879 resultados para Support surface functional group influence
Resumo:
Fibrinolysis is a basic defense mechanism of the organism designed to control the deposition of fibrin in the vascular system and elsewhere. Fibrinolytic activity was measured by the fibrin plate method for three groups of rats (N = 6) that were maintained at room temperature, 20-25 degrees C, 3 degrees C or 38 degrees C for 4 h before testing. Based on measurement of fibrinolytic activity, the level of plasminogen activator released from isolated aortic segments of rats maintained at room temperature (24-28 degrees C) differed significantly from that of the 38 degrees C group. The animals maintained at 3 degrees C did not release plasminogen activator, suggesting that the fibrinolytic response was impaired at low temperature.
Resumo:
Purpose: To evaluate the influence of three different adhesives, each used as an intermediary layer, on microleakage of sealants applied under condition of salivary contamination. Materials and Methods: Six different experimental conditions were compared, 3 with adhesives and 3 without. After prophylaxis and acid etching of enamel, salivary contamination was placed for 10 s. In Group SC the sealant was applied after saliva without bonding agent and then light-cured. In Group SCA, after saliva, the surface was air dried, and then the sealant was applied and cured. In Groups ScB, SB and PB, a bonding agent (Scotchbond Dual Cure/3M, Single Bond/3M and Prime & Bond 2.1/Dentsply, respectively) was applied after the saliva and prior to the sealant application and curing. After storage in distilled water at 37°C for 24 hrs, the teeth were submitted to 500 thermal cycles (5°C and 55°C), and silver nitrate was used as a leakage tracer. Leakage data were collected on cross sections as percentage of total enamel-sealant interface length. Representative samples were evaluated under SEM. Results: Sealants placed on contaminated enamel with no bonding agent showed extensive microleakage (94.27% in SC; 42.65% in SCA). The SEM revealed gaps as wide as 20 μm in areas where silver nitrate leakage could be visualized. In contrast, all bonding agent groups showed leakage less than 6.9%. Placement of sealant with a dentin-bonding agent on contaminated enamel significantly reduced microleakage (P< 0.0001). The use of a bonding agent as an intermediary layer between enamel and sealant significantly reduced saliva's effect on sealant microleakage.
Resumo:
PURPOSE: To evaluate the number and morphology of fibroblasts grown on machined titanium healing abutments treated with an airpowder system. MATERIALS AND METHODS: Twenty-six abutments were assigned to two experimental groups: control (no treatment) and treated (exposed to the Prophy-Jet for 30 seconds). The specimens were incubated for 24 hours with fibroblastic cells in multiwell plates, followed by routine laboratory processing for scanning electron microscope analysis. The specimens were photographed at x 350, and the cell number was counted on an area of approximately 200 um2. RESULTS: No significant differences were found on morphology between the groups (P > 0.05); however, the control group presented a significantly greater amount of cells (71.44 +/- 31.93, mean +/- SD) in comparison with treated group (35.31 +/- 28.14), as indicated by a nonpaired t test (P = 0.001). CONCLUSION: The use of an air-abrasive prophylaxis system on the surface of titanium healing abutments reduced the cells proliferation but did not influence cell morphology.
Resumo:
This paper presents some initial concepts for including reactive power in linear methods for computing Available Transfer Capability (ATC). It is proposed an approximation for the reactive power flows computation that uses the exact circle equations for the transmission line complex flow, and then it is determined the ATC using active power distribution factors. The transfer capability can be increased using the sensitivities of flow that show the best group of buses which can have their reactive power injection modified in order to remove the overload in the transmission lines. The results of the ATC computation and of the use of the sensitivities of flow are presented using the Cigré 32-bus system. © 2004 IEEE.
