932 resultados para Surfaces and Interfaces


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The cervical enamel projection (CEP) is an anatomic variation that can be found in the cement enamel junction, it´s recognition and early diagnosis improves outcome the tooth involved, allowing greater efficiency in treatment. The knowledge of the location, grade and incidence of CEP is decisive on prevention and treatment of periodontal disease. It were studied 1200 molars (600 mandibular molars and 600 maxillary molars) separated from the collection of teeth on the Discipline of Anatomy in FOSJCampos - UNESP. Each group of 600 teeth was separated from the second side (300 teeth) and the second type (first, second or third molar). Each tooth had thoroughly inspected the cervical region, in all their faces, in order to verify the incidence and the grade of CEP in each surface. It was found that the CEP covered in 278 (23,17%) teeth was 146 (52,52%) mandibular molars and 132 (47,48%) maxillary molars. The CEPs were concentrated on a tooth surface in 222 (79,86%) teeth, in two surfaces 53 (19,06%) teeth, and in three surfaces in three (1,08%) teeth. From the total of 4.800 surfaces examined the CEPs were found in 337 surfaces, and 228 (67,66%) surfaces of the grade I, 60 (17,8%) grade II and 49 (14,54%) grade III. The buccal surface presented 207 (61,42%) CEP, the lingual surface in 57 (16,91%), the mesial surface in 35 (10,39%) and the distal surface in 38 (11,28%) CEP. The results of this study demonstrated that the CEPs have focused more on the mandibular teeth on only one surface of the tooth, the grade I was the most found and the buccal surface the most involved

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Shearplate is an optical glass plate having two flat surfaces and a small angle between them. The use of a high quality shear plate is essential to implement shear interferometric technique . The shear interferometry is a technique used to evaluate the light beam collimation. In order to guarantee the shearplate quality , the complete manufacturing process must be thoroughly monitored. In the manufacturing process, the first step consisted of the glass selection. The selected glass has been submitted to the process of cutting, gluing, chamfering, grinding and polishing. Each phase has been strictly monitored. The quality of the final result depends extremely on an appropriate starting condition, which arises from the grinding process, as the polishing process only recovers the brightness of the part, acting on a small scale on the wearing off of the part, as well as not changing the structured obtained in the grinding process. Respecting all stages of the manufacturing process, the quality of the part has evolved to a good result. The best result obtained showed PV distance of 162 nm, slightly less than λ / 4. This result is significant because the dimensions of the piece with respect to the dimensions of the polisher what interferes directly in the results. The closer are the dimensions of piece and the dimensions of the polisher, the greater the difficulty in controlling the propagation of errors

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Matemática Universitária - IGCE

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Serviço Social - FCHS

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study aimed to evaluate the clinical and microscopic changes of MIH, and compare them to areas of healthy dental enamel. Methodology: epoxy resin replicas of healthy incisors and affected by MIH were evaluated qualitatively by scanning electron microscopy (SEM) photographs. Results: Clinically it was observed that MIH incisors showed changes in color and surface, with significant structural losses. By SEM, these had irregular surfaces and margins with structural losses. Conclusions: The teeth affected by HMI have clinical and morphological characteristics that are important for the definition of patient's treatment plan.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We study the photodecomposition of phospholipid bilayers in aqueous solutions of methylene blue. Observation of giant unilamellar vesicles under an optical microscope reveals a consistent pattern of membrane disruption as a function of methylene blue concentration and photon density for different substrates supporting the vesicles.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the possibility to obtaining guided bone regeneration utilizing a nonporous PTFE barrier in the osseointegrated implants, protruding from the bone level of the rabbit tíbia. The histologic characteristics of the interface between titanium implants, one group titanium-plasma coated, another group with acid-treated surfaces and the regenerated bone were also studied Twenty Screw-Vent implants were placed in tibias of five rabbits, two at the right side and two at the left side, protruding 3 mm from the bone level, to create a horizontal bone defect. ln the experimental side, the implants and adjacent bone were protected with a nonporous PTFE barrier. Histologic analysis after three months showed that all implants were in direct contact with the bane. Histologic measurements showed an average gain in bone height of the 2.15 and 2.42 mm for the barrier group and 1.95 and 0.43 mm for the control defects, in the titanium plasma-spray and acid-treated implant surfaces, respectively. The results suggest that the placement of implants protruding 3 mm from crestal bone defects may result in vertical bone augmentation and the regenerated bone is able to osseointegrate implants. lt seems to be critical the use of the PTFE barrier when acid-treated surface implants are inserted

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Nanotubes have been subject of studies with regard to their ability to promote differentiation of several cells lines. Nanotubes have been used to increase the roughness of the implant surfaces and to improve bone tissue integration on dental implant. In this study TiO2 nanotube layer prepared by anodic oxidation was evaluated. Nanotube formation was carried out using Glycerol-H2O DI(50-50 v/v)+NH4F(0,5 a 1,5% and 10-30V) for 1-3 hours at 37ºC. After nanostructure formation the topography of surface was observed using field-emission-scanning-microscope (FE-SEM). Contact angle was evaluated on the anodized and non-anodized surfaces using a water contact angle goniometer in sessile drop mode with 5 μL drops. In the case of nanotube formation and no treatment surface were presented 39,1° and 75,9°, respectively. The contact angle describing the wettability of the surface is enhanced, more hydrophilic, on the nanotube surfaces, which can be advantageous for enhancing protein adsorption and cell adhesion.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Wood is a renewable material and has unique characteristics that stem from its orthotropic properties. The objective of this study was to develop and implement an informational Selection of Materials and Manufacturing Processes appropriate to the activity of Product Design - Woods. Composed of a Digital Information System, distributed, and an ordered collection of samples. The design of a product, carries with it the choice of material, and the choice of a manufacturing process. Information on materials and manufacturing processes are available with different content, media and interfaces. However, such information is not systematized so that they can be recovered, as the need for the designer, especially on wood. This set of methods is called the Selection of Materials and Manufacturing Processes. It is hoped through this study that the methodologies for SMPF are employed by product designers, architects and engineers in Brazil.