997 resultados para Strain gages


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

NiTi wires and their weldments are commonly used in micro-electro-mechanical systems (MEMS), and in such applications, cyclic loading are commonly encountered. In this paper, the bending-rotation fatigue (BRF) test was used to study the bending fatigue behavior of NiTi wire laser weldment in the small-strain regime. The fracture mechanism, which includes crack initiation, crack growth and propagation of the weldment in the BRF test, was investigated with the aid of SEM fractography and discussed in terms of the microstructure. It was found that crack initiation was primarily surface-condition dependent. The cracks were found to initiate at the surface defects at the weld zone (WZ) surface, and the crack propagation was assisted by the gas inclusions in the WZ. The weldment was finally fractured in a ductile manner. The fatigue life was found to decrease with increasing surface strain and also with increasing bending frequency (controlled by the rotational speed in the BRF test). In comparison, the fatigue life of the unwelded NiTi wires was higher than their welded counterparts at all strain levels and bending frequencies. The decrease in fatigue resistance of the weldment could be attributed to the surface and microstructural defects introduced during laser welding.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Strain-dependent microstructural modifications were observed in epitaxial BiCrO3 (BCO) thin films fabricated on single crystalline substrates, utilizing pulsed laser deposition. The following conditions were employed to modify the epitaxial-strain: (i) in-plane tensile strain, BCOSTO [BCO grown on buffered SrTiO3 (001)] and in-plane compressive strain, BCONGO [BCO grown on buffered NdGaO3 (110)] and (ii) varying BCO film thickness. A combination of techniques like X-ray diffraction, X-ray photoelectron spectroscopy (XPS) and high resolution transmission electron microscopy (TEM) was used to analyse the epitaxial growth quality and the microstructure of BCO. Our studies revealed that in the case of BCOSTO, a coherent interface with homogeneous orthorhombic phase is obtained only for BCO film with thicknesses, d < 50 nm. All the BCOSTO films with d = 50 nm were found to be strain-relaxed with an orthorhombic phase showing 1/2 <100> and 1/4 <101> satellite reflections, the latter oriented at 45° from orthorhombic diffraction spots. High angle annular dark field scanning TEM of these films strongly suggested that the satellite reflections, 1/2 <100> and 1/4 <101>, originate from the atomic stacking sequence changes (or “modulated structure”) as reported for polytypes, without altering the chemical composition. The unaltered stoichiometry was confirmed by estimating both valency of Bi and Cr cations by surface and in-depth XPS analysis as well as the stoichiometric ratio (1 Bi:1 Cr) using scanning TEM–energy dispersive X-ray analysis. In contrast, compressively strained BCONGO films exhibited monoclinic symmetry without any structural modulations or interfacial defects, up to d ~ 200 nm. Our results indicate that both the substrate-induced in-plane epitaxial strain and the BCO film thickness are the crucial parameters to stabilise a homogeneous BCO phase in an epitaxially grown film.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The behaviour of syntactic foam is strongly dependent on temperature and strain rate. This research focuses on the behaviour of syntactic foam made of epoxy and glass microballoons in the glassy, transition and rubbery regions. Both epoxy and epoxy foam are investigated separately under tension and shear loadings in order to study the strain rate and temperature effects. The results indicate that the strength and strain to failure data can be collapsed onto master curves depending on temperature reduced strain rate. The highest strain to failure occurs in the transition zone. The presence of glass microballoons reduces the strain to failure over the entire range considered, an effect that is particularly significant under tensile loading. However, as the microballoons increase the elastic modulus significantly in the rubbery zone but reduce it somewhat in the glassy zone, the effect on the strength is more complicated. Different failure mechanisms are identified over the temperature-frequency range considered. As the temperature reduced strain rate is decreased, the failure mechanism changes from microballoon fracture to matrix fracture and debonding between the matrix and microballoons. © IMechE 2012.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Many patients and healthcare professionals believe that work-related psychosocial stress, such as job strain, can make asthma worse, but this is not corroborated by empirical evidence. We investigated the associations between job strain and the incidence of severe asthma exacerbations in working-age European men and women. Methods: We analysed individual-level data, collected between 1985 and 2010, from 102 175 working-age men and women in 11 prospective European studies. Job strain (a combination of high demands and low control at work) was self-reported at baseline. Incident severe asthma exacerbations were ascertained from national hospitalization and death registries. Associations between job strain and asthma exacerbations were modelled using Cox regression and the study-specific findings