Resumo:
Objectives: The purpose of the this study was to evaluate the influence of thermocycling on shear bond strength on bovine enamel and dentin surfaces of different adhesive systems. Methods: Thirty sound bovine incisors were sectioned in mesiodistal and inciso-cervical direction obtaining 60 incisal surfaces (enamel) and 60 cervical surfaces (dentin). Specimens were randomly assigned to 3 groups of equal size (n = 40), according to the adhesive system used: I-Single Bond; II-Prime & Bond NT/NRC; III-One Coat Bond. After 24-h storage in distilled water at 37 o C, each main group was divided into two subgroups: A- specimens tested after 24 h storage in distilled water at 37°C; B - specimens submitted to thermocycling (500 cycles). Shear bond strength tests were performed. Data were submitted to ANOVA and Tukey test. Results: Means (MPa) of different groups were: I-AE-16.96, AD-17.46; BE-21.60, BD-12.79; II-AE-17.20, AD-11.93; BE-20.67, BD-13.94; III-AE-25.66, AD-17.53; BE-24.20, BD-19.38. Significance: Thermocycling did not influence significantly the shear bond strength of the tested adhesive systems; enamel was the dental substrate that showed larger adhesive strength; One Coat Bond system showed the best adhesive strength averages regardless of substrate or thermocycling. © 2005 Springer Science + Business Media, Inc.
Resumo:
Objectives: The aim of this study was to evaluate the effect of thermal and mechanical cycling alone or in combination, on the flexural strength of ceramic and metallic frameworks cast in gold alloy or titanium. Methods: Metallic frameworks (25 mm × 3 mm × 0.5 mm) (N = 96) cast in gold alloy or commercial pure titanium (Ti cp) were obtained using acrylic templates. They were airborne particle-abraded with 150 μm aluminum oxide at the central area of the frameworks (8 mm × 3 mm). Bonding agent and opaque were applied on the particle-abraded surfaces and the corresponding ceramic for each metal was fired onto them. The thickness of the ceramic layer was standardized by positioning the frameworks in a metallic template (height: 1 mm). The specimens from each ceramic-metal combination (N = 96, n = 12 per group) were randomly assigned into four experimental fatigue conditions, namely water storage at 37 °C for 24 h (control group), thermal cycling (3000 cycles, between 4 and 55 °C, dwell time: 10 s), mechanical cycling (20,000 cycles under 10 N load, immersion in distilled water at 37 °C) and, thermal and mechanical cycling. A flexural strength test was performed in a universal testing machine (crosshead speed: 1.5 mm/min). Data were statistically analyzed using two-way ANOVA and Tukey's test (α = 0.05). Results: The mean flexural strength values for the ceramic-gold alloy combination (55 ± 7.2 MPa) were significantly higher than those of the ceramic-Ti cp combination (32 ± 6.7 MPa) regardless of the fatigue conditions performed (p < 0.05). Mechanical and thermo-mechanical fatigue decreased the flexural strength results significantly for both ceramic-gold alloy (52 ± 6.6 and 53 ± 5.6 MPa, respectively) and ceramic-Ti cp combinations (29 ± 6.8 and 29 ± 6.8 MPa, respectively) compared to the control group (58 ± 7.8 and 39 ± 5.1 MPa, for gold and Ti cp, respectively) (p < 0.05) (Tukey's test). While ceramic-Ti cp combinations failed adhesively at the metal-opaque interface, gold alloy frameworks exhibited a residue of ceramic material on the surface in all experimental groups. Significance: Mechanical and thermo-mechanical fatigue conditions decreased the flexural strength values for both ceramic-gold alloy and ceramic-Ti cp combinations with the results being significantly lower for the latter in all experimental conditions. © 2007 Academy of Dental Materials.
