956 resultados para Tank destroyers
Resumo:
Several strategies are known for sanitizing dairy herd problems caused by Staphylococcus (S.) aureus. They mostly consist of general management measures but specific decision-making at an individual animal level has not been described. A sanitation program in the form of a process chart developed by the Bern Clinic for Ruminants was undertaken in 10 dairy herds with this problem. In an affected herd the cows were divided into 3 groups: healthy, suspect, infected. Three milk samples (MS), taken at two-week intervals were cultivated. The cows were grouped according to the culture results. To measure the success of the sanitation program, the key figures <
Indices for daily temperature and precipitation extremes in Europe analysed for the period 1901-2000
Resumo:
Mycobacterium marinum can cause fish tank granuloma (or swimming pool or aquarium granuloma) in immunocompetent patients. Dissemination of Mycobacterium marinum-infection is a rare condition which occurs mainly in immunocompromised patients and can be life-threatening. We report the case of an 87-year-old woman who was treated with oral corticosteroids for polymyalgia rheumatica for many years and developed erythema nodosum-like lesions on the right forearm and arthritis of the right wrist. By increasing the steroid dosage and adding methotrexate only short-term remission was achieved. Seven months later painful erythematous nodules occurred on all extremities which became necrotic, ulcerative and suppurative. Ziehl-Neelsen staining revealed acid-fast bacilli and Mycobacterium marinum was cultured from skin biopsies, blood, and urine. The critically ill patient was treated with clarithromycin and ethambutol resulting in a dramatic improvement of the general condition. After four months, doxycycline had to be added because of new skin lesions. This case illustrates the impact of Mycobacterium marinum infection in immunocompromised patients.
Resumo:
Induction of interferon-beta (IFN-beta) gene expression is a tightly regulated process, and a plethora of studies identified the signal transduction pathway TANK-binding kinase-1 (TBK-1)/IFN regulatory factor-3 (IRF-3) as essential to the induction of IFN-beta gene expression. Data regarding the role of p38 and JNK are rare, however. We investigated the contribution of these kinases to IFN-beta expression in human macrophages treated with poly(I:C), lipopolysaccharide (LPS), Sendai virus, or vesicular stomatitis virus (VSV). We found that all the stimuli induced IFN-beta mRNA, albeit to a different extent. Whereas LPS and VSV induced the phosphorylation of p38 and JNK, neither poly(I:C) nor Sendai virus led to the detection of phosphospecific signals. When inhibiting p38, a VSV-triggered IFN-beta mRNA response was inhibited, whereas inhibiting JNK suppressed an LPS-triggered response, but only when macrophages were primed with IFN-gamma. Neither poly(I:C)-induced nor Sendai virus-induced IFN-beta mRNA expression was affected when p38 and JNK were inhibited. Collectively, the data show that the contribution of p38 and JNK to the expression of IFN-beta occurs in a stimulation-specific manner in human macrophages.
Resumo:
In mid-July 2003, the U.S. Army Tank-Automotive & Armaments Command (TACOM) performed a series of experiments at Keweenaw Research Center (KRC), with a remote operated mine roller system. This system, named Panther Lite, consists of two M113 Armored Personnel Carriers (APC’s) connected by a Tandem Vehicle Linkage Assembly (TVLA). The system has three sets of mine rollers, two of which are connected to the front of the lead vehicle with one set trailing from the trail vehicle. Currently, the system requires two joystick controllers. One regulates the braking of the tracks, throttle, and transmission of the lead vehicle and the other controls the braking and throttle of the rear vehicle. One operator controls both joysticks, attempting to maneuver the lead vehicle along a desired path. At the same time, this operator makes compensation maneuvers to reduce lateral loads in the TVLA and to guide the rear mine rollers along the desired path. The purpose of this project is to create algorithms that would allow the slave (trail) vehicle to operate using inputs that maneuver the control (lead) vehicle. The project will be completed by first reconstructing the experimental data. Kinematic models will be generated and simulations created. The models will then be correlated with the reconstructions of the experimental data. The successful completion of this project will be a first step to eliminating the need for the second joystick.
