conditions, considering realistic conditions found in countries like Brazil. The methodology considers a hybrid method of fuzzy set and Monte Carlo simulation based on the fuzzy-probabilistic models and a remedial action algorithm which is based on optimal power flow. To illustrate the application of the proposed method, the paper includes a case study that considers a real 12-bus sub-transmission network.
Resumo:
Mestrado em Engenharia Informática
Resumo:
A survey for canine tegumentary leishmaniasis (CTL) has been carried out between 1986 and 1993 in seven endemic localities for American cutaneous leishmaniasis in the State of Rio de Janeiro. 270 dogs have been examined for their clinical aspects, the development of delayed hypersensitivity (DHS) with Immunoleish antigen and with immunofluorescent antibody research of IgG (IF). 28.2% of them had ulcer lesions and 3.3% had scars. The lesions consisted of single (39.5%) and mucocutaneous lesions (31.6%), multiple cutaneous (25.0%) and mucocutaneous lesions associated with cutaneous ulcers (4.0%). Twelve (15.8%) isolates from biopsies were analyzed by zimodeme and schizodeme and identified as L. (V.) braziliensis. The overall prevalence of canine infection that was evaluated with the skin test was of 40.5% and with IF it was of 25.5%. Both tests showed a high positive rate with relation to the animals with mucosal lesions, as in the case of human mucocutaneous leishmaniasis. The comparison of the two tests showed the skin test to have a better performance although there was no statistical difference (p>0.05) between them. The proportional sensitivity and specificity was of 84.0% and 74.0%, respectively. The Immunoleish skin test and IF are useful tools to be employed in CTL field epidemiological surveys.