Resumo:
Although there are almost thirty-thousand species of fish living in a great variety of habitats and utilizing vast reproductive strategies, our knowledge of morphofunctional and quantitative aspects of testis structure and spermatogenesis is still incipient for this group of vertebrates. In this review, we discuss aspects that are important to better understanding of testis structure and function, and of the development of germ cells (GC) during spermatogenesis. To achieve this, we have recently completed a number of studies presenting morphometric and functional data related to the numbers of GC and Sertoli cells (SC) per each type of spermatogenic cyst, the number of spermatogonial generations, the SC efficiency, and the magnitude of GC loss that normally occurs during spermatogenesis. We also investigated SC proliferation and the relationship of this important event to early spermatogenic cysts. The available data strongly suggest that SC proliferation in sexually mature tilapia is the primary factor responsible for the increase in testis size and for determination of the magnitude of sperm production. The influence of temperature on the duration of spermatogenesis in tilapia was also evaluated and we have used this knowledge to deplete endogenous spermatogenesis in this teleost, in order to develop an experimental system for GC transplantation. This exciting technique results in new possibilities for investigation of spermatogenesis and spermatogonial stem cell biology, creating also an entirely new and promising scenario in biotechnology - transgenic animal production and the preservation of the genetic stocks of valuable animals or endangered species. © Springer Science+Business Media B.V. 2008.
Resumo:
The aim of this study is to evaluate the flexural resistance of three types of restorative materials: compomer (Freedom), resin-modified glass-ionomer (Vitremer) and composite resin (Esthet-X), observing whether the application of bleaching agent can cause alterations of their flexural properties. Sixty samples were made using a 10 x 1 x 1 mm brass mold, and divided into three groups: G1- Freedom (SDI); G2- Vitremer (3M ESPE); G3- Esthet-X (Dentsply). On half of the samples of each group (10 samples) the bleaching treatment was applied and the other half used as control, was stored in distilled water at a temperature of 37 degrees C. Whiteness HP Maxx bleaching system was applied on the sample surface following the manufacturer's recommendations, simulating the bleaching treatment at the clinic. After this period, a flexural strength (three-point bending) test was conducted using (EMIC DL 1000) machine until the samples fractured. The data were submitted to ANOVA and Tukey tests. Of the restorative materials studied, G3-(87.24 +/- 31.40 MPa) presented the highest flexural strength, followed by G1-(61.67 +/- 21.32 MPa) and G2-(61.67 +/- 21.32 MPa). There was a statistical difference in flexural strength after the bleaching treatment. It was concluded that the use of a beaching agent can promote significant alteration of the flexural strength of these restorative materials.
Resumo:
Background: To investigate the effect of lisinopril on cardiac remodeling induced by smoking. Material/Methods: Rats were allocated into 3 groups: group CON (n=8): control; group CSE (n=8): cigarette smoke exposure; group CSE-LIS (n=8): exposed to tobacco smoke and treated with lisinopril. Results: After 2 months, the tail systolic pressure was lower in CSE-LIS (CON=116 ±27 mm Hg, CSE=126±16, CSE-LIS=89±12; P<.001). CSE animals showed higher left ventricular systolic diameter (CON=8.25±2.16 mm/kg, CSE=11.5±1.3, CSE-LIS=9.27±2.00; P=.009) and myocyte cross-sectional area (CON=245±8 μm2, CSE=260±17, CSE-LIS=238±12; P=.01) than CON and CSE-LIS. The ejection fraction (CON =0.91±0.02, CSE=0.86±0.02, CSE-LIS=0.92±0.03; P=.002) and fractional shortening (CON=55.7±4.41%, CSE=48.7±3.43, CSE-LI=58.2±7.63; P=.006) were lower in CSE group than CON and CSE-LIS. CSE and CSE-LIS animals showed higher collagen amounts (CON=3.49±0.95%, CSE= 5.01±1.58, CSE-LIS=5.27±0.62; P=.009) than CON. CON group showed a higher connexin 43 amount in the intercalated disc (CON=3.70±0.38, CSE=2.13±0.53; CSE-LIS=2.17±0.73; P=.004) than CSE and CSE-LIS. There were no differences in IFN-g or TNF-a cardiac levels among the groups. Conclusions: Lisinopril attenuated both morphologic and functional abnormalities induced by exposure to tobacco smoke. In addition, this effect was associated with diminished blood pressure, but not alterations in connexin 43 distribution, cytokine production or collagen amount. © Med Sci Monit, 2010.