Resumo:
The Environmental Health (EH) program of Peace Corps (PC) Panama and a non-governmental organization (NGO) Waterlines have been assisting rural communities in Panama gain access to improved water sources through the practice of community management (CM) model and participatory development. Unfortunately, there is little information available on how a water system is functioning once the construction is complete and the volunteer leaves the community. This is a concern when the recent literature suggests that most communities are not able to indefinitely maintain a rural water system (RWS) without some form of external assistance (Sara and Katz, 1997; Newman et al, 2002; Lockwood, 2002, 2003, 2004; IRC, 2003; Schweitzer, 2009). Recognizing this concern, the EH program director encouraged the author to complete a postproject assessment of the past EH water projects. In order to carry out the investigation, an easy to use monitoring and evaluation tool was developed based on literature review and the author’s three years of field experience in rural Panama. The study methodology consists of benchmark scoring systems to rate the following ten indicators: watershed, source capture, transmission line, storage tank, distribution system, system reliability, willingness to pay, accounting/transparency, maintenance, and active water committee members. The assessment of 28 communities across the country revealed that the current state of physical infrastructure, as well as the financial, managerial and technical capabilities of water committees varied significantly depending on the community. While some communities are enjoying continued service and their water committee completing all of its responsibilities, others have seen their water systems fall apart and be abandoned. Overall, the higher score were more prevalent for all ten indicators. However, even the communities with the highest scores requested some form of additional assistance. The conclusion from the assessment suggests that the EH program should incorporate an institutional support mechanism (ISM) to its sector policy in order to systematically provide follow-up support to rural communities in Panama. A full-time circuit rider with flexible funding would be able to provide additional technical support, training and encouragement to those communities in need.
Resumo:
The South Florida Water Management District (SFWMD) manages and operates numerous water control structures that are subject to scour. In an effort to reduce scour downstream of these gated structures, laboratory experiments were performed to investigate the effect of active air-injection downstream of the terminal structure of a gated spillway on the depth of the scour hole. A literature review involving similar research revealed significant variables such as the ratio of headwater-to-tailwater depths, the diffuser angle, sediment uniformity, and the ratio of air-to-water volumetric discharge values. The experimental design was based on the analysis of several of these non-dimensional parameters. Bed scouring at stilling basins downstream of gated spillways has been identified as posing a serious risk to the spillway’s structural stability. Although this type of scour has been studied in the past, it continues to represent a real threat to water control structures and requires additional attention. A hydraulic scour channel comprised of a head tank, flow straightening section, gated spillway, stilling basin, scour section, sediment trap, and tail-tank was used to further this analysis. Experiments were performed in a laboratory channel consisting of a 1:30 scale model of the SFWMD S65E spillway structure. To ascertain the feasibility of air injection for scour reduction a proof-of-concept study was performed. Experiments were conducted without air entrainment and with high, medium, and low air entrainment rates for high and low headwater conditions. For the cases with no air entrainment it was found that there was excessive scour downstream of the structure due to a downward roller formed upon exiting the downstream sill of the stilling basin. When air was introduced vertically just downstream of, and at the same level as, the stilling basin sill, it was found that air entrainment does reduce scour depth by up to 58% depending on the air flow rate, but shifts the deepest scour location to the sides of the channel bed instead of the center. Various hydraulic flow conditions were tested without air injection to verify which scenario caused more scour. That scenario, uncontrolled free, in which water does not contact the gate and the water elevation in the stilling basin is lower than the spillway crest, would be used for the remainder of experiments testing air injection. Various air flow rates, diffuser elevations, air hole diameters, air hole spacings, diffuser angles and widths were tested in over 120 experiments. Optimal parameters include air injection at a rate that results in a water-to-air ratio of 0.28, air holes 1.016mm in diameter the entire width of the stilling basin, and a vertically orientated injection pattern. Detailed flow measurements were collected for one case using air injection and one without. An identical flow scenario was used for each experiment, namely that of a high flow rate and upstream headwater depth and a low tailwater depth. Equilibrium bed scour and velocity measurements were taken using an Acoustic Doppler Velocimeter at nearly 3000 points. Velocity data was used to construct a vector plot in order to identify which flow components contribute to the scour hole. Additionally, turbulence parameters were calculated in an effort to help understand why air-injection reduced bed scour. Turbulence intensities, normalized mean flow, normalized kinetic energy, and anisotropy of turbulence plots were constructed. A clear trend emerged that showed air-injection reduces turbulence near the bed and therefore reduces scour potential.