combined using random-effects meta-analyses. Results: During a median follow-up of 10 years, 1 109 individuals experienced a severe asthma exacerbation (430 with asthma as the primary diagnostic code). In the age- and sex-adjusted analyses, job strain was associated with an increased risk of severe asthma exacerbations defined using the primary diagnostic code (hazard ratio, HR: 1.27, 95% confidence interval, CI: 1.00, 1.61). This association attenuated towards the null after adjustment for potential confounders (HR: 1.22, 95% CI: 0.96, 1.55). No association was observed in the analyses with asthma defined using any diagnostic code (HR: 1.01, 95% CI: 0.86, 1.19). Conclusions: Our findings suggest that job strain is probably not an important risk factor for severe asthma exacerbations leading to hospitalization or death.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have developed an instrument to study the behavior of the critical current density (J(c)) in superconducting wires and tapes as a function of field (mu(0)H), temperature (T), and axial applied strain (epsilon(a)). The apparatus is an improvement of similar devices that have been successfully used in our institute for over a decade. It encompasses specific advantages such as a simple sample layout, a well defined and homogeneous strain application, the possibility of investigating large compressive strains and the option of simple temperature variation, while improving the main drawback in our previous systems by increasing the investigated sample length by approximately a factor of 10. The increase in length is achieved via a design change from a straight beam section to an initially curved beam, placed perpendicular to the applied field axis in the limited diameter of a high field magnet bore. This article describes in detail the mechanical design of the device and its calibrations. Additionally initial J(c)(epsilon(a)) data, measured at liquid helium temperature, are presented for a bronze processed and for a powder-in-tube Nb3Sn superconducting wire. Comparisons are made with earlier characterizations, indicating consistent behavior of the instrument. The improved voltage resolution, resulting from the increased sample length, enables J(c) determinations at an electric field criterion E-c=10 muV/m, which is substantially lower than a criterion of E-c=100 muV/m which was possible in our previous systems. (C) 2004 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite being the most suitable candidates for solenoid pole pieces in state-of-the-art superconductor- based electromagnets, the intrinsic magnetic properties of heavy rare earth metals and their alloys have gained comparatively little attention. With the potential of integration in micro- and nanoscale devices, thin films of Gd, Dy, Tb, DyGd and DyTb were plasma-sputtered and investigated for their in-plane magnetic properties, with an emphasis on magnetisation vs. temperature profiles. Based on crystal structure analysis of the polycrystalline rare earth films, which consist of a low magnetic moment FCC layer at the seed interface topped with a higher moment HCP layer, an experimental protocol is introduced which allows the direct magnetic analysis of the individual layers. In line with the general trend of heavy lanthanides, the saturation magnetisation was found to drop with increasing unit cell size. In-situ annealed rare earth films exceeded the saturation magnetisation of a high-moment Fe65Co35 reference film in the cryogenic temperature regime, proving their potential for pole piece applications; however as-deposited rare earth films were found completely unsuitable. In agreement with theoretical predictions, sufficiently strained crystal phases of Tb and Dy did not exhibit an incommensurate magnetic order, unlike their single-crystal counterparts which have a helical phase. DyGd and DyTb alloys followed the trends of the elemental rare earth metals in terms of crystal structure and magnetic properties. Inter-rare-earth alloys hence present a desirable blend of saturation magnetisation and operating temperature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper addresses the problems of effective in situ measurement of the real-time strain for bridge weigh in motion in reinforced concrete bridge structures through the use of optical fiber sensor systems. By undertaking a series of tests, coupled with dynamic loading, the performance of fiber Bragg grating-based sensor systems with various amplification techniques were investigated. In recent years, structural health monitoring (SHM) systems have been developed to monitor bridge deterioration, to assess load levels and hence extend bridge life and safety. Conventional SHM systems, based on measuring strain, can be used to improve knowledge of the bridge's capacity to resist loads but generally give no information on the causes of any increase in stresses. Therefore, it is necessary to find accurate sensors capable of capturing peak strains under dynamic load and suitable methods for attaching these strain sensors to existing and new bridge structures. Additionally, it is important to ensure accurate strain transfer between concrete and steel, adhesives layer, and strain sensor. The results show the benefits in the use of optical fiber networks under these circumstances and their ability to deliver data when conventional sensors cannot capture accurate strains and/or peak strains.