Resumo:
As continued global funding and coordination are allocated toward the improvement of access to safe sources of drinking water, alternative solutions may be necessary to expand implementation to remote communities. This report evaluates two technologies used in a small water distribution system in a mountainous region of Panama; solar powered pumping and flow-reducing discs. The two parts of the system function independently, but were both chosen for their ability to mitigate unique issues in the community. The design program NeatWork and flow-reducing discs were evaluated because they are tools taught to Peace Corps Volunteers in Panama. Even when ample water is available, mountainous terrains affect the pressure available throughout a water distribution system. Since the static head in the system only varies with the height of water in the tank, frictional losses from pipes and fittings must be exploited to balance out the inequalities caused by the uneven terrain. Reducing the maximum allowable flow to connections through the installation of flow-reducing discs can help to retain enough residual pressure in the main distribution lines to provide reliable service to all connections. NeatWork was calibrated to measured flow rates by changing the orifice coefficient (θ), resulting in a value of 0.68, which is 10-15% higher than typical values for manufactured flow-reducing discs. NeatWork was used to model various system configurations to determine if a single-sized flow-reducing disc could provide equitable flow rates throughout an entire system. There is a strong correlation between the optimum single-sized flow- reducing disc and the average elevation change throughout a water distribution system; the larger the elevation change across the system, the smaller the recommended uniform orifice size. Renewable energy can jump the infrastructure gap and provide basic services at a fraction of the cost and time required to install transmission lines. Methods for the assessment of solar powered pumping systems as a means for rural water supply are presented and assessed. It was determined that manufacturer provided product specifications can be used to appropriately design a solar pumping system, but care must be taken to ensure that sufficient water can be provided to the system despite variations in solar intensity.
Resumo:
ContentsBuilding a businessDiver displays artistry in scienceEvent offers food for thoughtRaw milk stirs up hot debate Gymnasts piece together puzzle before regionalsGlobal gas tank nears emptyBirds' nest treats for Easter time
Resumo:
BACKGROUND Periprosthetic joint infection (PJI) is the most severe complication, following joint arthroplasty. Identification of the causal microbial factor is of paramount importance for the successful treatment. PURPOSE The aim of this study is to compare the sonication fluid cultures derived from joint prosthetic components with the respective periprosthetic tissue cultures. METHODS Explanted prosthesis components for suspected infection were placed into a tank containing sterile Ringer's solution and sonicated for 1 minute at 40 kHz. Sonication fluid cultures were examined for 10 days, and the number and identity of any colony morphology was recorded. In addition, periprosthetic tissue specimens (>5) were collected and cultured according to standard practice. The duration of antimicrobial interruption interval before culture sampling was recorded. RESULTS Thirty-four patients composed the study group. Sonication fluid cultures were positive in 24 patients (70.5%). Sixteen of thirty four periprosthetic tissue cultures (47.1%) were considered positive, all revealing the same microbial species with the respective sonication fluid cultures: 3 tissue samples showed polymicrobial infection. All tissue cultures were also found positive by the sonication fluid culture. CONCLUSIONS Sonication fluid cultures represent a cheap, easy, accurate, and sensitive diagnostic modality demonstrating increased sensitivity compared to periprosthetic tissue cultures (70.5 versus 47.1%).
Resumo:
The objective of this study was to describe the udder health management in Swiss dairy herds with udder health problems. One hundred dairy herds with a yield-corrected somatic cell count of 200'000 to 300'000 cells/ml during 2010 were selected. Data concerning farm structure, housing system, milking technique, milking procedures, dry-cow and mastitis management were collected during farm visits between September and December 2011. In addition, quarter milk samples were collected for bacteriological culturing from cows with a composite somatic cell count ≥ 150'000 cells/ml. The highest quarter level prevalence was 12.3 % for C. bovis. Eighty-two percent of the pipeline milking machines in tie-stalls and 88 % of the milking parlours fulfilled the criteria for the vacuum drop, and only 74 % of the pipeline milking machines met the criteria of the 10-l-water test. Eighty-five percent of the farms changed their milk liners too late. The correct order of teat preparation before cluster attachment was carried out by 37 % of the farmers only. With these results, Swiss dairy farmers and herd health veterinarians can be directed to common mistakes in mastitis management. The data will be used for future information campaigns to improve udder health in Swiss dairy farms.
Resumo:
Based on a dye tracer experiment in a sand tank we addressed the problem of local dispersion of conservative tracers in the unsaturated zone. The sand bedding was designed to have a defined spatial heterogeneity with a strong anisotropy. We estimated the parameters that characterize the local dispersion and dilution from concentration maps of a high spatial and temporal resolution obtained by image analysis. The plume spreading and mixing behavior was quantified on the basis of the coefficient of variation of the concentration and of the dilution index. The heterogeneous structure modified the flow pattern depending on water saturation. The shape of the tracer plumes revealed the structural signature of the sand bedding at low saturation only. In this case pronounced preferential flow was observed. At higher flow rates the structure remained hidden by a spatially almost homogeneous behavior of the plumes. In this context, we mainly discuss the mechanism of re-distributing a finite mass of inert solutes over a large volume, due to macro- and micro-heterogeneities of the structure. (C) 2001 Elsevier Science Ltd. AU rights reserved.
Resumo:
The Radiological Physics Center (RPC) provides heterogeneous phantoms that are used to evaluate radiation treatment procedures as part of a comprehensive quality assurance program for institutions participating in clinical trials. It was hypothesized that the existing RPC heterogeneous thorax phantom can be modified to assess lung tumor proton beam therapy procedures involving patient simulation, treatment planning, and treatment delivery, and could confirm agreement between the measured dose and calculated dose within 5%/3mm with a reproducibility of 5%. The Hounsfield Units (HU) for lung equivalent materials (balsa wood and cork) was measured using a CT scanner. The relative linear stopping power (RLSP) of these materials was measured. The linear energy transfer (LET) of Gafchromic EBT2 film was analyzed utilizing parallel and perpendicular orientations in a water tank and compared to ion chamber readings. Both parallel and perpendicular orientations displayed a quenching effect underperforming the ion chamber, with the parallel orientation showing an average 31 % difference and the perpendicular showing an average of 15% difference. Two treatment plans were created that delivered the prescribed dose to the target volume, while achieving low entrance doses. Both treatment plans were designed using smeared compensators and expanded apertures, as would be utilized for a patient in the clinic. Plan 1a contained two beams that were set to orthogonal angles and a zero degree couch kick. Plan 1b utilized two beams set to 10 and 80 degrees with a 15 degree couch kick. EBT2 film and TLD were inserted and the phantom was irradiated 3 times for each plan. Both plans passed the criteria for the TLD measurements where the TLD values were within 7% of the dose calculated by Eclipse. Utilizing the 5%/3mm criteria, the 3 trial average of overall pass rate was 71% for Plan 1a. The 3 trial average for the overall pass rate was 76% for Plan 1b. The trials were then analyzed using RPC conventional lung treatment guidelines set forth by the RTOG: 5%/5mm, and an overall pass rate of 85%. Utilizing these criteria, only Plan 1b passed for all 3 trials, with an average overall pass rate of 89%.
Resumo:
I solved equations that describe coupled hydrolysis in and absorption from a continuously stirred tank reactor (CSTR), a plug flow reactor (PFR), and a batch reactor (BR) for the rate of ingestion and/or the throughput time that maximizes the rate of absorption (=gross rate of gain from digestion). Predictions are that foods requiring a single hydrolytic step (e.g., disaccharides) yield ingestion rates that vary inversely with the concentration of food substrate ingested, whereas foods that require multiple hydrolytic and absorptive reactions proceeding in parallel (e.g., proteins) yield maximal ingestion rates at intermediate substrate concentrations. Counterintuitively, then, animals acting to maximize their absorption rates should show compensatory ingestion (more rapid feeding on food of lower concentration), except for the lower range of diet quality fur complex diets and except for animals that show purely linear (passive) uptake. At their respective maxima in absorption rates, the PFR and BR yield only modestly higher rates of gain than the CSTR but do so at substantially lower rates of ingestion. All three ideal reactors show milder than linear reduction in rate of absorption when throughput or holding time in the gut is increased (e.g., by scarcity or predation hazard); higher efficiency of hydrolysis and extraction offset lower intake. Hence adding feeding costs and hazards of predation is likely to slow ingestion rates and raise absorption efficiencies substantially over the cost-free optima found here.